Maryam Karami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maryam Karami has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Shahram Delfani
Department of Building Mechanical Systems, Road, Housing and Urban Development Research Center, Tehran, Iran
8 shared publicationsMehran Bozorgi
School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
2 shared publicationsMostafa Esmaeili
Department of Mechanical Engineering, Faculty of Engineering, Kharazmi University, Tehran, Iran
2 shared publications- Shahram Delfani
Department of Mechanical and Electrical Installations, Road, Housing and Urban Development Research Center (BHRC), Tehran, IRAN
2 shared publications Ali Noroozi
Tarbiat Modares University
1 shared publicationAli Salehi
University of Art
1 shared publication
Latest Publications
- 6 September 2025
- Published by Springer Nature
- p. 163-215
Application of Photovoltaic-Thermal Collectors in Energy Management Systems Integrated with Hydrogen Production, Storage, and Utilization
- 6 September 2025
- Published by Springer Nature
- p. 163-215
Application of Photovoltaic-Thermal Collectors in Energy Management Systems Integrated with Hydrogen Production, Storage, and Utilization
- 24 August 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (21) , 17617-17636
Machine learning-assisted performance analysis of a series-connected photovoltaic-thermal system with nanofluid-based direct absorption solar collector
- 24 August 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (21) , 17617-17636
Machine learning-assisted performance analysis of a series-connected photovoltaic-thermal system with nanofluid-based direct absorption solar collector
- Open Access
- 5 March 2025
- Published by Wiley in Energy Science & Engineering
- Vol. 13 (4) , 1577-1594
Performance Assessment of an Interconnected Photovoltaic‐Thermal System and Solar Thermal Collector: Parametric Study and Optimization
In the present study, an interconnected photovoltaic‐thermal system and solar thermal collector with half‐tubes are presented as a new generation of solar systems to produce maximum thermal and electrical power. Performance comparison of the photovoltaic module, photovoltaic‐thermal system, solar thermal collector, and proposed system shows that the maximum power of 1336.27 W is generated by the proposed system. Also, the outlet fluid temperature increases by 28.03% and 20.88% compared to the photovoltaic‐thermal systems and solar thermal collectors, respectively, which indicates higher quality of the generated thermal power. To improve the system performance, fins with different heights are used inside the half‐tubes. The results indicated that the overall generated power increases using the fin by up to 2.93%. A parametric analysis using response surface method showed that among four parameters including flow rate, incident solar radiation, wind speed, and ambient temperature, the solar radiation and ambient temperature have the most and least impact on the system output, respectively. Also, using the response surface method, two models are provided to predict the electrical and thermal power generation of the system. Single‐objective and multi‐objective optimization of the system is also investigated using these models.
- 5 March 2025
- Published by Wiley in Energy Science & Engineering
- Vol. 13 (4) , 1577-1594
Open AccessPerformance Assessment of an Interconnected Photovoltaic‐Thermal System and Solar Thermal Collector: Parametric Study and Optimization
In the present study, an interconnected photovoltaic‐thermal system and solar thermal collector with half‐tubes are presented as a new generation of solar systems to produce maximum thermal and electrical power. Performance comparison of the photovoltaic module, photovoltaic‐thermal system, solar thermal collector, and proposed system shows that the maximum power of 1336.27 W is generated by the proposed system. Also, the outlet fluid temperature increases by 28.03% and 20.88% compared to the photovoltaic‐thermal systems and solar thermal collectors, respectively, which indicates higher quality of the generated thermal power. To improve the system performance, fins with different heights are used inside the half‐tubes. The results indicated that the overall generated power increases using the fin by up to 2.93%. A parametric analysis using response surface method showed that among four parameters including flow rate, incident solar radiation, wind speed, and ambient temperature, the solar radiation and ambient temperature have the most and least impact on the system output, respectively. Also, using the response surface method, two models are provided to predict the electrical and thermal power generation of the system. Single‐objective and multi‐objective optimization of the system is also investigated using these models.
- Open Access
- 1 April 2024
- Published by Wiley in Energy Science & Engineering
- Vol. 12 (5) , 2297-2318
CFD modeling of a triple‐walled direct absorption evacuated tube solar collector based on hybrid nanofluid/microencapsulated PCM
Nowadays, direct absorption solar collectors are a new concept of solar collectors which have attracted special attention. The type of heat transfer fluid (HTF) has a significant influence on the efficiency of this kind of collector. Therefore, in this study, a wide range of working fluids including mono nanofluid ( and CuO), binary nanofluid, and especially the incorporation of a new hybrid combination of nanofluid and microencapsulated phase change material (MPCM), are used as the working fluids of a triple‐walled direct absorption evacuated tube solar collector. The computational fluid dynamics (CFD) method is used for simulating the collector and investigating the effect of different parameters including volume fraction, base fluid, mass flow rate, and type of absorber tube structure (double‐ and triple‐walled) on collector thermal performance. Results show that binary nanofluids of 0.06% /0.002% CuO/water and 0.06% /0.002% CuO/ethylene glycol (EG) have the largest working fluid temperature differentials equal to 48.31 and 66.5 K, respectively. It was inferred that, at the mass flow rate of 2.7 , the efficiency is obtained to be 60.29% employing binary/EG nanofluid, which is 8.68% and 15.31% higher than CuO/EG and /EG nanofluids, respectively. Inserting the hybrid CuO nanofluid/MPCM leads to an improvement of 1.14% and 1.22% in the efficiency of triple‐ and double‐walled collectors, respectively, with respect to the individual usage of the nanofluid. The thermal efficiency of the double‐walled structure is higher than triple‐walled considering all HTFs.
- 1 April 2024
- Published by Wiley in Energy Science & Engineering
- Vol. 12 (5) , 2297-2318
Open AccessCFD modeling of a triple‐walled direct absorption evacuated tube solar collector based on hybrid nanofluid/microencapsulated PCM
Nowadays, direct absorption solar collectors are a new concept of solar collectors which have attracted special attention. The type of heat transfer fluid (HTF) has a significant influence on the efficiency of this kind of collector. Therefore, in this study, a wide range of working fluids including mono nanofluid ( and CuO), binary nanofluid, and especially the incorporation of a new hybrid combination of nanofluid and microencapsulated phase change material (MPCM), are used as the working fluids of a triple‐walled direct absorption evacuated tube solar collector. The computational fluid dynamics (CFD) method is used for simulating the collector and investigating the effect of different parameters including volume fraction, base fluid, mass flow rate, and type of absorber tube structure (double‐ and triple‐walled) on collector thermal performance. Results show that binary nanofluids of 0.06% /0.002% CuO/water and 0.06% /0.002% CuO/ethylene glycol (EG) have the largest working fluid temperature differentials equal to 48.31 and 66.5 K, respectively. It was inferred that, at the mass flow rate of 2.7 , the efficiency is obtained to be 60.29% employing binary/EG nanofluid, which is 8.68% and 15.31% higher than CuO/EG and /EG nanofluids, respectively. Inserting the hybrid CuO nanofluid/MPCM leads to an improvement of 1.14% and 1.22% in the efficiency of triple‐ and double‐walled collectors, respectively, with respect to the individual usage of the nanofluid. The thermal efficiency of the double‐walled structure is higher than triple‐walled considering all HTFs.
- Open Access
- 20 March 2024
- Published by Istanbul Gedik University in International Journal of New Findings in Engineering, Science and Technology
- Vol. 2 (1) , 64-73
Dynamic simulation of the performance of a solar assisted heat pump in different climates
One method to reduce energy consumption in buildings is using solar assisted heat pumps, in which the combination of heat pump and solar collector is used to improve the thermal performance. In this paper, TRNSYS and EES software are used to simulate the performance of an indirect expansion solar assisted heat pump. Dynamic simulation of the system is performed by changing parameters such as mass flow rate of collector working fluid and the collector area in five climates including Hot/Dry, Cold/Dry, Moderate/Humid, Hot/semi-Humid, and Hot/Humid. The results show that, in January, the Cold/Dry climate had the lowest free energy ratio (FER) because of high space heating load. In this month, Hot/semi-Humid climate has the highest FER, because of the higher solar radiation and no need to space heating. The annual FER in Hot/Dry zone is 71% which is higher than that other zones. The lowest FER related to Moderate/Humid climate due to high humidity and cloudiness.
- 20 March 2024
- Published by Istanbul Gedik University in International Journal of New Findings in Engineering, Science and Technology
- Vol. 2 (1) , 64-73
Open AccessDynamic simulation of the performance of a solar assisted heat pump in different climates
One method to reduce energy consumption in buildings is using solar assisted heat pumps, in which the combination of heat pump and solar collector is used to improve the thermal performance. In this paper, TRNSYS and EES software are used to simulate the performance of an indirect expansion solar assisted heat pump. Dynamic simulation of the system is performed by changing parameters such as mass flow rate of collector working fluid and the collector area in five climates including Hot/Dry, Cold/Dry, Moderate/Humid, Hot/semi-Humid, and Hot/Humid. The results show that, in January, the Cold/Dry climate had the lowest free energy ratio (FER) because of high space heating load. In this month, Hot/semi-Humid climate has the highest FER, because of the higher solar radiation and no need to space heating. The annual FER in Hot/Dry zone is 71% which is higher than that other zones. The lowest FER related to Moderate/Humid climate due to high humidity and cloudiness.
- 3 September 2023
- Published by Taylor & Francis in Advances in Building Energy Research
- Vol. 17 (5) , 536-553
Experimental investigation of buoyancy-driven natural ventilation in a building with an atrium using particle image velocimetry (PIV) method
- 3 September 2023
- Published by Taylor & Francis in Advances in Building Energy Research
- Vol. 17 (5) , 536-553
Experimental investigation of buoyancy-driven natural ventilation in a building with an atrium using particle image velocimetry (PIV) method
- Open Access
- 1 June 2022
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
- Vol. 29 (3) , 1288-1300
Improving thermal performance of a solar thermal/desalination combisystem using nano fluid-based direct absorption solar collector
Depletion of freshwater resources and reduction of rainfall in arid areas causes water scarcity, which is intensified by population and urbanization growth. In this study, a small-scale solar thermal/desalination combisystem using nanofluid-based direct absorption solar collectors and humidification-dehumidification desalination unit is proposed to supply domestic hot water, space heating, and freshwater demands of a residential building. The dynamic simulation of the system performance in the Hot-Dry climate zone is done using TRNSYS-MATLAB co-simulator. The results indicate that using the proposed combisystem reduces 94.3% and 17% of annual energy consumption for providing domestic hot water and space heating demands, respectively. The freshwater demand is supplied in the range of 11.3% to 100%. In the case of using a flat plate solar collector, the solar fraction for domestic hot water and space heating demands in comparison with nanofluid-based direct absorption solar collectors reduces by 3.7% and 1.7%, respectively. Furthermore, the produced freshwater reduces 18% on average. The payback time using nanofluid-based direct absorption and flat plate solar collectors are 6.4 and 7.8 years, respectively.
- 1 June 2022
- Published by SCI AND TECH UNIVERSAL INC in Scientia Iranica
- Vol. 29 (3) , 1288-1300
Open AccessImproving thermal performance of a solar thermal/desalination combisystem using nano fluid-based direct absorption solar collector
Depletion of freshwater resources and reduction of rainfall in arid areas causes water scarcity, which is intensified by population and urbanization growth. In this study, a small-scale solar thermal/desalination combisystem using nanofluid-based direct absorption solar collectors and humidification-dehumidification desalination unit is proposed to supply domestic hot water, space heating, and freshwater demands of a residential building. The dynamic simulation of the system performance in the Hot-Dry climate zone is done using TRNSYS-MATLAB co-simulator. The results indicate that using the proposed combisystem reduces 94.3% and 17% of annual energy consumption for providing domestic hot water and space heating demands, respectively. The freshwater demand is supplied in the range of 11.3% to 100%. In the case of using a flat plate solar collector, the solar fraction for domestic hot water and space heating demands in comparison with nanofluid-based direct absorption solar collectors reduces by 3.7% and 1.7%, respectively. Furthermore, the produced freshwater reduces 18% on average. The payback time using nanofluid-based direct absorption and flat plate solar collectors are 6.4 and 7.8 years, respectively.
- 11 March 2022
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 8 (2) , 249-267
Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones
Thermal insulation is one of the most effective methods of reducing energy consumption in buildings. Therefore, the parameters influencing the optimum insulation thickness are widely investigated. In this study, the optimum insulation thickness is obtained using the life cycle analysis method and the genetic algorithm by considering the size of the heating and cooling systems as an optimization variable, which has not been addressed in the earlier researches. Furthermore, the effect of the climate conditions on the optimum insulation thickness is comprehensively studied using five different climate zones, including Hot-Dry, Cold-Dry, Moderate-Humid, Hot-semi Humid, and Hot-Humid. It is found that the optimum thickness of expanded polystyrene insulation increases between 5%-19% considering the size variation of the heating systems including the central heating system and wall-hung gas boilers. By size variation of the cooling systems including the evaporative cooler and split air conditioner, this increase is between 8-19%. This is because the cost reduction due to the reduction of the required size of the heating and cooling systems can be expended for insulating the building with larger thickness which results in lower energy consumption. Based on the obtained results, the energy cost saving increases between 3.5%-14.5% and also, the payback period decreases about 1 to 3 months, depending on the considered heating and cooling systems and climate zone. The results confirm that the optimum insulation thickness can be determined with significant inaccuracy, ignoring the size variation of the heating and cooling systems as a result of thermal insulation.
- 11 March 2022
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 8 (2) , 249-267
Effect of HVAC system size on the optimum insulation thickness of the buildings in different climate zones
Thermal insulation is one of the most effective methods of reducing energy consumption in buildings. Therefore, the parameters influencing the optimum insulation thickness are widely investigated. In this study, the optimum insulation thickness is obtained using the life cycle analysis method and the genetic algorithm by considering the size of the heating and cooling systems as an optimization variable, which has not been addressed in the earlier researches. Furthermore, the effect of the climate conditions on the optimum insulation thickness is comprehensively studied using five different climate zones, including Hot-Dry, Cold-Dry, Moderate-Humid, Hot-semi Humid, and Hot-Humid. It is found that the optimum thickness of expanded polystyrene insulation increases between 5%-19% considering the size variation of the heating systems including the central heating system and wall-hung gas boilers. By size variation of the cooling systems including the evaporative cooler and split air conditioner, this increase is between 8-19%. This is because the cost reduction due to the reduction of the required size of the heating and cooling systems can be expended for insulating the building with larger thickness which results in lower energy consumption. Based on the obtained results, the energy cost saving increases between 3.5%-14.5% and also, the payback period decreases about 1 to 3 months, depending on the considered heating and cooling systems and climate zone. The results confirm that the optimum insulation thickness can be determined with significant inaccuracy, ignoring the size variation of the heating and cooling systems as a result of thermal insulation.
- Open Access
- 17 January 2022
- Published by Wiley in Energy Science & Engineering
- Vol. 10 (3) , 918-931
Heat transfer and pressure drop through mono and hybrid nanofluid‐based photovoltaic‐thermal systems
Using nanofluids in photovoltaic‐thermal systems enhances the overall efficiency; however, increasing the pressure drop and pumping power, because of the higher viscosity of nanofluids, is a challenging factor for the nanofluid‐based systems. In the present study, the thermohydraulic performance of the photovoltaic‐thermal system is compared using two water‐based nanofluids including hybrid Ag‐MgO and carbon nanotubes (CNT) nanofluids, as the working fluids. The effect of type and flow rate of the working fluid, nanoparticle concentration, and channel height on the friction factor and Nusselt number is studied using the numerical model. The model is validated using the experimental and numerical results and found that the relative errors of the results are less than 3.8% and 5.2%, respectively, which confirmed the model accuracy. The results showed that at a flow rate of 8 L/h, the volume fraction of 2%, and channel height of 10 mm, the system electrical efficiency, thermal efficiency, and friction factor using CNT nanofluid are, respectively, 0.04%, 1.31%, and 62% higher than those using base fluid and 0.03%, 0.89%, and 53% higher than those using Ag‐MgO nanofluid. It is also found that although increasing the nanoparticle concentration and decreasing the channel height improves the system efficiency, it increases the friction factor and pressure drop. Comparing the results using the mono and hybrid nanofluids showed that the thermal performance of the photovoltaic‐thermal system using CNT nanofluid is slightly better; however, the hydraulic system performance using hybrid Ag‐MgO nanofluid is improved.
- 17 January 2022
- Published by Wiley in Energy Science & Engineering
- Vol. 10 (3) , 918-931
Open AccessHeat transfer and pressure drop through mono and hybrid nanofluid‐based photovoltaic‐thermal systems
Using nanofluids in photovoltaic‐thermal systems enhances the overall efficiency; however, increasing the pressure drop and pumping power, because of the higher viscosity of nanofluids, is a challenging factor for the nanofluid‐based systems. In the present study, the thermohydraulic performance of the photovoltaic‐thermal system is compared using two water‐based nanofluids including hybrid Ag‐MgO and carbon nanotubes (CNT) nanofluids, as the working fluids. The effect of type and flow rate of the working fluid, nanoparticle concentration, and channel height on the friction factor and Nusselt number is studied using the numerical model. The model is validated using the experimental and numerical results and found that the relative errors of the results are less than 3.8% and 5.2%, respectively, which confirmed the model accuracy. The results showed that at a flow rate of 8 L/h, the volume fraction of 2%, and channel height of 10 mm, the system electrical efficiency, thermal efficiency, and friction factor using CNT nanofluid are, respectively, 0.04%, 1.31%, and 62% higher than those using base fluid and 0.03%, 0.89%, and 53% higher than those using Ag‐MgO nanofluid. It is also found that although increasing the nanoparticle concentration and decreasing the channel height improves the system efficiency, it increases the friction factor and pressure drop. Comparing the results using the mono and hybrid nanofluids showed that the thermal performance of the photovoltaic‐thermal system using CNT nanofluid is slightly better; however, the hydraulic system performance using hybrid Ag‐MgO nanofluid is improved.
- Open Access
- 12 January 2022
- Published by Wiley in Energy Science & Engineering
- Vol. 10 (3) , 707-725
Dynamic simulation of a solar ejector‐based trigeneration system using TRNSYS‐EES co‐simulator
In this paper, a new configuration of a solar combined cooling, heating, and power (CCHP) system is proposed to recover the waste thermal energy of a steam power plant, which provides the cooling and heating needs of an apartment complex located in Tehran. The required energy of the system is supplied by the parabolic trough solar collectors (PTCs) and, if necessary, an auxiliary heater is also used. An ejector refrigeration cycle (ERC) and a steam Rankine cycle are used for cooling and power generation, respectively. The cycle is dynamically modeled over a year using a TRNSYS‐EES co‐simulator. It is found that the highest Rankine cycle efficiency is obtained in the cold months (January) because of the decrease of turbine backpressure. With increasing the turbine inlet temperature from 190 to 210°C, the Rankine cycle and the overall cycle efficiencies increased about 1% and 2%, respectively. The maximum cooling, heating, and power generation, as well as the maximum solar fraction, are obtained at the turbine inlet temperatures of 210°C, which are 185.46, 598.65, 680.49 kW, and 70%, respectively. The annual overall performance and the solar fraction of the proposed CCHP system are 32.5% and 9.5%, respectively, based on 3000 m2 collector aperture area. The exergy analysis indicated that the maximum annual exergy destruction is related to the solar collectors, which have comprised 27% of the total exergy destruction. In addition, the yearly exergy efficiency of the proposed system is 39.9%.
- 12 January 2022
- Published by Wiley in Energy Science & Engineering
- Vol. 10 (3) , 707-725
Open AccessDynamic simulation of a solar ejector‐based trigeneration system using TRNSYS‐EES co‐simulator
In this paper, a new configuration of a solar combined cooling, heating, and power (CCHP) system is proposed to recover the waste thermal energy of a steam power plant, which provides the cooling and heating needs of an apartment complex located in Tehran. The required energy of the system is supplied by the parabolic trough solar collectors (PTCs) and, if necessary, an auxiliary heater is also used. An ejector refrigeration cycle (ERC) and a steam Rankine cycle are used for cooling and power generation, respectively. The cycle is dynamically modeled over a year using a TRNSYS‐EES co‐simulator. It is found that the highest Rankine cycle efficiency is obtained in the cold months (January) because of the decrease of turbine backpressure. With increasing the turbine inlet temperature from 190 to 210°C, the Rankine cycle and the overall cycle efficiencies increased about 1% and 2%, respectively. The maximum cooling, heating, and power generation, as well as the maximum solar fraction, are obtained at the turbine inlet temperatures of 210°C, which are 185.46, 598.65, 680.49 kW, and 70%, respectively. The annual overall performance and the solar fraction of the proposed CCHP system are 32.5% and 9.5%, respectively, based on 3000 m2 collector aperture area. The exergy analysis indicated that the maximum annual exergy destruction is related to the solar collectors, which have comprised 27% of the total exergy destruction. In addition, the yearly exergy efficiency of the proposed system is 39.9%.