N. Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
N. Du has a total of 147 co-authors. Here are the top co-authors by number of shared publications:
N. Woollett
Lawrence Livermore National Laboratory
5 shared publicationsA. S. Chou
Fermi National Accelerator Laboratory
4 shared publicationsA. Sonnenschein
Fermi National Accelerator Laboratory
4 shared publicationsE. Lentz
Pacific Northwest National Laboratory
4 shared publicationsG. Carosi
Lawrence Livermore National Laboratory
4 shared publicationsI. Siddiqi
University of California
4 shared publications
Latest Publications
- 3 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (10)
Search for nonvirialized axions with 3.3 − 4.2 μ eV mass at selected resolving powers
- 3 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (10)
Search for nonvirialized axions with 3.3 − 4.2 μ eV mass at selected resolving powers
- Open Access
- 3 November 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (19) , 191001
Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX
Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong C P problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10 and 1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.
- 3 November 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (19) , 191001
Open AccessSearch for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX
Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong C P problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10 and 1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.
- Open Access
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Dark matter axion search using a Josephson Traveling wave parametric amplifier
We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10−13 Ge V−1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Open AccessDark matter axion search using a Josephson Traveling wave parametric amplifier
We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10−13 Ge V−1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 033102
Multi-mode analysis of surface losses in a superconducting microwave resonator in high magnetic fields
This paper reports on a surface impedance measurement of a bulk metal niobium–titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to 10 T). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple TM cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 033102
Multi-mode analysis of surface losses in a superconducting microwave resonator in high magnetic fields
This paper reports on a surface impedance measurement of a bulk metal niobium–titanium superconducting radio frequency (SRF) cavity in a magnetic field (up to 10 T). A novel method is employed to decompose the surface resistance contributions of the cylindrical cavity end caps and walls using measurements from multiple TM cavity modes. The results confirm that quality factor degradation of a NbTi SRF cavity in a high magnetic field is primarily from surfaces perpendicular to the field (the cavity end caps), while parallel surface resistances (the walls) remain relatively constant. This result is encouraging for applications needing high Q cavities in strong magnetic fields, such as the Axion Dark Matter eXperiment because it opens the possibility of hybrid SRF cavity construction to replace conventional copper cavities.
- Top Cited PapersOpen Access
- 11 March 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 124 (10) , 101303
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
This Letter reports on a cavity haloscope search for dark matter axions in the Galactic halo in the mass range . This search utilizes the combination of a low-noise Josephson parametric amplifier and a large-cavity haloscope to achieve unprecedented sensitivity across this mass range. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong problem of quantum chromodynamics.- 11 March 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 124 (10) , 101303
Top Cited PapersOpen AccessExtended Search for the Invisible Axion with the Axion Dark Matter Experiment
This Letter reports on a cavity haloscope search for dark matter axions in the Galactic halo in the mass range . This search utilizes the combination of a low-noise Josephson parametric amplifier and a large-cavity haloscope to achieve unprecedented sensitivity across this mass range. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong problem of quantum chromodynamics. - 1 January 2020
- Published by Springer Nature
- p. 17-22
Recent Results with the ADMX Experiment
- Open Access
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ ${\mu}eV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.Open AccessExtended Search for the Invisible Axion with the Axion Dark Matter Experiment
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ ${\mu}eV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.