JGJuan Carlos Castro Galeano

Juan Carlos Castro Galeano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juan Carlos Castro Galeano has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reproducible State-of-Charge and Range Evaluation of a 350 W Electric Scooter Under an Urban NEDC Driving Cycle

    by Juan C. Castro-Galeano, Edgar E. Tibaduiza-Rincon, Freddy F. Valderrama

    This article presents an experimental–computational methodology for evaluating the state of charge (SoC), energy consumption, terminal-voltage behavior, and driving range of a 350 W electric scooter powered by a 36 V, 7.8 Ah lithium-ion battery. The test was carried out using a 117 s elementary urban driving cycle derived from the low-speed section of the New European Driving Cycle (NEDC) and limited to the 32 km/h operating speed of the scooter. Laboratory measurements were performed on rollers under controlled conditions. Battery current and terminal voltage were recorded during the discharge test. The experimental SoC was reconstructed from the measured current by trapezoidal Coulomb counting. The voltage-derived SoC values included in the original laboratory file were kept only for traceability, since they did not correspond to current integration. A MATLAB/Simulink model was developed to reproduce the driving cycle, longitudinal vehicle dynamics, DC motor demand, battery current, and SoC evolution. The valid experimental endpoint occurred at 5233 s, when the terminal voltage reached 31.50 V. At this point, the tested distance was 16.49 km, the discharged capacity was 5.817 Ah, and the final experimental SoC was 25.42%. The simulation produced a discharged capacity of 5.147 Ah and a final SoC of 34.01%, with a charge deviation of 11.51%. Energy consumption was also evaluated from the measured and simulated electrical power. The experimentally integrated discharged energy was 208.10 Wh, equivalent to 12.62 Wh/km. The simulated electrical demand was 184.41 Wh, equivalent to 11.18 Wh/km. A semiempirical terminal-voltage reconstruction, based on the simulated SoC, current demand, an open-circuit-voltage curve, and a fixed internal resistance, reproduced the global voltage-decay trend observed in the experiment. The simplified model captured the general discharge behavior, although it underestimated the measured charge and energy demand. The proposed workflow provides a reproducible basis for comparing manufacturer-declared range, laboratory measurements, current-based SoC reconstruction, energy consumption, and simplified simulation results in light electric vehicles.

  • Open Access

    Prospective Analysis of Massive Integration of Electric Vehicle Chargers and Their Impact on Power Quality in Distribution Networks

    by Juan B. Bernal-Vargas, Juan C. Castro-Galeano, Edgar E. Tibaduiza-Rincón, Jesús M. López-Lezama, Nicolás Muñoz-Galeano

    The increasing presence of electric vehicles (EVs) requires a thorough understanding of their impact on distribution assets. EV chargers are characterized as nonlinear and multi-state loads due to their unique electrical consumption patterns. This paper presents a comprehensive study focused on modelling diverse EV charging units deployed in the industrial, commercial, and residential sectors. To conduct this analysis, a simulation environment utilizing the ETAP tool is employed, taking into account time variations. This approach facilitates the comprehension and anticipation of the effects that EV charging may impose on distribution networks, thereby supporting well-informed decision-making for the adaptation and enhancement of the electrical system. Detailed data on current and voltage from operational EV charging stations were collected to create consumption, current, voltage, and harmonic profiles for these charging units. Subsequently, general models or libraries applicable to Level 1, Level 2 and Level 3 EV chargers available in Colombia were developed. These models underwent rigorous validation and were subjected to a comprehensive analysis using the IEEE 13-bus test system. The research yielded valuable insights and conclusions regarding the integration of EV chargers into the current Colombian distribution systems, as well as the potential impact of adopting these devices on power quality issues within the distribution grid. This study contributes to the improved management of distribution assets, thereby facilitating the integration of sustainable electric mobility in the national electrical system.


  • Open Access

    Creación de un laboratorio de ensayos dieléctricos en el departamento de Boyacá

    by Juan Carlos Castro Galeano, Elieser Emilio Carvajal Santos, Jesús María López Lezama

    Este trabajo presenta la creación de un laboratorio de ensayos dieléctricos, en convenio entre la Empresa de Energía de Boyacá S.A. E.S.P (EBSA) y la Universidad Pedagógica y Tecnológica de Colombia (UPTC). La motivación surge en la búsqueda de mejorar los procesos de salud y seguridad en el trabajo de los operarios de trabajos con tensión TCT de la EBSA E.S.P., en la ejecución de las pruebas periódicas que deben ser realizadas a los elementos de protección personal empleados en TCT, además de evitar los desplazamientos de herramientas y vehículos grúa canasta aislados hasta otras ciudades para sus pruebas. Boyacá, ahora cuenta con un laboratorio de ensayos dieléctricos, siendo la principal contribución del trabajo, así también como el fortalecimiento de los vínculos Universidad-Empresa. El principal resultado ha sido la puesta en servicio del laboratorio con capacidad de prueba de hasta 130 kV para actividades de investigación, extensión y docencia. Este trabajo presenta la creación de un laboratorio de ensayos dieléctricos, en convenio entre la Empresa de Energía de Boyacá S.A. E.S.P (EBSA) y la Universidad Pedagógica y Tecnológica de Colombia (UPTC). La motivación surge en la búsqueda de mejorar los procesos de salud y seguridad en el trabajo de los operarios de trabajos con tensión TCT de la EBSA E.S.P., en la ejecución de las pruebas periódicas que deben ser realizadas a los elementos de protección personal empleados en TCT, además de evitar los desplazamientos de herramientas y vehículos grúa canasta aislados hasta otras ciudades para sus pruebas. Boyacá, ahora cuenta con un laboratorio de ensayos dieléctricos, siendo la principal contribución del trabajo, así también como el fortalecimiento de los vínculos Universidad-Empresa. El principal resultado ha sido la puesta en servicio del laboratorio con capacidad de prueba de hasta 130 kV para actividades de investigación, extensión y docencia.

  • Open Access

    Planning stand-alone electricity generation systems, a multiple objective optimization and fuzzy decision making approach

    by J.D. Rivera-Niquepa, P.M. De Oliveira-De Jesus, J.C. Castro-Galeano, D. Hernández-Torres


  • Open Access

    Fault and load flows analysis of electricity transmission and distribution system in Casanare (Colombia)

    by Juan Carlos Castro-Galeano, Wilson Javier Cabra-Sarmiento, Jhony Fernando Ortiz-Portilla

    This article describes a simulation of the electrical local distribution and regional transmission system of Enerca S.A. E.S.P. at 34.5 kV and 115 kV, identifying the most critical circuits and substations. The company is located in one of the major petroleum production areas in Colombia, and because of a massive growth in this sector, the electrical company expanded its networks in a radial way. This expansion was improvised and poorly planned due to the accelerated need to meet the new demand, which resulted in stability, balance, voltage regulation, and system reliability problems. Load flow and fault analyses were carried out based on current load and demand predictions in the short and medium term. Twelve proposals were made for network and substation modernization that once implemented will significantly improve the service reliability.