MCMarta Castany

Marta Castany

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marta Castany has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Out of Sight, Out of Chamber: PreserFlo® MicroShunt Dislocation Following Office-Based Needling

    by Rocío García-Risco, Tetiana Goncharova Simón, Marc Tort, Paula Garcia Valentin, Cristina Parés Alfonso, Paul Gerard Buck Espel, Laura Sánchez Vela, Marta Castany

    Out of Sight, Out of Chamber: PreserFlo® MicroShunt Dislocation Following Office-Based Needling - Turkish Journal of Ophthalmology

  • Open Access

    Real-Life Effectiveness and Safety of Selective Laser Trabeculoplasty as Primary, Adjunctive, and Substitutive Therapy

    by David Oliver-Gutierrez, Osvaldo Guevara-Chavarría, Shirin Djavanmardi, Gloria Segura-Duch, Marta Castany, Stefania Piludu, Carlos A. Arciniegas-Perasso, Elena Ávila, Elena Milla, Susana Duch

    Real-Life Effectiveness and Safety of Selective Laser Trabeculoplasty as Primary, Adjunctive, and Substitutive Therapy - Turkish Journal of Ophthalmology


  • Open Access

    Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up

    by Yann Bertolani, Jaume Rigo-Quera, Laura Sánchez-Vela, Olivia Pujol-Carreras, Manuel Amilburu, Antonio Dou, Marta Castany

    Background: To compare the efficacy and safety of the XEN® 63 µm and 45 µm devices with the ab externo open conjunctiva with a 30G needle approach. Methods: A retrospective, non-randomized and single-center study was conducted. Consecutive eyes undergoing a XEN® 63 µm implant were compared with a matched cohort of cases with a XEN® 45 µm implant. Standalone and combined procedures with phacoemulsification were included. Results: A total of 28 XEN® 45 µm and 28 XEN® 63 µm were included. Complete surgical success was achieved in 17 cases (60.7%) in the 45 µm group and in 20 cases (71.4%) in the 63 µm group, with no statistical differences. One year after the surgery, the mean IOP was 13.8 ± 3.3 mmHg for the 45 µm group and 12.4 ± 4.2 mmHg for the 63 µm group (p-value > 0.05). Likewise, the use of glaucoma medication was lowered in the 63 µm device (0.32 ± 0.87) compared to the 45 µm device (0.39 ± 0.86), with no statistical significance. Postoperative hypotony was more frequent in the 63 µm device (39.3%) than in the 45 µm group (28.6%), with no statistical differences. However, hypotony-associated complications (including choroidal detachment, hypotony keratopathy, and hypotony maculopathy) were significantly higher in the 63 µm group (p = 0.011). Conclusions: Although the XEN® 63 µm may offer a greater IOP-lowering effect with better complete surgical success, no significant differences were detected compared to the 45 µm device. Hypotony-related complications were higher in the XEN 63 µm, although most of them resolved with conservative management.


  • Open Access

    Efficacy and Safety of Ab Externo Open Conjunctiva XEN® 63 µm Implantation with a 30G Needle Scleral Tract in Primary Open-Angle Glaucoma

    by Yann Bertolani, Jaume Rigo-Quera, Laura Sánchez-Vela, Olivia Pujol-Carreras, Manuel Amilburu, Antonio Dou, Marta Castany

    Background: This study aimed to assess the efficacy and safety of the 30G needle mediated ab externo open conjunctiva approach for the XEN 63 µm implant in primary open-angle glaucoma. Methods: A retrospective and non-randomized study was conducted on consecutive cases of medically refractory primary open-angle glaucoma treated with standalone ab externo open conjunctiva XEN® 63 µm (North Chicago, Illinois) with one-year follow-up. Results: Twenty-two eyes were included. The mean preoperative intraocular pressure was 21.9 ± 7.2 mmHg, and the mean number of glaucoma medications was 2.4 ± 0.9. All patients underwent mitomycin 0.02% application for 2 min, and Healaflow® (MedicalMix, Spain), was implanted in 11 cases (50%). Complete surgical success was achieved in 14 cases (63.6%). No statistical differences in complete surgical success were noted based on the use of Healaflow®. A significant reduction in intraocular pressure (11.8 ± 3.4 mmHg) and in the number of hypotensive medications (0.2 ± 0.5 mmHg) was observed 1 year after the procedure. Transient hypotony was detected in 31.8% of cases. Complications secondary to hypotony included four cases of serous choroidal detachment and one case of localized hemorrhagic choroidal detachment, the latter associated with hypotonic keratopathy and hypotonic maculopathy. All these complications evolved favorably with conservative management and adjusted topical treatment. Conclusions: This study highlights the efficacy and safety of this approach for the XEN 63 µm implant in medically refractory primary open-angle glaucoma.


  • Ophthalmic manifestations in atypical hemolytic uremic syndrome triggered by intravitreal anti-VEGF

    by X. Garrell-Salat, A. Boixadera, L. Distefano, N. Ramos-Terrades, J. García-Arumí, M. Castany-Aregall

  • Open Access

    Filtering Bleb Characteristics in Combined Cataract Surgery with Ex-PRESS Implant vs. Non-Penetrating Deep Sclerectomy. A Prospective, Randomized, Multi-Center Study

    by Alfonso Anton, Marcos Muñoz, Marta Castany, Alfonso Gil, Alberto Martinez, Francisco Muñoz-Negrete, Jose Urcelay, Javier Moreno-Montañes

    (1) Background: After filtering surgery, bleb morphology is an indicator of the factors that may determine the final intraocular pressure (IOP). The present study aimed to evaluate and compare filtering bleb characteristics after combined cataract and glaucoma surgery. (2) Methods: We conducted a prospective multi-center randomized trial. Eyes with glaucoma and cataract were randomly assigned to either phacoemulsification and filtration surgery with an EX-PRESS implant (Alcon) or non-penetrating deep sclerectomy (NPDS) with an ESNOPER implant (AJL). The bleb characteristics were assessed with the Moorfields bleb grading system at months 1 and 12 of follow-up, and the relationship with IOP was analyzed. (3) Results: There were significant changes in bleb appearance between the assessments at month 1 and month 12. The changes in bleb appearance were more evident in the EX-PRESS group. The central area in the EX-PRESS group decreased from 2.9 at month 1 to 2.4 at month 12 (p = 0.014). Bleb height in the EX-PRESS group decreased from 2.3 at month 1 to 1.8 at month 12 (p = 0.034). The vascularity of the central area in the NPDS group decreased from 1.8 at month 1 to 1.3 at month 12 (p = 0.02). The maximal bleb area was inversely related (r = −0.39; p = 0.03) to the IOP in the NPDS group at month 1. Vascularity in the central area was directly related (r = 0.39; p = 0.01) to a higher IOP in the EX-PRESS group at month 1. Vascularity in the central area (r = 0.56; p < 0.001) and maximal area (r = 0.37; p = 0.012) at month 1 was directly related to a higher IOP in the EX-PRESS group at month 12. (4) Conclusions: More intense vascularity at month 1 was related to a higher final IOP in the EX-PRESS group. Larger blebs were associated with a lower IOP in the NPDS group.


  • Iridocorneal endothelial syndrome: Descemet's membrane-endothelium complex assessed by high-resolution anterior segment optical coherence tomography

    by M. Bergés, E. Kirkegaard, B. Azarfane, J. Oliveres, A. Andrade, L. Sánchez-Vela, M. Castany, L. Bisbe

  • Angioid streaks and obstructive sleep apnea syndrome: are they related?

    by Marta Castany-Aregall, Gloria Aparicio, Núria Grau, Amadeu Carceller, Santiago Pérez-Hoyos, Jaume Català-Mora, Alfonso Anton

    Background Sleep apnea syndrome (OSAS) has been associated with different ocular manifestations including glaucoma, floppy eye syndrome, punctate keratitis, keratoconus, and optic neuropathy. Angioid streaks are mainly associated with pseudoxanthoma elasticum (PXE) although they can appear in other systemic conditions affecting the elastic fibers. Methods This is a prospective, cross-sectional study. A complete ophthalmic examination was performed in 92 patients undergoing overnight polysomnography for suspicion of OSAS. Diagnosis and classification of OSAS were made based on apnea-hypopnea index (AHI). Stereoscopic optic disc photographs were taken in all patients and independently evaluated by two ophthalmologists. Patients with angioid streaks were referred to a dermatologist for axillary skin biopsy in order to rule out pseudoxanthoma elasticum or other skin abnormalities. Results Bilateral angioid streaks were observed in three patients who had been diagnosed with severe OSAS (AHI > 30/h). No clinical features characteristic of pseudoxanthoma elasticum or other pathological skin signs were observed. Skin biopsies were normal for all three patients, supporting the diagnosis of idiopathic angioid streaks. One of the patients developed bilateral choroidal neovascularization secondary to the angioid streaks over subsequent years. Conclusions In view of the low prevalence of idiopathic angioid streaks in the general population, the finding of angioid streaks in patients with severe OSAS suggests OSAS as a possible risk factor for its development. The hypothesis of a connective tissue abnormality that could explain an association between both entities deserves further elucidation.


  • Open Access

    Pruebas no habituales con utilidad clínica en el glaucoma

    by Marta Castany Aregall, Jaume Rigo Quera, Olivia Pujol Carreras, Antoni Dou Sáenz de Vizmanos