Hongyuan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongyuan Liu has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Chengran Fang
College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
4 shared publications Mingdi Yang
College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
3 shared publicationsQiaona Xie
College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
3 shared publicationsShijie Wu
College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
3 shared publicationsSiyi Li
College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
3 shared publications- Yawei Xie
College of Civil Engineering, Zhejiang University of Technology, Hangzhou 310032, China
3 shared publications
Latest Publications
- 1 September 2026
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 198 (9) , 1017
Microplastics and antibiotic resistance genes in landfills: interaction mechanisms, environmental risks, and composite pollution implications
- 1 September 2026
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 198 (9) , 1017
Microplastics and antibiotic resistance genes in landfills: interaction mechanisms, environmental risks, and composite pollution implications
- 24 April 2026
- Published by Elsevier in Journal of Environmental Management
- Vol. 405, 129761
Organic fractions in wastewater enabled simultaneous removal of NO3− and Cr(VI) under VUV185 irradiation
- 24 April 2026
- Published by Elsevier in Journal of Environmental Management
- Vol. 405, 129761
Organic fractions in wastewater enabled simultaneous removal of NO3− and Cr(VI) under VUV185 irradiation
- Open Access
Water Purification Efficiency and Membrane Fouling Behavior of Ceramic Membrane-Nanofiltration in Treating Water Treatment Plant Production Wastewater
To mitigate the risks associated with production wastewater from water treatment plants, this study evaluated the effectiveness of nanofiltration (NF) and a hybrid ceramic membrane–nanofiltration (CM–NF) process in removing natural organic matter (NOM) and Ca2+. A comprehensive analysis of changes in specific flux and fouling resistance of the NF membrane, combined with scanning electron microscopy (SEM) observations, provided deeper insight into membrane fouling behavior. The results show that the CM–NF process achieved average removal rates of 95.60% for DOC, 98.55% for UV254, 34.50% for conductivity, and 50.71% for Ca2+. These values represent improvements of 4.70%, 1.40%, 16.37%, and 10.36%, respectively, compared to the standalone NF process. Furthermore, CM pretreatment consistently optimized the performance of the nanofiltration system. After continuous operation, the average specific membrane flux of the CM–NF system reached 0.715, 0.67, and 0.61 under varying pollutant concentrations—increases of 10.9%, 19.6%, and 17.3% over the standalone NF system—confirming a significant improvement in permeate flux. Under continuous operation, the average degree of irreversible fouling was markedly reduced across different pollutant concentrations—decreasing from 9.2%, 17.6%, and 23.6% for the standalone NF system to 8.9%, 15.6%, and 10.9% for the CM–NF system, which clearly demonstrates the efficacy of CM pretreatment in controlling irreversible fouling. SEM observations further corroborated that CM pretreatment effectively alleviated fouling on the NF membrane surface. Additionally, higher Ca2+ concentrations were found to contribute to reduced membrane fouling and enhance flux performance.
Open AccessWater Purification Efficiency and Membrane Fouling Behavior of Ceramic Membrane-Nanofiltration in Treating Water Treatment Plant Production Wastewater
To mitigate the risks associated with production wastewater from water treatment plants, this study evaluated the effectiveness of nanofiltration (NF) and a hybrid ceramic membrane–nanofiltration (CM–NF) process in removing natural organic matter (NOM) and Ca2+. A comprehensive analysis of changes in specific flux and fouling resistance of the NF membrane, combined with scanning electron microscopy (SEM) observations, provided deeper insight into membrane fouling behavior. The results show that the CM–NF process achieved average removal rates of 95.60% for DOC, 98.55% for UV254, 34.50% for conductivity, and 50.71% for Ca2+. These values represent improvements of 4.70%, 1.40%, 16.37%, and 10.36%, respectively, compared to the standalone NF process. Furthermore, CM pretreatment consistently optimized the performance of the nanofiltration system. After continuous operation, the average specific membrane flux of the CM–NF system reached 0.715, 0.67, and 0.61 under varying pollutant concentrations—increases of 10.9%, 19.6%, and 17.3% over the standalone NF system—confirming a significant improvement in permeate flux. Under continuous operation, the average degree of irreversible fouling was markedly reduced across different pollutant concentrations—decreasing from 9.2%, 17.6%, and 23.6% for the standalone NF system to 8.9%, 15.6%, and 10.9% for the CM–NF system, which clearly demonstrates the efficacy of CM pretreatment in controlling irreversible fouling. SEM observations further corroborated that CM pretreatment effectively alleviated fouling on the NF membrane surface. Additionally, higher Ca2+ concentrations were found to contribute to reduced membrane fouling and enhance flux performance.
- Open Access
Membrane Fouling Control and Treatment Performance Using Coagulation–Tubular Ceramic Membrane with Concentrate Recycling
A comparative study was conducted to investigate membrane fouling control and treatment performance using natural surface water as the feed source. The evaluated processes included: (1) direct filtration–tubular ceramic membrane (DF-TCM, control); (2) coagulation–tubular ceramic membrane (C-TCM); and (3) coagulation–tubular ceramic membrane with concentrate recycling (C-TCM-CR). Experimental results demonstrated that under constant flux operation at 75 L/(m2·h) for 8 h, the C-TCM-CR process reduced the transmembrane pressure (TMP) increase by 83% and 35% compared to DF-TCM and C-TCM, respectively. Floc size distribution analysis and cake layer characterization revealed that the C-TCM-CR process enhanced coagulation efficiency and formed high-porosity cake layers on membrane surfaces, thereby mitigating fouling development. Notably, the coagulation-assisted processes demonstrated improved organic matter removal, with 13%, 10%, and 10% enhancement in CODMn, UV254, and medium molecular weight organics (2000–10,000 Da) removal compared to DF-TCM, along with a moderate enhancement in fluorescent substances removal efficiency. All three processes achieved over 99% turbidity removal efficiency, as the ceramic membranes demonstrate excellent filtration performance.
Open AccessMembrane Fouling Control and Treatment Performance Using Coagulation–Tubular Ceramic Membrane with Concentrate Recycling
A comparative study was conducted to investigate membrane fouling control and treatment performance using natural surface water as the feed source. The evaluated processes included: (1) direct filtration–tubular ceramic membrane (DF-TCM, control); (2) coagulation–tubular ceramic membrane (C-TCM); and (3) coagulation–tubular ceramic membrane with concentrate recycling (C-TCM-CR). Experimental results demonstrated that under constant flux operation at 75 L/(m2·h) for 8 h, the C-TCM-CR process reduced the transmembrane pressure (TMP) increase by 83% and 35% compared to DF-TCM and C-TCM, respectively. Floc size distribution analysis and cake layer characterization revealed that the C-TCM-CR process enhanced coagulation efficiency and formed high-porosity cake layers on membrane surfaces, thereby mitigating fouling development. Notably, the coagulation-assisted processes demonstrated improved organic matter removal, with 13%, 10%, and 10% enhancement in CODMn, UV254, and medium molecular weight organics (2000–10,000 Da) removal compared to DF-TCM, along with a moderate enhancement in fluorescent substances removal efficiency. All three processes achieved over 99% turbidity removal efficiency, as the ceramic membranes demonstrate excellent filtration performance.
- Top Cited Papers
- 13 May 2025
- Published by Elsevier in Journal of Environmental Management
- Vol. 386, 125787
Degradation of typical tetracycline antibiotics in landfill leachate by three-dimensional aerated electrocatalytic reactor (3D-AER): electrode properties, influencing factors and degradation mechanism
- 13 May 2025
- Published by Elsevier in Journal of Environmental Management
- Vol. 386, 125787
Top Cited PapersDegradation of typical tetracycline antibiotics in landfill leachate by three-dimensional aerated electrocatalytic reactor (3D-AER): electrode properties, influencing factors and degradation mechanism
- Open Access
- 6 March 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (10) , 7480-7488
Effects of nitrate and nitrite on the UV/PDS process: performance and byproduct formation from the perspective of substituents
NO 3 − /NO 2 − affected the removal of Ph, BA and SA in UV/PDS via substituent-driven electron density and RNS. Substituents guided reactive species' attack sites and N-byproduct formation.
- 6 March 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (10) , 7480-7488
Open AccessEffects of nitrate and nitrite on the UV/PDS process: performance and byproduct formation from the perspective of substituents
NO 3 − /NO 2 − affected the removal of Ph, BA and SA in UV/PDS via substituent-driven electron density and RNS. Substituents guided reactive species' attack sites and N-byproduct formation.
- Open Access
Fouling and Chemical Cleaning Strategies for Submerged Ultrafiltration Membrane: Synchronized Bench-Scale, Full-Scale, and Engineering Tests
This study investigated membrane fouling issues associated with the operation of a submerged ultrafiltration membrane in a drinking water treatment plant (DWTP) and optimized the associated chemical cleaning strategies. By analyzing the surface components of the membrane foulant and the compositions of the membrane cleaning solution, the primary causes of membrane fouling were identified. Membrane fouling control strategies suitable for the DWTP were evaluated through chemical cleaning tests conducted for bench-scale, full-scale, and engineering cases. The results show that the membrane foulants were primarily composed of a mixture of inorganics and organics; the inorganics were mainly composed of Al and Si, while the organics were primarily humic acid (HA). Sodium citrate proved to be the most effective cleaning agent for inorganic fouling, which was mainly composed of Al, whereas sodium hypochlorite (NaClO) combined with sodium hydroxide (NaOH) showed the best removal efficiency for organic fouling, which predominantly consisted of HA and Si. However, sodium hypochlorite (NaClO) combined with sodium hydroxide (NaOH) showed the best removal efficiency for organic fouling and Si; organic fouling predominantly consisted of HA. Based on the bench-scale test results, flux recovery was verified in the full-scale system. Under a constant pressure of 30 kPa, the combined acid–alkali cleaning achieved the best flux recovery, restoring the flux from 22.8 L/(m2·h) to 66.75 L/(m2·h). In the engineering tests, combined acid–alkali cleaning yielded results consistent with those of the full-scale tests. In the practical engineering cleaning process, adopting a cleaning strategy of alkaline (NaClO + NaOH) cleaning followed by acidic (sodium citrate) cleaning can effectively solve the membrane fouling problem.
Open AccessFouling and Chemical Cleaning Strategies for Submerged Ultrafiltration Membrane: Synchronized Bench-Scale, Full-Scale, and Engineering Tests
This study investigated membrane fouling issues associated with the operation of a submerged ultrafiltration membrane in a drinking water treatment plant (DWTP) and optimized the associated chemical cleaning strategies. By analyzing the surface components of the membrane foulant and the compositions of the membrane cleaning solution, the primary causes of membrane fouling were identified. Membrane fouling control strategies suitable for the DWTP were evaluated through chemical cleaning tests conducted for bench-scale, full-scale, and engineering cases. The results show that the membrane foulants were primarily composed of a mixture of inorganics and organics; the inorganics were mainly composed of Al and Si, while the organics were primarily humic acid (HA). Sodium citrate proved to be the most effective cleaning agent for inorganic fouling, which was mainly composed of Al, whereas sodium hypochlorite (NaClO) combined with sodium hydroxide (NaOH) showed the best removal efficiency for organic fouling, which predominantly consisted of HA and Si. However, sodium hypochlorite (NaClO) combined with sodium hydroxide (NaOH) showed the best removal efficiency for organic fouling and Si; organic fouling predominantly consisted of HA. Based on the bench-scale test results, flux recovery was verified in the full-scale system. Under a constant pressure of 30 kPa, the combined acid–alkali cleaning achieved the best flux recovery, restoring the flux from 22.8 L/(m2·h) to 66.75 L/(m2·h). In the engineering tests, combined acid–alkali cleaning yielded results consistent with those of the full-scale tests. In the practical engineering cleaning process, adopting a cleaning strategy of alkaline (NaClO + NaOH) cleaning followed by acidic (sodium citrate) cleaning can effectively solve the membrane fouling problem.