Audrey Shih
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Audrey Shih has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Gerald. G. Fuller
Department of Chemical Engineering, Stanford University 1 , Stanford, California 94305
3 shared publications - Sarah C. Heilshorn
Department of Materials Science and Engineering Stanford University Stanford California USA
2 shared publications - Sujit Sankar Datta
Department of Chemical and Biological Engineering, Princeton University, Princeton, NJ 08544, USA
2 shared publications - Alexander M. Vezeridis
Department of Radiology, Division of Interventional Radiology, Stanford University School of Medicine, Stanford, CA 94305
1 shared publication - Andrew J. Spakowitz
Stanford University
1 shared publication - Brian Jun Lee
School of Mechanical Engineering, Sungkyunkwan University, Suwon, Republic of Korea
1 shared publication
Latest Publications
- 17 June 2026
- Published by IOP Publishing in Biofabrication
- Vol. 18 (3)
In situ rheological monitoring of diffusion-controlled hydrogel crosslinking for embedded 3D bioprinting
In embedded 3D bioprinting, biomaterial inks are extruded into sacrificial support baths to facilitate the fabrication of complex shapes, even from soft, liquid-like materials. Post-printing, the diffusion of small molecules into or out of the support bath can facilitate ink crosslinking to stabilize the printed structure. In these coupled reaction-diffusion systems, the rheological properties of the ink will change over time. Despite the importance of tuning the mechanical properties of these inks for biological applications, there are currently no methods to accurately predict ink stiffness over time throughout the crosslinking process. Here, we use a custom-developed magnetic stress rheometer to continuously monitor diffusion-driven crosslinking in situ. Our approach reveals how gelation kinetics depend on the thickness of the ink layer, and enables predictive estimation of mechanical evolution in these reaction-and diffusion-driven systems. With these insights, we fabricate specimens with predetermined mechanical properties and observe changes in cell phenotype as a response. These insights help inform the design of inks and timing of bioprinting protocols to achieve prints with desirable mechanical properties and further allow the fabrication of prints with patterned mechanical properties.
- 17 June 2026
- Published by IOP Publishing in Biofabrication
- Vol. 18 (3)
In situ rheological monitoring of diffusion-controlled hydrogel crosslinking for embedded 3D bioprinting
In embedded 3D bioprinting, biomaterial inks are extruded into sacrificial support baths to facilitate the fabrication of complex shapes, even from soft, liquid-like materials. Post-printing, the diffusion of small molecules into or out of the support bath can facilitate ink crosslinking to stabilize the printed structure. In these coupled reaction-diffusion systems, the rheological properties of the ink will change over time. Despite the importance of tuning the mechanical properties of these inks for biological applications, there are currently no methods to accurately predict ink stiffness over time throughout the crosslinking process. Here, we use a custom-developed magnetic stress rheometer to continuously monitor diffusion-driven crosslinking in situ. Our approach reveals how gelation kinetics depend on the thickness of the ink layer, and enables predictive estimation of mechanical evolution in these reaction-and diffusion-driven systems. With these insights, we fabricate specimens with predetermined mechanical properties and observe changes in cell phenotype as a response. These insights help inform the design of inks and timing of bioprinting protocols to achieve prints with desirable mechanical properties and further allow the fabrication of prints with patterned mechanical properties.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Viscoelastic measurements of abscess fluids using a magnetic stress rheometer
Abscesses, pockets of fluid caused by infections in the human body, are typically treated in hospitals by draining the fluid through a catheter. However, the viscous and heterogeneous nature of the fluid often leads to prolonged treatment duration or even drainage failure. Furthermore, current practice relies only on qualitative observations of viscosity for catheter size selection, with little quantitative data to guide this parameter. In this work, we introduce a compact magnetic stress rheometer platform to examine the rheological response of nine different abscess fluids under shear stress. A magnetic field applies a force to a probe that induces it to shear the underlying abscess fluid. Its spatiotemporal displacement is measured, resulting in the determination of creep compliance. The results are well-fitted to a 5-element viscoelastic model, providing a quantitative and robust prediction of abscess fluid rheology for a variety of etiologies. We show that while viscoelastic parameters between abscess fluids of different etiologies can span five orders of magnitude, zero-shear viscosity should be sufficient in future predictions of drainage flow rates. The custom-built instrument we have developed is portable, inexpensive, and sterile-compatible, serving as an ideal platform for point-of-care analyses in clinical settings to facilitate catheter selection and enable healthcare workers to devise optimal treatment strategies for each patient. Moreover, the versatility of our platform extends its potential application to rheological measurements in diverse medical contexts.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Viscoelastic measurements of abscess fluids using a magnetic stress rheometer
Abscesses, pockets of fluid caused by infections in the human body, are typically treated in hospitals by draining the fluid through a catheter. However, the viscous and heterogeneous nature of the fluid often leads to prolonged treatment duration or even drainage failure. Furthermore, current practice relies only on qualitative observations of viscosity for catheter size selection, with little quantitative data to guide this parameter. In this work, we introduce a compact magnetic stress rheometer platform to examine the rheological response of nine different abscess fluids under shear stress. A magnetic field applies a force to a probe that induces it to shear the underlying abscess fluid. Its spatiotemporal displacement is measured, resulting in the determination of creep compliance. The results are well-fitted to a 5-element viscoelastic model, providing a quantitative and robust prediction of abscess fluid rheology for a variety of etiologies. We show that while viscoelastic parameters between abscess fluids of different etiologies can span five orders of magnitude, zero-shear viscosity should be sufficient in future predictions of drainage flow rates. The custom-built instrument we have developed is portable, inexpensive, and sterile-compatible, serving as an ideal platform for point-of-care analyses in clinical settings to facilitate catheter selection and enable healthcare workers to devise optimal treatment strategies for each patient. Moreover, the versatility of our platform extends its potential application to rheological measurements in diverse medical contexts.
- Open Access
- 7 May 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026112
Air–liquid intestinal cell culture allows in situ rheological characterization of intestinal mucus
Intestinal health heavily depends on establishing a mucus layer within the gut with physical properties that strike a balance between being sufficiently elastic to keep out harmful pathogens yet viscous enough to flow and turnover the contents being digested. Studies investigating dysfunction of the mucus layer in the intestines are largely confined to animal models, which require invasive procedures to collect the mucus fluid. In this work, we develop a nondestructive method to study intestinal mucus. We use an air–liquid interface culture of primary human intestinal epithelial cells that exposes their apical surface to allow in situ analysis of the mucus layer. Mucus collection is not only invasive but also disrupts the mucus microstructure, which plays a crucial role in the interaction between mucus and the gut microbiome. Therefore, we leverage a noninvasive rheology technique that probes the mechanical properties of the mucus without removal from the culture. Finally, to demonstrate biomedical uses for this cell culture system, we characterize the biochemical and biophysical properties of intestinal mucus due to addition of the cytokine IL-13 to recapitulate the gut environment of Nippostrongylus brasiliensis infection.
- 7 May 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026112
Open AccessAir–liquid intestinal cell culture allows in situ rheological characterization of intestinal mucus
Intestinal health heavily depends on establishing a mucus layer within the gut with physical properties that strike a balance between being sufficiently elastic to keep out harmful pathogens yet viscous enough to flow and turnover the contents being digested. Studies investigating dysfunction of the mucus layer in the intestines are largely confined to animal models, which require invasive procedures to collect the mucus fluid. In this work, we develop a nondestructive method to study intestinal mucus. We use an air–liquid interface culture of primary human intestinal epithelial cells that exposes their apical surface to allow in situ analysis of the mucus layer. Mucus collection is not only invasive but also disrupts the mucus microstructure, which plays a crucial role in the interaction between mucus and the gut microbiome. Therefore, we leverage a noninvasive rheology technique that probes the mechanical properties of the mucus without removal from the culture. Finally, to demonstrate biomedical uses for this cell culture system, we characterize the biochemical and biophysical properties of intestinal mucus due to addition of the cytokine IL-13 to recapitulate the gut environment of Nippostrongylus brasiliensis infection.
- Top Cited PapersOpen Access
- 16 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (46) , eabq2846
Single-digit-micrometer-resolution continuous liquid interface production
To date, a compromise between resolution and print speed has rendered most high-resolution additive manufacturing technologies unscalable with limited applications. By combining a reduction lens optics system for single-digit-micrometer resolution, an in-line camera system for contrast-based sharpness optimization, and continuous liquid interface production (CLIP) technology for high scalability, we introduce a single-digit-micrometer-resolution CLIP-based 3D printer that can create millimeter-scale 3D prints with single-digit-micrometer-resolution features in just a few minutes. A simulation model is developed in parallel to probe the fundamental governing principles in optics, chemical kinetics, and mass transport in the 3D printing process. A print strategy with tunable parameters informed by the simulation model is adopted to achieve both the optimal resolution and the maximum print speed. Together, the high-resolution 3D CLIP printer has opened the door to various applications including, but not limited to, biomedical, MEMS, and microelectronics.
- 16 November 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (46) , eabq2846
Top Cited PapersOpen AccessSingle-digit-micrometer-resolution continuous liquid interface production
To date, a compromise between resolution and print speed has rendered most high-resolution additive manufacturing technologies unscalable with limited applications. By combining a reduction lens optics system for single-digit-micrometer resolution, an in-line camera system for contrast-based sharpness optimization, and continuous liquid interface production (CLIP) technology for high scalability, we introduce a single-digit-micrometer-resolution CLIP-based 3D printer that can create millimeter-scale 3D prints with single-digit-micrometer-resolution features in just a few minutes. A simulation model is developed in parallel to probe the fundamental governing principles in optics, chemical kinetics, and mass transport in the 3D printing process. A print strategy with tunable parameters informed by the simulation model is adopted to achieve both the optimal resolution and the maximum print speed. Together, the high-resolution 3D CLIP printer has opened the door to various applications including, but not limited to, biomedical, MEMS, and microelectronics.
- 2 March 2020
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 890
Bistability in the unstable flow of polymer solutions through pore constriction arrays
Polymer solutions are often injected in porous media for applications such as oil recovery and groundwater remediation. As the fluid navigates the tortuous pore space, elastic stresses build up, causing the flow to become unstable at sufficiently large injection rates. However, it is poorly understood how the spatial and temporal characteristics of this unstable flow depend on pore space geometry, which can vary widely between different porous media. We investigate this dependence by systematically varying the spacing between pore constrictions in a one-dimensional ordered array. We find that when the pore spacing is large, unstable eddies form upstream of each constriction, similar to observations of an isolated constriction. By contrast, when the pore spacing is sufficiently small, the flow in the different pores exhibits a surprising bistability, stochastically switching between two distinct unstable flow states. We hypothesize that this unusual behaviour arises from the interplay between elongation and relaxation of polymers as they are advected through the pore space. Consistent with this idea, we find that the flow state in a given pore persists for long times; moreover, flow states are strongly correlated between neighbouring pores. Thus, the characteristics of unstable flow are not determined just by injection conditions and the geometry of the individual pores, but also depend on the spacing between pores. Ultimately, these results help to elucidate the rich array of behaviours that can arise in polymer solution flow through porous media.
- 2 March 2020
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 890
Bistability in the unstable flow of polymer solutions through pore constriction arrays
Polymer solutions are often injected in porous media for applications such as oil recovery and groundwater remediation. As the fluid navigates the tortuous pore space, elastic stresses build up, causing the flow to become unstable at sufficiently large injection rates. However, it is poorly understood how the spatial and temporal characteristics of this unstable flow depend on pore space geometry, which can vary widely between different porous media. We investigate this dependence by systematically varying the spacing between pore constrictions in a one-dimensional ordered array. We find that when the pore spacing is large, unstable eddies form upstream of each constriction, similar to observations of an isolated constriction. By contrast, when the pore spacing is sufficiently small, the flow in the different pores exhibits a surprising bistability, stochastically switching between two distinct unstable flow states. We hypothesize that this unusual behaviour arises from the interplay between elongation and relaxation of polymers as they are advected through the pore space. Consistent with this idea, we find that the flow state in a given pore persists for long times; moreover, flow states are strongly correlated between neighbouring pores. Thus, the characteristics of unstable flow are not determined just by injection conditions and the geometry of the individual pores, but also depend on the spacing between pores. Ultimately, these results help to elucidate the rich array of behaviours that can arise in polymer solution flow through porous media.
Pore‐Scale Flow Characterization of Polymer Solutions in Microfluidic Porous Media
Polymer solutions are frequently used in enhanced oil recovery and groundwater remediation to improve the recovery of trapped nonaqueous fluids. However, applications are limited by an incomplete understanding of the flow in porous media. The tortuous pore structure imposes both shear and extension, which elongates polymers; moreover, the flow is often at large Weissenberg numbers, Wi, at which polymer elasticity in turn strongly alters the flow. This dynamic elongation can even produce flow instabilities with strong spatial and temporal fluctuations despite the low Reynolds number, Re. Unfortunately, macroscopic approaches are limited in their ability to characterize the pore‐scale flow. Thus, understanding how polymer conformations, flow dynamics, and pore geometry together determine these nontrivial flow patterns and impact macroscopic transport remains an outstanding challenge. This review describes how microfluidic tools can shed light on the physics underlying the flow of polymer solutions in porous media at high Wi and low Re. Specifically, microfluidic studies elucidate how steady and unsteady flow behavior depends on pore geometry and solution properties, and how polymer‐induced effects impact nonaqueous fluid recovery. This work thus provides new insights for polymer dynamics, non‐Newtonian fluid mechanics, and applications such as enhanced oil recovery and groundwater remediation.
Pore‐Scale Flow Characterization of Polymer Solutions in Microfluidic Porous Media
Polymer solutions are frequently used in enhanced oil recovery and groundwater remediation to improve the recovery of trapped nonaqueous fluids. However, applications are limited by an incomplete understanding of the flow in porous media. The tortuous pore structure imposes both shear and extension, which elongates polymers; moreover, the flow is often at large Weissenberg numbers, Wi, at which polymer elasticity in turn strongly alters the flow. This dynamic elongation can even produce flow instabilities with strong spatial and temporal fluctuations despite the low Reynolds number, Re. Unfortunately, macroscopic approaches are limited in their ability to characterize the pore‐scale flow. Thus, understanding how polymer conformations, flow dynamics, and pore geometry together determine these nontrivial flow patterns and impact macroscopic transport remains an outstanding challenge. This review describes how microfluidic tools can shed light on the physics underlying the flow of polymer solutions in porous media at high Wi and low Re. Specifically, microfluidic studies elucidate how steady and unsteady flow behavior depends on pore geometry and solution properties, and how polymer‐induced effects impact nonaqueous fluid recovery. This work thus provides new insights for polymer dynamics, non‐Newtonian fluid mechanics, and applications such as enhanced oil recovery and groundwater remediation.