ADAndrey Dar’enkov

Andrey Dar’enkov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrey Dar’enkov has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synchronous electric drive with adaptive speed controller and active power loop

    by Timur Emilevich Murtazin, Vladimir Georgievich Titov, Andrey Borisovich Daryenkov

    When building a ship’s electric propulsion system, increased requirements are placed on the reliability and efficiency of a rowing electric drive powered by an autonomous supply system with commensurate power. In particular, the issue of limiting and stabilizing the speed, current consumption and, consequently, the power consumption of the propeller engine under conditions of varying load torque is raised. If the control system is unable to meet these requirements, the normal operation of the diesel generator set is disrupted, up to and including shutting down, reducing fuel consumption efficiency and generator life. The best solution is to directly regulate the active power consumption and adapt the control system to changes in the load moment. There has been developed a new, different from the known, structure of the control system for a synchronous electric propeller, which includes an active power circuit and an adaptive speed controller. Based on the structure, a simulation model of a rowing synchronous electric drive has been developed in the Simulink software package of the MatLab graphical simulation environment. A simulation of the operation of a synchronous electric drive in pitching conditions with the propeller exposed, as well as starting, reversing and stopping under normal conditions was performed. A comparative analysis of a synchronous electric propeller drive with the proposed control system and with a classical control system with an external speed loop is performed. The presented simulation results confirm that the developed control system is adaptive to conditions characterized by fluctuations in the load moment during heavy rolling, and also allows you to regulate the active power consumed by the drive and limit its throws in alternating modes.

  • Open Access

    Modernization of active compensators of nonlinear distortion in the voltage of ship power station

    by Petr Vladimirovich Akhlestin, Sergey Vasilevich Popov, Oleg Stanislavovich Khvatov, Andrey Borisovich Daryenkov

    . Nonlinear consumers of electrical energy of significant capacity when operating as part of a single marine electric power system (MEPS) have a strong impact on the quality of the generated voltage, which is characterized by various electrical parameters, including the coefficient of nonlinear distortion (KND). When powered from such a network, distortion of signals from radio navigation equipment and control systems may occur, reducing efficiency of electric motors, generator equipment and electric energy consumers, deterioration of cable networks, etc. By changing active and passive methods of compensating for nonlinear voltage distortions, the influence of nonlinear electric power consumers on the voltage quality of the generated electric power at the MEPS can be reduced. One of the effective ways of compensation is the use of an active nonlinear distortion compensator, which allows you to reduce the KND to values of 4-5%. The use of a two-channel measurement and control system in an active compensator based on a voltage-boosting device is an effective way to compensate for nonlinear distortions. A new, different from the known, block diagram of the nonlinear distortion compensator is proposed, on the basis of which a simulation model of the ship's electric power system was developed in the Simulink application package of the MatLab graphical simulation environment. Simulation modeling has shown that the use of a two-channel control and measurement system makes it possible to reduce the level of nonlinear voltage distortion of the generated electricity to 2-3%, with the power of nonlinear consumers not exceeding 60% of the power source. Increasing the power of the voltage-add transformer of the active compensator under the same conditions makes it possible to reduce the coefficient of nonlinear distortion by 0.5%.

  • Open Access

    Arranging coil winding circuits of synchronous permanent-magnet machines on rotor

    by Alexander Smirnov, Andrey Dar’eNkov, Evgeny Kryukov

    Methodology of constructing coil winding electrical circuits for salient-pole stator of electrical permanent-magnet machines on the rotor is proposed, which is based on the required number of pole pairs (synchronous speed) and the number of phases. The methodology algorithm is based on determining the value of the number of stator teeth as the closest to the number of rotor poles number value, multiple of phase number, which provides a sufficient level of pitch coefficient and winding coefficient. The algorithm was tested by several examples of constructing synchronous machines winding circuits, known from electrical engineering theory and practice, including mass-produced ones. In all the examples, if the proposed methodology guidelines were formally and strictly followed, the correct circuit designs came out as a result. For high power motor pilot design, one and the same machine design variants were compared, having thirty six slots on stator, three-phase and nine-phase windings, synthesized according to the proposed algorithm for thirty two-pole rotor. Engine torque calculation with both circuit options performed by finite elements method showed the nine-phase winding developed torque advantage by 20%, due to less discretion of MMF slot distribution.

  • Open Access

    Research into a Method of Forming Neutral Point Voltage in a Three-Phase Four-Wire Voltage Inverter

    by Andrey Dar’enkov, Andrey Kurkin, Anton Sluzov, Ivan Berdnikov, Anton Khramov, Andrey Shalukho

    Three-phase four-wire voltage inverters are commonly used in energy complexes based on distributed generation sources (solar panels, wind power plants, hydrogen fuel cells) and accumulator batteries. They allow to power loads, including single-phase ones, which require neutral point connection. In these cases, phase voltage formed by spatial pulse-width modulation (PWM) methods considerably differs from sinusoidal waves and has high total harmonic distortions of voltage and current curves. This article is devoted to research into the authors’ control method of a three-phase four-wire inverter, allowing for the rectification of the form of phase voltage supplying the load when applying the most common PWM (SVPWM, DPWMMIN, DPWMMAX, GDPWM) methods. The description of the method and its research results by simulation modeling and test bench are presented in the article. The simulation modeling was carried out by the developed Simulink-model of the three-phase four-wire inverter and its control system. The modeling results showed that the method application ensures sinusoidal voltage form when applying any PWM method. At this, THDU was reduced from 21.56% to 4.39%, while THDI was reduced from 21.16% to 1.69%. Experimental tests were carried out by a test bench featuring an uninterruptible power supply source. The authors researched the inverter operation as a component of the test bench under the control of the proposed method to form neutral point voltage. The experimental test results coincided with the simulation modeling results.


  • Open Access

    Review of Efficiency Improvement Technologies of Wind Diesel Hybrid Systems for Decreasing Fuel Consumption

    by Elena Sosnina, Andrey Dar’enkov, Andrey Kurkin, Ivan Lipuzhin, Andrey Mamonov

    The article contains current information on the development of energy-efficient technologies of wind–diesel hybrid systems (WDHS) for decreasing organic fuel consumption. As a result of the review, three research directions are identified: WDHS design optimization, the main equipment and control system improvements. A comparison of their effectiveness is presented. The methods of selecting WDHS configuration, equipment capacities and location, the optimization algorithms and objective functions used are described and WDHS project feasibility calculation results are presented. The methods to improve energy efficiency of WDHS major units’ (diesel generator (DG) and wind turbine (WT)) are considered. The methods to decrease diesel fuel consumption using special devices and energy storage system are presented. Special attention is paid to WDHS operating modes’ control methods and strategies, as well as to algorithms providing the efficient system operation. As a result, recommendations for the design of both isolated and on-grid WDHS are formulated.


  • Open Access

    Research and Development of Adjustable Discontinuous Pulse Width Modulation Method for Three-Phase Voltage Source Inverter

    by Andrey Dar’enkov, Victor Sokolov, Anton Sluzov, Ivan Berdnikov, Andrey Shalukho

    Continuous pulse width modulation (CPWM) and discontinuous pulse width modulation (DPWM) strategies are used to control voltage source inverter operation. CPWM strategies allow for the reduction of total harmonic distortion values, while DPWM strategies provide a more effective reduction in inverter switching losses. The paper is devoted to the problem of improving the three-phase voltage source inverter efficiency by a controlled transition from CPWM to DPWM. The article proposes an adjustable discontinuous pulse width modulation (ADPWM) method, which means a transition from space vector PWM (refers to CPWM strategies) to DPWM in all inverter phases when the switches’ temperatures exceed the allowable value in at least one of the inverter phases. The method flowchart is presented and an algorithm for modifying the envelope curve within one sector is given. In order to test the ADPWM method a Simulink-model of a three-phase voltage source inverter and its control system were developed. A study of the proposed ADPWM method’s efficiency in comparison with CPWM, PCDPWM and NCDPWM methods was carried out using a Simulink-model. It was established that the proposed ADPWM method provides dynamic losses reduction in the inverter switches by 2.86 times compared to CPWM and by 1.89 times compared to PCDPWM and NCDPWM methods. Power supply systems for medium and high-power AC motors provide a promising area for application of the proposed ADPWM method.


  • Open Access

    Development and Operation Modes of Hydrogen Fuel Cell Generation System for Remote Consumers’ Power Supply

    by Aleksandr Kulikov, Aleksey Loskutov, Andrey Kurkin, Andrey Dar’enkov, Andrey Kozelkov, Valery Vanyaev, Andrey Shahov, Andrey Shalukho, Rustam Bedretdinov, Ivan Lipuzhin, et al.

    At the present stage of electric power industry development, special attention is being paid to the development and research of new efficient energy sources. The use of hydrogen fuel cells is promising for remote autonomous power supply systems. The authors of the paper have developed the structure and determined the optimal composition of a hybrid generation system based on hydrogen fuel cells and battery storage and have conducted studies of its operating modes and for remote consumers’ power supply efficiency. A simulation of the electromagnetic processes was carried out to check the operability of the proposed hybrid generation system structure. The simulation results confirmed the operability of the structure under consideration, the calculation of its parameters reliability and the high quality of the output voltage. The electricity cost of a hybrid generation system was estimated according to the LCOE (levelized cost of energy) indicator, its value being 1.17 USD/kWh. The factors influencing the electricity cost of a hydrogen generation system have been determined and ways for reducing its cost identified.


  • Open Access

    Economy Mode Setting Device for Wind-Diesel Power Plants

    by Andrey Dar’enkov, Elena Sosnina, Andrey Shalukho, Ivan Lipuzhin

    The article is devoted to the problem of reducing fuel consumption in a diesel generator set (DGS) as a part of a wind-diesel power plant (WDPP). The object of the research is a variable speed DGS. The goal is to develop the WDPP intelligent control system, providing an optimal shaft speed of an internal combustion engine (ICE). The basis of the intelligent control system is an economy mode setting device (EMSD), which controls the fuel supply to the ICE. The functional chart of EMSD has been presented. The main EMSD blocks contain a controller and an associative memory block. The associative memory block is a software model of an artificial neural network that determines the optimal shaft speed of the ICE. An algorithm for the WDPP intelligent control system has been developed and tested using the WDPP Simulink model. The EMSD prototype has been created, and its research has been conducted. Dependences of the change in specific and absolute fuel consumption on the load power have been obtained for two 4 kW DGS: with constant rotation speed and variable rotation speed DGS with EMSD. It has been established that the use of EMSD in the mode of low loads allow one to reduce fuel consumption by almost 30%. The error in determining the optimal engine speed using EMSD prototype is not more than 15%.