JMJin-Soo Maeng

Jin-Soo Maeng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jin-Soo Maeng has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Gun-Soo Park

    Korea Food Research Institute

    7 shared publications
  • Seung-Hwa Baek

    Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Daejeon, Republic of Korea; Department of Predictive Toxicology, Korea Institute of Toxicology, Daejeon, Republic of Korea

    3 shared publications
  • Bum-Tae Kim

    Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Daejeon, Republic of Korea

    2 shared publications
  • Bum-Tae Kim

    Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Daejeon 34114, Korea

    2 shared publications
  • Keun Bon Ku

    Center for Infectious Disease Vaccine and Diagnosis Innovation (CEVI), Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea

    2 shared publications
  • Keunbon Ku

    Center for Convergent Research of Emerging Virus Infection, Korea Research Institute of Chemical Technology, Daejeon, Republic of Korea

    2 shared publications

Latest Publications

  • Open Access

    Development and Evaluation of RT-LAMP Assays to Identify Variants of SARS-CoV-2

    by Gun-Soo Park, Seong-Jun Kim, Jin-Soo Maeng

    Emergence of new variants of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) during current pandemic of Coronavirus Disease 2019 (COVID-19) and several waves of infections by some of variants emphasized the importance of continuous surveillance. While genomic surveillance through whole genome sequencing is performed as a standard method, identification of known variants through mutation-targeting molecular diagnosis such as qRT-PCR is also useful for timely investigation. However, there are limited studies regarding the concurrent detection and identification of SARS-CoV-2 variants through a LAMP-based method. In this study, we developed and evaluated RT-LAMP assays to detect characteristic deletions of SARS-CoV-2 variants. In addition, we evaluated a fluorescent probe mediated method for identification of single nucleotide substitution by RT-LAMP. Finally, we discussed restrictions and perspectives regarding pathogen screening and surveillance of variants by RT-LAMP based on our observations.


  • Development of Three-Stage Bioaerosol Sampler for Size-Selective Sampling

    by Jun-Hyung Lim, Sang Hwan Nam, Jongwoo Kim, Nam Hoon Kim, Gun-Soo Park, Jin-Soo Maeng, Se-Jin Yook

    In this study, a three-stage bio-aerosol sampler with a sampling flow rate of 170 L/min was designed and fabricated for sampling the bio-aerosols released during human breathing and coughing, and its performance was evaluated. The sampler was constructed using a cyclone separator with a cutoff size of 2.5 μm as a preseparator, a multinozzle virtual impactor with a cutoff size of 0.34 μm as an aerosol concentrator, and a Bio-Sampler, which is a commercial product, for collecting bio-aerosols in a collection fluid. The collection efficiency of the sampler was evaluated through simulations and experiments. Only particles with sizes of 0.1–4 μm were selectively collected in the collection fluid. Bacteriophage bio-aerosols were sampled using the developed sampler and ACD-200 Bobcat sampler, which is a commercial product. The amounts of collected bacteriophages were compared using the polymerase chain reaction (PCR) technique. The sampling performance of the developed sampler was similar to that of the ACD-200 Bobcat sampler. Moreover, the developed sampler showed its ability to sample bio-aerosols of a specific size range and collect them directly in a collection fluid for the PCR analysis. Therefore, the developed sampler is expected to be useful for indoor environmental monitoring by effectively sampling the bio-aerosols released indoors during human breathing and coughing.


  • Open Access

    A novel isothermal method for amplification of long specific amplicon from linear template

    by Gun-Soo Park, Jin-Soo Maeng

    Isothermal nucleic acid amplification methods have been successfully developed and applied for diagnostic purpose, especially for detection of pathogens. However, amplicon size of such methods is relatively short (< 500 bp) to limit their application for long amplicon production that can be used for various downstream applications including genomic surveillance of pathogens. To fill the gap, we developed a method for specific amplification of kilobases-long target sequence from RNA templates. This method, named CREA, utilizes sequence specific recombination of Cre recombinase to generate circular intermediate template for subsequent RCA reaction. CREA with SARS-CoV-2 spike template could amplify ~ 2.9 kb target and up to ~ 1.9 kb amplicon was able to produce in sufficient amount for general cloning. Each step of CREA procedure was thoroughly analyzed to provide directions for further optimizations. Furthermore, we evaluated a variation of CREA which utilized DNA ligase.


  • Top Cited Papers

    Development of Reverse Transcription Loop-Mediated Isothermal Amplification Assays Targeting Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)

    by Gun-Soo Park, Keunbon Ku, Seung-Hwa Baek, Seong-Jun Kim, Seung Il Kim, Bum-Tae Kim, Jin-Soo Maeng


  • Open Access

    Development of Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP) Assays Targeting SARS-CoV-2

    by Gun-Soo Park, Keunbon Ku, Seung-Hwa Baek, Seong Jun Kim, Seung Il Kim, Bum-Tae Kim, Jin-Soo Maeng

    Epidemics of Coronavirus Disease 2019 (COVID-19) now have more than 100,000 confirmed cases worldwide. Diagnosis of COVID-19 is currently performed by RT-qPCR methods, but the capacity of RT-qPCR methods is limited by its requirement of high-level facilities and instruments. Here, we developed and evaluated RT-LAMP assays to detect genomic RNA of SARS-CoV-2, the causative virus of COVID-19. RT-LAMP assays in this study can detect as low as 100 copies of SARS-CoV-2 RNA. Cross-reactivity of RT-LAMP assays to other human Coronaviruses was not observed. We also adapted a colorimetric detection method for our RT-LAMP assay so that the tests potentially performed in higher throughput.


  • Open Access

    Comparative analysis of primer-probe sets for the laboratory confirmation of SARS-CoV-2

    by Yu Jin Jung, Gun-Soo Park, Jun Hye Moon, Keunbon Ku, Seung-Hwa Beak, Seil Kim, Edmond Changkyun Park, Daeui Park, Jong-Hwan Lee, Cheol Woo Byeon, et al.

    Coronavirus disease 2019 (COVID-19) is newly emerging human infectious diseases, which is caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2, also previously known as 2019-nCoV). Within two months of the outbreak, more than 80,000 cases of COVID-19 have been confirmed worldwide. Since the human to human transmission occurred easily and the human infection is rapidly increasing, the sensitive and early diagnosis is essential to prevent the global outbreak. Recently, World Health Organization (WHO) announced various primer and probe sets for SARS-CoV-2 previously developed in China, Germany, Hong Kong, Japan, Thailand, and USA. In this study, we compared the ability to detect SARS-CoV-2 RNA among the seven primer-probe sets for N gene and the three primer-probe sets for Orf1 gene. The result of the comparative analysis represented that the ‘2019-nCoV_N2, N3’ of USA and the ‘ORF1ab’ of China are the most sensitive primer-probe sets for N and Orf1 genes, respectively. Therefore, the appropriate combination from ORF1ab (China), 2019-nCoV_N2, N3 (USA), and NIID_2019-nCOV_N (Japan) sets should be selected for the sensitive and reliable laboratory confirmation of SARS-CoV-2.


  • Colorimetric RT-LAMP Methods to Detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)

    by Gun-Soo Park, Seung-Hwa Baek, Keunbon Ku, Seong Jun Kim, Seung Il Kim, Bum-Tae Kim, Jin-Soo Maeng

    Standard diagnostic methods of Coronavirus Disease 2019 (COVID-19) rely on RT-qPCR technique which have limited point-of-care test (POCT) potential due to necessity of dedicated equipment and specialized personnel. LAMP, an isothermal nucleic acid amplification test (NAAT), is a promising technique that may substitute RT-qPCR for POCT of genomic materials. Here, we provide a protocol to perform reverse transcription LAMP targeting SARS-CoV-2. We adopted both real-time fluorescence detection and end-point colorimetric detection approaches. Our protocol would be useful for screening diagnosis of COVID-19 and be a baseline for development of improved POCT NAAT., [摘要] 2019年冠状病毒病的标准诊断方法(COVID-19)依靠RT-qPCR技术,由于需要专用设备和专门人员,因此具有有限的即时检验(POCT)潜力。LAMP是一种等温核酸扩增测试(NAAT),是一种有前途的技术,可以用RT-qPCR代替基因组材料的POCT。在这里,我们提供了一种执行针对SARS-CoV-2的逆转录LAMP的协议。我们同时采用了实时荧光检测和终点比色检测方法。我们的协议对于筛查COVID-19的诊断将是有用的,并且是开发改进的POCT NAAT的基线。[背景]快速和SARS-CoV的-2,COVID-19的病原的灵敏检测,重要的是要控制电流大流行的情况,因为它使得早期检测,隔离和治疗以及监测筛选。按照世界卫生组织的建议,当前用于检测SARS-CoV-2的标准方法采用RT-qPCR (世界卫生组织,2020年)。然而,RT-qPCR诊断的正确执行需要高水平的设施和专家,通常在医院/采样场所无法获得,因此缺乏POCT适用性。由于等温扩增方法可以用相对简单的仪器进行检测,因此开发了等温扩增方法以通过在各种现场即时检测核酸来完成诊断(Niemz et al。,2011)。环介导的等温扩增(LAMP)是这样的等温NAAT之一(Notomi等,2000)。LAMP反应的扩增可以通过使用实时PCR仪器的荧光染料(Oscorbin等,2016)或通过具有成本效益的比色检测方法(Goto等,2009; Miyamoto等,2015; Tanner等)进行观察。。,2015) 。实际上,反转录LAMP(RT-LAMP)可以被认为是有前途的工具,因为其他几个小组正在使用该技术进行SARS-CoV-2检测(Yan等,2020; Zhang等,2020)。在这里,我们介绍了用于开发RT-LAMP的协议,如针对SARS-CoV-2所述。候补引台正在使用基于Web的工具PrimerExplorerV5(设计https://primerexplorer.jp/e/)针对SARS冠状病毒-2特定区域比较SARS- CoV的和SARS-COV-2核衣壳。通过实时荧光法筛选引物组的检测限和阈值时间。以下所示方案包括RNA标准制备,在引物筛选过程中使用的培养病毒RNA滴定和LAMP反应(图1)。代表性地提供了最终选择的两个引物对的最佳RT-LAMP条件,即“ Nsp3_1-61”和“ Nsp3_2-24”。我们还采用了针对Bst 3.0缓冲系统优化的无色结晶紫(LCV)比色检测方法(Miyamoto等,2015)。市售的比色RT-LAMP预混合物使用pH敏感染料,因此该预混合物与影响弱缓冲反应溶液pH的病毒基因组提取方法不兼容(Lalli等,2020)。但是,LCV方法与这种病毒基因组提取方法兼容,因为颜色变化取决于dsDNA产物。 图1 。协议概述