RARana Altay

Rana Altay

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rana Altay has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Skin-like micropumps transform human motion into fluidic flow via morphing valves

    by Rana Altay, Kari Olson, Johanna Brown, Andrea Pader, I. Emre Araci

    Soft, skin-conformal fluidic systems are essential for wearable healthcare; however, micropumps that rely on rigid external hardware for actuation have limited portability and on-body integration. Here, we introduce OSMiPump, a power-free, strain-driven micropump that directly converts natural human motion into unidirectional fluid transport using a soft, monolithic architecture. OSMiPump integrates out-of-surface microchannels (OSMiCs) with self-actuated valves (OSMiValves), where cyclic tensile strain induces volume reduction and valve snap-through/snap-back, producing reliable directionality over repeated strain cycles. Computational fluid-structure interaction modeling and nonlinear shell deformation analysis validate the operating mechanism. Experimentally, OSMiPump exhibits predictable performance across valve geometries, strain levels and profiles, fluid viscosities, and inlet/outlet resistance configurations. At 20% strain, it achieves average flow rates up to ~0.16 µL/s under low-resistance conditions and maintains ~0.02 µL/s under high-resistance conditions, reaching peak pressures of ~11 kPa and sustaining an average pressure of ~0.6 kPa, with consistent operation over 100 cycles. The self-morphing architecture further enables tunable pumping behavior, including adjustable strain thresholds and response dynamics. Wearable demonstrations show direct actuation by body motion and enable both on-body delivery and removal for applications such as wound care and drug administration during physical rehabilitation, exercise, or daily activities. Integration into silicone socks and skin-mounted Tegaderm films illustrates the versatility of the platform. Together, these results establish OSMiPump as a soft, monolithic, and skin-conformal micropump for next-generation wearable biomedical systems. The alternative text for this image may have been generated using AI.


  • Morphing out-of-surface channels enable strain-based control over fluid flow in skin-mountable patches

    by Rana Altay, Hudson Gasvoda, Max Mailloux-Beauchemin, Johanna Brown, Kari Olson, I. Emre Araci

    The volume of natural materials increases under tension, thus conventionally biomechanical actuation of fluidic pumps relies on compression for pressure generation. Here, we report on out-of-surface microchannels (OSMiCs) that exhibit negative volumetric strain (i.e., pressure generation) under skin-induced tensile strain. Monolithic polydimethylsiloxane (PDMS) patches were fabricated and characterized. The complex relations between the wrinkling and buckling of the OSMiC shell and the fluid flow patterns were investigated. OSMiCs were shown to snap-back (-through) between two stable states that lead to (ir)reversible fluid flow depending on their architecture. Unlike standard microchannels that only generate pressure symmetrically upon application and release of tensile strain, OSMiCs are shown to be tunable for providing an asymmetrical pressure owing to their shape-change property (i.e., morphing). The maximum forward (backward) flow pressure of 10 (−14) kPa was measured upon 20% uniaxial strain application (release). The versatile fabrication technique allowed the integration of OSMiCs with different Q values, leading to a discrete strain-actuated flow control element. Numerical simulations were conducted and shown to support the experimentally observed wrinkling and buckling behavior. Finally, the operation of the power-free OSMiC skin patch for strain-based liquid administration on skin was demonstrated.


  • Open Access

    Human Activity Recording Based on Skin-Strain-Actuated Microfluidic Pumping in Asymmetrically Designed Micro-Channels

    by Caroline Barbar Askar, Nick Cmager, Rana Altay, I. Emre Araci

    The capability to record data in passive, image-based wearable sensors can simplify data readouts and eliminate the requirement for the integration of electronic components on the skin. Here, we developed a skin-strain-actuated microfluidic pump (SAMP) that utilizes asymmetric aspect ratio channels for the recording of human activity in the fluidic domain. An analytical model describing the SAMP’s operation mechanism as a wearable microfluidic device was established. Fabrication of the SAMP was achieved using soft lithography from polydimethylsiloxane (PDMS). Benchtop experimental results and theoretical predictions were shown to be in good agreement. The SAMP was mounted on human skin and experiments conducted on volunteer subjects demonstrated the SAMP’s capability to record human activity for hundreds of cycles in the fluidic domain through the observation of a stable liquid meniscus. Proof-of-concept experiments further revealed that the SAMP could quantify a single wrist activity repetition or distinguish between three different shoulder activities.


  • Open Access

    Late Breaking Results: Efficient Built-in Self-Test for Microfluidic Large-Scale Integration (mLSI)

    by Mengchu Li, Hanchen Gu, Yushen Zhang, Siyuan Liang, Hudson Gasvoda, Rana Altay, Ismail Emre Araci, Tsun-Ming Tseng, Tsung-Yi Ho, Ulf Schlichtmann

    Control channels on microfluidic large-scale integration (mLSI) chips are prone to blockage and leakage defects. In this work, we propose a built-in self-test (BIST) method that drastically improves the test efficiency. Given n to-be-tested control channels, we reduced the number of test patterns for blockage and leakage tests from [EQUATION] to 1, and from ⌈log2(n + 1)⌉ to ⌈log2(χ(G) + 1)⌉, respectively, where χ(G) denotes the vertex chromatic number of a graph G consisting of n vertices. We fabricated our design and demonstrated the feasibility and efficiency of our method.


  • Open Access

    LaMUX: Optimized Logic-Gate-Enabled High-Performance Microfluidic Multiplexer Design

    by Siyuan Liang, Yushen Zhang, Rana Altay, Hudson Gasvoda, Mengchu Li, Ismail Emre Araci, Tsun-Ming Tseng, Ulf Schlichtmann, Tsung-Yi Ho

    After decades of development, flow-based microfluidic biochips have become an increasingly attractive platform for biochemical experiments. The fluid transportation and the on-chip device operation are controlled by microvalves, which are driven by external pneumatic controllers. To meet the increasingly complex experimental demands, the number of microvalves has significantly increased, making it necessary to adopt multiplexers (MUXes) for the actuation of microvalves. However, existing MUX designs have limited coding capacities, resulting in area overhead and excessive chip-to-world interface. This paper proposes a novel gate structure for modifying the current MUX architecture, along with a mixed coding strategy that achieves the maximum coding capacity within the modified MUX architecture. Additionally, an efficient synthesis tool for the mixed-coding-based MUXes (LaMUXes) is presented. Experimental results demonstrate that the LaMUX is exceptionally efficient, substantially reducing the usage of pneumatic controllers and microvalves compared to existing MUX designs.


  • Open Access

    An Integrated Approach to Control the Penetration Depth of 3D-Printed Hollow Microneedles

    by Kendall Marie Defelippi, Allyson Yuuka Saumei Kwong, Julia Rose Appleget, Rana Altay, Maya Bree Matheny, Mary Margaret Dubus, Lily Marie Eribes, Maryam Mobed-Miremadi

    A variety of hollow microneedle (HMN) designs has emerged for minimally invasive therapies and monitoring systems. In this study, a design change limiting the indentation depth of the (3D) printed custom microneedle assembly (circular array of five conical frusta with and without a stopper, aspect ratio = 1.875) fabricated using stereolithography has been experimentally validated and modeled in silico. The micro-indentation profiles generated in confined compression on 1 mm ± 0.073 mm alginate films enabled the generation of a Prony series, where displacement ranged from 100 to 250 µm. These constants were used as intrinsic properties simulating experimental ramp/release profiles. Puncture occurred on two distinct hydrogel formulations at the design depth of 150 µm and indentation rate of 0.1 mm/s characterized by a peak force of 3.5 N (H = 31 kPa) and 8.3 N (H = 36.5 kPa), respectively. Experimental and theoretical alignments for peak force trends were obtained when the printing resolution was simulated. Higher puncture force and uniformity inferred by the stopper was confirmed via microscopy and profilometry. Meanwhile, poroviscoelasticity characterization is required to distinguish mass loss vs. redistribution post-indentation through pycnometry. Results from this paper highlight the feasibility of insertion-depth control within the epidermis thickness for the first time in solid HMN literature.


  • Open Access

    A Hybrid Spiral Microfluidic Platform Coupled with Surface Acoustic Waves for Circulating Tumor Cell Sorting and Separation: A Numerical Study

    by Rana Altay, Murat Kaya Yapici, Ali Koşar

    The separation of circulating tumor cells (CTCs) from blood samples is crucial for the early diagnosis of cancer. During recent years, hybrid microfluidics platforms, consisting of both passive and active components, have been an emerging means for the label-free enrichment of circulating tumor cells due to their advantages such as multi-target cell processing with high efficiency and high sensitivity. In this study, spiral microchannels with different dimensions were coupled with surface acoustic waves (SAWs). Numerical simulations were conducted at different Reynolds numbers to analyze the performance of hybrid devices in the sorting and separation of CTCs from red blood cells (RBCs) and white blood cells (WBCs). Overall, in the first stage, the two-loop spiral microchannel structure allowed for the utilization of inertial forces for passive separation. In the second stage, SAWs were introduced to the device. Thus, five nodal pressure lines corresponding to the lateral position of the five outlets were generated. According to their physical properties, the cells were trapped and lined up on the corresponding nodal lines. The results showed that three different cell types (CTCs, RBCs, and WBCs) were successfully focused and collected from the different outlets of the microchannels by implementing the proposed multi-stage hybrid system.


  • The effects of baffle configuration and number on inertial mixing in a curved serpentine micromixer: Experimental and numerical study

    by Vahid Ebrahimpour Ahmadi, Ismail Butun, Rana Altay, Sajad Razavi Bazaz, Hossein Alijani, Suleyman Celik, Majid Ebrahimi Warkiani, Ali Koşar


  • Open Access

    Numerical and Experimental Studies on the Effect of Surface Roughness and Ultrasonic Frequency on Bubble Dynamics in Acoustic Cavitation

    by Rana Altay, Abdolali K. Sadaghiani, M. Ilker Sevgen, Alper Şişman, Ali Koşar

    With many emerging applications such as chemical reactions and ultrasound therapy, acoustic cavitation plays a vital role in having improved energy efficiency. For example, acoustic cavitation results in substantial enhancement in the rates of various chemical reactions. In this regard, an applied acoustic field within a medium generates acoustic streaming, where cavitation bubbles appear due to preexisting dissolved gas in the working fluid. Upon cavitation inception, bubbles can undergo subsequent growth and collapse. During the last decade, the studies on the effects of different parameters on acoustic cavitation such as applied ultrasound frequency and power have been conducted. The bubble growth and collapse mechanisms and their distribution within the medium have been classified. Yet, more research is necessary to understand the complex mechanism of multi-bubble behavior under an applied acoustic field. Various parameters affecting acoustic cavitation such as surface roughness of the acoustic generator should be investigated in more detail in this regard. In this study, single bubble lifetime, bubble size and multi-bubble dynamics were investigated by changing the applied ultrasonic field. The effect of surface roughness on bubble dynamics was presented. In the analysis, images from a high-speed camera and fast video recording techniques were used. Numerical simulations were also done to investigate the effect of acoustic field frequency on bubble dynamics. Bubble cluster behavior and required minimum bubble size to be affected by the acoustic field were obtained. Numerical results suggested that bubbles with sizes of 50 µm or more could be aligned according to the radiation potential map, whereas bubbles with sizes smaller than 10 µm were not affected by the acoustic field. Furthermore, it was empirically proven that surface roughness has a significant effect on acoustic cavitation phenomena.