Wenzhuo Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenzhuo Yu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Sam Emaminejad
University of California, Los Angeles (UCLA)
8 shared publications - Haisong Lin
School of Engineering, Westlake University, Hangzhou, China
6 shared publications - Bo Wang
Interconnected & Integrated Bioelectronics Lab (I2BL) Department of Electrical and Computer Engineering University of California Los Angeles CA 90095 USA
5 shared publications - Shuyu Lin
Interconnected & Integrated Bioelectronics Lab (I2BL) Department of Electrical and Computer Engineering University of California Los Angeles CA 90095 USA
5 shared publications - Xuanbing Cheng
Interconnected and Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, Samueli School of Engineering, University of California, Los Angeles, Los Angeles, CA 90095,USA
5 shared publications - Hannaneh Hojaiji
Interconnected & Integrated Bioelectronics Lab (I2BL), Department of Electrical and Computer Engineering, University of California, Los Angeles, CA 90095
4 shared publications
Latest Publications
- Open Access
- 9 November 2022
- Published by Springer Nature in Nature
- Vol. 611 (7936) , 570-577
Ferrobotic swarms enable accessible and adaptable automated viral testing
Expanding our global testing capacity is critical to preventing and containing pandemics1,2,3,4,5,6,7,8,9. Accordingly, accessible and adaptable automated platforms that in decentralized settings perform nucleic acid amplification tests resource-efficiently are required10,11,12,13,14. Pooled testing can be extremely efficient if the pooling strategy is based on local viral prevalence15,16,17,18,19,20; however, it requires automation, small sample volume handling and feedback not available in current bulky, capital-intensive liquid handling technologies21,22,23,24,25,26,27,28,29. Here we use a swarm of millimetre-sized magnets as mobile robotic agents (‘ferrobots’) for precise and robust handling of magnetized sample droplets and high-fidelity delivery of flexible workflows based on nucleic acid amplification tests to overcome these limitations. Within a palm-sized printed circuit board-based programmable platform, we demonstrated the myriad of laboratory-equivalent operations involved in pooled testing. These operations were guided by an introduced square matrix pooled testing algorithm to identify the samples from infected patients, while maximizing the testing efficiency. We applied this automated technology for the loop-mediated isothermal amplification and detection of the SARS-CoV-2 virus in clinical samples, in which the test results completely matched those obtained off-chip. This technology is easily manufacturable and distributable, and its adoption for viral testing could lead to a 10–300-fold reduction in reagent costs (depending on the viral prevalence) and three orders of magnitude reduction in instrumentation cost. Therefore, it is a promising solution to expand our testing capacity for pandemic preparedness and to reimagine the automated clinical laboratory of the future.
- 9 November 2022
- Published by Springer Nature in Nature
- Vol. 611 (7936) , 570-577
Open AccessFerrobotic swarms enable accessible and adaptable automated viral testing
Expanding our global testing capacity is critical to preventing and containing pandemics1,2,3,4,5,6,7,8,9. Accordingly, accessible and adaptable automated platforms that in decentralized settings perform nucleic acid amplification tests resource-efficiently are required10,11,12,13,14. Pooled testing can be extremely efficient if the pooling strategy is based on local viral prevalence15,16,17,18,19,20; however, it requires automation, small sample volume handling and feedback not available in current bulky, capital-intensive liquid handling technologies21,22,23,24,25,26,27,28,29. Here we use a swarm of millimetre-sized magnets as mobile robotic agents (‘ferrobots’) for precise and robust handling of magnetized sample droplets and high-fidelity delivery of flexible workflows based on nucleic acid amplification tests to overcome these limitations. Within a palm-sized printed circuit board-based programmable platform, we demonstrated the myriad of laboratory-equivalent operations involved in pooled testing. These operations were guided by an introduced square matrix pooled testing algorithm to identify the samples from infected patients, while maximizing the testing efficiency. We applied this automated technology for the loop-mediated isothermal amplification and detection of the SARS-CoV-2 virus in clinical samples, in which the test results completely matched those obtained off-chip. This technology is easily manufacturable and distributable, and its adoption for viral testing could lead to a 10–300-fold reduction in reagent costs (depending on the viral prevalence) and three orders of magnitude reduction in instrumentation cost. Therefore, it is a promising solution to expand our testing capacity for pandemic preparedness and to reimagine the automated clinical laboratory of the future.
- Open Access
- 4 April 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (15)
A touch-based multimodal and cryptographic bio-human–machine interface
Significance: The awareness of the individuals’ biological status is critical for creating interactive environments. Accordingly, we devised a multimodal cryptographic bio-human–machine interface (CB-HMI), which seamlessly translates touch-based entries into encrypted biochemical, biophysical, and biometric indices (i.e., circulating biomarkers levels, heart rate, oxygen saturation level, and fingerprint pattern). As its central component, the CB-HMI features thin hydrogel-coated chemical sensors and a signal interpretation framework to access/interpret biochemical indices, bypassing the challenge of circulating analyte accessibility and the confounding effect of pressing force variability. Upgrading the surrounding objects with CB-HMI, we demonstrated new interactive solutions for driving safety and medication use, where the integrated CB-HMI uniquely enabled one-touch bioauthentication (based on the user’s biological state/identity), prior to rendering the intended services.
- 4 April 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (15)
Open AccessA touch-based multimodal and cryptographic bio-human–machine interface
Significance: The awareness of the individuals’ biological status is critical for creating interactive environments. Accordingly, we devised a multimodal cryptographic bio-human–machine interface (CB-HMI), which seamlessly translates touch-based entries into encrypted biochemical, biophysical, and biometric indices (i.e., circulating biomarkers levels, heart rate, oxygen saturation level, and fingerprint pattern). As its central component, the CB-HMI features thin hydrogel-coated chemical sensors and a signal interpretation framework to access/interpret biochemical indices, bypassing the challenge of circulating analyte accessibility and the confounding effect of pressing force variability. Upgrading the surrounding objects with CB-HMI, we demonstrated new interactive solutions for driving safety and medication use, where the integrated CB-HMI uniquely enabled one-touch bioauthentication (based on the user’s biological state/identity), prior to rendering the intended services.
- Top Cited PapersOpen Access
- 7 January 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (1) , eabk0967
Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring
A smartwatch was developed for noninvasive stress biomarker data acquisition that provides real-time feedback to the wearer.
- 7 January 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (1) , eabk0967
Top Cited PapersOpen AccessWearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring
A smartwatch was developed for noninvasive stress biomarker data acquisition that provides real-time feedback to the wearer.
- Open Access
- 2 September 2020
- Published by Springer Nature in Nature Communications
- Vol. 11 (1) , 1-12
A programmable epidermal microfluidic valving system for wearable biofluid management and contextual biomarker analysis
Active biofluid management is central to the realization of wearable bioanalytical platforms that are poised to autonomously provide frequent, real-time, and accurate measures of biomarkers in epidermally-retrievable biofluids (e.g., sweat). Accordingly, here, a programmable epidermal microfluidic valving system is devised, which is capable of biofluid sampling, routing, and compartmentalization for biomarker analysis. At its core, the system is a network of individually-addressable microheater-controlled thermo-responsive hydrogel valves, augmented with a pressure regulation mechanism to accommodate pressure built-up, when interfacing sweat glands. The active biofluid control achieved by this system is harnessed to create unprecedented wearable bioanalytical capabilities at both the sensor level (decoupling the confounding influence of flow rate variability on sensor response) and the system level (facilitating context-based sensor selection/protection). Through integration with a wireless flexible printed circuit board and seamless bilateral communication with consumer electronics (e.g., smartwatch), contextually-relevant (scheduled/on-demand) on-body biomarker data acquisition/display was achieved.
- 2 September 2020
- Published by Springer Nature in Nature Communications
- Vol. 11 (1) , 1-12
Open AccessA programmable epidermal microfluidic valving system for wearable biofluid management and contextual biomarker analysis
Active biofluid management is central to the realization of wearable bioanalytical platforms that are poised to autonomously provide frequent, real-time, and accurate measures of biomarkers in epidermally-retrievable biofluids (e.g., sweat). Accordingly, here, a programmable epidermal microfluidic valving system is devised, which is capable of biofluid sampling, routing, and compartmentalization for biomarker analysis. At its core, the system is a network of individually-addressable microheater-controlled thermo-responsive hydrogel valves, augmented with a pressure regulation mechanism to accommodate pressure built-up, when interfacing sweat glands. The active biofluid control achieved by this system is harnessed to create unprecedented wearable bioanalytical capabilities at both the sensor level (decoupling the confounding influence of flow rate variability on sensor response) and the system level (facilitating context-based sensor selection/protection). Through integration with a wireless flexible printed circuit board and seamless bilateral communication with consumer electronics (e.g., smartwatch), contextually-relevant (scheduled/on-demand) on-body biomarker data acquisition/display was achieved.
- 27 July 2020
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 117 (32) , 19017-19025
Noninvasive wearable electroactive pharmaceutical monitoring for personalized therapeutics
To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. In that regard, wearable biosensing technologies, capable of tracking drug pharmacokinetics in noninvasively retrievable biofluids (e.g., sweat), play a critical role, because they can be deployed at a large scale to monitor the individuals’ drug transcourse profiles (semi)continuously and longitudinally. To this end, voltammetry-based sensing modalities are suitable, as in principle they can detect and quantify electroactive drugs on the basis of the target’s redox signature. However, the target’s redox signature in complex biofluid matrices can be confounded by the immediate biofouling effects and distorted/buried by the interfering voltammetric responses of endogenous electroactive species. Here, we devise a wearable voltammetric sensor development strategy—centering on engineering the molecule–surface interactions—to simultaneously mitigate biofouling and create an “undistorted potential window” within which the target drug’s voltammetric response is dominant and interference is eliminated. To inform its clinical utility, our strategy was adopted to track the temporal profile of circulating acetaminophen (a widely used analgesic and antipyretic) in saliva and sweat, using a surface-modified boron-doped diamond sensing interface (cross-validated with laboratory-based assays, R2 ∼ 0.94). Through integration of the engineered sensing interface within a custom-developed smartwatch, and augmentation with a dedicated analytical framework (for redox peak extraction), we realized a wearable solution to seamlessly render drug readouts with minute-level temporal resolution. Leveraging this solution, we demonstrated the pharmacokinetic correlation and significance of sweat readings. Significance To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. By devising a surface engineering strategy, we created a voltammetric sensing interface, featuring an “undistorted potential window,” within which the target electroactive drug’s voltammetric response is dominant and interference is eliminated, rendering reliable target quantification in noninvasively retrievable biofluids (sweat and saliva). Leveraging this sensing interface, a fully integrated, wearable solution was constructed to seamlessly render drug readouts with minute-level temporal resolution. To inform its clinical utility, the solution was utilized to demonstrate noninvasive pharmacokinetic monitoring of a pharmaceutical (here, acetaminophen, a widely used analgesic and antipyretic) in a wearable format.
- 27 July 2020
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 117 (32) , 19017-19025
Noninvasive wearable electroactive pharmaceutical monitoring for personalized therapeutics
To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. In that regard, wearable biosensing technologies, capable of tracking drug pharmacokinetics in noninvasively retrievable biofluids (e.g., sweat), play a critical role, because they can be deployed at a large scale to monitor the individuals’ drug transcourse profiles (semi)continuously and longitudinally. To this end, voltammetry-based sensing modalities are suitable, as in principle they can detect and quantify electroactive drugs on the basis of the target’s redox signature. However, the target’s redox signature in complex biofluid matrices can be confounded by the immediate biofouling effects and distorted/buried by the interfering voltammetric responses of endogenous electroactive species. Here, we devise a wearable voltammetric sensor development strategy—centering on engineering the molecule–surface interactions—to simultaneously mitigate biofouling and create an “undistorted potential window” within which the target drug’s voltammetric response is dominant and interference is eliminated. To inform its clinical utility, our strategy was adopted to track the temporal profile of circulating acetaminophen (a widely used analgesic and antipyretic) in saliva and sweat, using a surface-modified boron-doped diamond sensing interface (cross-validated with laboratory-based assays, R2 ∼ 0.94). Through integration of the engineered sensing interface within a custom-developed smartwatch, and augmentation with a dedicated analytical framework (for redox peak extraction), we realized a wearable solution to seamlessly render drug readouts with minute-level temporal resolution. Leveraging this solution, we demonstrated the pharmacokinetic correlation and significance of sweat readings. Significance To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. By devising a surface engineering strategy, we created a voltammetric sensing interface, featuring an “undistorted potential window,” within which the target electroactive drug’s voltammetric response is dominant and interference is eliminated, rendering reliable target quantification in noninvasively retrievable biofluids (sweat and saliva). Leveraging this sensing interface, a fully integrated, wearable solution was constructed to seamlessly render drug readouts with minute-level temporal resolution. To inform its clinical utility, the solution was utilized to demonstrate noninvasive pharmacokinetic monitoring of a pharmaceutical (here, acetaminophen, a widely used analgesic and antipyretic) in a wearable format.
- 22 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1115-1117
A Stimuli-Responsive Hydrogel Array Fabrication Scheme for Large-Scale and Wearable Microfluidic Valving
Programmable microfluidic valving enables controlled routing and compartmentalized manipulation of fluid within networks of microfluidic channels--capabilities which can be harnessed to implement an automated, massively parallelized, and diverse set of bioanalytical operations in large-scale microfluidics (lab-on-a-chip) and wearable (lab-on-the-body) applications. Stimuli-responsive hydrogels are suitable base materials to construct programmable microfluidic valving interfaces: once embedded in a microfluidic channel, their volumetric shrinkage/expansion (in response to stimulus) can be exploited to open/close microfluidic channels. However, to adapt them for the envisioned applications, critical fabrication challenges including robustness (e.g., complete channel sealing), scalability (forming arrays of valves with high yield and throughput), miniaturization of the valve actuation interface, and mechanical compatibility (flexibility for wearability) must be addressed. Here, we devise a simple and low-cost fabrication scheme to create arrays of stimuli-responsive hydrogels (e.g., thermo-responsive) and optional stimulus embodiments (e.g., microheaters) with compact footprints and within complex microfluidic networks. Within the framework of this fabrication scheme, we specifically: 1) introduced an ex situ hydrogel hydro-conditioning step to achieve full channel sealing; 2) optimized the valve performance to achieve maximal volumetric response; and 3) utilized mechanically flexible and thin device layers to ensure compatibility for wearable applications. We illustrated the scalability of the fabricated valves and their enabling microfluid management capabilities, by demonstrating fluid routing/compartmentalization within valve-gated square matrix and radial tree matrix microfluidic networks. [2020-0211]
- 22 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1115-1117
A Stimuli-Responsive Hydrogel Array Fabrication Scheme for Large-Scale and Wearable Microfluidic Valving
Programmable microfluidic valving enables controlled routing and compartmentalized manipulation of fluid within networks of microfluidic channels--capabilities which can be harnessed to implement an automated, massively parallelized, and diverse set of bioanalytical operations in large-scale microfluidics (lab-on-a-chip) and wearable (lab-on-the-body) applications. Stimuli-responsive hydrogels are suitable base materials to construct programmable microfluidic valving interfaces: once embedded in a microfluidic channel, their volumetric shrinkage/expansion (in response to stimulus) can be exploited to open/close microfluidic channels. However, to adapt them for the envisioned applications, critical fabrication challenges including robustness (e.g., complete channel sealing), scalability (forming arrays of valves with high yield and throughput), miniaturization of the valve actuation interface, and mechanical compatibility (flexibility for wearability) must be addressed. Here, we devise a simple and low-cost fabrication scheme to create arrays of stimuli-responsive hydrogels (e.g., thermo-responsive) and optional stimulus embodiments (e.g., microheaters) with compact footprints and within complex microfluidic networks. Within the framework of this fabrication scheme, we specifically: 1) introduced an ex situ hydrogel hydro-conditioning step to achieve full channel sealing; 2) optimized the valve performance to achieve maximal volumetric response; and 3) utilized mechanically flexible and thin device layers to ensure compatibility for wearable applications. We illustrated the scalability of the fabricated valves and their enabling microfluid management capabilities, by demonstrating fluid routing/compartmentalization within valve-gated square matrix and radial tree matrix microfluidic networks. [2020-0211]
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1059-1063
A Fouling-Resistant Voltammetric Sensing System for Wearable Electroactive Biomarker Monitoring
Voltammetry-based sensing systems are suitable for wearable monitoring of electroactive biomarkers in epidermally-retrievable biofluids (e.g., sweat), as they can directly transduce the redox features of the targets into electrical signals, delivering a sample-to-answer solution. To render reliable voltammetric readouts, the fundamental challenge of biofluid-induced fouling (causing rapid and irreversible signal degradation) must be addressed-an issue which has been overlooked in the previously reported wearable sensor development methods, but widely reported in conventional voltammetric platforms. To this end, here, we devise a fouling-resistant voltammetric sensing interface that exploits an inert electrode surface (specifically, boron-doped diamond, facilitating weak adsorption of polar molecules) as well as a hydrophilic membrane coating (chitosan) to mitigate the interaction of fouling agents with the surface. Utilizing this engineered sensing interface, sub-micromolar level quantification of uric acid was demonstrated, where the sensor presented minimal interference from non-target electroactive species (within their physiologically relevant concentration range). By interfacing the developed sensor with a wireless circuit board-augmented with a dedicated analytical framework-seamless uric acid readout acquisition in sweat was achieved. The presented biofouling characterization/mitigation methodology provides a basis for wearable electroactive sensing system development.
- 17 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (5) , 1059-1063
A Fouling-Resistant Voltammetric Sensing System for Wearable Electroactive Biomarker Monitoring
Voltammetry-based sensing systems are suitable for wearable monitoring of electroactive biomarkers in epidermally-retrievable biofluids (e.g., sweat), as they can directly transduce the redox features of the targets into electrical signals, delivering a sample-to-answer solution. To render reliable voltammetric readouts, the fundamental challenge of biofluid-induced fouling (causing rapid and irreversible signal degradation) must be addressed-an issue which has been overlooked in the previously reported wearable sensor development methods, but widely reported in conventional voltammetric platforms. To this end, here, we devise a fouling-resistant voltammetric sensing interface that exploits an inert electrode surface (specifically, boron-doped diamond, facilitating weak adsorption of polar molecules) as well as a hydrophilic membrane coating (chitosan) to mitigate the interaction of fouling agents with the surface. Utilizing this engineered sensing interface, sub-micromolar level quantification of uric acid was demonstrated, where the sensor presented minimal interference from non-target electroactive species (within their physiologically relevant concentration range). By interfacing the developed sensor with a wireless circuit board-augmented with a dedicated analytical framework-seamless uric acid readout acquisition in sweat was achieved. The presented biofouling characterization/mitigation methodology provides a basis for wearable electroactive sensing system development.
- 26 February 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 5 (39)
A ferrobotic system for automated microfluidic logistics
A ferrobotic system is devised to implement diverse, efficient, and automated microfluidic logistics.
- 26 February 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 5 (39)
A ferrobotic system for automated microfluidic logistics
A ferrobotic system is devised to implement diverse, efficient, and automated microfluidic logistics.