Alexandria Michelini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alexandria Michelini has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jan Andrysek
Institute of Biomedical Engineering, University of Toronto
5 shared publications Arezoo Eshraghi
Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Ontario, Canada
2 shared publications- Arezoo Eshraghi
West Park Healthcare Centre, University Health Network, Toronto, Ontario, Canada
1 shared publication - Harry Sivasambu
Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Canada
1 shared publication Phearsa Thor
Exceed Worldwide, Lisburn Square, Lisburn, United Kingdon
1 shared publication- Phearsa Thor
Exceed Worldwide Cambodia, Department of Prosthetics and Orthotic, National Institute of Social Affairs, #20C, Doung Ngeap II Street, Steung Meanchey, Khan Meanchey, Phnom Penh 120603, Cambodia
1 shared publication
Latest Publications
- Open Access
- 15 March 2022
- Published by MDPI AG in Prosthesis
- Vol. 4 (1) , 125-135
Gait Performance of Friction-Based Prosthetic Knee Joint Swing-Phase Controllers in Under-Resourced Settings
Gait quality can influence walking ability and mobility outcomes making it an important part of prosthetic rehabilitation. Prosthetic knee joint designs can influence gait quality, and limited data exists to guide component selection in under-resourced settings. This study compared spatiotemporal and kinematic gait parameters for two common types of friction-based swing-phase controlled prosthetic knee joints. Two-dimensional optical gait analysis was conducted as part of a cross-over study design involving 17 individuals with unilateral transfemoral amputations. Two prosthetic knee joints were compared. One utilized constant-friction (CF) and the other a variable cadence controller (VCC) for swing-phase control. Gait was analyzed at normal and fast walking speeds. Primary gait parameters included swing-phase time, step length, and knee flexion. Swing-phase time and peak knee flexion angles, as well as their related symmetry indices, were lower for the VCC compared to the CF (p < 0.01), by 11.1 to 94.1%. The VCC resulted in faster walking speeds by approximately 15% compared to the CF (p = 0.002). Friction-based swing-phase knee control mechanisms can facilitate an appropriate and cost-effective prosthetic knee joint solution in under-resourced settings. The findings suggest that friction-based mechanism can be designed to improve gait quality, and in turn overall walking performance.
- 15 March 2022
- Published by MDPI AG in Prosthesis
- Vol. 4 (1) , 125-135
Open AccessGait Performance of Friction-Based Prosthetic Knee Joint Swing-Phase Controllers in Under-Resourced Settings
Gait quality can influence walking ability and mobility outcomes making it an important part of prosthetic rehabilitation. Prosthetic knee joint designs can influence gait quality, and limited data exists to guide component selection in under-resourced settings. This study compared spatiotemporal and kinematic gait parameters for two common types of friction-based swing-phase controlled prosthetic knee joints. Two-dimensional optical gait analysis was conducted as part of a cross-over study design involving 17 individuals with unilateral transfemoral amputations. Two prosthetic knee joints were compared. One utilized constant-friction (CF) and the other a variable cadence controller (VCC) for swing-phase control. Gait was analyzed at normal and fast walking speeds. Primary gait parameters included swing-phase time, step length, and knee flexion. Swing-phase time and peak knee flexion angles, as well as their related symmetry indices, were lower for the VCC compared to the CF (p < 0.01), by 11.1 to 94.1%. The VCC resulted in faster walking speeds by approximately 15% compared to the CF (p = 0.002). Friction-based swing-phase knee control mechanisms can facilitate an appropriate and cost-effective prosthetic knee joint solution in under-resourced settings. The findings suggest that friction-based mechanism can be designed to improve gait quality, and in turn overall walking performance.
- Open Access
- 1 January 2022
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 5 (1)
THE SHORT-TERM EFFECTS OF RHYTHMIC VIBROTACTILE AND AUDITORY BIOFEEDBACK ON THE GAIT OF INDIVIDUALS AFTER WEIGHT-INDUCED ASYMMETRY
BACKGROUND: Biofeedback (BFB), the practice of providing real-time sensory feedback has been shown to improve gait rehabilitation outcomes. BFB training through rhythmic stimulation has the potential to improve spatiotemporal gait asymmetries while minimizing cognitive load by encouraging a synchronization between the user’s gait cycle and an external rhythm. OBJECTIVE: The purpose of this work was to evaluate if rhythmic stimulation can improve the stance time symmetry ratio (STSR) and to compare vibrotactile to auditory stimulation. Gait parameters including velocity, cadence, stride length, double support time, and step length symmetry, were also examined. METHODOLOGY: An experimental rhythmic stimulation system was developed, and twelve healthy adults (5 males), age 28.42 ± 10.93 years, were recruited to participate in walking trials. A unilateral ankle weight was used to induce a gait asymmetry to simulate asymmetry as commonly exhibited by individuals with lower limb amputation and other clinical disorders. Four conditions were evaluated: 1) No ankle weight baseline, 2) ankle weight without rhythmic stimulation, 3) ankle weight + rhythmic vibrotactile stimulation (RVS) using alternating motors and 4) ankle weight + rhythmic auditory stimulation (RAS) using a single-tone metronome at the participant’s self-selected cadence. FINDINGS: As expected the STSR became significantly more asymmetrical with the ankle weight (i.e. induced asymmetry condition). STSR improved significantly with RVS and RAS when compared to the ankle weight without rhythmic stimulation. Cadence also significantly improved with RVS and RAS compared to ankle weight without rhythmic stimulation. With the exception of double support time, the other gait parameters were unchanged from the ankle weight condition. There were no statistically significant differences between RVS and RAS. CONCLUSION: This study found that rhythmic stimulation can improve the STSR when an asymmetry is induced. Moreover, RVS is at least as effective as auditory stimulation in improving STSR in healthy adults with an induced gait asymmetry. Future work should be extended to populations with mobility impairments and outside of laboratory settings. Layman's Abstract Providing feedback to users in real-time has been shown to improve walking in many populations with gait deviations. Feedback in the form of rhythmic stimulation involves consistent cues to which the user matches their movement. This work compared the effects of sound-based (RAS) and vibration-based (RVS) stimulation systems on the walking symmetry of healthy adults. A simple stimulation system was used with twelve healthy adults in walking trials. The walking trials included some in which the participant wore an ankle weight on a single leg to create a non-symmetrical walking pattern. Four different conditions were tested: No ankle weight, with an ankle weight, with an ankle weight and RAS, and with an ankle weight and RVS. Walking symmetry improved with both RVS and RAS compared to ankle weight only. Walking speed, cadence, and step length did not change. These findings show that RVS is at least as effective as RAS and may be a useful technique for gait rehabilitation. Future work should involve clinical populations and in real-world settings. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36223/29090 How To Cite: Michelini A., Sivasambu H., Andrysek J. The short-term effects of rhythmic vibrotactile and auditory biofeedback on the gait of individuals after weight-induced asymmetry. Canadian Prosthetics & Orthotics Journal. 2022; Volume 5, Issue 1, No.6. https://doi.org/10.33137/cpoj.v5i1.36223 Corresponding Author: Jan Andrysek, PhDBloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Canada.,E-Mail: jandrysek@hollandbloorview.ca ORCID ID: https://orcid.org/0000-0002-4976-1228
- 1 January 2022
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 5 (1)
Open AccessTHE SHORT-TERM EFFECTS OF RHYTHMIC VIBROTACTILE AND AUDITORY BIOFEEDBACK ON THE GAIT OF INDIVIDUALS AFTER WEIGHT-INDUCED ASYMMETRY
BACKGROUND: Biofeedback (BFB), the practice of providing real-time sensory feedback has been shown to improve gait rehabilitation outcomes. BFB training through rhythmic stimulation has the potential to improve spatiotemporal gait asymmetries while minimizing cognitive load by encouraging a synchronization between the user’s gait cycle and an external rhythm. OBJECTIVE: The purpose of this work was to evaluate if rhythmic stimulation can improve the stance time symmetry ratio (STSR) and to compare vibrotactile to auditory stimulation. Gait parameters including velocity, cadence, stride length, double support time, and step length symmetry, were also examined. METHODOLOGY: An experimental rhythmic stimulation system was developed, and twelve healthy adults (5 males), age 28.42 ± 10.93 years, were recruited to participate in walking trials. A unilateral ankle weight was used to induce a gait asymmetry to simulate asymmetry as commonly exhibited by individuals with lower limb amputation and other clinical disorders. Four conditions were evaluated: 1) No ankle weight baseline, 2) ankle weight without rhythmic stimulation, 3) ankle weight + rhythmic vibrotactile stimulation (RVS) using alternating motors and 4) ankle weight + rhythmic auditory stimulation (RAS) using a single-tone metronome at the participant’s self-selected cadence. FINDINGS: As expected the STSR became significantly more asymmetrical with the ankle weight (i.e. induced asymmetry condition). STSR improved significantly with RVS and RAS when compared to the ankle weight without rhythmic stimulation. Cadence also significantly improved with RVS and RAS compared to ankle weight without rhythmic stimulation. With the exception of double support time, the other gait parameters were unchanged from the ankle weight condition. There were no statistically significant differences between RVS and RAS. CONCLUSION: This study found that rhythmic stimulation can improve the STSR when an asymmetry is induced. Moreover, RVS is at least as effective as auditory stimulation in improving STSR in healthy adults with an induced gait asymmetry. Future work should be extended to populations with mobility impairments and outside of laboratory settings. Layman's Abstract Providing feedback to users in real-time has been shown to improve walking in many populations with gait deviations. Feedback in the form of rhythmic stimulation involves consistent cues to which the user matches their movement. This work compared the effects of sound-based (RAS) and vibration-based (RVS) stimulation systems on the walking symmetry of healthy adults. A simple stimulation system was used with twelve healthy adults in walking trials. The walking trials included some in which the participant wore an ankle weight on a single leg to create a non-symmetrical walking pattern. Four different conditions were tested: No ankle weight, with an ankle weight, with an ankle weight and RAS, and with an ankle weight and RVS. Walking symmetry improved with both RVS and RAS compared to ankle weight only. Walking speed, cadence, and step length did not change. These findings show that RVS is at least as effective as RAS and may be a useful technique for gait rehabilitation. Future work should involve clinical populations and in real-world settings. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/36223/29090 How To Cite: Michelini A., Sivasambu H., Andrysek J. The short-term effects of rhythmic vibrotactile and auditory biofeedback on the gait of individuals after weight-induced asymmetry. Canadian Prosthetics & Orthotics Journal. 2022; Volume 5, Issue 1, No.6. https://doi.org/10.33137/cpoj.v5i1.36223 Corresponding Author: Jan Andrysek, PhDBloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Canada.,E-Mail: jandrysek@hollandbloorview.ca ORCID ID: https://orcid.org/0000-0002-4976-1228
- 16 September 2021
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 45 (6) , 463-469
Functional outcomes and user preferences of individuals with transfemoral amputations using two types of knee joints in under-resourced settings
Background: Information relating to prosthetic performance can inform clinical practice and improve patient outcomes in under-resourced countries. Objectives: The main goal of this study was to compare functional outcomes and user preferences of individuals with transfemoral amputations using common types of knee joints in an under-resourced country. Study design: Prospective, longitudinal, before and after trial. Methods: Twenty individuals with unilateral transfemoral amputations from a center in Cambodia transitioned from a commonly used single-axis manually locking knee International Committee of the Red Cross (ICRC) to a more advanced multiaxis knee joint with stance control All-Terrain Knee (ATK). Data were collected for the ICRC knee joint and the ATK immediately after fitting, after acclimation, and as part of a long-term follow-up. A timed walk test assessed walking distance and efficiency. Mobility and user-preferences were evaluated through questionnaires. Results: Distance during the timed walk test was significantly higher for the ATK compared with ICRC (P < 0.001), with functional gains retained at follow-up. No differences were found for gait efficiency and the mobility questionnaires. All participants, except one, preferred the ATK prosthesis. Benefits included greater knee stability and fewer perceived knee collapses; however, some disliked the appearance of the ATK. Conclusions: The findings suggest positive outcomes with prosthetic services in under-resourced regions and the ICRC system, as well as the potential for improved functional outcomes with more advanced multiaxis knee components.
- 16 September 2021
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 45 (6) , 463-469
Functional outcomes and user preferences of individuals with transfemoral amputations using two types of knee joints in under-resourced settings
Background: Information relating to prosthetic performance can inform clinical practice and improve patient outcomes in under-resourced countries. Objectives: The main goal of this study was to compare functional outcomes and user preferences of individuals with transfemoral amputations using common types of knee joints in an under-resourced country. Study design: Prospective, longitudinal, before and after trial. Methods: Twenty individuals with unilateral transfemoral amputations from a center in Cambodia transitioned from a commonly used single-axis manually locking knee International Committee of the Red Cross (ICRC) to a more advanced multiaxis knee joint with stance control All-Terrain Knee (ATK). Data were collected for the ICRC knee joint and the ATK immediately after fitting, after acclimation, and as part of a long-term follow-up. A timed walk test assessed walking distance and efficiency. Mobility and user-preferences were evaluated through questionnaires. Results: Distance during the timed walk test was significantly higher for the ATK compared with ICRC (P < 0.001), with functional gains retained at follow-up. No differences were found for gait efficiency and the mobility questionnaires. All participants, except one, preferred the ATK prosthesis. Benefits included greater knee stability and fewer perceived knee collapses; however, some disliked the appearance of the ATK. Conclusions: The findings suggest positive outcomes with prosthetic services in under-resourced regions and the ICRC system, as well as the potential for improved functional outcomes with more advanced multiaxis knee components.
- 1 August 2020
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 44 (4) , 245-262
Two-dimensional video gait analysis
Motion capture systems are widely used to quantify human gait. Two-dimensional (2D) video systems are simple to use, easily accessible, and affordable. However, their performance as compared to other systems (i.e. three-dimensional (3D) gait analysis) is not well established. This work provides a comprehensive review of design specifications and performance characteristics (validity and reliability) of two-dimensional motion capture systems. Systematic review. A systematic literature search was conducted in three databases from 1990 to 2019 and identified 30 research articles that met the inclusion/exclusion criteria. Reliability of measurements of two-dimensional video motion capture was found to vary greatly from poor to excellent. Results relating to validity were also highly variable. Comparisons between the studies were challenging due to differences in protocols, instrumentation, parameters assessed, and analyses performed. Variability in performance could be attributed to study design, gait parameters being measured, and technical aspects. The latter includes camera specifications (i.e. resolution and frame rate), setup (i.e. camera position), and analysis software. Given the variability in performance, additional validation testing may be needed for specific applications involving clinical or research-based assessments, including specific patient populations, gait parameters, mobility tasks, and data collection protocols. This review article provides guidance on the application of 2D video gait analysis in a clinical or research setting. While not suitable in all instances, 2D gait analysis has promise in specific applications. Recommendations are provided about the patient populations, gait parameters, mobility tasks, and data collection protocols.
- 1 August 2020
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 44 (4) , 245-262
Two-dimensional video gait analysis
Motion capture systems are widely used to quantify human gait. Two-dimensional (2D) video systems are simple to use, easily accessible, and affordable. However, their performance as compared to other systems (i.e. three-dimensional (3D) gait analysis) is not well established. This work provides a comprehensive review of design specifications and performance characteristics (validity and reliability) of two-dimensional motion capture systems. Systematic review. A systematic literature search was conducted in three databases from 1990 to 2019 and identified 30 research articles that met the inclusion/exclusion criteria. Reliability of measurements of two-dimensional video motion capture was found to vary greatly from poor to excellent. Results relating to validity were also highly variable. Comparisons between the studies were challenging due to differences in protocols, instrumentation, parameters assessed, and analyses performed. Variability in performance could be attributed to study design, gait parameters being measured, and technical aspects. The latter includes camera specifications (i.e. resolution and frame rate), setup (i.e. camera position), and analysis software. Given the variability in performance, additional validation testing may be needed for specific applications involving clinical or research-based assessments, including specific patient populations, gait parameters, mobility tasks, and data collection protocols. This review article provides guidance on the application of 2D video gait analysis in a clinical or research setting. While not suitable in all instances, 2D gait analysis has promise in specific applications. Recommendations are provided about the patient populations, gait parameters, mobility tasks, and data collection protocols.
- Open Access
Biofeedback Systems for Gait Rehabilitation of Individuals with Lower-Limb Amputation: A Systematic Review
Individuals with lower-limb amputation often have gait deficits and diminished mobility function. Biofeedback systems have the potential to improve gait rehabilitation outcomes. Research on biofeedback has steadily increased in recent decades, representing the growing interest toward this topic. This systematic review highlights the methodological designs, main technical and clinical challenges, and evidence relating to the effectiveness of biofeedback systems for gait rehabilitation. This review provides insights for developing an effective, robust, and user-friendly wearable biofeedback system. The literature search was conducted on six databases and 31 full-text articles were included in this review. Most studies found biofeedback to be effective in improving gait. Biofeedback was most commonly concurrently provided and related to limb loading and symmetry ratios for stance or step time. Visual feedback was the most used modality, followed by auditory and haptic. Biofeedback must not be obtrusive and ideally provide a level of enjoyment to the user. Biofeedback appears to be most effective during the early stages of rehabilitation but presents some usability challenges when applied to the elderly. More research is needed on younger populations and higher amputation levels, understanding retention as well as the relationship between training intensity and performance.
Open AccessBiofeedback Systems for Gait Rehabilitation of Individuals with Lower-Limb Amputation: A Systematic Review
Individuals with lower-limb amputation often have gait deficits and diminished mobility function. Biofeedback systems have the potential to improve gait rehabilitation outcomes. Research on biofeedback has steadily increased in recent decades, representing the growing interest toward this topic. This systematic review highlights the methodological designs, main technical and clinical challenges, and evidence relating to the effectiveness of biofeedback systems for gait rehabilitation. This review provides insights for developing an effective, robust, and user-friendly wearable biofeedback system. The literature search was conducted on six databases and 31 full-text articles were included in this review. Most studies found biofeedback to be effective in improving gait. Biofeedback was most commonly concurrently provided and related to limb loading and symmetry ratios for stance or step time. Visual feedback was the most used modality, followed by auditory and haptic. Biofeedback must not be obtrusive and ideally provide a level of enjoyment to the user. Biofeedback appears to be most effective during the early stages of rehabilitation but presents some usability challenges when applied to the elderly. More research is needed on younger populations and higher amputation levels, understanding retention as well as the relationship between training intensity and performance.