JJJ. Benjamin Jackson

J. Benjamin Jackson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


J. Benjamin Jackson has a total of 175 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Biomechanical comparison of parallel versus convergent screw fixation in Zadek osteotomy

    by Cesar Ramirez, Seif El Masry, Taylor Rakauskas, Gabrielle Meli, Jim Fitzsimmons, Alexander Hooke, Nathan Flath, Joshua Bland, John Mickley, J. Benjamin Jackson, et al.

    Purpose Zadek osteotomy is an increasingly utilized treatment for insertional Achilles tendinopathy (IAT), although an optimal fixation strategy remains unclear. This cadaveric study compared biomechanical outcomes of parallel and convergent screw fixation constructs following Zadek osteotomy. We hypothesized that convergent screw fixation would demonstrate greater stability. Methods Five paired fresh-frozen human calcanei (10 specimens) underwent simulated Zadek osteotomy, receiving paired parallel and convergent screw fixations on contralateral limbs. Specimens were tested using a servohydraulic system and motion tracking. Axial loading was applied until construct failure. Primary biomechanical outcomes included construct stiffness, load at 2 mm displacement, ultimate load to failure, and displacement at failure. Comparisons were performed using paired t-tests. One specimen was excluded from final analysis due to premature failure. Results No significant differences were observed between parallel and convergent constructs for any biomechanical outcome. Mean stiffness was 1415 ± 1337 N/mm for parallel constructs and 1360 ± 952 N/mm for convergent constructs (p = 0.96). Load at 2 mm displacement measured 707 ± 289 N and 892 ± 401 N, respectively (p = 0.54). Ultimate load to failure was 915 ± 266 N and 1065 ± 401 N, respectively (p = 0.55). Displacement at failure was similar between groups (p = 0.45). The combination shear-compression sliding at the osteotomy interface was the predominant mechanism of failure in both groups. Conclusion Parallel and convergent screw constructs demonstrated comparable initial fixation strengths following Zadek osteotomy, suggesting screw trajectory may have limited impact on construct stability. Further studies are needed to validate these findings clinically.

  • Open Access

    Complications After Minimally Invasive vs Open Calcaneal Osteotomy: A Retrospective Study

    by Sarah Hall Kiriluk, Dylan Crawford, Preston Harrison, Rodrigo Encinas, John O’KEefe, Harley T. Davis, Moawiah Mustafa, J. Benjamin Jackson, Tyler A. Gonzalez

    Background: A calcaneal osteotomy is a common component of surgical management for various foot and ankle deformities. Open and minimally invasive surgical (MIS) calcaneal osteotomies can be performed. The purpose of this study was to compare complication rates including infection, wound dehiscence, nerve damage, hardware failure, reoperation, and nonunion between these cohorts. Methods: All patients who underwent an open or MIS calcaneal osteotomy between March 2021 and July 2024 at a single institution were identified and retrospectively reviewed. All procedures were performed by one of 2 fellowship-trained orthopaedic foot and ankle surgeons on patients >18 years of age at the time of surgery. These procedures were performed in combination with other procedures to correct planus or cavus feet. Demographic information and postoperative complications were recorded for each patient with a minimum of 12 months follow-up. Results: Forty-four patients who underwent open calcaneal osteotomy and 26 patients who underwent MIS calcaneal osteotomy met the inclusion criteria for the current study. Patients were followed for a mean 25.3 ± 11.1 months. There was no significant difference in the rate of nonunion ( P = .703) or nerve complications ( P = .410) between cohorts. There were fewer postoperative minor wound complications in the MIS cohort (1/26, 3.8%) compared with the open cohort (9/44, 20.5%) ( P = .036) observed in the MIS cohort; however, the P = .036 difference in minor wound complications was found to be not significant after false discovery rate (FDR) adjustment. Conclusion: Data from the current study indicate that open and MIS calcaneal osteotomy are associated with no difference in major complication rates or amount of calcaneal correction. With the numbers available, no significant difference in total or minor complication rates could be detected after FDR adjustment, though fewer minor wound complications were observed in the MIS cohort (3.8% vs 20.5%). Both approaches were associated with significant improvements in patient-reported function and mobility; significant improvement in pain scores was observed in the MIS cohort only after FDR adjustment. Level of Evidence: Level IV, retrospective cohort study.

  • Open Access

    Reducing Sedentary Time After Knee Replacement Using a Multicomponent mHealth Intervention: Randomized Controlled Trial

    by Christine A Pellegrini, Clare L Kennerley, Sara Wilcox, Jungwha Lee, Katherine DeVivo, Kailyn Horn, Scott Jamieson, Jeffrey Hopkins, Harley T Davis, J Benjamin Jackson Iii

    Background: Total knee replacement (TKR) is a common surgery for end-stage knee osteoarthritis. Although reductions in pain and improvements in mobility occur after surgery, physical activity levels often do not change. Given the challenges of increasing physical activity in this population, targeting reductions in sedentary behavior may be a first step; however, no prior studies have examined the feasibility and effects of a sedentary reduction intervention after TKR. Objective: This study examined the effects of a 2-month multicomponent mobile health sedentary reduction intervention (NEAT!2) on sedentary time in adults with TKR. Methods: Adults (N=83; mean age 65.3, SD 9.4 years; mean BMI 32.7, SD 6.9 kg/m2; 62/83, 74.7% female; 64/83, 77.1% White) with a TKR ≤1 year ago were randomized to the NEAT!2 group (n=42, 50.6%) or the attention-matched control group (n=41, 49.4%). The NEAT!2 intervention focused on reducing sedentary time via a smartphone app designed to interrupt prolonged bouts (≥30 minutes) of sedentary behavior and through 5 coaching calls emphasizing goal setting and problem solving. The control group focused on surgery recovery via an app or website and 5 educational calls. Sedentary time, total physical activity, physical function, and pain were measured at 2 and 5 months. Linear mixed-effects models examined intervention effects and differences between groups at each time point. Results: Retention was 96% and 95% at 2 and 5 months, respectively, with no differences between groups. Participants in the NEAT!2 group completed an average of 4.95 (SD 0.2) calls, used the app on an average of 40.3 (SD 13.8) days (out of 56 days), and received an average of 9.6 (SD 6.0) notifications per day. At 5 months, there was a significant increase in sit-to-stand transitions in the NEAT!2 group and a substantial decrease in the control group, resulting in a significant difference between groups (mean difference 4.06, 95% CI 0.13-7.99; P=.04); however, the NEAT!2 intervention did not result in significant effects on any of the other study outcomes at 2 or 5 months. Additionally, more days of app use were associated with greater increases in moderate-to-vigorous intensity physical activity (r=0.335; 95% CI 0.017-0.585; P=.04). Conclusions: This study highlights the challenges of reducing sitting time in adults with TKR. Future studies should explore alternative behavior change techniques across different levels of influence (eg, environmental and social) to support interventions implemented within the first year after TKR. Trial Registration: ClinicalTrials.gov NCT04482400; https://clinicaltrials.gov/ct2/show/NCT04482400

  • A Comparison of Postoperative Patient-reported Outcomes After Hallux Surgery With a Modified Lapidus Versus a Metaphyseal Extra-articular Transverse and Akin Osteotomy

    by J. Benjamin Jackson, Heidi Ventresca, Kaleb Eaton, Stephanie Altobello, Tyler A. Gonzalez

    Background: The modified Lapidus procedure (MLP) and metaphyseal extra-articular transverse and Akin osteotomy (META) are acceptable surgical treatment options for treating hallux valgus. The current literature is evolving when comparing the different procedures' effects on patient-reported outcomes and postoperative complications. This study aims to compare postoperative outcomes, radiographic outcomes, and patient-reported outcomes using the Patient-reported Outcome Information System for MLP and META. Methods: This study retrospectively reviewed patients who underwent an MLP or META for the treatment of moderate to severe hallux valgus without associated first tarsometatarsal (TMT) instability between February 2020 and February 2022. Demographic data, radiographic outcomes, and Patient-reported Outcome Information System scores, including pain interference, physical function (PF), and mobility scores, were collected. The paired Student T- test and Wilcoxon rank sum test were used to compare continuous variables and the chi-squared test for categorical variables. Results: A total of 145 patients were included in the study. The average follow-up for MLP and META patients was 61.3 and 52.2 weeks, respectively. META patients had significantly higher improvements in PF (5.3 vs. 2.2, P = 0.03) and mobility (5.5 vs. 2.9, P = 0.02) scores compared with MLP patients. META patients also had a significantly lower nonunion rate (2.6% vs. 14.3%, P = 0.02), implant failure rate (0% vs. 10.4%, P < 0.01), recurrence rate (0% vs. 7.4%, P = 0.02), and greater improvement in hallux valgus angle (18.6° vs. 15.8°, P = 0.03) compared with those treated with MLP. Conclusion: META was found to improve patient-reported outcomes markedly more than MLP, with a lower radiographic nonunion rate, implant failure rate, and recurrence rate, and higher improvement in hallux valgus angle. These findings suggest META is a viable option in patients with mild, moderate, or severe HV deformity without TMT instability. Level of Evidence: III

  • Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure

    by Preston Harrison, Sarah Hall Kiriluk, Kevin Lee, Moawiah Mustafa, John O'KEefe, Shawn Guirau, Ettore Vulcano, A. Holly Johnson, Jonathan R. M. Kaplan, Oliver N. Schipper, et al.

    Background: Intraoperative fluoroscopy has become essential in orthopaedic surgery, particularly with the rise of minimally invasive surgery (MIS) techniques. As MIS techniques depend more on intraoperative imaging, MIS techniques may necessitate increased fluoroscopy use compared with open procedures. Despite the advantages of minimally invasive foot and ankle surgery, MIS techniques raise concerns about radiation exposure to both patients and surgical staff. The purpose of this study was to evaluate fluoroscopy time and radiation dose (cumulative air kerma) associated with open versus MIS bunion correction, comparing the open modified Lapidus procedure and the minimally invasive distal first metatarsal transverse osteotomy and akin osteotomy (META). It was hypothesized that the META procedure would be associated with increased radiation dose and fluoroscopy time compared with the open modified Lapidus procedure. Methods: A retrospective review was conducted for patients who underwent bunion surgery between January 2021 and June 2025 by two fellowship-trained orthopaedic foot and ankle surgeons at a single academic institution. A total of 294 patients met inclusion criteria. Of these, 258 patients underwent a META procedure and 36 underwent an open modified Lapidus procedure. Fluoroscopy time (minutes) and radiation dose (mGy) were compared between the groups. Results: A mean fluoroscopy time of 2.13 ± 1.27 (range, 0.06 to 7.05) minutes and a radiation dose of 2.02 ± 1.30 (range, 0.05 to 7.52) mGy were observed in the META cohort. An average fluoroscopy time of 1.63 ± 1.83 (range, 0.08 to 7.70) minutes and a radiation dose of 1.31 ± 1.43 (range, 0.07 to 5.98) mGy were observed in the open modified Lapidus cohort. Fluoroscopy time between the cohorts did not differ markedly ( P = 0.123); however, the META group demonstrated a higher radiation dose than the open modified Lapidus group ( P = 0.007). Conclusion: The META procedure had a markedly higher radiation dose compared with the open modified Lapidus procedure, although both remain substantially below the International Commission on Radiological Protection recommended occupational exposure of less than 20.00 mSv per year. Despite the META procedure generating an average radiation dose of 2.02 mGy per case, surgeons receive only 0.50% of the dose; thus, nearly 1,980 procedures would be required to exceed the 20.00 mSv annual occupational limit. These findings suggest that concerns about radiation exposure should not necessarily deter providers from performing the META technique for bunion correction. Level of Evidence: III (Retrospective Comparative Study)


  • Open Access

    Minimally Invasive Arthroscopy-Assisted Tibiotalocalcaneal Nailing for Complex Hindfoot Deformities: A Technique Tip

    by Cyrus Anthony Pumilia, Sarah Hall Kiriluk, John O’KEefe, Ettore Vulcano, J. Benjamin Jackson, Christopher P. Miller, Tyler A. Gonzalez

    Hindfoot reconstruction is a frequently performed procedure for many complex hindfoot deformities including flatfoot, end-stage arthritis, and Charcot arthropathy. Literature has supported the treatment of these patients with a tibiotalocalcaneal (TTC) arthrodesis. However, this limb salvage procedure is complex in nature and is traditionally performed as an open surgery. Minimally invasive (MIS) tibiotalar and subtalar fusions have allowed for similar efficacy as the open procedure, with the potential for less wound complications. The current study presents a guide for TTC nailing with MIS preparation of the tibiotalar and subtalar joints for severe, progressive hindfoot deformity in the high-risk patient. This technique allows for maintenance of the soft tissue envelope; maintaining the integrity of these structures may help surgeons avoid many wound related complications, infections, or need for revision. This guide provides surgeons with an effective and reproducible approach to intervene in complex cases requiring hindfoot reconstruction. Levels of Evidence: Level V Evidence

  • Open Access

    Weight loss and physical activity after total knee replacement: Study protocol for the Healthy Living randomized controlled trial

    by Christine A. Pellegrini, Sara Wilcox, Clare Kennerley, Jungwha Lee, Gabrielle Turner-McGrievy, Elizabeth Regan, Phillip Wessinger, Brian Chen, Harley T. Davis, Scott Jamieson, et al.


  • Open Access

    Radiation Exposure in Percutaneous Zadek Osteotomy vs Open Haglund Resection: A Retrospective Comparative Study

    by Preston Harrison, Sarah Hall Kiriluk, John O’KEefe, Harrison Lapin, Moawiah Mustafa, Shawn Guirau, Kevin Lee, Oliver N. Schipper, J. Benjamin Jackson, Tyler A. Gonzalez

    Background: Fluoroscopy is a vital imaging technique in orthopaedic surgery, particularly with the growing adoption of minimally invasive surgery (MIS). Because of their increased reliance on intraoperative imaging, MIS techniques may necessitate greater use of fluoroscopy and radiation compared with open procedures; therefore, the use of modern mini C-arm systems is recommended to mitigate radiation exposure. Although MIS offers significant benefits, its use also raises concerns regarding radiation exposure for both patients and surgical staff. This study evaluated radiation dose and fluoroscopy time comparing 2 common procedures used to treat insertional Achilles tendinitis: the percutaneous Zadek osteotomy (ZO) and the open midline Achilles tendon splitting Haglund resection (HR). We hypothesized that the percutaneous ZO would be associated with increased radiation dose and fluoroscopy time in comparison to the open HR but would be below the recommended occupational exposure limits. Methods: A retrospective review was conducted of all patients who underwent a percutaneous ZO or an open HR between January 2021 and July 2025. All procedures were performed by one of 2 fellowship-trained foot and ankle surgeons at a single academic institution. Radiation exposure was assessed using total radiation dose (mGy) and total fluoroscopy time (minutes). Results: A total of 139 patients met inclusion criteria. Sixty patients underwent a percutaneous ZO, whereas 79 underwent an open HR. The percutaneous ZO cohort demonstrated a mean fluoroscopy time of 2.83 ± 1.64 (range, 0.70-7.17) minutes and an average radiation dose of 3.25 ± 2.06 (range, 0.55-8.07) mGy. Meanwhile an average fluoroscopy time of 0.42 ± 0.19 (range, 0.03-0.90) minutes was observed in the open HR cohort, which had a mean radiation dose of 0.38 ± 0.20 (range, 0.02-1.17) mGy. The percutaneous ZO cohort demonstrated a significantly higher radiation dose ( P < .001) and fluoroscopy time ( P < .001). Conclusion: The percutaneous ZO was associated with a significantly higher radiation dose than the open HR; however, despite being statistically significant, this may not be clinically relevant. As surgeons receive only 0.50% of the dose, approximately 1225 percutaneous ZO procedures would be required to exceed annual safety limits. These findings suggest that radiation exposure during the percutaneous ZO technique remains well below the International Commission on Radiological Protection’s annual occupational limit of 20.00 mSv. Consistent with the ALARA principle, low-dose mini C-arm settings and protective equipment help minimize radiation exposure to patients and surgical staff. Level of Evidence: Level III, retrospective comparative study.


  • Open Access

    Pilot, Randomized Comparison of Traditionally Fabricated Custom Foot Orthoses vs HP Arize 3D-Printed Orthoses for Plantar Fasciitis

    by J. Benjamin Jackson, Kaleb Eaton, Harley T. Davis, Emily McKinney, Tyler A. Gonzalez

    Background: Plantar fasciitis is the most common cause of plantar heel pain and the use of custom foot orthosis is a well-supported treatment modality. Traditional custom orthoses are fabricated using foam impressions and manual techniques, but these methods are time-intensive and susceptible to variability in fit and quality. The HP Arize platform applies high-resolution 3D laser scanning with algorithm-driven modeling to streamline fabrication of custom foot orthoses. Although early reports suggest comparable comfort and durability to traditional devices, clinical data evaluating patient-reported outcomes remain limited. Methods: This prospective pilot, randomized study assigned 34 adults diagnosed with plantar fasciitis to receive either traditionally fabricated custom orthoses (n = 18) or HP Arize 3D-printed orthoses (n = 16). Primary analyses used a modified intention‑to‑treat cohort (n = 30) comprising participants who received an insert and completed baseline assessments. Patient-Reported Outcomes Measurement Information System (PROMIS) physical function, pain interference, and mobility scores were collected at baseline, 4 weeks, and 8 weeks. Secondary measures included patient satisfaction, frequency of orthotic use, and adverse effects. Statistical comparisons were performed using Fisher exact test and Student t test or Wilcoxon signed-rank test, with significance set at P < .05. Results: Baseline demographic and clinical characteristics did not differ between groups. At 4 weeks, satisfaction with customization, fit, and comfort was high across both groups (median 4.0-5.0). Traditional orthosis users reported greater daily use ( P = .04) but also higher rates of rubbing/discomfort ( P = .047). By 8 weeks, side effects were not statistically significantly different. Exploratory comparisons suggested higher mean PROMIS physical function (49.0 vs 41.9, Δ 7.1; P = .008) and mobility scores (46.9 vs 41.4, Δ 5.5; P = .02) at 8 weeks in the traditional group, whereas pain interference scores did not differ. Conclusion: Both traditionally fabricated and HP Arize 3D-printed custom orthoses were associated with high satisfaction and functional improvement. Although traditional devices showed greater early compliance and superior 8-week functional outcomes, the HP Arize system demonstrated fewer adverse effects and offers a scalable, efficient alternative. As an exploratory pilot study, these findings are preliminary and intended to inform feasibility and effect‑size estimation for future trials. Level of Evidence: Level IV, pilot prospective comparative study Type of Study: Quasi-experimental pre-post study.

  • Open Access

    Biomechanical performance of static and NiTiNOL compression devices in first metatarsophalangeal joint arthrodesis

    by James Johnson, Shannon King, Kristen Gregory, Courtney Kline, Tyler Gonzalez, J. Benjamin Jackson, David L. Safranski