HNHannele Niiniviita

Hannele Niiniviita

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hannele Niiniviita has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Jarmo Kulmala

    Department of Medical Physics, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, 20520, Turku, Finland

    3 shared publications
  • Timo Kiljunen

    Docrates Cancer Center, Saukonpaadenranta 2, 00180, Helsinki, Finland

    3 shared publications
  • Anna K Sutela

    Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland

    1 shared publication
  • Antti Vanhanen

    Department of Oncology and Department of Medical Physics, Tampere University Hospital, Tampere, Finland

    1 shared publication
  • Arja Harila-Saari

    Department of Women's and Children's Health Uppsala University Uppsala Sweden

    1 shared publication
  • Heikki M J Rantala

    Department of Pediatrics and Adolescence, PEDEGO Research Unit and Medical Research Center, Oulu University Hospital, and University of Oulu, Oulu, Finland

    1 shared publication

Latest Publications

  • Open Access

    Radiation-induced accelerated aging of the brain vasculature in young adult survivors of childhood brain tumors

    by Tiina Maria Remes, Maria Helena Suo-Palosaari, Päivi K T Koskenkorva, Anna K Sutela, Sanna-Maria Toiviainen-Salo, Pekka M Arikoski, Mikko O Arola, Vesa-Pekka Heikkilä, Mika Kapanen, Päivi Maria Lähteenmäki, et al.

    Background: Cranial radiotherapy may damage the cerebral vasculature. The aim of this study was to understand the prevalence and risk factors of cerebrovascular disease (CVD) and white matter hyperintensities (WMHs) in childhood brain tumors (CBT) survivors treated with radiotherapy. Methods: Seventy CBT survivors who received radiotherapy were enrolled in a cross-sectional study at a median 20 years after radiotherapy cessation. The prevalence of and risk factors for CVD were investigated using MRI, MRA, and laboratory testing. Tumors, their treatment, and stroke-related data were retrieved from patients’ files. Results: Forty-four individuals (63%) had CVD at a median age of 27 years (range, 16-43 years). The prevalence rates at 20 years for CVD, small-vessel disease, and large-vessel disease were 52%, 38%, and 16%, respectively. Ischemic infarcts were diagnosed in 6 survivors, and cerebral hemorrhage in 2. Lacunar infarcts were present in 7, periventricular or deep WMHs in 34 (49%), and mineralizing microangiopathy in 21 (30%) survivors. Multiple pathologies were detected in 44% of the participants, and most lesions were located in a high-dose radiation area. Higher blood pressure was associated with CVD and a presence of WMHs. Higher cholesterol levels increased the risk of ischemic infarcts and WMHs, and lower levels of high-density lipoprotein and higher waist circumference increased the risk of lacunar infarcts. Conclusions: Treating CBTs with radiotherapy increases the risk of early CVD and WMHs in young adult survivors. These results suggest an urgent need for investigating CVD prevention in CBT patients.


  • Dose monitoring in pediatric and young adult head and cervical spine CT studies at two emergency duty departments

    by Hannele Niiniviita, Timo Kiljunen, Minna Huuskonen, Simo Teperi, Jarmo Kulmala

    As the number of pediatric computed tomography (CT) imaging is increasing, there is a need for real-time radiation dose monitoring and evaluation of the imaging protocols. The aim of this study was to present the imaging data, patient doses, and observations of pediatric and young adult trauma—and routine head CT and cervical spine CT collected by a dose monitoring software.


  • LOW-DOSE CT PROTOCOL OPTIMIZATION FOR THE ASSESSMENT OF ACUTE APPENDICITIS: THE OPTICAP PHANTOM STUDY

    by Hannele Niiniviita, Paulina Salminen, Juha M Grönroos, Irina Rinta-Kiikka, Saija Hurme, Timo Kiljunen, Jarmo Kulmala, Mika Teräs, Suvi Sippola, Johanna Virtanen

    The aim was to evaluate effects of voltage, noise input (NI) and iterative reconstruction (IR) on radiation dose and image quality in order to establish a contrast enhanced low-dose protocol for assessment of acute appendicitis. An anthropomorphic abdominal phantom mimicking contrast enhanced abdomen was scanned with 80, 100 and 120 kV, standard and strong IR and 11 NIs (66 protocols). A total of 14 test tubes of increasing iodine dilutions and one tube with an appendicolith were evaluated within the phantom. The dose, HUs, noise, contrast-to-noise ratio (CNR) and figure of merit (FOM) were determined. Visual quality scores were assessed by two readers. A clinically used voltage–IR combination (120 kV, standard IR) was used as a reference. Overall, 100 kV with standard IR (p = 0.002) and 80 kV with both IRs (p < 0.001) showed higher CNR than the reference, but noise was most pronounced at 80 kV (p < 0.001). The highest FOM was found in the 100 kV protocols (p < 0.001). The reference and 100 kV with standard IR had highest image quality scores, where the 100 kV protocol enabled a distinct dose reduction. Lowering the voltage seems to be a more favorable tool than IR changes in optimizing the dose in contrast enhanced abdominal CT. Trial registration: ClinicalTrials.gov number, NCT01022567.


  • Comparison of Effective Dose and Image Quality for Newborn Imaging on Seven Commonly Used CT Scanners

    by Hannele Niiniviita, Timo Kiljunen, Jarmo Kulmala

    This study compares the image quality and the patient doses on seven different computed tomography (CT) scanners for newborn chest imaging. The dose was measured by using an anthropomorphic newborn phantom and thermoluminescence dosemeters (TLDs). The effective dose was estimated separately based on a dose-length-product display, TLD measurements and the ImPACT CT dose calculation software. The image quality was assessed using a signal-to-noise ratio and a contrast-to-noise ratio (CNR). In order to compare the different scanners, a figure of merit (FOM) based on the rate of CNR2 and computed tomography dose index (CTDIvol) was calculated. The organ doses within the scan area ranged between 0.3 and 2.9 mGy and they depended on the organ and used scanner. The highest effective dose (1.1 mSv) was observed on Aquilion 32 and the lowest effective dose was observed on the Aquilion One (0.22 mSv). The lowest organ doses and highest FOM were observed on the Optima 660. With the Aquilion One and the Definition Dual Flash the examination was 71–90% faster when compared with other scanners. Newer devices equipped with novel dose-saving methods provide a lower dose, as well as take better advantage of the radiation in the image formation.