Kumaravel Sureshkumar
Kumaravel Sureshkumar has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Ponnusamy Vijayakumar
Department of Electronics and Communication Engineering, PSG Institute of Technology and Applied Research, Coimbatore, India
1 shared publication - Vijayakumar Ponnusamy
Karpagam College of Engineering, Coimbatore, Tamilnadu, India
1 shared publication
Latest Publications
- 14 December 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 46 (1) , 12721-12741
An Efficient Hybrid Technique for Power Flow Management in Smart Grid with Renewable Energy Resources
In this paper, an optimal power flow management of a hybrid renewable energy source (HRES) with a hybrid approach is proposed. Here, the proposed method is the consolidation of Improved Bear Smell Search (IBSS) and Sparrow Search Algorithm (SSA); hence, it is named as IB4SA technique. Here, the IBSS generates the voltage source inverter control signals based on the power exchange variety between the source side and load side. In the proposed work, the Bear Smell Search (BSS) is incorporated by crossover and mutation function, therefore it is named as IBSS. The multi-objective function is designed by the grid needed active with reactive power varieties generated based on the available source power. SSA process guarantees the detection of online control signals using a parallel implementation against active with reactive power varieties. The control method based on the proposed approach improves the control parameters of the power controller under power flow variations. The power flow management of the smart-grid system is controlled using the proposed technique based on variations in the parameters of the source and load side. The proposed technique is responsible for controlling energy sources using both renewable energy sources and energy storage devices, in order to generate the power requirement by the grid. The proposed approach is executed in MATLAB/Simulink work site and the performance is analyzed with the existing approaches. The statistical analysis for Case 1, 2, and 3 using proposed as well as existing approaches are analyzed. In Case 1, using the proposed technique the parameter of with mean represents 0.528, median represents 0.512 and standard deviation represents 0.033. In Case 2, using the proposed technique the parameter of with mean implies 0.671, median implies 0.656, and standard deviation implies 0.026.- 14 December 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 46 (1) , 12721-12741
An Efficient Hybrid Technique for Power Flow Management in Smart Grid with Renewable Energy Resources
In this paper, an optimal power flow management of a hybrid renewable energy source (HRES) with a hybrid approach is proposed. Here, the proposed method is the consolidation of Improved Bear Smell Search (IBSS) and Sparrow Search Algorithm (SSA); hence, it is named as IB4SA technique. Here, the IBSS generates the voltage source inverter control signals based on the power exchange variety between the source side and load side. In the proposed work, the Bear Smell Search (BSS) is incorporated by crossover and mutation function, therefore it is named as IBSS. The multi-objective function is designed by the grid needed active with reactive power varieties generated based on the available source power. SSA process guarantees the detection of online control signals using a parallel implementation against active with reactive power varieties. The control method based on the proposed approach improves the control parameters of the power controller under power flow variations. The power flow management of the smart-grid system is controlled using the proposed technique based on variations in the parameters of the source and load side. The proposed technique is responsible for controlling energy sources using both renewable energy sources and energy storage devices, in order to generate the power requirement by the grid. The proposed approach is executed in MATLAB/Simulink work site and the performance is analyzed with the existing approaches. The statistical analysis for Case 1, 2, and 3 using proposed as well as existing approaches are analyzed. In Case 1, using the proposed technique the parameter of with mean represents 0.528, median represents 0.512 and standard deviation represents 0.033. In Case 2, using the proposed technique the parameter of with mean implies 0.671, median implies 0.656, and standard deviation implies 0.026.- Retracted
- 3 March 2020
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 42 (11) , 2068-2087
RETRACTED: Hybrid renewable energy systems for power flow management in smart grid using an efficient hybrid technique
Efficient approach for power flow management of hybrid renewable energy system connected smart grid system is proposed in this paper. Here, the proposed approach is the combination of both the modified elephant herding optimization algorithm with tabu search algorithm named as MEHOTSA. In the proposed technique, the modified elephant herding optimization algorithm plays out the assessment procedure to establish the exact control signals for the system and builds up the control signals database for the offline way in light of the power variety between source side and the load side. The multi-objective function is shaped by the grid required active power and reactive power varieties generated based on the accessible source power. The accomplished dataset is used to work the Tabu search algorithm on the online way and it leads the control procedure in less execution time. The proposed technique-based control model enhances the control parameters of the power controller in light of the power flow varieties. By utilizing the proposed methodology, the power flow management of the smart grid system is controlled dependent on the source side and load side parameters varieties. Additionally, the proposed methodology is in charge of controlling the energy sources so as to produce the power demanded by the grid, utilizing optimally both renewable energy sources and energy storage devices. Finally, the proposed model be actualized in MATLAB/Simulink platform and the performance are compared with other techniques.
- 3 March 2020
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 42 (11) , 2068-2087
RetractedRETRACTED: Hybrid renewable energy systems for power flow management in smart grid using an efficient hybrid technique
Efficient approach for power flow management of hybrid renewable energy system connected smart grid system is proposed in this paper. Here, the proposed approach is the combination of both the modified elephant herding optimization algorithm with tabu search algorithm named as MEHOTSA. In the proposed technique, the modified elephant herding optimization algorithm plays out the assessment procedure to establish the exact control signals for the system and builds up the control signals database for the offline way in light of the power variety between source side and the load side. The multi-objective function is shaped by the grid required active power and reactive power varieties generated based on the accessible source power. The accomplished dataset is used to work the Tabu search algorithm on the online way and it leads the control procedure in less execution time. The proposed technique-based control model enhances the control parameters of the power controller in light of the power flow varieties. By utilizing the proposed methodology, the power flow management of the smart grid system is controlled dependent on the source side and load side parameters varieties. Additionally, the proposed methodology is in charge of controlling the energy sources so as to produce the power demanded by the grid, utilizing optimally both renewable energy sources and energy storage devices. Finally, the proposed model be actualized in MATLAB/Simulink platform and the performance are compared with other techniques.