BGBrizeida Gámez

Brizeida Gámez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Brizeida Gámez has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of a Four-Bar Mechanism for Knee Prosthesis Using a Genetic Algorithm Based on Freudenstein’s Equation

    by Fernando Valencia, Brizeida Gámez, David Ojeda

    Background: The natural motion of the human knee involves a combination of rotation and translation, resulting in a variable Instantaneous Center of Rotation (ICR) throughout the gait cycle. Traditional prosthetic knee designs often fail to reproduce this complex kinematic behavior. Objectives: This study aims to propose a customized, biomimetic knee mechanism through the synthesis of a four-bar linkage capable of approximating the physiological ICR trajectory with high precision. Methods: A Genetic Algorithm (GA) was implemented to optimize the geometric parameters of the four-bar mechanism, specifically its link lengths and inter-link angles. The optimization process is based on Freudenstein’s equation, which analytically relates the input and output angles of the linkage to the lengths of its links. The desired ICR trajectory was derived from experimental data, and the objective function minimized the Euclidean error between the generated and target trajectories. Results: The proposed method yielded customized mechanisms that closely approximate the target ICR curves, achieving an overall mean Euclidean tracking error of 1.95% (±1.68%) across diverse patient profiles, with a best-case optimization error as low as 0.355%. Furthermore, the GA demonstrated high computational efficiency, converging on optimal geometric configurations in an average execution time of just 3.98 min. Conclusions: These numerical results validate the robustness of the GA in navigating the design space while strictly adhering to kinematic constraints, Grashof’s condition, and anatomical motion limits. The integration of Freudenstein’s equation with GA-based optimization techniques enables the customized synthesis of four-bar linkages with a high capacity to reproduce the physiological kinematics of the knee. This computational approach could be highly beneficial for the design of polycentric knee prostheses, as it reduces design and manufacturing time by providing the initial parameters for the development of the four-bar mechanism, ultimately ensuring a better biomechanical fit between prosthetic and natural human movement.

  • Open Access

    Mechatronic Device for Accurate Characterization of Knee Flexion Based on Pivot Point

    by Fernando Valencia, Brizeida Gámez, David Ojeda, Hugo Salazar

    Objective: The purpose of this study is to develop a mechatronic device capable of characterizing the kinematics of the knee joint, based on the acquisition and analysis of data focused on the knee joint point. Methods: A mechatronic device was designed using dimensional data from a participant’s lower limb (1.59 m, 57 kg), obtained through 3D scanning. The device, based on a proportional mechanism aligned with anatomical reference points, allows the evolution of the knee joint pivot point (PPKJ) to be recorded. Ten healthy subjects (aged 22–26 years, height 1.50–1.63 m, body mass 48–59 kg) were selected for testing. The device was placed on each knee to record joint trajectories during squats. The trajectories were classified into two groups: extension to flexion and flexion to extension. For each group, the average trajectory was calculated. Results: Forty PPKJ trajectories were obtained, divided into two sets: extension to flexion with a range of 8° to 51.3° and flexion to extension with a range of 6.7° to 56.83°, which allowed the mean trajectory and cubic polynomial regression to be calculated as the best approximation for characterizing the trajectory of the instantaneous center of rotation of the knee joint. Conclusions: The developed mechatronic device offers an accessible and non-invasive solution for recording the trajectory of the knee joint pivot point in individuals with characteristics like those in the study. This alternative approach could improve the representation of knee kinematics in the design of customized prostheses, exoskeletons, and rehabilitation devices for lower limbs.


  • Open Access

    Personalized External Knee Prosthesis Design Using Instantaneous Center of Rotation for Improved Gait Emulation

    by Cristina Ayala, Fernando Valencia, Brizeida Gámez, Hugo Salazar, David Ojeda

    Background: The need to improve gait emulation in people with amputation has driven the development of customized prosthetic mechanisms. This study focuses on the design and validation of a mechanism for external knee joint prostheses, based on the trajectory of the Instantaneous Center of Rotation (ICR) of a healthy knee. Objective: The objective is to design a mechanism that accurately reproduces the evolution of the ICR trajectory, thereby improving stability and reducing the user’s muscular effort. Methods: An exploratory methodology was employed, utilizing computer-aided design (CAD), kinematic simulations, and rapid prototyping through 3D printing. Multiple configurations of four- and six-bar mechanisms were evaluated to determine the ICR trajectory and compare it with a reference model obtained in the laboratory from a specific subject, using MATLAB-2023a and the Fréchet distance as an error metric. Results: The results indicated that the four-bar mechanism, with the incorporation of a simple gear train, achieved a more accurate emulation of the ICR trajectory, reaching a minimum error of 6.87 mm. Functional tests confirmed the effectiveness of the design in terms of stability and voluntary control during gait. It can be concluded that integrating the mechanism with the gear train significantly enhances its functionality, making it a viable alternative for the development of external knee prostheses for people with transfemoral amputation, based on the ICR of the contralateral leg.


  • Open Access

    Non-Invasive Blood Density Measurement using Photoplethysmography Technique

    by Theo Marcelo Galindo Chicaiza, Luz María Tobar Subía Contento, Brizeida Nohemí Gámez Aparicio, Marco Antonio Ciaccia Sortino, Cosme Damián Mejía Echeverría, Diego Luis Ortiz Morales

    Introduction:Blood density measurement is a key diagnostic indicator for assessing hematological and cardiovascular conditions. Conventional methods require blood extraction and laboratory equipment. In this context, a non-invasive biomedical device based on photoplethysmography (PPG) and the Beer–Lambert law was developed to estimate blood density through optical parameters.Methods:A prototype was designed using a microcontroller, an optical sensor, and an OLED display. The acquired signals were digitally filtered through FIR and IIR algorithms to separate pulsatile and non-pulsatile components. Twenty-one volunteers were recruited, and sixteen valid recordings remained after artifact removal. Laboratory reference values were compared using linear regression and Bland–Altman analysis to evaluate concordance between clinical and device-derived measurements.Results:The device achieved an average error of 2.0 % for blood-density estimation, 6.06 % for hematocrit, and 7.01 % for erythrocyte count. The limits of agreement remained within clinically acceptable ranges, with a slight underestimation bias at higher density values. Main limitations were related to the restricted spectral range of the red and infrared LEDs and to physiological variables such as peripheral perfusion and involuntary movements.Conclusions:The proposed system demonstrated accuracy and stability for non-invasive blood-density estimation, validating PPG as a portable, low-cost diagnostic tool. Future improvements should include a broader calibration dataset and multispectral light sources with higher sensitivity to enhance linearity and dynamic range.

  • Open Access

    Personalized External Knee Prosthesis Design Using Instantaneous Center of Rotation for Improved Gait Emulation

    by Cristina Ayala, Fernando Valencia, Brizeida Gamez, Hugo Salazar, David Ojeda

    : The need to improve gait emulation in patients with transfemoral amputation has led to the development of customized prosthetic mechanisms. This study focuses on the design and validation of an external knee joint prosthesis mechanism, based on the trajectory of the Instantaneous Center of Rotation (ICR) of a healthy knee. The goal is to design a mechanism that closely follows the evolution of the ICR path, improving stability and reducing the user's muscle effort. An exploratory methodology was applied, using computer-aided design (CAD), kinematic simulations, and rapid prototyping with 3D printing. Several four-bar and six-bar mechanism configurations were evaluated by determining their ICR trajectories and comparing them to a reference model obtained in the lab from a specific patient, using MATLAB and Fréchet distance as the error metric. The results showed that the optimized four-bar mechanism, with the addition of gears, achieved the highest accuracy in matching the ICR trajectory, with a minimum error of 5 mm. Functional tests confirmed the effectiveness of the design in terms of stability and voluntary control during walking. It is concluded that optimizing the mechanism design based on the ICR significantly improves functionality and supports its clinical implementation and impact on users’ quality of life.


  • Open Access

    Effect of 3D printing parameters on the mechanical characteristics of carbon fiber- reinforced PLA

    by Arley Chuquin, Brizeida Gámez, Marco Naranjo, David Ojeda

    The comparative results of the mechanical behavior of carbon fiber-reinforced Polylactic Acid (PLA FC) specimens of two brands of filaments for printing by the Fused Deposition Modeling (FDM) process are presented. The experiments were carried out according to ASTM D638 14, using Type I specimens with the established dimensions. For the generation of the 3D model, parameters such as printing temperature, printing speed, density, and filling pattern were set. Cubic, gyroid, and triangular filling patterns were used, with filling densities of 40%, 60%, and 80%. For each configuration, a G-code was generated and used for the fabrication of each specimen. A total of 90 specimens were used, which were divided into two groups according to the brand. Subsequently, tensile tests were carried out to determine the mechanical properties by analyzing the stress-strain curves under the established conditions. Comparative analysis revealed that SUNLU's PLA FC filament achieves higher ultimate stress values, while Artillery's filament has a better ability to withstand deformation. Likewise, the filler pattern that withstood the greatest load was the cubic one.

  • A Non-invasive Portable Solution to Estimate Hemoglobin Levels in the Blood

    by Maythe Mieles Freire, Luz María Tobar Subía, Brizeida Nohemí Gamez Aparicio, Guillermo Mosquera Canchingre


  • Open Access

    Análisis estadístico de accidentes de tránsito en la ciudad de Ibarra durante el periodo 2017-2022

    by Carlos Santana, Anthony Maldonado, Fabio Cabascango, Bryan Guerrero, Gabriel Quelal, Brizeida Gamez

    Un hecho relevante dentro de la ciudad de Imbabura se debe a los accidentes de tránsito. En algunos hechos se reportan personas lesionadas y en casos extremos fallecidos. Es así que esta situación debe minimizarse tanto en los peatones, en conductores y en la comunidad en general. Dado lo anterior, resulta importante identificar las causas de los accidentes de tránsito en la ciudad, al realizar un análisis detallado de los factores que influyen para la ocurrencia de estos eventos. Para ello se expone el análisis de datos estadísticos obtenidos en el periodo 2017-2022 por parte de las entidades del estado, para los accidentes de tránsito considerando los datos principales efectuados al momento que suceden los accidentes. El método cualitativo fue escogido para obtener conclusiones de datos heterogéneos y no estructurados que no se detallan numéricamente. Con base a la información recogida se determinaron como elementos claves los factores humanos, específicamente el consumo de alcohol, exceso de velocidad e irrespeto de las normas de tránsito. Respecto a las zonas de la ciudad con mayor concurrencia se determinó que corresponden a los alrededores del Mercado Amazonas y El Estadio; mientras que la mayor incidencia de accidentes ocurre los fines de semana.

  • Open Access

    Pure laparoscopic living donor right hepatectomy (with video)

    by B Gamez, J Benitez, F Puelma, N Jarufe

    Only a few centers in the world perform pure laparoscopic right hepatectomy for adult-to-adult living donor liver transplantation. In this procedure, right lobe donation is mostly preferred in view of the higher graft volume usually needed for the recipient. In the area, laparoscopic surgery has had a minor development given the greater technical difficulty and risks for both donor and preservation of the graft. Nevertheless, last 3 years, the advances in major laparoscopic liver surgery suggest that pure laparoscopic right hepatectomy could be a feasible and safe procedure in appropriately selected donors, and mostly, when is performed by surgeons with significant experience in both laparoscopic liver surgery and liver transplantation with living donor liver grafts. This video shows the surgical technique of a pure laparoscopic right hepatectomy in a 30-year-old female volunteered for living donation to her brother.