Iván Valencia-Salazar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Iván Valencia-Salazar has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Elisa Peñalvo-López
Department of Electrical Engineering, Universitat Politécnica de Valencia, 46022 Valencia, Spain
9 shared publications - Vicente León-Martínez
Department of Electrical Engineering, Universitat Politécnica de Valencia, 46022 Valencia, Spain
6 shared publications - Amparo León-Vinet
Department of Electrical Engineering, Universitat Politécnica de Valencia, 46022 Valencia, Spain
3 shared publications - Clara Andrada-Monrós
Department of Electrical Engineering, Universitat Politécnica de Valencia, 46022 Valencia, Spain
3 shared publications - Joaquín Montañana-Romeu
Electrical Engineering Department, Universitat Politècnica de València, Camino de Vera 14, 46022 València, Spain
3 shared publications Araceli Rodríguez Andrade
1 shared publication
Latest Publications
- Open Access
- 7 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8898
Simulation Model for Electrical Operation in Agrivoltaic Power Plants: Nine Hourly Panel Orientation Modes
In an agrivoltaic plot, the hourly panel tracking angle governs electricity, on-site economics, avoided carbon dioxide, irrigation demand and crop yield. Operating for photovoltaic output alone discards that space, and does so when a midday kilowatt-hour has lost its value: 715 h of the studied season carried a non-positive export price, 517 of them at midday. This work formalizes the electrical operating layer of a mechanistic hourly simulator as nine panel-orientation modes, each a constrained program solved deterministically by sequential quadratic programming, a dense angular scan, or both. Two modes keep an energy-proportional objective non-degenerate through an adaptive clean-grid switch and an economics–carbon weighting anchored on the crop. The catalog is a framework, demonstrated over a 153-day season on a 66 kWp single-axis sage (Salvia officinalis) plot near Valencia, Spain. Seasonal photovoltaic energy ranged from 57.0 to 31.9 MWh, plot-mean relative yield from 95% to 109%, and worst-plant protection from 61% to 94%. Energy maximization sits at a flat extreme of the frontier: the Pareto mode gained 11.4 yield points and 31 worst-plant points for 1.1% less energy. Avoided carbon dioxide varied by 2.1% across the nine modes, so a carbon objective is degenerate with energy without an interior term.
- 7 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8898
Open AccessSimulation Model for Electrical Operation in Agrivoltaic Power Plants: Nine Hourly Panel Orientation Modes
In an agrivoltaic plot, the hourly panel tracking angle governs electricity, on-site economics, avoided carbon dioxide, irrigation demand and crop yield. Operating for photovoltaic output alone discards that space, and does so when a midday kilowatt-hour has lost its value: 715 h of the studied season carried a non-positive export price, 517 of them at midday. This work formalizes the electrical operating layer of a mechanistic hourly simulator as nine panel-orientation modes, each a constrained program solved deterministically by sequential quadratic programming, a dense angular scan, or both. Two modes keep an energy-proportional objective non-degenerate through an adaptive clean-grid switch and an economics–carbon weighting anchored on the crop. The catalog is a framework, demonstrated over a 153-day season on a 66 kWp single-axis sage (Salvia officinalis) plot near Valencia, Spain. Seasonal photovoltaic energy ranged from 57.0 to 31.9 MWh, plot-mean relative yield from 95% to 109%, and worst-plant protection from 61% to 94%. Energy maximization sits at a flat extreme of the frontier: the Pareto mode gained 11.4 yield points and 31 worst-plant points for 1.1% less energy. Avoided carbon dioxide varied by 2.1% across the nine modes, so a carbon objective is degenerate with energy without an interior term.
- Open Access
- 27 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (17) , 8808
Dynamic Agrivoltaic Power Optimization Driven by Energy–Crop Synergies: A Mechanistic Hourly Simulator Model
Most agrivoltaic (APV) models assemble stand-alone tools ex post and optimize panel orientation for energy alone. It remains an open question whether the energy resource of an APV plot (its generation, storage, and shiftable demand) can instead be optimized at the resolution of the individual module while still guaranteeing that crop needs are met. This paper addresses that question with a mechanistic, hourly, spatially resolved framework in which the panel-orientation optimizer is embedded inside the hourly loop, ahead of the radiation sub-model, so every candidate orientation is evaluated through the full geometric chain it would produce rather than from cached values. Four operating modes (pure energy, energy under a crop-yield floor, pure yield, and yield under an energy floor) make the energy–yield trade-off an explicit decision variable that can be posed against a regulatory yield threshold. Over a full growing season (1 May–31 October 2021) for a Citrus limon orchard in Valencia, Spain (39.47391° N, 0.37966° W), the modes span 45.0–85.3 MWh of generation and 74.8–100.5% relative crop yield, with Land Equivalent Ratios of 1.37–1.48 and LCOE of 0.097–0.183 EUR/kWh.
- 27 August 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (17) , 8808
Open AccessDynamic Agrivoltaic Power Optimization Driven by Energy–Crop Synergies: A Mechanistic Hourly Simulator Model
Most agrivoltaic (APV) models assemble stand-alone tools ex post and optimize panel orientation for energy alone. It remains an open question whether the energy resource of an APV plot (its generation, storage, and shiftable demand) can instead be optimized at the resolution of the individual module while still guaranteeing that crop needs are met. This paper addresses that question with a mechanistic, hourly, spatially resolved framework in which the panel-orientation optimizer is embedded inside the hourly loop, ahead of the radiation sub-model, so every candidate orientation is evaluated through the full geometric chain it would produce rather than from cached values. Four operating modes (pure energy, energy under a crop-yield floor, pure yield, and yield under an energy floor) make the energy–yield trade-off an explicit decision variable that can be posed against a regulatory yield threshold. Over a full growing season (1 May–31 October 2021) for a Citrus limon orchard in Valencia, Spain (39.47391° N, 0.37966° W), the modes span 45.0–85.3 MWh of generation and 74.8–100.5% relative crop yield, with Land Equivalent Ratios of 1.37–1.48 and LCOE of 0.097–0.183 EUR/kWh.
- Open Access
- 15 April 2026
- Published by Universidad de Sonora in BIOtecnia
- Vol. 28, e2882
Biophotolysis as a Sustainable Tool for Biohydrogen Production: A Systematic Review
Biophotolysis has emerged as a promising biotechnological alternative for the sustainable production of hydrogen, owing to the photosynthetic capacity of microalgae to convert solar energy into reducing equivalents under controlled conditions. This systematic review analyzed literature published between 2019 and 2024 in Science Direct, Scopus, and ResearchGate, with the objective of identifying the operational parameters, microorganisms, reactor configurations, and technological advances that determine process performance. Specific keywords and Boolean operators were applied to ensure a rigorous selection of recent studies. The findings indicate that Chlamydomonas reinhardtii is the most widely studied species, achieving hydrogen yields of up to 14.5 mL/L·h under optimized conditions such as sulfur deprivation, pH values between 7.0 and 7.5, moderate light intensities (100–200 μmol·m⁻²·s⁻¹), and enriched media such as TAP. Batch-type reactors demonstrated the highest efficiencies due to improved control of oxygen accumulation and light distribution, whereas tubular systems showed comparatively lower performance. This also reinforces the potential of biophotolysis for integrated bioremediation applications. Overall, biophotolysis represents a promising pathway for green hydrogen generation; however, its scalability requires further innovation in photobioreactor design, enzyme stability, and strategies to mitigate oxygen inhibition.
- 15 April 2026
- Published by Universidad de Sonora in BIOtecnia
- Vol. 28, e2882
Open AccessBiophotolysis as a Sustainable Tool for Biohydrogen Production: A Systematic Review
Biophotolysis has emerged as a promising biotechnological alternative for the sustainable production of hydrogen, owing to the photosynthetic capacity of microalgae to convert solar energy into reducing equivalents under controlled conditions. This systematic review analyzed literature published between 2019 and 2024 in Science Direct, Scopus, and ResearchGate, with the objective of identifying the operational parameters, microorganisms, reactor configurations, and technological advances that determine process performance. Specific keywords and Boolean operators were applied to ensure a rigorous selection of recent studies. The findings indicate that Chlamydomonas reinhardtii is the most widely studied species, achieving hydrogen yields of up to 14.5 mL/L·h under optimized conditions such as sulfur deprivation, pH values between 7.0 and 7.5, moderate light intensities (100–200 μmol·m⁻²·s⁻¹), and enriched media such as TAP. Batch-type reactors demonstrated the highest efficiencies due to improved control of oxygen accumulation and light distribution, whereas tubular systems showed comparatively lower performance. This also reinforces the potential of biophotolysis for integrated bioremediation applications. Overall, biophotolysis represents a promising pathway for green hydrogen generation; however, its scalability requires further innovation in photobioreactor design, enzyme stability, and strategies to mitigate oxygen inhibition.
- 1 March 2026
- Published by IATED Academy in INTED Proceedings
- Vol. 1, 1457
CO-DESIGNING AN INNOVATIVE HEAT PUMP EDUCATIONAL TRAINING PROGRAMME: THE PUMP-UP APPROACH
- 1 March 2026
- Published by IATED Academy in INTED Proceedings
- Vol. 1, 1457
CO-DESIGNING AN INNOVATIVE HEAT PUMP EDUCATIONAL TRAINING PROGRAMME: THE PUMP-UP APPROACH
- Open Access
- 8 August 2024
- Published by Elsevier in e-Prime - Advances in Electrical Engineering, Electronics and Energy
- Vol. 9
Assessing energy transition in Mediterranean islands. A review
- 8 August 2024
- Published by Elsevier in e-Prime - Advances in Electrical Engineering, Electronics and Energy
- Vol. 9
Open AccessAssessing energy transition in Mediterranean islands. A review
- Open Access
Renewable Energy Use for Buildings Decarbonization Causes Inequity in Consumers? Comparative Analysis of Spain, Mexico, and Colombia
Building decarbonization strategy with Distributed renewable energy sources (DRES) is applied and extended worldwide for its climate change mitigation benefits, however, it generates debate regarding equity in sharing electric system operation costs. To analyze DRES effects on equity, it is conducted a case study, in which same residential consumer is evaluated in three different markets (Spain, Mexico, Colombia). We analyze not only electrical system technical variables, but we also include society’s economic, social, technological, and environmental characteristics. Next, energy, economic, and environmental benefits are obtained in each the three case studies, analyzing the impact of using DERS on equity to recover electric system operating costs. We also evaluate whether tariff mechanisms are equitable to motivate all consumers participation, as well as whether all consumers have equal opportunity for using DERS. We conclude that tariff mechanisms in Mexico and Colombia lead to inequity to recover market operating costs, favoring large consumers with high incomes. Furthermore, tariff mechanisms discourage the use of DERS by small and medium consumers due to economic, social, and technological aspects. In Spain, inequity arises due to increased difficulty for some consumers to use DERS, i.e., consumers in apartment buildings.
Open AccessRenewable Energy Use for Buildings Decarbonization Causes Inequity in Consumers? Comparative Analysis of Spain, Mexico, and Colombia
Building decarbonization strategy with Distributed renewable energy sources (DRES) is applied and extended worldwide for its climate change mitigation benefits, however, it generates debate regarding equity in sharing electric system operation costs. To analyze DRES effects on equity, it is conducted a case study, in which same residential consumer is evaluated in three different markets (Spain, Mexico, Colombia). We analyze not only electrical system technical variables, but we also include society’s economic, social, technological, and environmental characteristics. Next, energy, economic, and environmental benefits are obtained in each the three case studies, analyzing the impact of using DERS on equity to recover electric system operating costs. We also evaluate whether tariff mechanisms are equitable to motivate all consumers participation, as well as whether all consumers have equal opportunity for using DERS. We conclude that tariff mechanisms in Mexico and Colombia lead to inequity to recover market operating costs, favoring large consumers with high incomes. Furthermore, tariff mechanisms discourage the use of DERS by small and medium consumers due to economic, social, and technological aspects. In Spain, inequity arises due to increased difficulty for some consumers to use DERS, i.e., consumers in apartment buildings.
- Open Access
Evaluation of Sinusoidal Distribution Networks Using the EPC Simulation Software
The electric power calculator (EPC) software, for the simulation and analysis of electrical networks at the industrial frequency, is described in this article, including its source code and operational diagram. Compared to well-known commercial software, EPC directly provides the values of the voltages, currents, and powers in each subsystem. The voltages and currents are calculated, in phasor notation, applying Kirchhoff’s laws, while the powers are obtained through the components of the apparent power vector. In this paper, the EPC software could be applied to three-phase networks made up of a distribution transformer and two three-phase wye-configured loads. The correctness of the results of the EPC software was verified by comparison with those obtained using the Multisim commercial software and with the measurements recorded by the Fluke 435 analyzer in a real distribution network of residential buildings. The values of the voltages and currents provided by the EPC were the same as those measured by the Fluke, and the differences observed using Multisim were less than 0.6%. Consequently, the EPC software is an excellent complement for power analyzers, because it is capable of providing measurements in all the network subsystems at the same time, using a single analyzer.
Open AccessEvaluation of Sinusoidal Distribution Networks Using the EPC Simulation Software
The electric power calculator (EPC) software, for the simulation and analysis of electrical networks at the industrial frequency, is described in this article, including its source code and operational diagram. Compared to well-known commercial software, EPC directly provides the values of the voltages, currents, and powers in each subsystem. The voltages and currents are calculated, in phasor notation, applying Kirchhoff’s laws, while the powers are obtained through the components of the apparent power vector. In this paper, the EPC software could be applied to three-phase networks made up of a distribution transformer and two three-phase wye-configured loads. The correctness of the results of the EPC software was verified by comparison with those obtained using the Multisim commercial software and with the measurements recorded by the Fluke 435 analyzer in a real distribution network of residential buildings. The values of the voltages and currents provided by the EPC were the same as those measured by the Fluke, and the differences observed using Multisim were less than 0.6%. Consequently, the EPC software is an excellent complement for power analyzers, because it is capable of providing measurements in all the network subsystems at the same time, using a single analyzer.
- Open Access
Study of the Improvement on Energy Efficiency for a Building in the Mediterranean Area by the Installation of a Green Roof System
Rooftop gardens ona building have proved to be a good way to improve its storm water management, but many other benefits can be obtained from the installation of these systems, such as reduction of energy consumption, decrease of the heat stress, abatement on CO2 emissions, etc. In this paper, the effect from the presence of these rooftop gardens on abuilding’s energy consumption has been investigated by experimental campaigns using a green roof ona public building in a Mediterranean location in Spain. The obtained results demonstrate a substantial improvement by the installation of the green roof onthe building’s cooling energy demand for a standard summer day, in the order of 30%, and a reduction, about 15%, in the heating energy demand for a winter day. Thus, given the longer duration of the summer conditions along the year, a noticeable reduction on energy demand could be obtained. Simulation analysis, using commercial software TRNSYS code, previously calibrated using experimental data for typical summer and winter days, allows for the extrapolation to the entire year of these results deducing noticeable improvement in energy efficiency, in the order of 19%, but with an increase of 6% in the peak power during the winter period.
Open AccessStudy of the Improvement on Energy Efficiency for a Building in the Mediterranean Area by the Installation of a Green Roof System
Rooftop gardens ona building have proved to be a good way to improve its storm water management, but many other benefits can be obtained from the installation of these systems, such as reduction of energy consumption, decrease of the heat stress, abatement on CO2 emissions, etc. In this paper, the effect from the presence of these rooftop gardens on abuilding’s energy consumption has been investigated by experimental campaigns using a green roof ona public building in a Mediterranean location in Spain. The obtained results demonstrate a substantial improvement by the installation of the green roof onthe building’s cooling energy demand for a standard summer day, in the order of 30%, and a reduction, about 15%, in the heating energy demand for a winter day. Thus, given the longer duration of the summer conditions along the year, a noticeable reduction on energy demand could be obtained. Simulation analysis, using commercial software TRNSYS code, previously calibrated using experimental data for typical summer and winter days, allows for the extrapolation to the entire year of these results deducing noticeable improvement in energy efficiency, in the order of 19%, but with an increase of 6% in the peak power during the winter period.
- Open Access
- 5 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (5) , 1798
Relationship between Buchholz’s Apparent Power and Instantaneous Power in Three-Phase Systems
Similarly to how Steinmetz developed his theory of alternating current in single-phase sinusoidal systems, a few formal relationships between expressions of the instantaneous and Buchholz’s apparent power in three-phase systems were identified in this paper. Based on these relationships, a methodology to express Buchholz’s apparent power and its components in any three-phase, wye-configured system—sinusoidal or non-sinusoidal, balanced or unbalanced—through instantaneous power expressions was established. The application of the proposed method to the entire system allowed the determination of a novel quantity referred to as neutral-displacement power, which measured the impacts of the phenomena caused by the neutral path operation on the values of the source and load apparent power. These impacts were analyzed using a real-world urban installation with a neutral conductor deterioration simulation via an Excel platform as an application example.
- 5 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (5) , 1798
Open AccessRelationship between Buchholz’s Apparent Power and Instantaneous Power in Three-Phase Systems
Similarly to how Steinmetz developed his theory of alternating current in single-phase sinusoidal systems, a few formal relationships between expressions of the instantaneous and Buchholz’s apparent power in three-phase systems were identified in this paper. Based on these relationships, a methodology to express Buchholz’s apparent power and its components in any three-phase, wye-configured system—sinusoidal or non-sinusoidal, balanced or unbalanced—through instantaneous power expressions was established. The application of the proposed method to the entire system allowed the determination of a novel quantity referred to as neutral-displacement power, which measured the impacts of the phenomena caused by the neutral path operation on the values of the source and load apparent power. These impacts were analyzed using a real-world urban installation with a neutral conductor deterioration simulation via an Excel platform as an application example.