BKBulent Kose

Bulent Kose

*This is an algorithmically generated author record based on publicly available information.

Bulent Kose has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reply to “Within-Eye Cyclotorsion and Astigmatic Correction”

    by Husna Topcu, Mevlut Celal Ocal, Mehmet Altun, Ugur Tunc, Dilek Yasa, Gonul Karatas Durusoy, Atilla Hacıbekiroglu, Bulent Kose

  • Automated Versus Image-Guided Cyclotorsion Control in FS-LASIK: A Vector Analysis Study

    by Husna Topcu, Mevlut Celal Ocal, Mehmet Altun, Ugur Tunc, Dilek Yasa, Gonul Karatas Durusoy, Atilla Hacıbekiroglu, Bulent Kose

    Femtosecond laser–assisted in situ keratomileusis (FS-LASIK) is an established and effective procedure for the correction of myopic and hyperopic astigmatism. However, precise astigmatic correction...


  • Comparative effectiveness of VISUMAX 800 with keratorefractive lenticule extraction and FS-LASIK in the treatment of myopic astigmatism

    by Husna Topcu, Mehmet Altun, Mevlut Celal Ocal, Dilek Yasa, Gonul Karatas Durusoy, Bulent Kose

    Purpose: To compare the visual and refractive outcomes of keratorefractive lenticule extraction (KLEx) using the VISUMAX 800 femtosecond laser and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) performed using the VISUMAX 800 femtosecond laser and the EX500 excimer laser in the treatment of myopic astigmatism. Setting: Single-center, private ophthalmology center. Design: Retrospective comparative study. Methods: 237 eyes (133 KLEx, 104 FS-LASIK) were evaluated. Cyclotorsion alignment in KLEx was achieved using the Callisto Eye system integrated with VISUMAX 800. Refractive outcomes, vector analysis (Alpins method), and safety and efficacy indices were compared between groups at 1 month and 6 months postoperatively. Results: At 6 months, both groups achieved comparable uncorrected distance visual acuity (0.01 ± 0.04 logMAR) and corrected distance visual acuity. Mean spherical equivalent was closer to emmetropia in the KLEx group (−0.04 ± 0.18 diopters [D] vs −0.10 ± 0.15 D, P = .007). Residual cylinder was lower in KLEx (−0.14 ± 0.19 D vs −0.20 ± 0.20 D, P = .010). Vector analysis showed lower difference vector in KLEx (0.14 ± 0.19 D vs 0.21 ± 0.21 D, P = .009), while FS-LASIK had a slightly higher correction index (correction index: 1.02 vs 0.97, P = .005). Conclusions: Both KLEx and FS-LASIK performed using the VISUMAX 800 achieved excellent refractive outcomes, with KLEx procedures incorporating an image-guided static cyclotorsion alignment strategy and demonstrating excellent refractive and vector analysis results.


  • Open Access

    Clinical outcomes of image-guided cyclotorsion compensation during KLEx with the VISUMAX 800 in the absence of integrated software

    by Mevlut Celal Ocal, Husna Topcu, Mehmet Altun, Ugur Tunc, Dilek Yasa, Gonul Karatas Durusoy, Atilla Hacıbekiroglu, Bulent Kose

    Keratorefractive lenticule extraction (KLEx) is an established procedure for correcting myopia and myopic astigmatism. However, static cyclotorsion during

  • Open Access

    Panoptix versus AT Lisa: comparing stability of two trifocal intraocular lenses with different haptic designs using the iTrace system

    by Dilek Yasa, Husna Topcu, Mevlut Celal Ocal, Mehmet Altun, Gonul Karatas Durusoy, Bulent Kose

    The objective of this study was to compare the rotational stability of C-haptic PanOptix Toric (Alcon) and plate haptic AT Lisa Toric (Carl Zeiss Meditec)

  • Evaluation of moxifloxacin penetration into corneal lenticules extracted during SMILE surgery

    by Mehmet Altun, Mevlut Celal Ocal, Husna Topcu, Dilek Yasa, Gönül Karatas Durusoy, Bulent Kose, Yasar Sakarya

    Purpose To evaluate the penetration of topically applied moxifloxacin 0.5% in corneal lenticule tissue collected from healthy patients undergoing the Kerato Lenticule Extraction (KLEx) surgery. Methods Thirty-seven eyes of 37 patients received a single drop of moxifloxacin 0.5% before corneal lenticule tissue collection in KLEx surgery. The lenticule samples were divided into three groups according to collection time. Eight lenticules (21.6%) were included in group 1 (0.5 to 1.0 h), 19 lenticules (51.3%) in group 2 (1.0 to 1.5 h), and 10 lenticules (27.0%) in group 3 (1.5 to 2.0 h). The lenticules were stored at −80 °C until analysis. Moxifloxacin concentration in the lenticule tissue was measured using a validated liquid chromatography mass spectrometry (LC–MS/MS) technique. Results The mean corneal lenticule concentration of moxifloxacin was 22.54 ± 13.63 μg/g in group 1, 17.8 ± 10.88 μg/g in group 2, and 9.88 ± 4.2 μg/g in group 3. These concentrations were higher than the minimum inhibitory concentration (MIC) values of bacterial isolates, except Pseudomonas aeruginosa. Conclusion This study demonstrates that a single preoperative drop of moxifloxacin 0.5% achieves corneal tissue concentrations above the MIC for most bacterial pathogens except Pseudomonas aeruginosa. These results suggest that such prophylactic administration may effectively reduce the risk of post-operative infection in patients undergoing KLEx surgery.

  • An Apparatus for Fast Inspecting and Cleaning Connector

    by Paul Huang, Jose M. Castro, Thomas Sedor, Rick Pimpinella, Bulent Kose, Brett Lane

    In this paper, we present a novel apparatus that can inspect and clean the end face of the fiber-optic connector without the need to switch the connector from one tool to another.

  • Presbiyopi Düzeltici Göz İçi Lensler

    by Onur Ölçücü, Rüveyde Garip, Sibel Ahmet, Berkay Hasan Arman, Bülent Köse, Ahmet Kürşad Sakallıoğlu, Burçin Kepez Yıldız, Göksu Hande Naz Şimdivar, Burak Mergen, Tuğba Kurumoğlu İncekalan, et al.

    Katarakt cerrahisi son yıllarda gelişen teknoloji ve cerrahi teknikler ile birlikte başarılı bir şekilde uygulanan temel göz cerrahilerinden birisidir. Refraktif cerrahi olarak da ele alınması gereken bu cerrahide, uygulanacak göz içi lensin seçimi önem taşımaktadır. Günümüzde cerrahi sonrası yakın, orta ve uzak mesafenin net görülmesini sağlamaya yönelik göz içi lensler oldukça fazla sayıdadır. Bu kitap ile presbiyopi düzeltici göz içi lensleri uygulayan ve uygulamaya başlayacak meslektaşlarımızın bilgisine katkı sağlamak, farklı firmalara ait farklı göz içi lens modelleri hakkında bilgi vermek amaçlanmıştır. Kitabımızda genel olarak Türkiye’de kullanılan göz içi lensler olmak üzere, dünyada uygulanan ama ülkemizde bulunmayan bazı lenslere de yer verilmiştir. Sadece göz içi lensler değil bu lenslerin uygulanmasında, karşılaşılabilecek sorunlar ve çözümleri de incelenmiştir.

  • Comparison of refractive and visual outcomes between image-guided system–assisted small-incision lenticule extraction and wavefront-optimized FS-LASIK in treatment of high astigmatism

    by Bulent Kose

    Purpose: To compare the refractive and visual results of image-guided system–assisted small-incision lenticule extraction (IGA-SMILE) and wavefront-optimized femtosecond laser in situ keratomileusis (FS-LASIK) in the treatment of high astigmatism. Settings: Osmangazi Aritmi Hospital, Bursa, Turkey. Design: Retrospective. Methods: This retrospective case-matched study included 64 eyes that had undergone IGA-SMILE and 64 eyes that had undergone wavefront-optimized FS-LASIK. The mean preoperative myopia and astigmatism were −4.05 ± 1.98 diopter (D) and 3.11 ± 1.06 D in the IGA-SMILE group and −4.21 ± 2.23 D and −3.15 ± 0.62 D in the FS-LASIK group, respectively. One year later, visual and refractive results were compared in the groups. Vector analysis based on Alpins method was performed to evaluate astigmatic treatment. Results: 128 eyes of 128 patients were included in this study. At 1 year, the residual astigmatism was −0.21 ± 0.25 D in the IGA-SMILE group and −0.21 ± 0.24 D in the FS-LASIK group (P = .305). In the IGA-SMILE group, 57 eyes (89.1%) achieved uncorrected distance visual acuity of 20/20 or better, as did 56 eyes (85.9%) in the FS-LASIK group. Vector analysis results demonstrated that the difference vectors were 0.22 ± 0.24 D and 0.21 ± 0.22 D (P = .230), the correction indexes were 0.95 ± 0.08 and 0.95 ± 0.08 (P = .239), and the indices of success were 0.08 ± 0.09 and 0.08 ± 0.09 (P = .248) in the IGA-SMILE and the FS-LASIK groups, respectively. Conclusions: The combination of an image-guided system with SMILE resulted in high efficacy and safety indices that were comparable with FS-LASIK surgery.


  • Agreement between swept-source optical biometry and Scheimpflug-based topography measurements of posterior corneal curvature

    by Bulent Kose

    Purpose: To evaluate agreement of posterior corneal curvature parameters between a swept-source optical coherence tomography–based biometer (IOLMaster 700) and Scheimpflug topography (Pentacam HR) in healthy, myopic eyes. Setting: Department of Ophthalmology, Osmangazi Aritmi Hospital, Bursa, Turkey. Design: Retrospective study. Methods: In this study, 59 eyes of 59 patients who applied as candidates for refractive surgery were included. Measurements of the posterior corneal curvature were performed using IOLMaster 700 and Pentacam HR. J0 and J45 vector components were calculated using astigmatic values. Posterior corneal keratometry (K) measurements at flat (K flat) and steep (K steep) axes and J0 and J45 values were compared between the 2 devices. The agreement between the devices was analyzed using the Bland-Altman method. Intraclass correlation coefficients and within-subject SD were calculated to assess the repeatability. Results: 59 eyes of 59 patients were included in this study. The IOLMaster 700 provided significantly flatter K flat and K steep values (P < .001, for both). Significant differences were found in J0 and J45 values (P = 0.13 and P < .001, respectively). The mean differences between K flat, K steep, and J0 and J45 values were 0.49 diopter (D), 0.53 D, 0.04 D, and −0.05 D, respectively. Conclusions: The IOLMaster 700 and the Pentacam HR could not be used interchangeably to measure K flat, K steep, and J0 and J45 values of the posterior corneal curvature in healthy, myopic eyes. Both devices showed high repeatability for posterior corneal curvature measurement.