Timothy P. Wilson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Timothy P. Wilson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jennifer L. Shourds3 shared publications
- Alex R. Fiore
US Geological Survey, New Jersey Water Science Center
1 shared publication - Cherie V. Miller1 shared publication
Evan A. Lechner
1 shared publication- Thomas E. Imbrigiotta
Program of Interdisciplinary Research in Contaminant Hydrogeology, Department of Civil Engineering, University of Virginia, Charlottesville, Virginia 22903-2442, and U.S. Geological Survey, 810 Bear Tavern Road, Suite 206, West Trenton, New Jersey 08628
1 shared publication Vincent DePaul
U.S. Geological Survey, Lawrenceville, New Jersey 08648, U.S.A.
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by US Geological Survey
Guidelines for the use of automatic samplers in collecting surface-water quality and sediment data
The importance of fluvial systems in the transport of sediment, dissolved and suspended contaminants, nutrients, and bacteria through the environment is well established. The U.S. Environmental Protection Agency (EPA) identifies sediment as the single most widespread water contaminant affecting the beneficial uses of the Nation’s rivers and streams. The evaluation of water-quality as it relates to agriculture, urbanization, highway and residential construction, mining, industrial and human wastes, and other activities requires an extensive data and sample-collection effort. This is especially the case when studying urbanized river basins, where during hydrologic events, concentration of suspended sediment and contaminants can vary rapidly and over large ranges. Where synoptic studies of watersheds are called for, sampling may be needed at many sites throughout the basin; a complicated and difficult task in some settings. Automatic pumping samplers (autosamplers) are one method for conducting intensive time-varying sampling throughout watersheds.This report presents guidelines for the use of autosamplers for collecting surface-water samples by the U.S. Geological Survey. An autosampler is an automatic, pump-based sampler that collects a prescribed volume of water from streams, lakes, reservoirs, storm drains, or other bodies of water after receiving a command from an internal or external control unit. It deposits this sample into a specified container for later analysis of physical, chemical, or biological constituents. This report provides a general background on types of autosamplers and how they work; guidance for designing, selecting, installing, servicing, and calibrating autosamplers; guidance on standardized operating procedures, and guidance on quality-assurance and quality-control efforts when using an autosampler.
- 1 January 2024
- Published by US Geological Survey
Open AccessGuidelines for the use of automatic samplers in collecting surface-water quality and sediment data
The importance of fluvial systems in the transport of sediment, dissolved and suspended contaminants, nutrients, and bacteria through the environment is well established. The U.S. Environmental Protection Agency (EPA) identifies sediment as the single most widespread water contaminant affecting the beneficial uses of the Nation’s rivers and streams. The evaluation of water-quality as it relates to agriculture, urbanization, highway and residential construction, mining, industrial and human wastes, and other activities requires an extensive data and sample-collection effort. This is especially the case when studying urbanized river basins, where during hydrologic events, concentration of suspended sediment and contaminants can vary rapidly and over large ranges. Where synoptic studies of watersheds are called for, sampling may be needed at many sites throughout the basin; a complicated and difficult task in some settings. Automatic pumping samplers (autosamplers) are one method for conducting intensive time-varying sampling throughout watersheds.This report presents guidelines for the use of autosamplers for collecting surface-water samples by the U.S. Geological Survey. An autosampler is an automatic, pump-based sampler that collects a prescribed volume of water from streams, lakes, reservoirs, storm drains, or other bodies of water after receiving a command from an internal or external control unit. It deposits this sample into a specified container for later analysis of physical, chemical, or biological constituents. This report provides a general background on types of autosamplers and how they work; guidance for designing, selecting, installing, servicing, and calibrating autosamplers; guidance on standardized operating procedures, and guidance on quality-assurance and quality-control efforts when using an autosampler.
- Open Access
- 1 January 2023
- Published by US Geological Survey
Distribution of chlorinated volatile organic compounds and per- and polyfluoroalkyl substances in groundwater and surface water at the former Naval Air Warfare Center, West Trenton, New Jersey, 2018
Groundwater wells and surface-water storm sewers contaminated with volatile organic compounds (VOCs) and per- and polyfluoroalkyl substances (PFASs) at the former Naval Air Warfare Center (NAWC) site in West Trenton, New Jersey were sampled in 2018 as part of the Navy’s long-term monitoring program. Trichloroethene (TCE), cis-1,2-dichloroethene (cisDCE), and vinyl chloride concentrations were plotted in map view and selected cross sections to elucidate the vertical and horizontal extent and distribution of contamination, along with a tabular comparison between 2018 and previous analytical results. The 2018 data showed that the areas of VOC contamination (>1 microgram per liter) decreased slightly on the north and east sides of the NAWC site from previous sampling dates; these decreases are attributed to the influence of the pump-and-treat system, natural attenuation processes, and various engineered bioaugmentation experiments that have occurred onsite. Off-site groundwater samples indicate the VOC contaminated groundwater is likely hydraulically constrained by the pump-and-treat system and appears to not be moving offsite to the south and west of NAWC. Only one offsite well, 50BR, located along the eastern margin of the site, was found to have detectable TCE and cisDCE concentrations, indicating that VOC contamination continues to migrate a short distance offsite to the east. Detectable VOC contamination was found in wells as deep as 200 and 221 feet on both the east and west sides of the NAWC site. Comparisons of present-day data to data from past sampling efforts indicate that TCE concentrations in most wells have decreased slowly over time.Results from surface-water samples indicate that VOCs enter surface water predominantly through the West Ditch drainage system. Concentrations and fluxes of VOCs are higher when groundwater levels are higher, indicating contaminated groundwater discharges into the surface water system. Higher VOC concentrations at the Interceptor site relative to other sites in the West Ditch indicate the contamination in the West Ditch system is likely caused by contaminated groundwater discharging to the West Ditch storm sewer near manhole MH-140 when water table levels are high.The pump-and-treat extraction wells at the former NAWC site were sampled for per- and polyfluoroalkyl substances (PFAS) in 2018. The suite of reported PFAS include perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorononanoic acid, and perfluorobutane sulfonate. Concentrations were plotted in map view to determine the areal extent of the PFAS contamination at the site. Extraction well 48BR sampled on the eastern half of the site was found to have PFOS and PFOA concentrations greater than the New Jersey Department of Environmental Protection Drinking Water maximum contaminant levels (MCLs), which is consistent with the distribution of highest PFAS concentrations in surface water in the OF-4 storm sewer system that drains that area, as well as previously collected PFAS concentrations in monitoring wells. On the western half of the site, the extraction well 08BR sample exceeded MCLs for PFOA and PFOS and the extraction well 22BR sample exceeded the MCL for PFOA, but samples from all other extraction wells were below the MCLs or other criteria for all PFAS analyzed. Concentrations of PFOA exceeded concentrations of PFOS on the west side of NAWC in both groundwater and surface water, which contrasts with the conditions on the east side of NAWC where PFOS concentrations exceeded PFOA concentrations. However, this observation was based on a limited number of samples on the west side of NAWC from 2018 and previous years, so more PFAS sampling is needed on the west side to assess this further.
- 1 January 2023
- Published by US Geological Survey
Open AccessDistribution of chlorinated volatile organic compounds and per- and polyfluoroalkyl substances in groundwater and surface water at the former Naval Air Warfare Center, West Trenton, New Jersey, 2018
Groundwater wells and surface-water storm sewers contaminated with volatile organic compounds (VOCs) and per- and polyfluoroalkyl substances (PFASs) at the former Naval Air Warfare Center (NAWC) site in West Trenton, New Jersey were sampled in 2018 as part of the Navy’s long-term monitoring program. Trichloroethene (TCE), cis-1,2-dichloroethene (cisDCE), and vinyl chloride concentrations were plotted in map view and selected cross sections to elucidate the vertical and horizontal extent and distribution of contamination, along with a tabular comparison between 2018 and previous analytical results. The 2018 data showed that the areas of VOC contamination (>1 microgram per liter) decreased slightly on the north and east sides of the NAWC site from previous sampling dates; these decreases are attributed to the influence of the pump-and-treat system, natural attenuation processes, and various engineered bioaugmentation experiments that have occurred onsite. Off-site groundwater samples indicate the VOC contaminated groundwater is likely hydraulically constrained by the pump-and-treat system and appears to not be moving offsite to the south and west of NAWC. Only one offsite well, 50BR, located along the eastern margin of the site, was found to have detectable TCE and cisDCE concentrations, indicating that VOC contamination continues to migrate a short distance offsite to the east. Detectable VOC contamination was found in wells as deep as 200 and 221 feet on both the east and west sides of the NAWC site. Comparisons of present-day data to data from past sampling efforts indicate that TCE concentrations in most wells have decreased slowly over time.Results from surface-water samples indicate that VOCs enter surface water predominantly through the West Ditch drainage system. Concentrations and fluxes of VOCs are higher when groundwater levels are higher, indicating contaminated groundwater discharges into the surface water system. Higher VOC concentrations at the Interceptor site relative to other sites in the West Ditch indicate the contamination in the West Ditch system is likely caused by contaminated groundwater discharging to the West Ditch storm sewer near manhole MH-140 when water table levels are high.The pump-and-treat extraction wells at the former NAWC site were sampled for per- and polyfluoroalkyl substances (PFAS) in 2018. The suite of reported PFAS include perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorononanoic acid, and perfluorobutane sulfonate. Concentrations were plotted in map view to determine the areal extent of the PFAS contamination at the site. Extraction well 48BR sampled on the eastern half of the site was found to have PFOS and PFOA concentrations greater than the New Jersey Department of Environmental Protection Drinking Water maximum contaminant levels (MCLs), which is consistent with the distribution of highest PFAS concentrations in surface water in the OF-4 storm sewer system that drains that area, as well as previously collected PFAS concentrations in monitoring wells. On the western half of the site, the extraction well 08BR sample exceeded MCLs for PFOA and PFOS and the extraction well 22BR sample exceeded the MCL for PFOA, but samples from all other extraction wells were below the MCLs or other criteria for all PFAS analyzed. Concentrations of PFOA exceeded concentrations of PFOS on the west side of NAWC in both groundwater and surface water, which contrasts with the conditions on the east side of NAWC where PFOS concentrations exceeded PFOA concentrations. However, this observation was based on a limited number of samples on the west side of NAWC from 2018 and previous years, so more PFAS sampling is needed on the west side to assess this further.
- 1 January 2020
- Published by US Geological Survey
Sediment and chemical contaminant loads in tributaries to the Anacostia River, Washington, District of Columbia, 2016–17
First posted February 28, 2020 Director, MD-DE-DC Water Science Center U.S. Geological Survey 5522 Research Park Drive Baltimore, MD 21228 A study was conducted by the U.S. Geological Survey (USGS) in cooperation with the Washington, D.C., Department of Energy & Environment to estimate the loads of suspended-sediment-bound chemical compounds in five gaged tributaries and four ungaged tributaries of the Anacostia River (known locally as “Lower Anacostia River”) in Washington, D.C. Tributaries whose discharge is measured by the USGS are the Northeast and Northwest Branches of the Anacostia River, referred to in this report as “Northeast Branch” (NEB) and “Northwest Branch” (NWB), respectively; Watts Branch (WB); and Hickey Run (HR). A USGS streamflow-gaging station was established in 2016 on Beaverdam Creek (known locally as “Lower Beaverdam Creek” [LBDC]) to support this study. The ungaged streams studied include Nash Run; Pope Branch; an unnamed stream at Fort DuPont, referred to in this report as “Fort DuPont Creek”; and an unnamed stream at Fort Stanton, referred to in this report as “Fort Stanton Creek.” The gaged streams were sampled during four to five storms and two low-flow events during January, March, May, and July 2017. The ungaged streams were sampled during one storm and one low-flow event during July 2017. Storm sampling involved collecting large-volume (60- to 70-liter) composite samples, then removing sediment by filtration in the laboratory. Low-flow samples were obtained by filtering streamwater directly in the field. Continuously recording data sondes were deployed throughout the study to measure turbidity and other water-quality characteristics. During sampling, multiple discrete samples of streamwater were collected to determine suspended-sediment concentration (SSC) and particulate organic carbon (POC) concentration. Shortly after each storm, bed sediment was collected for chemical analysis. Sediment samples were analyzed for 209 polychlorinated biphenyl (PCB) congeners; 35 polyaromatic hydrocarbon (PAH) compounds, including 20 nonalkylated and 15 alkylated species; and 20 organochlorine pesticide (OP) compounds. Sediment from one storm was analyzed for 23 metals. Relations were developed among turbidity, discharge, and measured SSC by using multiple linear regression of log-transformed data. These relations were used to estimate SSC from continuous records of discharge and turbidity and were subsequently used to estimate sediment loads for the 2017 calendar year. USGS continuous records of turbidity in NEB, NWB, Watts Branch, and Hickey Run were available for 2013–17, which allowed sediment loads to be calculated for these years. Sediment loads for the ungaged streams were estimated by using loads measured in Watts Branch adjusted on the basis of stream-basin areas. Sediment loads for 2017 total 3.10×107 kilograms (kg), with 1.02×107 kg (33 percent of total) from the NEB, 1.55×107 kg (50 percent) from the NWB, 4.45×106 kg (14 percent) from LBDC, 5.62×105 kg (2 percent) from Watts Branch, and 2.82×105 kg (1 percent) from Hickey Run. Sediment yields were highest from NWB and LBDC (3.13×105 kilograms per year per square mile [kg/yr/mi2] and 3.01 kg/yr/mi2, respectively). As a result of gaps in turbidity and discharge data, the load for LBDC reported here was calculated from measurements representing only 88 percent of the year (2017), and thus underestimates the actual load. All other gaged tributaries had datasets covering 100 percent of the year and are considered to fully represent actual loads. Estimated sediment loads for the ungaged streams during 2017 total 3.5×105 kg, with 1.2×105 kg from Nash Run, 6.2×104 kg from Pope Branch, 1.1×105 kg from Fort DuPont Creek, and 5.6×104 kg from Fort Stanton Creek. Concentrations of PCBs, PAHs, and chlorinated pesticides in streamwater are presented for stormflow and low-flow conditions. Average concentrations (in stormflow and low-flow samples) of total PCBs (sum of all congeners, including coelutions) are 5.9 micrograms per kilogram (µg/kg) for NEB, 6.6 µg/kg for NWB, 130 µg/kg for LBDC, 34 µg/kg for Watts Branch, and 69 µg/kg for Hickey Run. Average concentrations of total PAHs (tPAH) (total of nonalkylated and alkylated species) are 2,000 µg/kg for NEB, 3,300 µg/kg for NWB, 2,200 µg/kg for LBDC, 2,400 µg/kg for Watts Branch, and 18,000 µg/kg for Hickey Run. tPAH concentrations among the ungaged streams were highest in Nash Run (5,500 µg/kg); concentrations in the other ungaged streams were less than (<) 700 µg/kg. The general magnitude of tPCB and tPAH concentrations in streamwater samples was low-flow samples greater than (>) stormflow samples greater than or equal to (≥) bed-sediment samples. PCB congener profiles in the three types of samples were nearly identical in each stream and were similar in all streams except for LBDC, where the dominant PCBs shifted to the lighter di- through tetra- homologs. LBDC showed higher tPCB concentrations and a distinct congener profile from the other streams. The similarity in congener makeup supported that averaging PCB concentrations in stormflow and low-flow samples was appropriate for calculating chemical loads. Loads of tPCB, tPAH (total of alkylated and nonalkylated forms), and pesticides were estimated for each stream by multiplying average contaminant concentrations by the respective sediment loads. Total PCB loads for 2017 were estimated to be 820 grams (g) with 8 percent (60 g) from NEB, 12 percent (95 g) from NWB, 75 percent (590 g) from LBDC, 3 percent (25 g) from Watts Branch, and 2.5 percent (19 g)...
- 1 January 2020
- Published by US Geological Survey
Sediment and chemical contaminant loads in tributaries to the Anacostia River, Washington, District of Columbia, 2016–17
First posted February 28, 2020 Director, MD-DE-DC Water Science Center U.S. Geological Survey 5522 Research Park Drive Baltimore, MD 21228 A study was conducted by the U.S. Geological Survey (USGS) in cooperation with the Washington, D.C., Department of Energy & Environment to estimate the loads of suspended-sediment-bound chemical compounds in five gaged tributaries and four ungaged tributaries of the Anacostia River (known locally as “Lower Anacostia River”) in Washington, D.C. Tributaries whose discharge is measured by the USGS are the Northeast and Northwest Branches of the Anacostia River, referred to in this report as “Northeast Branch” (NEB) and “Northwest Branch” (NWB), respectively; Watts Branch (WB); and Hickey Run (HR). A USGS streamflow-gaging station was established in 2016 on Beaverdam Creek (known locally as “Lower Beaverdam Creek” [LBDC]) to support this study. The ungaged streams studied include Nash Run; Pope Branch; an unnamed stream at Fort DuPont, referred to in this report as “Fort DuPont Creek”; and an unnamed stream at Fort Stanton, referred to in this report as “Fort Stanton Creek.” The gaged streams were sampled during four to five storms and two low-flow events during January, March, May, and July 2017. The ungaged streams were sampled during one storm and one low-flow event during July 2017. Storm sampling involved collecting large-volume (60- to 70-liter) composite samples, then removing sediment by filtration in the laboratory. Low-flow samples were obtained by filtering streamwater directly in the field. Continuously recording data sondes were deployed throughout the study to measure turbidity and other water-quality characteristics. During sampling, multiple discrete samples of streamwater were collected to determine suspended-sediment concentration (SSC) and particulate organic carbon (POC) concentration. Shortly after each storm, bed sediment was collected for chemical analysis. Sediment samples were analyzed for 209 polychlorinated biphenyl (PCB) congeners; 35 polyaromatic hydrocarbon (PAH) compounds, including 20 nonalkylated and 15 alkylated species; and 20 organochlorine pesticide (OP) compounds. Sediment from one storm was analyzed for 23 metals. Relations were developed among turbidity, discharge, and measured SSC by using multiple linear regression of log-transformed data. These relations were used to estimate SSC from continuous records of discharge and turbidity and were subsequently used to estimate sediment loads for the 2017 calendar year. USGS continuous records of turbidity in NEB, NWB, Watts Branch, and Hickey Run were available for 2013–17, which allowed sediment loads to be calculated for these years. Sediment loads for the ungaged streams were estimated by using loads measured in Watts Branch adjusted on the basis of stream-basin areas. Sediment loads for 2017 total 3.10×107 kilograms (kg), with 1.02×107 kg (33 percent of total) from the NEB, 1.55×107 kg (50 percent) from the NWB, 4.45×106 kg (14 percent) from LBDC, 5.62×105 kg (2 percent) from Watts Branch, and 2.82×105 kg (1 percent) from Hickey Run. Sediment yields were highest from NWB and LBDC (3.13×105 kilograms per year per square mile [kg/yr/mi2] and 3.01 kg/yr/mi2, respectively). As a result of gaps in turbidity and discharge data, the load for LBDC reported here was calculated from measurements representing only 88 percent of the year (2017), and thus underestimates the actual load. All other gaged tributaries had datasets covering 100 percent of the year and are considered to fully represent actual loads. Estimated sediment loads for the ungaged streams during 2017 total 3.5×105 kg, with 1.2×105 kg from Nash Run, 6.2×104 kg from Pope Branch, 1.1×105 kg from Fort DuPont Creek, and 5.6×104 kg from Fort Stanton Creek. Concentrations of PCBs, PAHs, and chlorinated pesticides in streamwater are presented for stormflow and low-flow conditions. Average concentrations (in stormflow and low-flow samples) of total PCBs (sum of all congeners, including coelutions) are 5.9 micrograms per kilogram (µg/kg) for NEB, 6.6 µg/kg for NWB, 130 µg/kg for LBDC, 34 µg/kg for Watts Branch, and 69 µg/kg for Hickey Run. Average concentrations of total PAHs (tPAH) (total of nonalkylated and alkylated species) are 2,000 µg/kg for NEB, 3,300 µg/kg for NWB, 2,200 µg/kg for LBDC, 2,400 µg/kg for Watts Branch, and 18,000 µg/kg for Hickey Run. tPAH concentrations among the ungaged streams were highest in Nash Run (5,500 µg/kg); concentrations in the other ungaged streams were less than (<) 700 µg/kg. The general magnitude of tPCB and tPAH concentrations in streamwater samples was low-flow samples greater than (>) stormflow samples greater than or equal to (≥) bed-sediment samples. PCB congener profiles in the three types of samples were nearly identical in each stream and were similar in all streams except for LBDC, where the dominant PCBs shifted to the lighter di- through tetra- homologs. LBDC showed higher tPCB concentrations and a distinct congener profile from the other streams. The similarity in congener makeup supported that averaging PCB concentrations in stormflow and low-flow samples was appropriate for calculating chemical loads. Loads of tPCB, tPAH (total of alkylated and nonalkylated forms), and pesticides were estimated for each stream by multiplying average contaminant concentrations by the respective sediment loads. Total PCB loads for 2017 were estimated to be 820 grams (g) with 8 percent (60 g) from NEB, 12 percent (95 g) from NWB, 75 percent (590 g) from LBDC, 3 percent (25 g) from Watts Branch, and 2.5 percent (19 g)...
- 1 October 2017
- Published by Coastal Education and Research Foundation in Journal of Coastal Research
- Vol. 78 (sp1) , 46
In Situ Benthic Nutrient Flux and Sediment Oxygen Demand in Barnegat Bay, New Jersey
Wilson, T. and DePaul, V., 2017. In situ benthic nutrient flux and sediment oxygen demand in Barnegat Bay, New Jersey. In: Buchanan, G.A.; Belton, T.J., and Paudel, B. (eds.), A Comprehensive Assessment of Barnegat Bay-Little Egg Harbor, New Jersey. The U.S. Geological Survey, in cooperation with the New Jersey Department of Environmental Protection, measured sediment oxygen demand (SOD) and benthic nutrient fluxes throughout Barnegat Bay, New Jersey. SOD was determined in situ using chambers equipped with optical dissolved oxygen sensors. The benthic nutrient fluxes of ammonia (NH3), nitrite + nitrate ( plus ions; here, referred to as NO32), soluble reactive phosphorous (SRP), and dissolved silica (SiO2) were measured with in situ equilibrium dialysis samplers. Measurements were made at nine stations around the periphery and at three mid-Bay locations from August 2012 to October 2013. The SOD ranged from −1.5 to −8.4 g of oxygen (O2) m−2 d−1. The SOD rates varied as a function of water temperatu...
- 1 October 2017
- Published by Coastal Education and Research Foundation in Journal of Coastal Research
- Vol. 78 (sp1) , 46
In Situ Benthic Nutrient Flux and Sediment Oxygen Demand in Barnegat Bay, New Jersey
Wilson, T. and DePaul, V., 2017. In situ benthic nutrient flux and sediment oxygen demand in Barnegat Bay, New Jersey. In: Buchanan, G.A.; Belton, T.J., and Paudel, B. (eds.), A Comprehensive Assessment of Barnegat Bay-Little Egg Harbor, New Jersey. The U.S. Geological Survey, in cooperation with the New Jersey Department of Environmental Protection, measured sediment oxygen demand (SOD) and benthic nutrient fluxes throughout Barnegat Bay, New Jersey. SOD was determined in situ using chambers equipped with optical dissolved oxygen sensors. The benthic nutrient fluxes of ammonia (NH3), nitrite + nitrate ( plus ions; here, referred to as NO32), soluble reactive phosphorous (SRP), and dissolved silica (SiO2) were measured with in situ equilibrium dialysis samplers. Measurements were made at nine stations around the periphery and at three mid-Bay locations from August 2012 to October 2013. The SOD ranged from −1.5 to −8.4 g of oxygen (O2) m−2 d−1. The SOD rates varied as a function of water temperatu...
- 1 January 2008
- Published by US Geological Survey
Occurrence of organic compounds and trace elements in the upper Passaic and Elizabeth Rivers and their tributaries in New Jersey, July 2003 to February 2004: Phase II of the New Jersey toxics reduction workplan for New York-New Jersey Harbor
Samples of surface water and suspended sediment were collected from the Passaic and Elizabeth Rivers and their tributaries in New Jersey from July 2003 to February 2004 to determine the concentrations of selected chlorinated organic and inorganic constituents. This sampling and analysis was conducted as Phase II of the New York-New Jersey Harbor Estuary Workplan?Contaminant Assessment and Reduction Program (CARP), which is overseen by the New Jersey Department of Environmental Protection. Phase II of the New Jersey Workplan was conducted to define upstream tributary and point sources of contaminants in those rivers sampled during Phase I work, with special emphasis on the Passaic and Elizabeth Rivers. Samples were collected from three groups of tributaries: (1) the Second, Third, and Saddle Rivers; (2) the Pompton and upper Passaic Rivers; and (3) the West Branch and main stem of the Elizabeth River. The Second, Third, and Saddle Rivers were sampled near their confluence with the tidal Passaic River, but at locations not affected by tidal flooding. The Pompton and upper Passaic Rivers were sampled immediately upstream from their confluence at Two Bridges, N.J. The West Branch and the main stem of the Elizabeth River were sampled just upstream from their confluence at Hillside, N.J. All tributaries were sampled during low-flow discharge conditions using the protocols and analytical methods for organic constituents used in low-flow sampling in Phase I. Grab samples of streamflow also were collected at each site and were analyzed for trace elements (mercury, methylmercury, cadmium, and lead) and for suspended sediment, particulate organic carbon, and dissolved organic carbon. The measured concentrations and available historical suspended-sediment and stream-discharge data (where available) were used to estimate average annual loads of suspended sediment and organic compounds in these rivers. Total suspended-sediment loads for 1975?2000 were estimated using rating curves developed from historical U.S. Geological Survey (USGS) suspended-sediment and discharge data, where available. Average annual loads of suspended sediment, in millions of kilograms per year (Mkg/yr), were estimated to be 0.190 for the Second River, 0.23 for the Third River, 1.00 for the Saddle River, 1.76 for the Pompton River, and 7.40 for the upper Passaic River. On the basis of the available discharge records, the upper Passaic River was estimated to provide approximately 60 percent of the water and 80 percent of the total suspended-sediment load at the Passaic River head-of-tide, whereas the Pompton River provided roughly 20 percent of the total suspended-sediment load estimated at the head-of-tide. The combined suspended-sediment loads of the upper Passaic and Pompton Rivers (9.2 Mkg/yr), however, represent only 40 percent of the average annual suspended-sediment load estimated for the head-of-tide (23 Mkg/yr) at Little Falls, N.J. The difference between the combined suspended-sediment loads of the tributaries and the estimated load at Little Falls represents either sediment trapped upriver from the dam at Little Falls, additional inputs of suspended sediment downstream from the tributary confluence, or uncertainty in the suspended-sediment and discharge data that were used. The concentrations of total suspended sediment-bound polychlorinated biphenyls (PCBs) in the tributaries to the Passaic River were 194 ng/g (nanograms per gram) in the Second River, 575 ng/g in the Third River, 2,320 ng/g in the Saddle River, 200 ng/g in the Pompton River, and 87 ng/g in the upper Passic River. The dissolved PCB concentrations in the tributaries were 563 pg/L (picograms per liter) in the Second River, 2,510 pg/L in the Third River, 2,270 pg/L in the Saddle River, 887 pg/L in the Pompton River, and 1,000 pg/L in the upper Passaic River. Combined with the sediment loads and discharge, these concentrations resulted in annual loads of suspended sediment-bound PCBs, i
- 1 January 2008
- Published by US Geological Survey
Occurrence of organic compounds and trace elements in the upper Passaic and Elizabeth Rivers and their tributaries in New Jersey, July 2003 to February 2004: Phase II of the New Jersey toxics reduction workplan for New York-New Jersey Harbor
Samples of surface water and suspended sediment were collected from the Passaic and Elizabeth Rivers and their tributaries in New Jersey from July 2003 to February 2004 to determine the concentrations of selected chlorinated organic and inorganic constituents. This sampling and analysis was conducted as Phase II of the New York-New Jersey Harbor Estuary Workplan?Contaminant Assessment and Reduction Program (CARP), which is overseen by the New Jersey Department of Environmental Protection. Phase II of the New Jersey Workplan was conducted to define upstream tributary and point sources of contaminants in those rivers sampled during Phase I work, with special emphasis on the Passaic and Elizabeth Rivers. Samples were collected from three groups of tributaries: (1) the Second, Third, and Saddle Rivers; (2) the Pompton and upper Passaic Rivers; and (3) the West Branch and main stem of the Elizabeth River. The Second, Third, and Saddle Rivers were sampled near their confluence with the tidal Passaic River, but at locations not affected by tidal flooding. The Pompton and upper Passaic Rivers were sampled immediately upstream from their confluence at Two Bridges, N.J. The West Branch and the main stem of the Elizabeth River were sampled just upstream from their confluence at Hillside, N.J. All tributaries were sampled during low-flow discharge conditions using the protocols and analytical methods for organic constituents used in low-flow sampling in Phase I. Grab samples of streamflow also were collected at each site and were analyzed for trace elements (mercury, methylmercury, cadmium, and lead) and for suspended sediment, particulate organic carbon, and dissolved organic carbon. The measured concentrations and available historical suspended-sediment and stream-discharge data (where available) were used to estimate average annual loads of suspended sediment and organic compounds in these rivers. Total suspended-sediment loads for 1975?2000 were estimated using rating curves developed from historical U.S. Geological Survey (USGS) suspended-sediment and discharge data, where available. Average annual loads of suspended sediment, in millions of kilograms per year (Mkg/yr), were estimated to be 0.190 for the Second River, 0.23 for the Third River, 1.00 for the Saddle River, 1.76 for the Pompton River, and 7.40 for the upper Passaic River. On the basis of the available discharge records, the upper Passaic River was estimated to provide approximately 60 percent of the water and 80 percent of the total suspended-sediment load at the Passaic River head-of-tide, whereas the Pompton River provided roughly 20 percent of the total suspended-sediment load estimated at the head-of-tide. The combined suspended-sediment loads of the upper Passaic and Pompton Rivers (9.2 Mkg/yr), however, represent only 40 percent of the average annual suspended-sediment load estimated for the head-of-tide (23 Mkg/yr) at Little Falls, N.J. The difference between the combined suspended-sediment loads of the tributaries and the estimated load at Little Falls represents either sediment trapped upriver from the dam at Little Falls, additional inputs of suspended sediment downstream from the tributary confluence, or uncertainty in the suspended-sediment and discharge data that were used. The concentrations of total suspended sediment-bound polychlorinated biphenyls (PCBs) in the tributaries to the Passaic River were 194 ng/g (nanograms per gram) in the Second River, 575 ng/g in the Third River, 2,320 ng/g in the Saddle River, 200 ng/g in the Pompton River, and 87 ng/g in the upper Passic River. The dissolved PCB concentrations in the tributaries were 563 pg/L (picograms per liter) in the Second River, 2,510 pg/L in the Third River, 2,270 pg/L in the Saddle River, 887 pg/L in the Pompton River, and 1,000 pg/L in the upper Passaic River. Combined with the sediment loads and discharge, these concentrations resulted in annual loads of suspended sediment-bound PCBs, i
- 1 January 2007
- Published by US Geological Survey
Concentrations and Loads of Organic Compounds and Trace Elements in Tributaries to Newark and Raritan Bays, New Jersey
Flood of April 2-4, 2005, Delaware River Main Stem from Port Jervis, New York, to Cinnaminson, New Jersey
- 1 January 2007
- Published by US Geological Survey
Concentrations and Loads of Organic Compounds and Trace Elements in Tributaries to Newark and Raritan Bays, New Jersey
Flood of April 2-4, 2005, Delaware River Main Stem from Port Jervis, New York, to Cinnaminson, New Jersey
- 1 January 2006
- Published by US Geological Survey
Organic Compounds, Trace Elements, Suspended Sediment, and Field Characteristics at the Heads-of-Tide of the Raritan, Passaic, Hackensack, Rahway, and Elizabeth Rivers, New Jersey, 2000-03
Organic Compounds, Trace Elements, Suspended Sediment, and Field Characteristics at the Heads-of-Tide of the Raritan, Passaic, Hackensack, Rahway, and Elizabeth Rivers, New Jersey, 2000-03
- 1 January 2006
- Published by US Geological Survey
Organic Compounds, Trace Elements, Suspended Sediment, and Field Characteristics at the Heads-of-Tide of the Raritan, Passaic, Hackensack, Rahway, and Elizabeth Rivers, New Jersey, 2000-03
Organic Compounds, Trace Elements, Suspended Sediment, and Field Characteristics at the Heads-of-Tide of the Raritan, Passaic, Hackensack, Rahway, and Elizabeth Rivers, New Jersey, 2000-03