Cuimin Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cuimin Feng has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Jing Li
Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing, China
5 shared publicationsWeiqi Yang
Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing, China
4 shared publicationsYing Li
Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
4 shared publicationsZhen Xu
Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
4 shared publicationsZiyu Guo
Beijing General Municipal Engineering Design & Research Institute Co. Ltd, Building 3, No.32, North Xizhimen Street, Haidian District, Beijing, 100082, China
4 shared publicationsNa Zhu
Key Laboratory of Urban Stormwater System and Water Environment, Ministry of Education, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
3 shared publications
Latest Publications
- 16 September 2026
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
Inhibition Mechanism of a Tea Polyphenols and Zinc Acetate Composite Corrosion Inhibitor for Carbon Steel
Traditional phosphorus-based corrosion inhibitors pose severe environmental risks. To provide a sustainable alternative, an eco-friendly composite inhibitor (TP-AC) combining tea polyphenols (TP) and zinc acetate (AC) was developed to protect carbon steel. Its performance and mechanisms were evaluated via weight loss tests, electrochemical measurements, SEM, and XPS. Results show TP-AC is a highly efficient mixed-type inhibitor, offering superior, longer-lasting protection than AC alone. Its spontaneous, exothermic chemisorption onto the steel surface follows the Langmuir isotherm. Mechanistically, TP and AC exhibit strong synergy: AC-derived Zn(II)–O-containing species, likely including ZnO, contribute to the inorganic component of the protective film, while the phenolic hydroxyl groups of TP interact with surface Fe species to suppress anodic dissolution. Together, these organic and inorganic species form a dense, stable hybrid passivation film, effectively isolating the metal from the corrosive medium. This work provides a theoretical basis for green, high-performance metal protection in industrial circulating cooling water systems.
- 16 September 2026
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
Inhibition Mechanism of a Tea Polyphenols and Zinc Acetate Composite Corrosion Inhibitor for Carbon Steel
Traditional phosphorus-based corrosion inhibitors pose severe environmental risks. To provide a sustainable alternative, an eco-friendly composite inhibitor (TP-AC) combining tea polyphenols (TP) and zinc acetate (AC) was developed to protect carbon steel. Its performance and mechanisms were evaluated via weight loss tests, electrochemical measurements, SEM, and XPS. Results show TP-AC is a highly efficient mixed-type inhibitor, offering superior, longer-lasting protection than AC alone. Its spontaneous, exothermic chemisorption onto the steel surface follows the Langmuir isotherm. Mechanistically, TP and AC exhibit strong synergy: AC-derived Zn(II)–O-containing species, likely including ZnO, contribute to the inorganic component of the protective film, while the phenolic hydroxyl groups of TP interact with surface Fe species to suppress anodic dissolution. Together, these organic and inorganic species form a dense, stable hybrid passivation film, effectively isolating the metal from the corrosive medium. This work provides a theoretical basis for green, high-performance metal protection in industrial circulating cooling water systems.
- 15 August 2026
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (20) , 1153
Mechanisms of Natural Organic Matter Influencing on Coagulation Process for Nanoplastics Removal from Water
- 15 August 2026
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (20) , 1153
Mechanisms of Natural Organic Matter Influencing on Coagulation Process for Nanoplastics Removal from Water
- Open Access
- 8 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (10) , 4704
Carbon Footprint Assessment for Pumps Within the Lifecycle
Pumps, as critical equipment in water supply and drainage systems, contribute significantly to energy use and carbon emissions throughout their life cycle. This study quantified the life-cycle carbon footprint (LCF) of water supply and drainage pumps by developing a life-cycle assessment (LCA)-based model covering raw material acquisition, production and processing, transportation, operation, and recycling. Using the 400S-40 single-stage double-suction centrifugal pump as a case, the results showed that: (1) the total LCF of the pump was 5567.56 t CO2e per unit; and (2) the operational stage accounted for 99.69% of the total life-cycle emissions. The findings indicate that, for the studied case, use-phase electricity consumption dominates the overall carbon footprint under the stated assumptions. Accordingly, for water utilities and pump users, improving operating efficiency and reducing avoidable electricity consumption are critical to carbon reduction. For pump manufacturers, enhancing processing technology, adopting low-carbon materials, improving durability, and promoting component-level maintenance and replacement can reduce embodied carbon and avoid unnecessary emissions associated with premature full-unit replacement. Beyond carbon reduction, these measures are also conducive to resource conservation, sustainable manufacturing, and the low-carbon transition of urban water infrastructure. Therefore, this study provides methodological support for the green design, operation, and management of pump equipment, and contributes to the sustainable development of water supply and drainage systems.
- 8 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (10) , 4704
Open AccessCarbon Footprint Assessment for Pumps Within the Lifecycle
Pumps, as critical equipment in water supply and drainage systems, contribute significantly to energy use and carbon emissions throughout their life cycle. This study quantified the life-cycle carbon footprint (LCF) of water supply and drainage pumps by developing a life-cycle assessment (LCA)-based model covering raw material acquisition, production and processing, transportation, operation, and recycling. Using the 400S-40 single-stage double-suction centrifugal pump as a case, the results showed that: (1) the total LCF of the pump was 5567.56 t CO2e per unit; and (2) the operational stage accounted for 99.69% of the total life-cycle emissions. The findings indicate that, for the studied case, use-phase electricity consumption dominates the overall carbon footprint under the stated assumptions. Accordingly, for water utilities and pump users, improving operating efficiency and reducing avoidable electricity consumption are critical to carbon reduction. For pump manufacturers, enhancing processing technology, adopting low-carbon materials, improving durability, and promoting component-level maintenance and replacement can reduce embodied carbon and avoid unnecessary emissions associated with premature full-unit replacement. Beyond carbon reduction, these measures are also conducive to resource conservation, sustainable manufacturing, and the low-carbon transition of urban water infrastructure. Therefore, this study provides methodological support for the green design, operation, and management of pump equipment, and contributes to the sustainable development of water supply and drainage systems.
- Open Access
- 5 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (9) , 4555
Life Cycle Carbon Emission Analysis of a Sludge Dewatering Facility: A South-to-North Water Diversion Case Study
To mitigate the impact of global climate change, countries worldwide must take necessary measures to address this environmental issue. China’s goals of carbon peaking and carbon neutrality and the “1 + N” policy framework have provided guidance for various industries and enterprises in advancing carbon accounting, carbon reduction, and green transformation. This study focuses on the sludge dewatering facility of a typical water treatment plant, which uses water from the South-to-North Water Diversion Project as its water source. Based on its construction and operational data, the carbon emissions at different phases were calculated with the emission factor method in the study, and the composition of these emissions was analyzed. The results show that during the three-year construction period, the sludge dewatering facility emitted a total of 1385.57 tons of CO2-eq, with materials being the main source of carbon emissions. While in the one-year operation period, the facility generated 19.38 tons of CO2-eq only, with electricity consumption being the primary contributor, followed by chemicals consumption. In conclusion, both the short-term intensive emissions during the construction phase and the long-term cumulative emissions during the operation phase should be considered, so that an integrated mitigation effect can be achieved across the construction and operation stages. This highlights the necessity of adopting a life-cycle perspective in carbon reduction strategies within the defined system boundary, while also supporting the sustainable planning and management of water treatment infrastructure.
- 5 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (9) , 4555
Open AccessLife Cycle Carbon Emission Analysis of a Sludge Dewatering Facility: A South-to-North Water Diversion Case Study
To mitigate the impact of global climate change, countries worldwide must take necessary measures to address this environmental issue. China’s goals of carbon peaking and carbon neutrality and the “1 + N” policy framework have provided guidance for various industries and enterprises in advancing carbon accounting, carbon reduction, and green transformation. This study focuses on the sludge dewatering facility of a typical water treatment plant, which uses water from the South-to-North Water Diversion Project as its water source. Based on its construction and operational data, the carbon emissions at different phases were calculated with the emission factor method in the study, and the composition of these emissions was analyzed. The results show that during the three-year construction period, the sludge dewatering facility emitted a total of 1385.57 tons of CO2-eq, with materials being the main source of carbon emissions. While in the one-year operation period, the facility generated 19.38 tons of CO2-eq only, with electricity consumption being the primary contributor, followed by chemicals consumption. In conclusion, both the short-term intensive emissions during the construction phase and the long-term cumulative emissions during the operation phase should be considered, so that an integrated mitigation effect can be achieved across the construction and operation stages. This highlights the necessity of adopting a life-cycle perspective in carbon reduction strategies within the defined system boundary, while also supporting the sustainable planning and management of water treatment infrastructure.
- Open Access
Corrosion Characteristics of Iron Pipe in Reclaimed Water Disinfected by UV/NaClO
The use of reclaimed water is a crucial strategy for water conservation. However, the quality of reclaimed water may induce corrosion in pipelines. Although UV (Ultraviolet) irradiation is a highly effective physical disinfection method that requires no chemical additives, it must be used in conjunction with NaClO (Sodium hypochlorite) disinfection because UV alone cannot provide continuous control of bacterial growth. This study monitored the concentrations of Cl− and SO42− in water samples collected from an annular biofilm coupon reactor, as well as the corrosion rate of cast iron coupons, to explore the corrosion characteristics of reclaimed water pipelines under different disinfection modes. The results showed that, when using NaClO as the sole disinfectant, the corrosion rate of the pipeline was the lowest at a NaClO dosage of 7 mg/L (corrosion rate: 0.85 mm/a at 72 h). For the UV-NaClO-combined disinfection, the optimal parameters were a UV dose of 120 mJ/cm2 and a NaClO dosage of 5 mg/L, with a minimum corrosion rate of 0.62 mm/a at 72 h. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) analyses revealed that a protective CaCO3 layer forms on the pipe surface in the early corrosion stage, which effectively protects the metal pipeline. This study innovatively clarifies the synergistic effect of UV and NaClO on pipeline corrosion and identifies the optimal disinfection parameters, filling the research gap in the correlation between combined disinfection and cast iron pipe corrosion in reclaimed water systems.
Open AccessCorrosion Characteristics of Iron Pipe in Reclaimed Water Disinfected by UV/NaClO
The use of reclaimed water is a crucial strategy for water conservation. However, the quality of reclaimed water may induce corrosion in pipelines. Although UV (Ultraviolet) irradiation is a highly effective physical disinfection method that requires no chemical additives, it must be used in conjunction with NaClO (Sodium hypochlorite) disinfection because UV alone cannot provide continuous control of bacterial growth. This study monitored the concentrations of Cl− and SO42− in water samples collected from an annular biofilm coupon reactor, as well as the corrosion rate of cast iron coupons, to explore the corrosion characteristics of reclaimed water pipelines under different disinfection modes. The results showed that, when using NaClO as the sole disinfectant, the corrosion rate of the pipeline was the lowest at a NaClO dosage of 7 mg/L (corrosion rate: 0.85 mm/a at 72 h). For the UV-NaClO-combined disinfection, the optimal parameters were a UV dose of 120 mJ/cm2 and a NaClO dosage of 5 mg/L, with a minimum corrosion rate of 0.62 mm/a at 72 h. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) analyses revealed that a protective CaCO3 layer forms on the pipe surface in the early corrosion stage, which effectively protects the metal pipeline. This study innovatively clarifies the synergistic effect of UV and NaClO on pipeline corrosion and identifies the optimal disinfection parameters, filling the research gap in the correlation between combined disinfection and cast iron pipe corrosion in reclaimed water systems.
- Open Access
Comprehensive Evaluation of Urban Storm Flooding Resilience by Integrating AHP–Entropy Weight Method and Cloud Model
To address urban flooding challenges exacerbated by climate change and urbanization, this study develops an integrated assessment framework combining the analytic hierarchy process (AHP), entropy weight method, and cloud model to quantify urban flood resilience. Resilience is deconstructed into resistance, adaptability, and recovery and evaluated through 24 indicators spanning water resources, socio-economic systems, and ecological systems. Subjective (AHP) and objective (entropy) weights are optimized via minimum information entropy, with the cloud model enabling qualitative–quantitative resilience mapping. Analyzing 2014–2024 data from 27 Chinese sponge city pilots, the results show resilience improved from “poor to average” to “good to average”, with a 2.89% annual growth rate. Megacities like Beijing and Shanghai excel in resistance and recovery due to infrastructure and economic strengths, while cities like Sanya enhance resilience via ecological restoration. Key drivers include water allocation (27.38%), economic system (18.41%), and social system (17.94%), with critical indicators being population density, secondary industry GDP ratio, and sewage treatment rate. Recommendations emphasize upgrading rainwater storage, intelligent monitoring networks, and resilience-oriented planning. The model offers a scientific foundation for urban disaster risk management, supporting sustainable development. This approach enables systematic improvements in adaptive capacity and recovery potential, providing actionable insights for global flood-resilient urban planning.
Open AccessComprehensive Evaluation of Urban Storm Flooding Resilience by Integrating AHP–Entropy Weight Method and Cloud Model
To address urban flooding challenges exacerbated by climate change and urbanization, this study develops an integrated assessment framework combining the analytic hierarchy process (AHP), entropy weight method, and cloud model to quantify urban flood resilience. Resilience is deconstructed into resistance, adaptability, and recovery and evaluated through 24 indicators spanning water resources, socio-economic systems, and ecological systems. Subjective (AHP) and objective (entropy) weights are optimized via minimum information entropy, with the cloud model enabling qualitative–quantitative resilience mapping. Analyzing 2014–2024 data from 27 Chinese sponge city pilots, the results show resilience improved from “poor to average” to “good to average”, with a 2.89% annual growth rate. Megacities like Beijing and Shanghai excel in resistance and recovery due to infrastructure and economic strengths, while cities like Sanya enhance resilience via ecological restoration. Key drivers include water allocation (27.38%), economic system (18.41%), and social system (17.94%), with critical indicators being population density, secondary industry GDP ratio, and sewage treatment rate. Recommendations emphasize upgrading rainwater storage, intelligent monitoring networks, and resilience-oriented planning. The model offers a scientific foundation for urban disaster risk management, supporting sustainable development. This approach enables systematic improvements in adaptive capacity and recovery potential, providing actionable insights for global flood-resilient urban planning.
- Open Access
Biofilm Characteristics and Microbial Community Structure in Pipeline Systems Using Tea Polyphenols as Disinfectant
Polyphenols show promising application prospects as a novel natural disinfectant for drinking water. This study employed a simulated pipe network system to investigate the effects of tea polyphenols at an initial concentration of 5 mg/L on the characteristics of biofilm on pipe walls and microbial community succession patterns under different water ages (12–48 h). The results showed that with increasing water age, the tea polyphenol residual concentration gradually decreased, and the biofilm structure significantly evolved: the surface roughness increased from 5.57 nm to 32.8 nm, and the biofilm thickness increased from 40 nm to 150 nm. Microbial community diversity exhibited a trend of first increasing and then decreasing, with the Shannon index reaching its peak (2.847) at a water age of 36 h and remaining significantly higher than the control group (1.336) at all stages. High-throughput sequencing revealed a transition from a single dominant genus of Methylophilus (54.41%) at a water age of 12 h to a multi-genus coexistence pattern at a water age of 48 h, with Methylophilus (24.33%), unclassified_Saprospiraceae (21.70%), and Hydrogenophaga (16.52%) as the main dominant groups. Functional bacterial groups exhibited temporal changes, with biofilm colonization-related genera (Caulobacter, Sphingobium) reaching their peaks at 36 h, while special metabolic genera (Methylophilus, Hydrogenophaga) dominated at 48 h. Potential pathogens in the tea polyphenol treatment groups were effectively controlled at low levels (<0.21%), except for a temporary increase in Legionella (6.50%) at 36 h. Tea polyphenols’ selective inhibition mechanism helps suppress the excessive proliferation of specific genera and reduces the risk of potential pathogen outbreaks. This has important implications for ensuring the microbiological safety of drinking water.
Open AccessBiofilm Characteristics and Microbial Community Structure in Pipeline Systems Using Tea Polyphenols as Disinfectant
Polyphenols show promising application prospects as a novel natural disinfectant for drinking water. This study employed a simulated pipe network system to investigate the effects of tea polyphenols at an initial concentration of 5 mg/L on the characteristics of biofilm on pipe walls and microbial community succession patterns under different water ages (12–48 h). The results showed that with increasing water age, the tea polyphenol residual concentration gradually decreased, and the biofilm structure significantly evolved: the surface roughness increased from 5.57 nm to 32.8 nm, and the biofilm thickness increased from 40 nm to 150 nm. Microbial community diversity exhibited a trend of first increasing and then decreasing, with the Shannon index reaching its peak (2.847) at a water age of 36 h and remaining significantly higher than the control group (1.336) at all stages. High-throughput sequencing revealed a transition from a single dominant genus of Methylophilus (54.41%) at a water age of 12 h to a multi-genus coexistence pattern at a water age of 48 h, with Methylophilus (24.33%), unclassified_Saprospiraceae (21.70%), and Hydrogenophaga (16.52%) as the main dominant groups. Functional bacterial groups exhibited temporal changes, with biofilm colonization-related genera (Caulobacter, Sphingobium) reaching their peaks at 36 h, while special metabolic genera (Methylophilus, Hydrogenophaga) dominated at 48 h. Potential pathogens in the tea polyphenol treatment groups were effectively controlled at low levels (<0.21%), except for a temporary increase in Legionella (6.50%) at 36 h. Tea polyphenols’ selective inhibition mechanism helps suppress the excessive proliferation of specific genera and reduces the risk of potential pathogen outbreaks. This has important implications for ensuring the microbiological safety of drinking water.
- Open Access
- 1 July 2024
- Published by IWA Publishing in AQUA — Water Infrastructure, Ecosystems and Society
- Vol. 73 (7) , 1510-1524
Factors influencing the inactivation of Bacillus subtilis by epigallocatechin gallate (EGCG)
Epigallocatechin gallate (EGCG) is an exceptional plant polyphenol for drinking water disinfection, due to its lasting antibacterial capabilities and broad spectrum of health benefits. Nevertheless, its effectiveness and the underlying mechanisms against chlorine-resistant bacteria, such as Bacillus subtilis, have not been thoroughly explored under various water conditions. The study at hand probed the inactivation rates of EGCG on B. subtilis was subjected to different concentrations, contact times, acidic or basic environments, and temperatures; biological mechanisms were examined by analyzing alkaline phosphatase, proteins, glucose, ATP, and redox biomolecules. Results indicated a positive correlation between EGCG concentration and the inactivation rate of B. subtilis, with the rate notably rising at EGCG levels below 800 mg/l and under acidic pH. The inactivation efficiency increased with temperature increments from 25 to 45 °C. Moreover, EGCG exerted a detrimental impact on the structural integrity, energy metabolism, and the antioxidant defense system of B. subtilis showed a dose-dependent antimicrobial activity against Escherichia coli. Consequently, this study provides a strong foundation for evaluating EGCG's efficacy against chlorine-resistant bacteria, promoting its theoretical application for drinking water treatment and guiding methodological advancements for broader applications.
- 1 July 2024
- Published by IWA Publishing in AQUA — Water Infrastructure, Ecosystems and Society
- Vol. 73 (7) , 1510-1524
Open AccessFactors influencing the inactivation of Bacillus subtilis by epigallocatechin gallate (EGCG)
Epigallocatechin gallate (EGCG) is an exceptional plant polyphenol for drinking water disinfection, due to its lasting antibacterial capabilities and broad spectrum of health benefits. Nevertheless, its effectiveness and the underlying mechanisms against chlorine-resistant bacteria, such as Bacillus subtilis, have not been thoroughly explored under various water conditions. The study at hand probed the inactivation rates of EGCG on B. subtilis was subjected to different concentrations, contact times, acidic or basic environments, and temperatures; biological mechanisms were examined by analyzing alkaline phosphatase, proteins, glucose, ATP, and redox biomolecules. Results indicated a positive correlation between EGCG concentration and the inactivation rate of B. subtilis, with the rate notably rising at EGCG levels below 800 mg/l and under acidic pH. The inactivation efficiency increased with temperature increments from 25 to 45 °C. Moreover, EGCG exerted a detrimental impact on the structural integrity, energy metabolism, and the antioxidant defense system of B. subtilis showed a dose-dependent antimicrobial activity against Escherichia coli. Consequently, this study provides a strong foundation for evaluating EGCG's efficacy against chlorine-resistant bacteria, promoting its theoretical application for drinking water treatment and guiding methodological advancements for broader applications.
- 13 June 2024
- Published by Elsevier in Environmental Pollution
- Vol. 356, 124364
Study on the inactivation effect and mechanism of EGCG disinfectant on Bacillus subtilis
- 13 June 2024
- Published by Elsevier in Environmental Pollution
- Vol. 356, 124364
Study on the inactivation effect and mechanism of EGCG disinfectant on Bacillus subtilis
- 13 May 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 10 (8) , 1881-1889
Acoustic-based approach for micro-leakage detection and localization in water supply pipelines
Improving the accuracy of acoustic detection techniques is crucial, especially in scenarios with low pipeline pressures (≤0.2 MPa) and small leak apertures (≤2 mm), where micro-leakage detection poses challenges.
- 13 May 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 10 (8) , 1881-1889
Acoustic-based approach for micro-leakage detection and localization in water supply pipelines
Improving the accuracy of acoustic detection techniques is crucial, especially in scenarios with low pipeline pressures (≤0.2 MPa) and small leak apertures (≤2 mm), where micro-leakage detection poses challenges.