Aneline Dolet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aneline Dolet has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Daniele Picone
3 shared publications- Didier Voisin
Univ. Grenoble Alpes, CNRS, IRD, Grenoble INP, IGE, Grenoble
3 shared publications Mauro Dalla Mura
3 shared publicationsEtienne Le Coarer
2 shared publicationsSilvère Gousset
2 shared publications- Cédric Richard
Universit Cte dAzur, CNRS, OCA, Nice, France
1 shared publication
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
2D and 3D multispectral photoacoustic imaging - Application to the evaluation of blood oxygen concentration
Imagerie photoacoustique multispectrale 2D et 3D - Application à l'évaluation de la concentration d'oxygène dans le sang: L'imagerie photoacoustique est une modalité d'imagerie fonctionnelle basée sur la génération d'ondes acoustiques par des tissus soumis à une illumination optique (impulsion laser). L'utilisation de différentes longueurs d'ondes optiques permet la discrimination des milieux imagés. Cette modalité est prometteuse pour de nombreuses applications médicales liées, par exemple, à la croissance, au vieillissement et à l'évolution de la vascularisation des tissus. En effet, l'accès à l'oxygénation du sang dans les tissus est rendu possible par l'imagerie photoacoustique. Cela permet, entre autres applications, la discrimination de tumeurs bénignes ou malignes et la datation de la mort tissulaire (nécrose). Ce travail de thèse a pour objectif principal la construction d'une chaîne de traitement des données photoacoustiques multispectrales pour le calcul de l'oxygénation du sang dans les tissus. Les principales étapes sont, d'une part, la discrimination des données (clustering), pour extraire les zones d'intérêt, et d'autre part, la quantification des différents constituants présents dans celles-ci (unmixing). Plusieurs méthodes non supervisées de discrimination et de quantification ont été développées et leurs performances comparées sur des données photoacoustiques multispectrales expérimentales. Celles-ci ont été acquises sur la plateforme photoacoustique du laboratoire, lors de collaborations avec d'autres laboratoires et également sur un système commercial. Pour la validation des méthodes développées, de nombreux fantômes contenant différents absorbeurs optiques ont été conçus. Lors du séjour de cotutelle de thèse en Italie, des modes d'imagerie spécifiques pour l'imagerie photoacoustique 2D et 3D temps-réel ont été développés sur un échographe de recherche. Enfin, des acquisitions in vivo sur modèle animal (souris) au moyen d'un système commercial ont été réalisées pour valider ces développements.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
2D and 3D multispectral photoacoustic imaging - Application to the evaluation of blood oxygen concentration
Imagerie photoacoustique multispectrale 2D et 3D - Application à l'évaluation de la concentration d'oxygène dans le sang: L'imagerie photoacoustique est une modalité d'imagerie fonctionnelle basée sur la génération d'ondes acoustiques par des tissus soumis à une illumination optique (impulsion laser). L'utilisation de différentes longueurs d'ondes optiques permet la discrimination des milieux imagés. Cette modalité est prometteuse pour de nombreuses applications médicales liées, par exemple, à la croissance, au vieillissement et à l'évolution de la vascularisation des tissus. En effet, l'accès à l'oxygénation du sang dans les tissus est rendu possible par l'imagerie photoacoustique. Cela permet, entre autres applications, la discrimination de tumeurs bénignes ou malignes et la datation de la mort tissulaire (nécrose). Ce travail de thèse a pour objectif principal la construction d'une chaîne de traitement des données photoacoustiques multispectrales pour le calcul de l'oxygénation du sang dans les tissus. Les principales étapes sont, d'une part, la discrimination des données (clustering), pour extraire les zones d'intérêt, et d'autre part, la quantification des différents constituants présents dans celles-ci (unmixing). Plusieurs méthodes non supervisées de discrimination et de quantification ont été développées et leurs performances comparées sur des données photoacoustiques multispectrales expérimentales. Celles-ci ont été acquises sur la plateforme photoacoustique du laboratoire, lors de collaborations avec d'autres laboratoires et également sur un système commercial. Pour la validation des méthodes développées, de nombreux fantômes contenant différents absorbeurs optiques ont été conçus. Lors du séjour de cotutelle de thèse en Italie, des modes d'imagerie spécifiques pour l'imagerie photoacoustique 2D et 3D temps-réel ont été développés sur un échographe de recherche. Enfin, des acquisitions in vivo sur modèle animal (souris) au moyen d'un système commercial ont été réalisées pour valider ces développements.
- Open Access
- 27 March 2022
- Published by Copernicus GmbH
NO2 vertical column density estimation from interferograms captured by a snapshot interferometric imaging spectrometer
Nitrogen dioxide is an atmospheric gas of major impact on climate change and air quality and its monitoring through its detection and quantification is essential to control its impact on the environment and health.The detection and estimation of trace gases are limited by cost of the acquisitions devices and spectro-temporal resolution of the acquisitions. Conventional imaging systems are the result of a trade-off in terms of size, and spectral and spatial resolutions.In order to overcome these technological limitations, a new device known under the patent of Imaging Spectrometer on Chip (ImSPOC) allows for real-time acquisition and a significant spatial resolution. As its volume about the size of a matchbox, it has the potential to become a base brick for nano-satellites, drones, or ground-based measurement platforms. The ImSpoC device is based on an array of Fabry-Perot interferometers of diffrent thickness mounted over a high-sensitivity CCD imaging detector (a matrix of photodiodes). As ImSPOC performs a division of the field of view (with a matrix ofmicro lenses coupled with the interferometers), a typical acquisition consists in a matrix of sub-images which can be recombined in order to form a single hyperspectral image of the observed scene in which each pixel yields an interferogram.When ImSPCO is used as a spectrometer, a common processing involves reconstructing spectra from interferograms as an inverse problem. This operation is importatnt since the commonly used techniques, such as Differential Optical Absorption Spectroscopy (DOAS) rely on light spectra instead of interferograms.This work explores a way to adapt these techniques directly on the interferograms captured by ImSPOC is explored by relying on an optical model of the instrument. As spectra and interferograms are linked by a Fourier-like transform, the interferograms exhibit the periodicity of the incident light spectrum. In this work we propose to use an optical filter to isolate a wavelength range where the absorption cross-section of NO2 is strongly periodic and not correlated with that of other trace gases. We expect that the correlation between a difference of interferograms and the Fourier transform of the (filtered) absorption cross-section of the target gas is proportional to the difference of slant column densities of the targeted gas, here NO2. Some experimental results were obtained by processing ImSPOC acquisitions over several hours at sunrise, noon, and sunset in two configurations: zenith light (the sensor being oriented towards the zenith), and direct light (the sensor being directed towards a surface of material with high diffuse reflectance). In order to validate the results obtained by processing the ImSPOC acquisitions, data from a conventional diffraction grating based spectrometer were used, providing reference measures for the air-mass factors and allowing for a comparison with a regular DOAS method.
- 27 March 2022
- Published by Copernicus GmbH
Open AccessNO2 vertical column density estimation from interferograms captured by a snapshot interferometric imaging spectrometer
Nitrogen dioxide is an atmospheric gas of major impact on climate change and air quality and its monitoring through its detection and quantification is essential to control its impact on the environment and health.The detection and estimation of trace gases are limited by cost of the acquisitions devices and spectro-temporal resolution of the acquisitions. Conventional imaging systems are the result of a trade-off in terms of size, and spectral and spatial resolutions.In order to overcome these technological limitations, a new device known under the patent of Imaging Spectrometer on Chip (ImSPOC) allows for real-time acquisition and a significant spatial resolution. As its volume about the size of a matchbox, it has the potential to become a base brick for nano-satellites, drones, or ground-based measurement platforms. The ImSpoC device is based on an array of Fabry-Perot interferometers of diffrent thickness mounted over a high-sensitivity CCD imaging detector (a matrix of photodiodes). As ImSPOC performs a division of the field of view (with a matrix ofmicro lenses coupled with the interferometers), a typical acquisition consists in a matrix of sub-images which can be recombined in order to form a single hyperspectral image of the observed scene in which each pixel yields an interferogram.When ImSPCO is used as a spectrometer, a common processing involves reconstructing spectra from interferograms as an inverse problem. This operation is importatnt since the commonly used techniques, such as Differential Optical Absorption Spectroscopy (DOAS) rely on light spectra instead of interferograms.This work explores a way to adapt these techniques directly on the interferograms captured by ImSPOC is explored by relying on an optical model of the instrument. As spectra and interferograms are linked by a Fourier-like transform, the interferograms exhibit the periodicity of the incident light spectrum. In this work we propose to use an optical filter to isolate a wavelength range where the absorption cross-section of NO2 is strongly periodic and not correlated with that of other trace gases. We expect that the correlation between a difference of interferograms and the Fourier transform of the (filtered) absorption cross-section of the target gas is proportional to the difference of slant column densities of the targeted gas, here NO2. Some experimental results were obtained by processing ImSPOC acquisitions over several hours at sunrise, noon, and sunset in two configurations: zenith light (the sensor being oriented towards the zenith), and direct light (the sensor being directed towards a surface of material with high diffuse reflectance). In order to validate the results obtained by processing the ImSPOC acquisitions, data from a conventional diffraction grating based spectrometer were used, providing reference measures for the air-mass factors and allowing for a comparison with a regular DOAS method.
- Open Access
In Vitro and In Vivo Multispectral Photoacoustic Imaging for the Evaluation of Chromophore Concentration
Multispectral photoacoustic imaging is a powerful noninvasive medical imaging technique that provides access to functional information. In this study, a set of methods is proposed and validated, with experimental multispectral photoacoustic images used to estimate the concentration of chromophores. The unmixing techniques used in this paper consist of two steps: (1) automatic extraction of the reference spectrum of each pure chromophore; and (2) abundance calculation of each pure chromophore from the estimated reference spectra. The compared strategies bring positivity and sum-to-one constraints, from the hyperspectral remote sensing field to multispectral photoacoustic, to evaluate chromophore concentration. Particularly, the study extracts the endmembers and compares the algorithms from the hyperspectral remote sensing domain and a dedicated algorithm for segmentation of multispectral photoacoustic data to this end. First, these strategies are tested with dilution and mixing of chromophores on colored 4% agar phantom data. Then, some preliminary in vivo experiments are performed. These consist of estimations of the oxygen saturation rate (sO) in mouse tumors. This article proposes then a proof-of-concept of the interest to bring hyperspectral remote sensing algorithms to multispectral photoacoustic imaging for the estimation of chromophore concentration.Open AccessIn Vitro and In Vivo Multispectral Photoacoustic Imaging for the Evaluation of Chromophore Concentration
Multispectral photoacoustic imaging is a powerful noninvasive medical imaging technique that provides access to functional information. In this study, a set of methods is proposed and validated, with experimental multispectral photoacoustic images used to estimate the concentration of chromophores. The unmixing techniques used in this paper consist of two steps: (1) automatic extraction of the reference spectrum of each pure chromophore; and (2) abundance calculation of each pure chromophore from the estimated reference spectra. The compared strategies bring positivity and sum-to-one constraints, from the hyperspectral remote sensing field to multispectral photoacoustic, to evaluate chromophore concentration. Particularly, the study extracts the endmembers and compares the algorithms from the hyperspectral remote sensing domain and a dedicated algorithm for segmentation of multispectral photoacoustic data to this end. First, these strategies are tested with dilution and mixing of chromophores on colored 4% agar phantom data. Then, some preliminary in vivo experiments are performed. These consist of estimations of the oxygen saturation rate (sO) in mouse tumors. This article proposes then a proof-of-concept of the interest to bring hyperspectral remote sensing algorithms to multispectral photoacoustic imaging for the estimation of chromophore concentration. - Open Access
- 3 March 2021
- Published by Copernicus GmbH
Using zenith observations for evaluation of an improved interferometric imaging spectrometer
In the context of climate change, atmospheric gas monitoring is of major interest. Accurate measurements of the concentration of CO2, CH4, NO2, O3, etc. are necessary to control their emissions. Indeed, these gases have impacts on climate change as well as on people’s health.Good control of such emissions requires gas concentration measurements with high spatial, spectral and temporal resolutions. These acquisitions are mostly done with conventional dispersive hyperspectral imaging systems. However, these instruments result from a compromise between price, resolutions and size which not always allows concentration evaluation that are accurate enough. The Imaging Spectrometer On Chip (ImSPOC) device is based on a ground-breaking concept to overcome the compromise size versus performances allowing snapshot acquisition. Indeed, it is an interferometric imaging spectrometer, sized like a matches’ box, allowing acquisition of an interferogram by pixel instead of a spectrum. In this way, a snapshot acquisition with high spectral resolutions can be acquired from Nano-satellites, drones or ground. The device is composed of a matrix of Fabry-Perot interferometers of different thickness combined with a matrix of photodetectors. ImSPOC is then a competitive device for real-time acquisitions of the atmosphere. However, despite these advantages, the acquisition of interferograms requires ad hoc signal processing techniques to reconstruct the corresponding spectra used for the estimation of the gas concentration. As the interferogram acquisitions are only on a range of thicknesses, some information are missing and need to be compensated with the signal processing methods that are specially developed to provide accurate spectra allowing to evaluate the concentration of gases. The development of these algorithms is then quite challenging.To validate the most recent ImSPOC prototype in the UV-visible range and the corresponding developed methods, zenith observations were acquired with the ImSPOC device and a classical dispersive hyperspectral spectrometer. These acquisitions allow the validation of ImSPOC at two different levels: 1) the reconstructed spectra are qualitatively compared to the spectra acquired by the classical device and 2) using the Differential Optical Absorption Spectroscopy (DOAS) method on both devices spectra, the evaluated concentrations of the gases are quantitatively compared. These comparisons allow us to validate the usefulness of the ImSPOC device for the evaluation of the gas concentration using zenith observations.
- 3 March 2021
- Published by Copernicus GmbH
Open AccessUsing zenith observations for evaluation of an improved interferometric imaging spectrometer
In the context of climate change, atmospheric gas monitoring is of major interest. Accurate measurements of the concentration of CO2, CH4, NO2, O3, etc. are necessary to control their emissions. Indeed, these gases have impacts on climate change as well as on people’s health.Good control of such emissions requires gas concentration measurements with high spatial, spectral and temporal resolutions. These acquisitions are mostly done with conventional dispersive hyperspectral imaging systems. However, these instruments result from a compromise between price, resolutions and size which not always allows concentration evaluation that are accurate enough. The Imaging Spectrometer On Chip (ImSPOC) device is based on a ground-breaking concept to overcome the compromise size versus performances allowing snapshot acquisition. Indeed, it is an interferometric imaging spectrometer, sized like a matches’ box, allowing acquisition of an interferogram by pixel instead of a spectrum. In this way, a snapshot acquisition with high spectral resolutions can be acquired from Nano-satellites, drones or ground. The device is composed of a matrix of Fabry-Perot interferometers of different thickness combined with a matrix of photodetectors. ImSPOC is then a competitive device for real-time acquisitions of the atmosphere. However, despite these advantages, the acquisition of interferograms requires ad hoc signal processing techniques to reconstruct the corresponding spectra used for the estimation of the gas concentration. As the interferogram acquisitions are only on a range of thicknesses, some information are missing and need to be compensated with the signal processing methods that are specially developed to provide accurate spectra allowing to evaluate the concentration of gases. The development of these algorithms is then quite challenging.To validate the most recent ImSPOC prototype in the UV-visible range and the corresponding developed methods, zenith observations were acquired with the ImSPOC device and a classical dispersive hyperspectral spectrometer. These acquisitions allow the validation of ImSPOC at two different levels: 1) the reconstructed spectra are qualitatively compared to the spectra acquired by the classical device and 2) using the Differential Optical Absorption Spectroscopy (DOAS) method on both devices spectra, the evaluated concentrations of the gases are quantitatively compared. These comparisons allow us to validate the usefulness of the ImSPOC device for the evaluation of the gas concentration using zenith observations.
- Open Access
- 23 March 2020
- Published by Copernicus GmbH
A new snapshot interferometric imaging spectrometer: a first comparison with a classical grating spectrometer.
Atmospheric gas monitoring is of major importance for climate change and air quality. Indeed, emissions regulations and control rely on the detection and quantification of the concentration of gases such as CO2, CH4, NO2, O3, etc. Good control on emissions is key to reduce those gases impacts on climate change and people’s health.The accuracy and relevance of such measurements depend on higher spatial, spectral and temporal resolutions. To this end, conventional dispersive hyperspectral imaging systems are typically used. However, these sensors are submitted to compromises in terms of price, spectral and spatial resolutions and temporal acquisition frequency. To overcome these compromises, a new ground-breaking device is currently developed under the name Imaging Spectrometer on Chip (ImSPOC). It is based on an interferometric imaging system that allows real time acquisition with significant spatial and spectral resolutions. The device, which takes the volume of a matches’ box, could in the future be a building block for Nano-satellites, drone, or ground based measurements platforms. The particularity of this device is the snapshot acquisition of an interferometer by pixel of the imaged scene instead of a spectrum. This is obtained by using a matrix of Fabry-Perot interferometers with different thicknesses placed in front of a photodetector. ImSPOC is then of great interest for real-time acquisitions. However, the acquisition of interferometers requires signal processing developments to reconstruct the corresponding spectra. This reconstruction relies typically on the resolution of an inverse problem. Some models of the device have been proposed to this end.To validate the efficiency of this new device and to test the developed algorithms, acquisitions were conducted tracking the sun during a whole day using our device and a conventional diffraction grating based spectrometer. In this way, the reconstructed spectra from our device can be compared to the classical spectrometer ones. Particularly, the absorption peaks are compared (their central wavelengths, amplitude, etc.). To go further, the gas characterization from both devices will be compared (gas detection, evolution over time of the vertical concentration profiles, etc.). These results allow the validation of our device to this application and highlight the signal processing improvements that could be done in the future to have more accurate measurements.
- 23 March 2020
- Published by Copernicus GmbH
Open AccessA new snapshot interferometric imaging spectrometer: a first comparison with a classical grating spectrometer.
Atmospheric gas monitoring is of major importance for climate change and air quality. Indeed, emissions regulations and control rely on the detection and quantification of the concentration of gases such as CO2, CH4, NO2, O3, etc. Good control on emissions is key to reduce those gases impacts on climate change and people’s health.The accuracy and relevance of such measurements depend on higher spatial, spectral and temporal resolutions. To this end, conventional dispersive hyperspectral imaging systems are typically used. However, these sensors are submitted to compromises in terms of price, spectral and spatial resolutions and temporal acquisition frequency. To overcome these compromises, a new ground-breaking device is currently developed under the name Imaging Spectrometer on Chip (ImSPOC). It is based on an interferometric imaging system that allows real time acquisition with significant spatial and spectral resolutions. The device, which takes the volume of a matches’ box, could in the future be a building block for Nano-satellites, drone, or ground based measurements platforms. The particularity of this device is the snapshot acquisition of an interferometer by pixel of the imaged scene instead of a spectrum. This is obtained by using a matrix of Fabry-Perot interferometers with different thicknesses placed in front of a photodetector. ImSPOC is then of great interest for real-time acquisitions. However, the acquisition of interferometers requires signal processing developments to reconstruct the corresponding spectra. This reconstruction relies typically on the resolution of an inverse problem. Some models of the device have been proposed to this end.To validate the efficiency of this new device and to test the developed algorithms, acquisitions were conducted tracking the sun during a whole day using our device and a conventional diffraction grating based spectrometer. In this way, the reconstructed spectra from our device can be compared to the classical spectrometer ones. Particularly, the absorption peaks are compared (their central wavelengths, amplitude, etc.). To go further, the gas characterization from both devices will be compared (gas detection, evolution over time of the vertical concentration profiles, etc.). These results allow the validation of our device to this application and highlight the signal processing improvements that could be done in the future to have more accurate measurements.