Kate Groves
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kate Groves has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
Milena Quaglia
LGC, Queens Road, Teddington, Middlesex TQ11 0LY, United Kingdom
4 shared publications- Paul Anthony Dalby
Department of Biochemical Engineering University College London London UK
4 shared publications Paul Matejtschuk
Standardisation Science, NIBSC, Medicines & Healthcare Products Regulatory Agency, South Mimms, Hertfordshire EN6 3QG, United Kingdom
3 shared publicationsVictoria E. Wood
Department of Biochemical Engineering, University College London, London WC1E 6BT, United Kingdom
3 shared publicationsA Bahadoor
Measurement Science and Standards - National Research Council of Canada (NRC), Ottawa, Canada
2 shared publicationsA Boeuf
Laboratoire National de Métrologie et d'Essais (LNE), Paris, France
2 shared publications
Latest Publications
- Open Access
- 22 March 2024
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 21 (4) , 1965-1976
Investigation of the Solid-State Interactions in Lyophilized Human G-CSF Using Hydrogen–Deuterium Exchange Mass Spectrometry
Hydrogen/deuterium exchange mass spectrometry (HDX-MS) previously elucidated the interactions between excipients and proteins for liquid granulocyte colony stimulating factor (G-CSF) formulations, confirming predictions made using computational structure docking. More recently, solid-state HDX mass spectrometry (ssHDX-MS) was developed for proteins in the lyophilized state. Deuterium uptake in ssHDX-MS has been shown for various proteins, including monoclonal antibodies, to be highly correlated with storage stability, as measured by protein aggregation and chemical degradation. As G-CSF is known to lose activity through aggregation upon lyophilization, we applied the ssHDX-MS method with peptide mapping to four different lyophilized formulations of G-CSF to compare the impact of three excipients on local structure and exchange dynamics. HDX at 22 degrees C was confirmed to correlate well with the monomer content remaining after lyophilization and storage at -20 degrees C, with sucrose providing the greatest protection, and then phenylalanine, mannitol, and no excipient leading to progressively less protection. Storage at 45 degrees C led to little difference in final monomer content among the formulations, and so there was no discernible relationship with total deuterium uptake on ssHDX. Incubation at 45 degrees C may have led to a structural conformation and/or aggregation mechanism no longer probed by HDX at 22 degrees C. Such a conformational change was observed previously at 37 degrees C for liquid-formulated G-CSF using NMR. Peptide mapping revealed that tolerance to lyophilization and -20 degrees C storage was linked to increased stability in the small helix, loop AB, helix C, and loop CD. LC-MS HDX and NMR had previously linked loop AB and loop CD to the formation of a native-like state (N*) prior to aggregation in liquid formulations, suggesting a similar structural basis for G-CSF aggregation in the liquid and solid states.
- 22 March 2024
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 21 (4) , 1965-1976
Open AccessInvestigation of the Solid-State Interactions in Lyophilized Human G-CSF Using Hydrogen–Deuterium Exchange Mass Spectrometry
Hydrogen/deuterium exchange mass spectrometry (HDX-MS) previously elucidated the interactions between excipients and proteins for liquid granulocyte colony stimulating factor (G-CSF) formulations, confirming predictions made using computational structure docking. More recently, solid-state HDX mass spectrometry (ssHDX-MS) was developed for proteins in the lyophilized state. Deuterium uptake in ssHDX-MS has been shown for various proteins, including monoclonal antibodies, to be highly correlated with storage stability, as measured by protein aggregation and chemical degradation. As G-CSF is known to lose activity through aggregation upon lyophilization, we applied the ssHDX-MS method with peptide mapping to four different lyophilized formulations of G-CSF to compare the impact of three excipients on local structure and exchange dynamics. HDX at 22 degrees C was confirmed to correlate well with the monomer content remaining after lyophilization and storage at -20 degrees C, with sucrose providing the greatest protection, and then phenylalanine, mannitol, and no excipient leading to progressively less protection. Storage at 45 degrees C led to little difference in final monomer content among the formulations, and so there was no discernible relationship with total deuterium uptake on ssHDX. Incubation at 45 degrees C may have led to a structural conformation and/or aggregation mechanism no longer probed by HDX at 22 degrees C. Such a conformational change was observed previously at 37 degrees C for liquid-formulated G-CSF using NMR. Peptide mapping revealed that tolerance to lyophilization and -20 degrees C storage was linked to increased stability in the small helix, loop AB, helix C, and loop CD. LC-MS HDX and NMR had previously linked loop AB and loop CD to the formation of a native-like state (N*) prior to aggregation in liquid formulations, suggesting a similar structural basis for G-CSF aggregation in the liquid and solid states.
- 1 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1A)
Key comparison study on peptide purity - hexapeptide of HbA0
Main text: Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115.2018, was coordinated by the Bureau International des Poids et Mesures (BIPM), the Health Sciences Authority (HSA) of Singapore and the Chinese National Institute of Metrology (NIM). Ten Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of the hexapeptide of HbA0 (VE) present as the main component in the comparison sample for CCQM-K115.2018. The comparison samples were prepared by HSA/BIPM from synthetic VE purchased from a commercial supplier and used as provided without further treatment or purification. VE was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of chemically synthesized peptides of known sequence, without cross-links, up to 5 kDa and without modification. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used amino acid analysis (PICAA) with a correction for structurally-related peptide impurities approach as the amount of material that had been provided to each participant (25 mg) was insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, the BIPM, the HSA and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the VE mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the VE purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the VE mass fraction. In particular, it allowed participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification. More detailed studies on the identification/quantification of peptide related impurities revealed that the integrity of the impurity profile of the related peptide impurities obtained by the participant is crucial for the impact on accuracy of the VE mass fraction assignment. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most consistent set of results is taken for the calculation of the KCRVPepImp. The sum of the combined cis/trans VE depsipeptide impurities (only identified/quantified by NRC and confirmed by BIPM and HSA) and mass fractions of peptide related impurities that have been identified by at least two participants have been used to establish the KCRVPepImp. The KCRVPepImp of 53.0 mg/g is associated with a corresponding expanded uncertainty of 17.3 mg/g (k = 2) providing a more realistic basis of evaluation for the capabilities of the participants to identify/quantify peptide related impurities. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in all cases the major related peptide impurity, VE depsipeptide, has not been identified. The VE depsipeptide impurity was initially and uniquely identified and quantified by the NRC by the use of 1H-NMR. The related peptide impurity mass fraction results of only four participants (NRC, LGC, LNE and HSA) are in agreement with the KCRVPepImp. The NRC has identified and quantified the VE depsipeptide whereas the LGC, LNE and HSA have not identified the VE depsipeptide but accounted for that contribution. The approach selected to obtain a KCRVVE for the mass fraction of VE is based on a mass balance calculation that takes into account the most consistent set of results for the peptide related impurities KCRVPepImp, TFA mass fraction and the water mass fraction. The KCRVVE for CCQM-K115.2018 is 613 mg/g with a corresponding expanded uncertainty of the KCRVVE of 20 mg/g (k = 2). To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1A)
Key comparison study on peptide purity - hexapeptide of HbA0
Main text: Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115.2018, was coordinated by the Bureau International des Poids et Mesures (BIPM), the Health Sciences Authority (HSA) of Singapore and the Chinese National Institute of Metrology (NIM). Ten Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of the hexapeptide of HbA0 (VE) present as the main component in the comparison sample for CCQM-K115.2018. The comparison samples were prepared by HSA/BIPM from synthetic VE purchased from a commercial supplier and used as provided without further treatment or purification. VE was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of chemically synthesized peptides of known sequence, without cross-links, up to 5 kDa and without modification. It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used amino acid analysis (PICAA) with a correction for structurally-related peptide impurities approach as the amount of material that had been provided to each participant (25 mg) was insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, the BIPM, the HSA and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the VE mass fraction and the mass fraction of the peptide related impurities as indispensable contributor regardless of the use of PICAA, mass balance or any other approach to determine the VE purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the VE mass fraction. In particular, it allowed participants to demonstrate the efficacy of their implementation of peptide related impurity identification and quantification. More detailed studies on the identification/quantification of peptide related impurities revealed that the integrity of the impurity profile of the related peptide impurities obtained by the participant is crucial for the impact on accuracy of the VE mass fraction assignment. The assessment of the mass fraction of peptide impurities is based on the assumption that only the most consistent set of results is taken for the calculation of the KCRVPepImp. The sum of the combined cis/trans VE depsipeptide impurities (only identified/quantified by NRC and confirmed by BIPM and HSA) and mass fractions of peptide related impurities that have been identified by at least two participants have been used to establish the KCRVPepImp. The KCRVPepImp of 53.0 mg/g is associated with a corresponding expanded uncertainty of 17.3 mg/g (k = 2) providing a more realistic basis of evaluation for the capabilities of the participants to identify/quantify peptide related impurities. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide related impurity profile indicates that in all cases the major related peptide impurity, VE depsipeptide, has not been identified. The VE depsipeptide impurity was initially and uniquely identified and quantified by the NRC by the use of 1H-NMR. The related peptide impurity mass fraction results of only four participants (NRC, LGC, LNE and HSA) are in agreement with the KCRVPepImp. The NRC has identified and quantified the VE depsipeptide whereas the LGC, LNE and HSA have not identified the VE depsipeptide but accounted for that contribution. The approach selected to obtain a KCRVVE for the mass fraction of VE is based on a mass balance calculation that takes into account the most consistent set of results for the peptide related impurities KCRVPepImp, TFA mass fraction and the water mass fraction. The KCRVVE for CCQM-K115.2018 is 613 mg/g with a corresponding expanded uncertainty of the KCRVVE of 20 mg/g (k = 2). To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1A)
Key comparison study on peptide purity - glycated hexapeptide of HbA1c
Main text: Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115.c, was coordinated by the Bureau International des Poids et Mesures (BIPM), the Health Sciences Authority (HSA) of Singapore and the Chinese National Institute of Metrology (NIM). Nine Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of the glycated hexapeptide of HbA1c (GE) present as the main component in the comparison sample for CCQM-K115.c. The comparison samples were prepared by HSA/BIPM from synthetic GE purchased from a commercial supplier and used as provided without further treatment or purification. GE was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of chemically synthesized peptides of known sequence, without cross-links, up to 5 kDa and modification (mono-glycation). It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used amino acid analysis (PICAA) or quantitative nuclear magnetic resonance (PICqNMR) spectroscopy with a correction for structurally-related peptide impurities approach as the amount of material that has been provided to each participant (25 mg) is insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, the BIPM, the HSA and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the GE mass fraction and the mass fraction of the peptide-related impurities as indispensable contributor regardless of the use of PICAA, PICqNMR or mass balance to determine the GE purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the GE mass fraction. In particular, it allows participants to demonstrate the efficacy of their implementation of peptide-related impurity identification and quantification. More detailed studies on the identification/quantification of peptide-related impurities revealed that the integrity of the impurity profile of the related peptide impurities obtained by the participant is crucial for the impact on accuracy of the GE mass fraction assignment. The assessment of the mass fraction of peptide impurities is based on the assumption that that all results are directly taken for the calculation of the KCRVPepImp by use of random-effects meta-analysis (DerSimonian-Laird (DSL) variance-weighted mean). The KCRVPepImp of 45.4 mg/g is associated with a corresponding expanded uncertainty of 9.5 mg/g (k =2.26) providing a more realistic basis of evaluation for the capabilities of the participants to identify/quantify peptide-related impurities. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide-related impurity profile indicates that in most cases the major related peptide impurities have been identified and quantified. The approach selected to obtain a KCRVGE for the mass fraction of GE is based on the DerSimonian-Laird (DSL) variance-weighted mean. The DSL mean takes into account the uncertainties of the results while introducing sufficient excess variance to allow for their observed dispersion resulting in a larger expanded uncertainty U(KCRVGE). The KCRVGE for CCQM-K115.c is 628 mg/g with a corresponding expanded uncertainty of the KCRVGE of 27 mg/g (k =2.26). All GE mass fraction results are in agreement with the KCRVGE. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1A)
Key comparison study on peptide purity - glycated hexapeptide of HbA1c
Main text: Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM-K115.c, was coordinated by the Bureau International des Poids et Mesures (BIPM), the Health Sciences Authority (HSA) of Singapore and the Chinese National Institute of Metrology (NIM). Nine Metrology Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of the glycated hexapeptide of HbA1c (GE) present as the main component in the comparison sample for CCQM-K115.c. The comparison samples were prepared by HSA/BIPM from synthetic GE purchased from a commercial supplier and used as provided without further treatment or purification. GE was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of chemically synthesized peptides of known sequence, without cross-links, up to 5 kDa and modification (mono-glycation). It was anticipated to provide an analytical measurement challenge representative for the value-assignment of compounds of broadly similar structural characteristics. The majority of participants used amino acid analysis (PICAA) or quantitative nuclear magnetic resonance (PICqNMR) spectroscopy with a correction for structurally-related peptide impurities approach as the amount of material that has been provided to each participant (25 mg) is insufficient to perform a full mass balance based characterization of the material by a participating laboratory. The coordinators, the BIPM, the HSA and the NIM, were the laboratories to use the mass balance approach as they had more material available. It was decided to propose KCRVs for both the GE mass fraction and the mass fraction of the peptide-related impurities as indispensable contributor regardless of the use of PICAA, PICqNMR or mass balance to determine the GE purity. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to determine the GE mass fraction. In particular, it allows participants to demonstrate the efficacy of their implementation of peptide-related impurity identification and quantification. More detailed studies on the identification/quantification of peptide-related impurities revealed that the integrity of the impurity profile of the related peptide impurities obtained by the participant is crucial for the impact on accuracy of the GE mass fraction assignment. The assessment of the mass fraction of peptide impurities is based on the assumption that that all results are directly taken for the calculation of the KCRVPepImp by use of random-effects meta-analysis (DerSimonian-Laird (DSL) variance-weighted mean). The KCRVPepImp of 45.4 mg/g is associated with a corresponding expanded uncertainty of 9.5 mg/g (k =2.26) providing a more realistic basis of evaluation for the capabilities of the participants to identify/quantify peptide-related impurities. Inspection of the degree of equivalence plots for the mass fraction of peptide impurities and additional information obtained from the peptide-related impurity profile indicates that in most cases the major related peptide impurities have been identified and quantified. The approach selected to obtain a KCRVGE for the mass fraction of GE is based on the DerSimonian-Laird (DSL) variance-weighted mean. The DSL mean takes into account the uncertainties of the results while introducing sufficient excess variance to allow for their observed dispersion resulting in a larger expanded uncertainty U(KCRVGE). The KCRVGE for CCQM-K115.c is 628 mg/g with a corresponding expanded uncertainty of the KCRVGE of 27 mg/g (k =2.26). All GE mass fraction results are in agreement with the KCRVGE. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 29 December 2021
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 19 (2) , 616-629
Protein Engineering and HDX Identify Structural Regions of G-CSF Critical to Its Stability and Aggregation
The protein engineering and formulation of therapeutic proteins for prolonged shelf-life remain a major challenge in the biopharmaceutical industry. Understanding the influence of mutations and formulations on the protein structure and dynamics could lead to more predictive approaches to their improvement. Previous intrinsic fluorescence analysis of the chemically denatured granulocyte colony-stimulating factor (G-CSF) suggested that loop AB could subtly reorganize to form an aggregation-prone intermediate state. Hydrogen deuterium exchange mass spectrometry (HDX-MS) has also revealed that excipient binding increased the thermal unfolding transition midpoint (Tm) by stabilizing loop AB. Here, we have combined protein engineering with biophysical analyses and HDX-MS to reveal that increased exchange in a core region of the G-CSF comprising loop AB (ABI, a small helix, ABII) and loop CD packed onto helix B and the beginning of loop BC leads to a decrease in Tm and higher aggregation rates. Furthermore, some mutations can increase the population of the aggregation-prone conformation within the native ensemble, as measured by the greater local exchange within this core region.
- 29 December 2021
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 19 (2) , 616-629
Protein Engineering and HDX Identify Structural Regions of G-CSF Critical to Its Stability and Aggregation
The protein engineering and formulation of therapeutic proteins for prolonged shelf-life remain a major challenge in the biopharmaceutical industry. Understanding the influence of mutations and formulations on the protein structure and dynamics could lead to more predictive approaches to their improvement. Previous intrinsic fluorescence analysis of the chemically denatured granulocyte colony-stimulating factor (G-CSF) suggested that loop AB could subtly reorganize to form an aggregation-prone intermediate state. Hydrogen deuterium exchange mass spectrometry (HDX-MS) has also revealed that excipient binding increased the thermal unfolding transition midpoint (Tm) by stabilizing loop AB. Here, we have combined protein engineering with biophysical analyses and HDX-MS to reveal that increased exchange in a core region of the G-CSF comprising loop AB (ABI, a small helix, ABII) and loop CD packed onto helix B and the beginning of loop BC leads to a decrease in Tm and higher aggregation rates. Furthermore, some mutations can increase the population of the aggregation-prone conformation within the native ensemble, as measured by the greater local exchange within this core region.
- Open Access
- 24 June 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (26) , 9041-9048
Reference Protocol to Assess Analytical Performance of Higher Order Structural Analysis Measurements: Results from an Interlaboratory Comparison
Measurements of protein higher order structure (HOS) provide important information on stability, potency, efficacy, immunogenicity, and biosimilarity of biopharmaceuticals, with a significant number of techniques and methods available to perform these measurements. The comparison of the analytical performance of HOS methods and the standardization of the results is, however, not a trivial task, due to the lack of reference protocols and reference measurement procedures. Here, we developed a protocol to structurally alter and compare samples of somatropin, a recombinant biotherapeutic, and describe the results obtained by using a number of techniques, methods and in different laboratories. This, with the final aim to provide tools and generate a pool of data to compare and benchmark analytical platforms and define method sensitivity to structural changes. Changes in somatropin HOS, induced by the presence of zinc at increasing concentrations, were observed, both globally and at more localized resolution, across many of the methods utilized in this study and with different sensitivities, suggesting the suitability of the protocol to improve understanding of inter- and cross-platform measurement comparability and assess analytical performance as appropriate.
- 24 June 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (26) , 9041-9048
Open AccessReference Protocol to Assess Analytical Performance of Higher Order Structural Analysis Measurements: Results from an Interlaboratory Comparison
Measurements of protein higher order structure (HOS) provide important information on stability, potency, efficacy, immunogenicity, and biosimilarity of biopharmaceuticals, with a significant number of techniques and methods available to perform these measurements. The comparison of the analytical performance of HOS methods and the standardization of the results is, however, not a trivial task, due to the lack of reference protocols and reference measurement procedures. Here, we developed a protocol to structurally alter and compare samples of somatropin, a recombinant biotherapeutic, and describe the results obtained by using a number of techniques, methods and in different laboratories. This, with the final aim to provide tools and generate a pool of data to compare and benchmark analytical platforms and define method sensitivity to structural changes. Changes in somatropin HOS, induced by the presence of zinc at increasing concentrations, were observed, both globally and at more localized resolution, across many of the methods utilized in this study and with different sensitivities, suggesting the suitability of the protocol to improve understanding of inter- and cross-platform measurement comparability and assess analytical performance as appropriate.
- 28 October 2020
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 17 (12) , 4637-4651
HDX and In Silico Docking Reveal that Excipients Stabilize G-CSF via a Combination of Preferential Exclusion and Specific Hotspot Interactions
Assuring the stability of therapeutic proteins is a major challenge in the biopharmaceutical industry, and a better molecular understanding of the mechanisms through which formulations influence their stability is an ongoing priority. While the preferential exclusion effects of excipients are well known, the additional presence and impact of specific protein–excipient interactions have proven to be more elusive to identify and characterize. We have taken a combined approach of in silico molecular docking and hydrogen deuterium exchange-mass spectrometry (HDX-MS) to characterize the interactions between granulocyte colony-stimulating factor (G-CSF), and some common excipients. These interactions were related to their influence on the thermal-melting temperatures (Tm) for the nonreversible unfolding of G-CSF in liquid formulations. The residue-level interaction sites predicted in silico correlated well with those identified experimentally and highlighted the potential impact of specific excipient interactions on the Tm of G-CSF.
- 28 October 2020
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 17 (12) , 4637-4651
HDX and In Silico Docking Reveal that Excipients Stabilize G-CSF via a Combination of Preferential Exclusion and Specific Hotspot Interactions
Assuring the stability of therapeutic proteins is a major challenge in the biopharmaceutical industry, and a better molecular understanding of the mechanisms through which formulations influence their stability is an ongoing priority. While the preferential exclusion effects of excipients are well known, the additional presence and impact of specific protein–excipient interactions have proven to be more elusive to identify and characterize. We have taken a combined approach of in silico molecular docking and hydrogen deuterium exchange-mass spectrometry (HDX-MS) to characterize the interactions between granulocyte colony-stimulating factor (G-CSF), and some common excipients. These interactions were related to their influence on the thermal-melting temperatures (Tm) for the nonreversible unfolding of G-CSF in liquid formulations. The residue-level interaction sites predicted in silico correlated well with those identified experimentally and highlighted the potential impact of specific excipient interactions on the Tm of G-CSF.
- 21 January 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 31 (3) , 553-564
Mass Spectrometry Characterization of Higher Order Structural Changes Associated with the Fc-glycan Structure of the NISTmAb Reference Material, RM 8761
As monoclonal antibodies (mAbs) rapidly emerge as a dominant class of therapeutics, so does the need for suitable analytical technologies to monitor for changes in protein higher order structure (HOS) of these biomolecules. Reference materials (RM) serve a key analytical purpose of benchmarking the suitability and robustness of both established and emerging analytical procedures for both drug producers and regulators. Here, two simple enzymatic protocols for generating Fc-glycan variants from the NISTmAb RM are described and both global and localized changes in HOS between the RM and these Fc-glycan variants are characterized using hydrogen deuterium exchange–mass spectrometry (HDX–MS) and ion mobility spectrometry–mass spectrometry (IMS–MS) measurements. An alternative statistical approach is described where measurement thresholds that differentiate between measurement variability and significant structural changes were established on the basis of experimental data. Measurements revealed decreases in structural stability correlating with the degree of Fc-glycan structure loss, especially at the CH2/CH3 domain interface. These data promote the use of this RM and these Fc-glycan variants for establishing the sensitivity of and validating analytical methods for the detection of HOS measurements of mAbs.
- 21 January 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 31 (3) , 553-564
Mass Spectrometry Characterization of Higher Order Structural Changes Associated with the Fc-glycan Structure of the NISTmAb Reference Material, RM 8761
As monoclonal antibodies (mAbs) rapidly emerge as a dominant class of therapeutics, so does the need for suitable analytical technologies to monitor for changes in protein higher order structure (HOS) of these biomolecules. Reference materials (RM) serve a key analytical purpose of benchmarking the suitability and robustness of both established and emerging analytical procedures for both drug producers and regulators. Here, two simple enzymatic protocols for generating Fc-glycan variants from the NISTmAb RM are described and both global and localized changes in HOS between the RM and these Fc-glycan variants are characterized using hydrogen deuterium exchange–mass spectrometry (HDX–MS) and ion mobility spectrometry–mass spectrometry (IMS–MS) measurements. An alternative statistical approach is described where measurement thresholds that differentiate between measurement variability and significant structural changes were established on the basis of experimental data. Measurements revealed decreases in structural stability correlating with the degree of Fc-glycan structure loss, especially at the CH2/CH3 domain interface. These data promote the use of this RM and these Fc-glycan variants for establishing the sensitivity of and validating analytical methods for the detection of HOS measurements of mAbs.
- 1 April 2018
- Published by Elsevier in Food Chemistry
- Vol. 245, 289-296
Development of a LC-MS method for the discrimination between trace level Prunus contaminants of spices
- 1 April 2018
- Published by Elsevier in Food Chemistry
- Vol. 245, 289-296
Development of a LC-MS method for the discrimination between trace level Prunus contaminants of spices