HNHadi Naderiallaf

Hadi Naderiallaf

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hadi Naderiallaf has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Comprehensive Characterization of Glass Fiber Wire: Thermal Life, Electrical Life, and Partial Discharge

    by Muhammad Raza Khowja, Hadi Naderiallaf, Kuldeep Singh, Sarang Satheesh, Gaurang Vakil, Chris Gerada

    This paper presents a comprehensive investigation of glass-fiber wire insulation, evaluating its thermal life, electrical life, partial discharge (PD) behavior and the impact of combined thermal and electrical ageing on insulation lifetime. Thermal endurance tests were conducted to establish thermal life versus temperature characteristics. The impact of thermal ageing was assessed by monitoring dissipation factor and insulation capacitance, confirming progressive degradation within the insulation. The time-to-failure of each sample was estimated and statistically analyzed using Weibull probability distribution to develop life models. The model, derived at the 50% failure percentile, was compared with manufacturer data, showing close agreement with a percentage error of only 0.44%. Subsequently, electrical ageing tests were conducted to determine electrical life versus voltage excitations. PD measurements under PWM excitation were then carried out to evaluate the impact of pulse frequency, rise time, and duty cycle on the PDIV of glass-fiber insulation. Finally, the impact of combined thermal and electrical ageing on the life of glass-fiber insulation is evaluated using Miner’s law. A combined representative thermo-electrical stress profile is suggested under which the insulation has consumed approximately 96.3% of its lifetime, corresponding to 7,704 hours out of the targeted 8,000 hours lifetime.


  • Framework for Insulation Thickness Calculation in PD-Free E-Machines for Automotive and Aerospace

    by Hadi Naderiallaf, Michele Degano, Christopher Gerada

    This article presents a framework for optimizing insulation thickness (IT) in electrical machines (EMs), ensuring reliability and efficiency for a fixed copper diameter and slot geometry. A validated, model-based software, grounded in the streamer inception criterion (SIC), calculates optimal IT for turn-to-turn windings in automotive and aerospace applications, incorporating enhancement factors (EFs) from IEC 60034-18-41. IT is evaluated for automotive systems (1000 mbar) across five temperatures ( $20~^{\circ }$ C– $180~^{\circ }$ C) and four inverter dc bus voltages (1–1.6 kV). Aerospace analysis considers three air pressures (600, 400, and 200 mbar) at altitudes of 13.8–38.6 kft, the same temperature range, and four voltage levels (0.7–1 kV). The framework is applicable to all winding topologies and evaluates IT under worst case conditions (nonimpregnated insulation) and varying partial discharge inception probabilities (PDIPs). Trends in partial discharge inception voltage (PDIV) versus IT are analyzed, with sensitivity to voltage variations examined across air pressures and temperatures. These findings support the design of reliable, high-performance insulation systems for electric transport.


  • Open Access

    Modeling Air Pressure Impact on PDIV for Rectangular Wire Turn-to-Turn Insulation of Inverter-Fed Motors Under Different Voltage Waveform Excitations

    by Hadi Naderiallaf, Michele Degano, Christopher Gerada

    This study investigates the partial discharge inception voltage (PDIV) in turn-to-turn insulation of form-wound windings in inverter-fed motors under nine different air pressures, ranging from 1013 mbar to 10 mbar. The research evaluates three voltage waveform excitations: 50 Hz AC, unipolar positive (UP), and bipolar (BP) steep-fronted square waves. The pulse width modulation (PWM) excitations are characterized by a switching frequency of 2.5 kHz, a rise time of 80 ns, and a pulse width of 100 μs. The experimental analysis focuses on peak and peak-to-peak PDIV values, comparing the variations between 50 Hz AC and PWM excitations across different air pressures. In addition, a novel predictive PDIV model is developed using Schumann’s streamer inception criterion (SCSIC) to account for air pressure variations across the three waveform excitations. As another innovation, the model examines streamer inception parameters (SIPs) in rectangular turn-to-turn insulation, incorporating factors such as critical field line length (CFLL), effective ionization coefficient (α eff ), partial discharge inception field ( E inc ), and firing voltage ( V firing ) under varying air pressures and voltage waveforms. This study provides critical insights into partial discharge phenomena and their potentially destructive effects on rectangular insulated wires. These findings are vital for insulation designers seeking to develop PD-free designs by considering the impact of air pressure, voltage waveform, and variations in SIPs.


  • Fillet Radius Impact of Rectangular Insulated Wires on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors

    by Hadi Naderiallaf, Michele Degano, Chris Gerada, David Gerada

    This contribution elucidates the impact of the fillet radius, a geometric feature of rectangular insulated wires not commonly considered, on the partial discharge inception voltage (PDIV) in low-voltage machine turn-to-turn winding insulation. Initial PDIV tests involve edgewise-insulated wire samples with a reference fillet radius. These measurements are performed under constant conditions: 30°C temperature, 35% relative humidity, and atmospheric pressure (1000 mbar). These tests are carried out under AC 50 Hz excitations, following IEC 60034-18-41 guidelines for inverter-fed motor insulation system qualification. Subsequently, a probabilistic PDIV predictive model is developed based on Schumann’s streamer inception criterion (SCSIC). This expanded model then analyses and forecasts the impact of the fillet radius on PDIV and its associated dispersion level, within the context of the 2-parameter Weibull distribution and the given environmental conditions. Furthermore, a novel method is presented to understand partial discharge (PD) phenomenology and its destructive potential in rectangular insulated wires with varying fillet radii. This approach employs SCSIC-derived streamer inception parameters (SIPs): critical field line length (CFLL), air effective ionization coefficient (α eff ), PD inception field ( E inc ), and firing voltage ( V firing ). The developed probabilistic predictive model enables the selection of an optimal fillet radius value, facilitating the creation of a reliable insulation system with maximum PDIV and minimal PD-related damage.


  • Modeling Humidity Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors at Different Temperatures

    by H. Naderiallaf, Y. Ji, P. Giangrande, M. Galea

    This paper models the partial discharge inception voltage (PDIV) as a function of ambient humidity ( H ) at various temperatures ( Ts ) using Schumann’s streamer inception criterion (SCSIC) for turn-to-turn insulation, which is the most vulnerable part in inverter-fed motors’ insulation system. The Schumann constant (i.e., the natural logarithm of the critical electron number defining the Townsend-to-streamer discharge transition, K ) varies with H , showing distinct patterns at low and high Ts . The K equations are derived across a wide range of relative humidity (RH) levels (20%, 30%, 40%, 50%, 60%, 70%, 80%, and 90%) at four Ts (25°C, 40°C, 60°C, and 90°C). These equations can be used in finite element analysis software to predict PDIV under varying H with outstanding accuracy. Additionally, a novel approach is presented for partial discharge (PD) phenomenology under H variations at different Ts using SCSIC-derived streamer inception parameters (SIPs): critical field line length (CFLL), air effective ionization coefficient (α eff ), partial discharge (PD) inception field ( E inc ) and firing voltage ( V firing ). Notably, at high Ts (e.g., 90°C), a transition phase emerges concerning RH, leading to significant SIP changes due to the disappearance of a critical region (CritR) in α eff at specific electric field intensities. The developed humidity-dependent PDIV model supports insulation designers in achieving PD-free designs that account for H variations and sheds light on SIPs variations concerning H changes.


  • Air Pressure Impact on the Avalanche Size for Turn-to-Turn Insulation of Inverter-Fed Motors

    by Hadi Naderiallaf, Yatai Ji, Paolo Giangrande, Michael Galea

    This article endeavors to illuminate the variations of various streamer inception parameters (SIPs) with respect to air pressure based on Schumann’s streamer inception criterion (SCSIC). The results based on measured partial discharge inception voltage (PDIV) values and using electric field distribution obtained via electrostatic simulations and ionization swarm parameters reveal that the Schumann constant, ${K}$ , which is the natural logarithm of the threshold number of electrons determining the transition from Townsend to streamer discharge, and consequently, the critical avalanche size ( ${N} _{\text {c}}$ ) increase with air pressure reduction. Different SIPs such as critical field line length (CFLL), effective ionization coefficient of air ( $\alpha _{\text {eff}}$ ), PD inception field ( ${E} _{\text {inc}}$ ), firing voltage ( ${V} _{\text {firing}}$ ) across the critical field line (CFL), and ${K}$ and ${N} _{\text {c}}$ are analyzed extensively as a function of air pressure. In light of the findings of this contribution, it is demonstrated that the derived ${K}$ functions as a function of air pressure can improve drastically the accuracy of PDIV prediction in particular for low air pressures rather than a single ${K}$ parameter value obtained at ground level. The study’s findings represent a guideline for electrical machine designers to improve the insulation design of electrical machines employed in the more electric aircraft (MEA) applications.


  • Temperature Impact on PDIV for Turn-to-Turn Insulation of Inverter-Fed Motors: From Ground Level to Cruising Altitude

    by Hadi Naderiallaf, Yatai Ji, Paolo Giangrande, Michael Galea

    Considering the turn-to-turn insulation as the most susceptible part to the failure of the electrical machine’s insulation system in inverter-fed motors, this paper aims to elucidate the effect of temperature ( T ) on the streamer inception parameters (SIPs), including the Schumann constant ( K ), critical field line length (CFLL), air effective ionization coefficient (α eff ), and streamer inception field ( E inc ). Particular attention is also given to extending the partial discharge inception (PDIV) modelling at cruising altitude (CA), equivalent to the air pressure of 200 mbar, as a function of T based on the Schumann streamer inception criterion (SCSIC), compared with the results obtained at 1000 mbar, i.e., ground level (GL). Furthermore, the ratios of SIPs and PDIV values at CA to those attained at GL are analysed as a function of T . The investigation findings serve as a prescription for electrical machine designers to enhance the insulating design of electrical machines used in More Electric Aircraft (MEA) applications.


  • Assessment of Edgewise Insulated Wire Bend Radius Impact on Dielectric Properties of Turn-to-Turn Insulation Through Thermal Aging

    by H. Naderiallaf, M. Degano, C. Gerada

    This study aims to evaluate the impact of the bending radius of edgewise insulated wires on dielectric properties such as partial discharge inception voltage (PDIV), partial discharge extinction voltage (PDEV), dielectric dissipation factor (DDF), and insulation capacitance (IC) through thermal aging. The tests are performed at room temperature (20 °C) and atmospheric pressure (1013 mbar) on unaged and thermally aged polytetrafluoroethylene (PTFE)-wrapped pairs of edgewise insulated wires, models of the turn-to-turn insulation. The accelerated thermal aging is carried out at 250 °C (i.e., 50 °C higher than thermal class) for two different aging periods: 156 and 312 h. To manufacture a coil, it is generally demanded to shape 90° bends out of edgewise enameled winding wires. Therefore, the obtained experimental results are helpful for the coil manufacturers, providing a clue how the bending radius can impact the dielectric properties of turn-to-turn insulation and introducing an optimum radius, which can present better insulation performance.


  • PDIV Modeling for Rectangular Wire Turn-to-Turn Insulation of Inverter Fed Motors Through Thermal Aging

    by Hadi Naderiallaf, Michele Degano, Chris Gerada

    This contribution develops the partial discharge inception voltage (PDIV)-finite-element method (FEM)-based model based on Schumann’s streamer inception criterion (SCSIC) with respect to thermal aging time (TAGT) or the insulation lifetime for the turn-to-turn insulation of coil winding made by rectangular insulated wires. The accelerated thermal aging is performed at 250 °C, which is 50 °C higher than the thermal class, with aging intervals of 156 and 312 h. PDIV measurements are conducted at a constant temperature of 25 °C, 40% relative humidity, and atmospheric pressure (1013 mbar). The measurements are done under ac 50-Hz excitations, following IEC 60034-18-41 guidelines for inverter fed motor insulation system qualification. Furthermore, this study analyzes streamer inception parameters such as critical field line length (CFLL), effective ionization coefficient ( $\alpha _{\text {eff}}{)}$ , partial discharge (PD) inception field ( ${E}_{\text {discharge}}{)}$ , firing voltage ( ${V}_{\text {firing}}{)}$ , and its correlation with PD charge amplitude as a function of TAGT or the insulation lifetime.