Liyong Yang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Liyong Yang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Shuo Liu
North China University of Technology
7 shared publications - Dixi Xin
National User‐Side Energy Storage Innovation Research and Development Center North China University of Technology Beijing 100144 China
2 shared publications - Chaonan Tong
School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China
1 shared publication - Dongkai Ma
College of Electrical and Control Engineering, North China University of Technology, Beijing 100144, China
1 shared publication Jianlin Li
Electrical and Control Engineering College, North China University of Technology, Beijing, China
1 shared publicationLi Wang
Electrical and Control Engineering College, North China University of Technology, Beijing, China
1 shared publication
Latest Publications
- Open Access
Grid Harmonics Suppression for Three Phase Dual-Frequency Grid-Connected Inverter Based on Feedforward Compensation
Using a low pulse ratio, the electromagnetic interference and switching loss of an inverter can be effectively reduced, particularly in high-power applications. However, due to variations in grid impedance, it is a challenging task to achieve stable operation of an LCL-type grid-connected inverter (GCI) using the active damping method with low pulse ratio. Thus, a novel three-phase dual-frequency GCI is presented to ensure the symmetry of the output power and the stable operation of the system address stability issues. The proposed inverter topology in this article is composed of two inverters in parallel, which are, respectively, a power inverter unit (PIU) and an auxiliary harmonic elimination unit (AHEU). To reduce the switching loss and improve the inverter efficiency, the switching frequency of the PIU is relatively low, injecting current into the grid. Moreover, the feedforward compensation method is used in AHEU. AHEU operates at high switching frequency to generate a current component that is symmetrical with the ripple com-ponent, improving the power quality, without extracting the current harmonic as the current reference. The operating principle of feedforward compensation is explained, and a proper parameter design procedure is presented in this paper. Since L filters are used for the proposed inverter, the system can operate stably where the ratio of switching frequency to fundamental frequency is low. A 10 kW laboratory prototype was built. The experimental results showed that the grid current ripple could be effectively eliminated and the THD of the grid current was 3.01%. The proposed inverter has good stability in a weak grid, and the efficiency of the proposed inverter is 95.98% at rated current, which is 0.81% higher than the traditional GCI, effectively increasing the efficiency of the system.
Open AccessGrid Harmonics Suppression for Three Phase Dual-Frequency Grid-Connected Inverter Based on Feedforward Compensation
Using a low pulse ratio, the electromagnetic interference and switching loss of an inverter can be effectively reduced, particularly in high-power applications. However, due to variations in grid impedance, it is a challenging task to achieve stable operation of an LCL-type grid-connected inverter (GCI) using the active damping method with low pulse ratio. Thus, a novel three-phase dual-frequency GCI is presented to ensure the symmetry of the output power and the stable operation of the system address stability issues. The proposed inverter topology in this article is composed of two inverters in parallel, which are, respectively, a power inverter unit (PIU) and an auxiliary harmonic elimination unit (AHEU). To reduce the switching loss and improve the inverter efficiency, the switching frequency of the PIU is relatively low, injecting current into the grid. Moreover, the feedforward compensation method is used in AHEU. AHEU operates at high switching frequency to generate a current component that is symmetrical with the ripple com-ponent, improving the power quality, without extracting the current harmonic as the current reference. The operating principle of feedforward compensation is explained, and a proper parameter design procedure is presented in this paper. Since L filters are used for the proposed inverter, the system can operate stably where the ratio of switching frequency to fundamental frequency is low. A 10 kW laboratory prototype was built. The experimental results showed that the grid current ripple could be effectively eliminated and the THD of the grid current was 3.01%. The proposed inverter has good stability in a weak grid, and the efficiency of the proposed inverter is 95.98% at rated current, which is 0.81% higher than the traditional GCI, effectively increasing the efficiency of the system.
- 10 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (11) , 12596-12607
Research on Topology and Control Method of Transformer-Free Dual-Frequency Grid-Connected Inverter
In order to suppress leakage current and improve the efficiency of the transformer-free grid-connected inverter, a novel topology and control method is proposed. The proposed inverter consists of a power inverter unit and an auxiliary converter unit, and the two units are connected by a capacitor on the dc side. The power inverter unit transmits power to the grid at a low switching frequency for reducing power losses. The auxiliary converter unit operates at a high switching frequency, and adopts a feedforward control method to eliminate the grid current switching ripples. The voltage of parasitic capacitance between the photovoltaic array and the ground is stabilized by the auxiliary converter unit with the bipolar modulation scheme, so the leakage current can be suppressed more effectively. A 1-kW prototype was built and tested, and the experimental results are finally presented to show the performance of the proposed inverter.
- 10 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (11) , 12596-12607
Research on Topology and Control Method of Transformer-Free Dual-Frequency Grid-Connected Inverter
In order to suppress leakage current and improve the efficiency of the transformer-free grid-connected inverter, a novel topology and control method is proposed. The proposed inverter consists of a power inverter unit and an auxiliary converter unit, and the two units are connected by a capacitor on the dc side. The power inverter unit transmits power to the grid at a low switching frequency for reducing power losses. The auxiliary converter unit operates at a high switching frequency, and adopts a feedforward control method to eliminate the grid current switching ripples. The voltage of parasitic capacitance between the photovoltaic array and the ground is stabilized by the auxiliary converter unit with the bipolar modulation scheme, so the leakage current can be suppressed more effectively. A 1-kW prototype was built and tested, and the experimental results are finally presented to show the performance of the proposed inverter.
- Open Access
- 30 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 198201-198213
A Hierarchical V2G/G2V Energy Management System for Electric-Drive-Reconstructed Onboard Converter
Due to the popularity of plug-in electric vehicles (PEV)and the development of converter technology, the electric-drive-reconstructed onboard converter(EDROC)is widely used in the charging system which can work in vehicle to grid(V2G) mode or grid to vehicle(G2V) mode. In this article, an EDROC for V2G/G2V energy management system is proposed. The EDROC uses permanent magnet synchronous motor as a charging inductor in V2G/G2V mode without additional equipment. Meanwhile, this article proposes a hierarchical V2G/G2V energy management system and the corresponding hierarchical control strategy with the proposed EDROC. This system can realize the energy distribution between PEVs, and avoid PEV overcharging. The proposed EDROC and control strategy are verified by simulation and experiment.
- 30 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 198201-198213
Open AccessA Hierarchical V2G/G2V Energy Management System for Electric-Drive-Reconstructed Onboard Converter
Due to the popularity of plug-in electric vehicles (PEV)and the development of converter technology, the electric-drive-reconstructed onboard converter(EDROC)is widely used in the charging system which can work in vehicle to grid(V2G) mode or grid to vehicle(G2V) mode. In this article, an EDROC for V2G/G2V energy management system is proposed. The EDROC uses permanent magnet synchronous motor as a charging inductor in V2G/G2V mode without additional equipment. Meanwhile, this article proposes a hierarchical V2G/G2V energy management system and the corresponding hierarchical control strategy with the proposed EDROC. This system can realize the energy distribution between PEVs, and avoid PEV overcharging. The proposed EDROC and control strategy are verified by simulation and experiment.
- Open Access
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 178639-178650
Control Scheme and Performance Analysis of Dual-Frequency Single-Phase Grid-Connected Inverter Interfaced With Weak and Distorted Grids
Grid impedance variation and voltage harmonics may cause instability of the grid-connected inverter system and reduce the grid current quality under weak grid. Switching losses and electromagnetic interference of inverter can be reduced by using lower switching frequency. However, it is a challenging task to achieve stable operation of LCL-type grid-connected inverter using the active damping method at the low switching frequency. In this paper, an improved control strategy is proposed for the dual-frequency inverter, which contains a power inverter and an auxiliary converter. For the proposed control strategy, the ability to suppress the influence of the grid voltage harmonics and the robustness against grid impedance variation are analyzed. In order to reduce the switching losses, the electrical energy is delivered to the power grid through the power inverter at a low switching frequency. By using the switching ripple compensation method and the grid voltage feedforward scheme, the switching current ripple caused by the power inverter and the current harmonics caused by the grid voltage harmonics can be suppressed. Since the filters used in the proposed inverter are all L type filters, the system stability is guaranteed under weak grid. The simulation and experimental results are provided to verify the effectiveness of the proposed grid-connected inverter system under weak grid.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 178639-178650
Open AccessControl Scheme and Performance Analysis of Dual-Frequency Single-Phase Grid-Connected Inverter Interfaced With Weak and Distorted Grids
Grid impedance variation and voltage harmonics may cause instability of the grid-connected inverter system and reduce the grid current quality under weak grid. Switching losses and electromagnetic interference of inverter can be reduced by using lower switching frequency. However, it is a challenging task to achieve stable operation of LCL-type grid-connected inverter using the active damping method at the low switching frequency. In this paper, an improved control strategy is proposed for the dual-frequency inverter, which contains a power inverter and an auxiliary converter. For the proposed control strategy, the ability to suppress the influence of the grid voltage harmonics and the robustness against grid impedance variation are analyzed. In order to reduce the switching losses, the electrical energy is delivered to the power grid through the power inverter at a low switching frequency. By using the switching ripple compensation method and the grid voltage feedforward scheme, the switching current ripple caused by the power inverter and the current harmonics caused by the grid voltage harmonics can be suppressed. Since the filters used in the proposed inverter are all L type filters, the system stability is guaranteed under weak grid. The simulation and experimental results are provided to verify the effectiveness of the proposed grid-connected inverter system under weak grid.
- Open Access
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 65868-65879
Analysis, Modeling and Implementation of a Switching Bi-Directional Buck-Boost Converter Based on Electric Vehicle Hybrid Energy Storage for V2G System
This paper presents a switching bi-directional buck-boost converter (SBBBC) for vehicles-togrid (V2G) system. The topology can provide an energy bi-directional flow path for energy exchange between the Li-battery/supercapacitor (SC) hybrid energy storage system (HESS) of the electric vehicle and the grid. This topology not only has buck-boost capability, but also has the function of energy management. In this paper, the state-space averaging method is used to analyze the stability of the topology in boost and buck modes. The control strategy is given according to the state of charge (SOC) of the energy storage system to ensure that the output voltage and current are stable. And the Li-battery is charged in constant current (CC) and constant voltage (CV) mode. The voltage and current controllers are designed in the frequency domain based on bode plots. Finally, the electrical feasibility of the topology, the suitability of the design controller and control strategy are verified by simulation and experiment.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 65868-65879
Open AccessAnalysis, Modeling and Implementation of a Switching Bi-Directional Buck-Boost Converter Based on Electric Vehicle Hybrid Energy Storage for V2G System
This paper presents a switching bi-directional buck-boost converter (SBBBC) for vehicles-togrid (V2G) system. The topology can provide an energy bi-directional flow path for energy exchange between the Li-battery/supercapacitor (SC) hybrid energy storage system (HESS) of the electric vehicle and the grid. This topology not only has buck-boost capability, but also has the function of energy management. In this paper, the state-space averaging method is used to analyze the stability of the topology in boost and buck modes. The control strategy is given according to the state of charge (SOC) of the energy storage system to ensure that the output voltage and current are stable. And the Li-battery is charged in constant current (CC) and constant voltage (CV) mode. The voltage and current controllers are designed in the frequency domain based on bode plots. Finally, the electrical feasibility of the topology, the suitability of the design controller and control strategy are verified by simulation and experiment.
- Open Access
- 29 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 44739-44747
A Novel Single-Phase Bidirectional Electric-Drive-Reconstructed Onboard Converter for Electric Vehicles
In this paper, an Electric-drive-reconstructed onboard converter (EDROC) based on a switching network in the DC side is proposed. The system can utilize the existing hardware of electric vehicles and does not need extra equipment. When the EDROC connects to the power grid through the power outlet at the office or home, there is not any additional equipment (filter or relay) on the AC side. Compare with traditional EDROC, the proposed novel EDROC has advantages in cost and volume. The EDROC can realize the unity power factor in the charging mode and discharges to drive the motor in the driving mode. A proof-of-concept prototype has been built to verify the charging function and driving function of the proposed EDROC.
- 29 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 44739-44747
Open AccessA Novel Single-Phase Bidirectional Electric-Drive-Reconstructed Onboard Converter for Electric Vehicles
In this paper, an Electric-drive-reconstructed onboard converter (EDROC) based on a switching network in the DC side is proposed. The system can utilize the existing hardware of electric vehicles and does not need extra equipment. When the EDROC connects to the power grid through the power outlet at the office or home, there is not any additional equipment (filter or relay) on the AC side. Compare with traditional EDROC, the proposed novel EDROC has advantages in cost and volume. The EDROC can realize the unity power factor in the charging mode and discharges to drive the motor in the driving mode. A proof-of-concept prototype has been built to verify the charging function and driving function of the proposed EDROC.
- Open Access
- 2 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 746
Research on Application of Non-Isolated Three-Port Switching Boost Converter in Photovoltaic Power Generation System
This paper presents a non-isolated three-port switching boost converter and applies it to photovoltaic systems. The topology combines the characteristics of the switching boost network. By controlling three degrees of freedom, the ports have boost, buck, and buck-boost characteristics. It expands the three-port converter (TPC) working range with the advantages of simple structure, small size, and low cost. The operating mode and power flow direction of the TPC are determined according to the state of charge (SOC) of the energy storage system. Analyses of the working state of the topology in different working modes further verify the power flow of the system and explain its control strategy to complete the smooth switching of different working modes. Finally, the correctness of the above theory and its feasibility in photovoltaic system are verified by simulation and experiment.
- 2 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 746
Open AccessResearch on Application of Non-Isolated Three-Port Switching Boost Converter in Photovoltaic Power Generation System
This paper presents a non-isolated three-port switching boost converter and applies it to photovoltaic systems. The topology combines the characteristics of the switching boost network. By controlling three degrees of freedom, the ports have boost, buck, and buck-boost characteristics. It expands the three-port converter (TPC) working range with the advantages of simple structure, small size, and low cost. The operating mode and power flow direction of the TPC are determined according to the state of charge (SOC) of the energy storage system. Analyses of the working state of the topology in different working modes further verify the power flow of the system and explain its control strategy to complete the smooth switching of different working modes. Finally, the correctness of the above theory and its feasibility in photovoltaic system are verified by simulation and experiment.