Byoungchull Oh
Byoungchull Oh has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Beungyong Park
Department of Building and System Engineering, Hanbat National University, Daejeon 34158, Republic of Korea
5 shared publications - Suh-Hyun Kwon
Division of Architecture, Mokwon University, Daejeon 35349, Republic of Korea
3 shared publications - JuHee Jeong
Center for Regional Development, Chonnam National University
2 shared publications Cheolho Hwang
1 shared publicationDooyong Park
Senior Researcher, Energy Division, Korea Conformity Laboratories
1 shared publication- Jinkyun Cho
Hanbat National University
1 shared publication
Latest Publications
- Open Access
- 29 August 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (17) , 7790
Socio-Spatial Disparities in Heatwave Risk Perception and Cooling Shelter Utilization in Gwangju, South Korea
Heatwaves are increasing in frequency and intensity owing to climate change, posing severe health risks to urban populations, particularly vulnerable groups. This study investigates public perceptions, adaptive behavior, and policy awareness regarding extreme heat in Gwangju Metropolitan City, South Korea, a heat-prone urban area. Using a mixed-methods approach, we analyzed primary survey data from 814 residents and secondary data from the 2020 Gwangju Citizen Heatwave Awareness Survey. Statistical analyses, including chi-squared and t-tests, examined differences across socioeconomic age groups. Results indicate that while general awareness of heatwave risks is high, low-income residents exhibit lower perceived severity, limited access to mechanical cooling, and greater reliance on passive avoidance behaviors. Awareness and use of municipal cooling shelters were low, with satisfaction hindered by concerns over accessibility, cleanliness, and operational hours. Television and emergency text alerts were the main information channels; however, trust and perceived usefulness were limited. Policy recommendations include spatially targeted shelter placement informed by vulnerability mapping, improved operational standards, diversified risk communication, and enhanced community engagement. This study underscores the importance of equity-driven adaptation strategies and provides practical insights for global municipalities facing similar climate-related heat risks.
- 29 August 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (17) , 7790
Open AccessSocio-Spatial Disparities in Heatwave Risk Perception and Cooling Shelter Utilization in Gwangju, South Korea
Heatwaves are increasing in frequency and intensity owing to climate change, posing severe health risks to urban populations, particularly vulnerable groups. This study investigates public perceptions, adaptive behavior, and policy awareness regarding extreme heat in Gwangju Metropolitan City, South Korea, a heat-prone urban area. Using a mixed-methods approach, we analyzed primary survey data from 814 residents and secondary data from the 2020 Gwangju Citizen Heatwave Awareness Survey. Statistical analyses, including chi-squared and t-tests, examined differences across socioeconomic age groups. Results indicate that while general awareness of heatwave risks is high, low-income residents exhibit lower perceived severity, limited access to mechanical cooling, and greater reliance on passive avoidance behaviors. Awareness and use of municipal cooling shelters were low, with satisfaction hindered by concerns over accessibility, cleanliness, and operational hours. Television and emergency text alerts were the main information channels; however, trust and perceived usefulness were limited. Policy recommendations include spatially targeted shelter placement informed by vulnerability mapping, improved operational standards, diversified risk communication, and enhanced community engagement. This study underscores the importance of equity-driven adaptation strategies and provides practical insights for global municipalities facing similar climate-related heat risks.
- Open Access
Impact of High-Efficiency Filter Pressure Drop on the Energy Performance of Residential Energy Recovery Ventilators
As the importance of both indoor air quality (IAQ) and energy efficiency grows in residential buildings, the application of air filters in energy recovery ventilators has become essential. However, high-efficiency filters such as MERV 12 inevitably increase the pressure drop, adversely affecting the airflow, fan energy use, and heat exchange balance. This study quantitatively investigates how different levels of filter resistance—from clean conditions to 200% dust loading—affect system airflow, static pressure, exhaust air transfer, and power consumption. A standardized dust loading procedure was adopted to simulate long-term use conditions. The results show a 37% reduction in net supply airflow under heavily clogged filters, while the unit exhaust air transfer ratio increased from 7.2% to 17.7%, exceeding compliance limits. Surprisingly, electrical energy consumption decreased as the fan load dropped with the airflow. Despite an increase in the apparent heat exchange efficiency, this gain was driven by return air recirculation rather than true thermal effectiveness. These findings highlight the need for filter performance-based ERV certification and operational strategies that balance IAQ, energy use, and system compliance.
Open AccessImpact of High-Efficiency Filter Pressure Drop on the Energy Performance of Residential Energy Recovery Ventilators
As the importance of both indoor air quality (IAQ) and energy efficiency grows in residential buildings, the application of air filters in energy recovery ventilators has become essential. However, high-efficiency filters such as MERV 12 inevitably increase the pressure drop, adversely affecting the airflow, fan energy use, and heat exchange balance. This study quantitatively investigates how different levels of filter resistance—from clean conditions to 200% dust loading—affect system airflow, static pressure, exhaust air transfer, and power consumption. A standardized dust loading procedure was adopted to simulate long-term use conditions. The results show a 37% reduction in net supply airflow under heavily clogged filters, while the unit exhaust air transfer ratio increased from 7.2% to 17.7%, exceeding compliance limits. Surprisingly, electrical energy consumption decreased as the fan load dropped with the airflow. Despite an increase in the apparent heat exchange efficiency, this gain was driven by return air recirculation rather than true thermal effectiveness. These findings highlight the need for filter performance-based ERV certification and operational strategies that balance IAQ, energy use, and system compliance.
- Open Access
- 5 July 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (13) , 5745
CFD Analysis of the Impact of Building Layout and Morphology on Pedestrian-Level Airflow and Pollutant Stagnation in Urban Areas with Well-Developed Surface Boundary Layers
This study focuses on the features of wind flow and pollutant diffusion of continuous urban street canyons with distinct surface boundary layers through computational fluid dynamics (CFD) analysis. The CFD analysis is set as cyclic boundary conditions to represent the continuous canyons. This study establishes four cases with different building heights and arrangements, and three cases with different atmospheric stability conditions to evaluate the effects of building types and atmospheric stability on wind flow and ventilation characteristics. Pollutants were emitted in a section below the height of 7.5 m from the ground to figure out the ventilation performance of spaces where pedestrians move within urban street canyons. Ventilation rate and purging flow rate (PFR) were calculated to confirm the results. Furthermore, this study analyzed the effects of the ventilation efficiency of canyons on ventilation performance depending on canyon patterns and diverse conditions of atmospheric stability.
- 5 July 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (13) , 5745
Open AccessCFD Analysis of the Impact of Building Layout and Morphology on Pedestrian-Level Airflow and Pollutant Stagnation in Urban Areas with Well-Developed Surface Boundary Layers
This study focuses on the features of wind flow and pollutant diffusion of continuous urban street canyons with distinct surface boundary layers through computational fluid dynamics (CFD) analysis. The CFD analysis is set as cyclic boundary conditions to represent the continuous canyons. This study establishes four cases with different building heights and arrangements, and three cases with different atmospheric stability conditions to evaluate the effects of building types and atmospheric stability on wind flow and ventilation characteristics. Pollutants were emitted in a section below the height of 7.5 m from the ground to figure out the ventilation performance of spaces where pedestrians move within urban street canyons. Ventilation rate and purging flow rate (PFR) were calculated to confirm the results. Furthermore, this study analyzed the effects of the ventilation efficiency of canyons on ventilation performance depending on canyon patterns and diverse conditions of atmospheric stability.
- Open Access
Standby Power Reduction of Home Appliance by the i-HEMS System Using Supervised Learning Techniques
Electricity consumption in homes is on the rise due to the increasing prevalence of home appliances and longer hours spent indoors. Home energy management systems (HEMSs) are emerging as a solution to reduce electricity consumption and efficiently manage power usage at home. In the past, numerous studies have been conducted on the management of electricity production and consumption through solar power. However, there are limited human-centered studies focusing on the user’s lifestyle. In this study, we propose an Intelligent Home Energy Management System (i-HEMS) and evaluate its energy-saving effectiveness through a demonstration in a standard house in Korea. The system utilizes an IoT environment, PID sensing, and behavioral pattern algorithms. We developed algorithms based on power usage monitoring data of home appliances and human body detection. These algorithms are used as the primary scheduling algorithm and a secondary algorithm for backup purposes. We explored the deep connection between power usage, environmental sensor data, and input schedule data based on Long Short-Term Memory network (LSTM) and developed an occupancy prediction algorithm. We analyzed the use of common home appliances (TV, computer, water purifier, microwave, washing machine, etc.) in a standard house and the power consumption reduction by the i-HEMS system. Through a total of six days of empirical experiments, before implementing i-HEMS, home appliances consumed 13,062 Wh. With i-HEMS, the total consumption was reduced to 10,434 Wh (a 20% reduction), with 9060 Wh attributed to home appliances and 1374 Wh to i-HEMS operation.
Open AccessStandby Power Reduction of Home Appliance by the i-HEMS System Using Supervised Learning Techniques
Electricity consumption in homes is on the rise due to the increasing prevalence of home appliances and longer hours spent indoors. Home energy management systems (HEMSs) are emerging as a solution to reduce electricity consumption and efficiently manage power usage at home. In the past, numerous studies have been conducted on the management of electricity production and consumption through solar power. However, there are limited human-centered studies focusing on the user’s lifestyle. In this study, we propose an Intelligent Home Energy Management System (i-HEMS) and evaluate its energy-saving effectiveness through a demonstration in a standard house in Korea. The system utilizes an IoT environment, PID sensing, and behavioral pattern algorithms. We developed algorithms based on power usage monitoring data of home appliances and human body detection. These algorithms are used as the primary scheduling algorithm and a secondary algorithm for backup purposes. We explored the deep connection between power usage, environmental sensor data, and input schedule data based on Long Short-Term Memory network (LSTM) and developed an occupancy prediction algorithm. We analyzed the use of common home appliances (TV, computer, water purifier, microwave, washing machine, etc.) in a standard house and the power consumption reduction by the i-HEMS system. Through a total of six days of empirical experiments, before implementing i-HEMS, home appliances consumed 13,062 Wh. With i-HEMS, the total consumption was reduced to 10,434 Wh (a 20% reduction), with 9060 Wh attributed to home appliances and 1374 Wh to i-HEMS operation.
- 30 April 2023
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 14 (2) , 171-179
Assessing the Effects of Heat Wave Mitigation Technology on Outdoor Thermal Comfort : Empirical Experiment to Verify the Effect of Cooling Fog
To provide Social Overhead Capital (SOC) for daily human lives, local governments are preparing various measures against heat waves, such as supplying Heat Wave Mitigation Facilities and supporting the vulnerable. Cooling Fog is a recent trend of Heat Wave Mitigation Facilities, but South Korea has limited data on reducing body temperature through direct application of cooling matter on the body, and most research on Cooling Fog has addressed technical aspects. In this study, to confirm the effect of Cooling Fog on the human body, experiments were conducted. First, the change of environmental factors in the space around the Cooling Fog was compared with an unaffected area. Second, a survey was conducted targeting people who use Cooling Fog to review its sensory effects. Finally, the effect of Cooling Fog was quantitatively verified by linking and analyzing related data. The air temperature and radiation temperature were lower in the area of Cooling Fog, but humidity was high. The sensory survey confirmed that Cooling Fog produced a sensation of cooler temperature compared to the area without Cooling Fog, as assessed using Thermal Sensation Vote (TSV), Heat Score, and Apparent Temperature (AT). In addition, the area of Cooling Fog was reported to have higher Thermal Comfort than the area without.
- 30 April 2023
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 14 (2) , 171-179
Assessing the Effects of Heat Wave Mitigation Technology on Outdoor Thermal Comfort : Empirical Experiment to Verify the Effect of Cooling Fog
To provide Social Overhead Capital (SOC) for daily human lives, local governments are preparing various measures against heat waves, such as supplying Heat Wave Mitigation Facilities and supporting the vulnerable. Cooling Fog is a recent trend of Heat Wave Mitigation Facilities, but South Korea has limited data on reducing body temperature through direct application of cooling matter on the body, and most research on Cooling Fog has addressed technical aspects. In this study, to confirm the effect of Cooling Fog on the human body, experiments were conducted. First, the change of environmental factors in the space around the Cooling Fog was compared with an unaffected area. Second, a survey was conducted targeting people who use Cooling Fog to review its sensory effects. Finally, the effect of Cooling Fog was quantitatively verified by linking and analyzing related data. The air temperature and radiation temperature were lower in the area of Cooling Fog, but humidity was high. The sensory survey confirmed that Cooling Fog produced a sensation of cooler temperature compared to the area without Cooling Fog, as assessed using Thermal Sensation Vote (TSV), Heat Score, and Apparent Temperature (AT). In addition, the area of Cooling Fog was reported to have higher Thermal Comfort than the area without.
- 28 February 2022
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 13 (1) , 23-32
Assessing the Effects of Heatwave Mitigation Technology on Outdoor Thermal Comfort : Cool Pavement and Grass Block Installments
In disaster management, local governments strive to mitigate the impact of heatwaves through various practices and policies. This study evaluated the effectiveness of heat mitigation facilities built and managed by local governments. We quantified how comfortable individuals felt by interviewing citizens with structured questionnaires, given meteorological measures, and different ground surfaces, such as cool pavement, grass, and concrete blocks. Controlling for other factors, we found that respondents’ apparent temperature and Thermal Sensation Vote (TSV) in grass blocks were lower than other materials. However, we found no differences in apparent temperature and TSV between cool pavement and concrete blocks, suggesting no positive effect of cool pavement installation on surface temperature reduction. Additionally, the inverse relationship between Comfortable Sensation Vote (CSV) and TSV was confirmed. Even with the same CSV value, TSV was highest in the order of cool pavement, concrete block, and grass block. This study suggests a novel method to measure human sensation of thermal comfort in a quasi-experiment. Despite its limitation to a small sample size, the study provides alternative ways to measure thermal comfort and evaluate policy impacts.
- 28 February 2022
- Published by The Korean Society of Climate Change Research in Journal of Climate Change Research
- Vol. 13 (1) , 23-32
Assessing the Effects of Heatwave Mitigation Technology on Outdoor Thermal Comfort : Cool Pavement and Grass Block Installments
In disaster management, local governments strive to mitigate the impact of heatwaves through various practices and policies. This study evaluated the effectiveness of heat mitigation facilities built and managed by local governments. We quantified how comfortable individuals felt by interviewing citizens with structured questionnaires, given meteorological measures, and different ground surfaces, such as cool pavement, grass, and concrete blocks. Controlling for other factors, we found that respondents’ apparent temperature and Thermal Sensation Vote (TSV) in grass blocks were lower than other materials. However, we found no differences in apparent temperature and TSV between cool pavement and concrete blocks, suggesting no positive effect of cool pavement installation on surface temperature reduction. Additionally, the inverse relationship between Comfortable Sensation Vote (CSV) and TSV was confirmed. Even with the same CSV value, TSV was highest in the order of cool pavement, concrete block, and grass block. This study suggests a novel method to measure human sensation of thermal comfort in a quasi-experiment. Despite its limitation to a small sample size, the study provides alternative ways to measure thermal comfort and evaluate policy impacts.
- Open Access
- 30 June 2021
- Published by The Korean Solar Energy Society in Journal of the Korean Solar Energy Society
- Vol. 41 (3) , 183-192
Analysis of Energy Consumption Structure through Detailed Analysis of Energy Source Usage Pattern in Education Facilities
The environmental control systems used in educational facilities are diverse and obsolete. To provide safety for students and a pleasant learning environment, various systems are installed in learning spaces. In this study, on-site statistical surveys and energy consumption analyses were conducted in ten educational facilities in South Korea. Through awareness surveys of the persons in charge of education facilities, the energy conservation requirements were investigated. The system configuration was generalized according to the energy source, and through this, it was possible to determine the type of system used.
- 30 June 2021
- Published by The Korean Solar Energy Society in Journal of the Korean Solar Energy Society
- Vol. 41 (3) , 183-192
Open AccessAnalysis of Energy Consumption Structure through Detailed Analysis of Energy Source Usage Pattern in Education Facilities
The environmental control systems used in educational facilities are diverse and obsolete. To provide safety for students and a pleasant learning environment, various systems are installed in learning spaces. In this study, on-site statistical surveys and energy consumption analyses were conducted in ten educational facilities in South Korea. Through awareness surveys of the persons in charge of education facilities, the energy conservation requirements were investigated. The system configuration was generalized according to the energy source, and through this, it was possible to determine the type of system used.
- Open Access
- 9 March 2020
- Published by Copernicus GmbH
A Study on the Operation of Early Warning System for Heat Waves in Gwangju Based on the Urban Climatic Environment Assessment Model System
Damages in cities resulting from climate change are made irregularly and untypically, thus difficult to predict due to heavily concentrated buildings and population, etc. This study aims to introduce the results of our Urban Climatic Environment Assessment Model System(Model System hereinafter) as well as its construction, which is designed to provide impact assessment of heat waves in cities, to reduce damages, and to build capacities against it. Our Model System is based on the Unified Model(UM : an integrated model of Korea Meteorological Administration), and satellite data is necessary to verify the Model System. However, we have developed high resolution (10m ~ 100m) urban assessment model to analyze the impacts of heat waves in city of Gwangju to help local government by developing and implementing environmental policies. The outputs of our Model System will contribute to the decision making. Following two approaches were considered for impact assesment. Firstly, high spatial resolution model (in 10m to 100m level) using ensemble and down-scaling techniques can help identification of vulnerable areas in the city. Also, analyzed data can be linked to local GIS and land use map for analysis and assessment of the heat waves, which enables to make 48h heat wave forecast. Secondly, CFD micro-scale analysis using super-computer enables to analyze the vulnerable areas with components of : temperature, wind, humidity, solar radiation quantity, cloud cover, etc. Data achieved via our Model System will be used as objective and scientific basis for developing heat wave policies. It will also give guidance for heat wave early warning. It is expected that local governments can utilize our Model System to identify and analyze patterns and characteristics of heat waves in the city, and make decisions and develop environment-related policies on the objective and scientific basis preemptive response for vulnerable areas in the region. Keywords : heat waves, Urban Climatic Environment Assessment Model System, spatial resolution, ensemble average, down-scaling, CFD, micro-scale, Early warning system * This research was supported by a grant from Research Program funded by International Climate & Environment Center(ICEC).
- 9 March 2020
- Published by Copernicus GmbH
Open AccessA Study on the Operation of Early Warning System for Heat Waves in Gwangju Based on the Urban Climatic Environment Assessment Model System
Damages in cities resulting from climate change are made irregularly and untypically, thus difficult to predict due to heavily concentrated buildings and population, etc. This study aims to introduce the results of our Urban Climatic Environment Assessment Model System(Model System hereinafter) as well as its construction, which is designed to provide impact assessment of heat waves in cities, to reduce damages, and to build capacities against it. Our Model System is based on the Unified Model(UM : an integrated model of Korea Meteorological Administration), and satellite data is necessary to verify the Model System. However, we have developed high resolution (10m ~ 100m) urban assessment model to analyze the impacts of heat waves in city of Gwangju to help local government by developing and implementing environmental policies. The outputs of our Model System will contribute to the decision making. Following two approaches were considered for impact assesment. Firstly, high spatial resolution model (in 10m to 100m level) using ensemble and down-scaling techniques can help identification of vulnerable areas in the city. Also, analyzed data can be linked to local GIS and land use map for analysis and assessment of the heat waves, which enables to make 48h heat wave forecast. Secondly, CFD micro-scale analysis using super-computer enables to analyze the vulnerable areas with components of : temperature, wind, humidity, solar radiation quantity, cloud cover, etc. Data achieved via our Model System will be used as objective and scientific basis for developing heat wave policies. It will also give guidance for heat wave early warning. It is expected that local governments can utilize our Model System to identify and analyze patterns and characteristics of heat waves in the city, and make decisions and develop environment-related policies on the objective and scientific basis preemptive response for vulnerable areas in the region. Keywords : heat waves, Urban Climatic Environment Assessment Model System, spatial resolution, ensemble average, down-scaling, CFD, micro-scale, Early warning system * This research was supported by a grant from Research Program funded by International Climate & Environment Center(ICEC).