Carlos Martin Pezzani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carlos Martin Pezzani has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Cristian Hernan De Angelo
National University of Rio Cuarto
4 shared publications - Pablo Daniel Donolo
Universidad Nacional de Río Cuarto
4 shared publications - Guillermo Ruben Bossio
Applied Electronics Group, Faculty of Engineering, National University of Río Cuarto, Río Cuarto, Crdoba, Argentina
3 shared publications - Marcos Donolo
Schweitzer Engineering Laboratories, Inc
2 shared publications Ayelen Susana Lifschitz
IITEMA, Univ. Nacional de Rio Cuarto, Argentina
1 shared publicationEliana Chiacchiera
IITEMA, Univ. Nacional de Rio Cuarto, Argentina
1 shared publication
Latest Publications
- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 2913-2918
Vibration Magnitude Analysis on Induction Motors of Different Efficiency Classes Due to Voltage Unbalance
Small efficiency improvement in induction motors (IMs) often lead to large monetary savings over time. These monetary savings justify the current movement toward the use of higher efficiency IMs. In many cases, replacing a standard efficiency IM with a higher efficiency one is transparent to the user. In other cases, however, there are side effects which need to be considered. This paper presents data showing that vibrations due to voltage unbalance are significantly more pronounced on higher efficiency IMs than in standard efficiency ones. This paper presents the mathematical expressions for active power for an IM under voltage unbalance. Then the paper describes a dynamic simulation framework to validate the paper's hypothesis over a wide range of IMs and a laboratory the test setup used to validate the mathematical expressions with experimental results of standard (IE1), premium (IE3) and super premium (IE4) IMs. Finally, the paper presents vibration measurements due voltage unbalance, and compares the results with the measured vibration levels with the ISO 20816-1 standard vibration severity guidelines
- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 2913-2918
Vibration Magnitude Analysis on Induction Motors of Different Efficiency Classes Due to Voltage Unbalance
Small efficiency improvement in induction motors (IMs) often lead to large monetary savings over time. These monetary savings justify the current movement toward the use of higher efficiency IMs. In many cases, replacing a standard efficiency IM with a higher efficiency one is transparent to the user. In other cases, however, there are side effects which need to be considered. This paper presents data showing that vibrations due to voltage unbalance are significantly more pronounced on higher efficiency IMs than in standard efficiency ones. This paper presents the mathematical expressions for active power for an IM under voltage unbalance. Then the paper describes a dynamic simulation framework to validate the paper's hypothesis over a wide range of IMs and a laboratory the test setup used to validate the mathematical expressions with experimental results of standard (IE1), premium (IE3) and super premium (IE4) IMs. Finally, the paper presents vibration measurements due voltage unbalance, and compares the results with the measured vibration levels with the ISO 20816-1 standard vibration severity guidelines
- 8 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (5) , 726-734
Stator Faults Detection on Induction Motors Using Harmonic Sequence Current Components Analysis
In this paper we propose a strategy for detecting interturn short circuits on stator windings of three-phase induction motors (IM). The strategy is based on an analytical model that includes a stator fault in any of the phase windings considering the h-th harmonic in the supply voltage. To find the adequate model, we propose an equivalent electrical circuit of the IM in steady state, considering each sequence component. The proposed strategy allows the detection of an interturn short-circuit fault by monitoring the fifth-order harmonic component. We present simulation and experimental results for the faulty IM and different operating conditions. In the laboratory tests, we use a programmable power supply in order to synthesize distorted and unbalance voltages. Also, the windings of a three-phase IM have been modified to generate stator faults and validate the proposed model. The results show that the sustained increase of the fifth-order harmonic of positive-sequence current is a good indicator of the fault severity.
- 8 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 19 (5) , 726-734
Stator Faults Detection on Induction Motors Using Harmonic Sequence Current Components Analysis
In this paper we propose a strategy for detecting interturn short circuits on stator windings of three-phase induction motors (IM). The strategy is based on an analytical model that includes a stator fault in any of the phase windings considering the h-th harmonic in the supply voltage. To find the adequate model, we propose an equivalent electrical circuit of the IM in steady state, considering each sequence component. The proposed strategy allows the detection of an interturn short-circuit fault by monitoring the fifth-order harmonic component. We present simulation and experimental results for the faulty IM and different operating conditions. In the laboratory tests, we use a programmable power supply in order to synthesize distorted and unbalance voltages. Also, the windings of a three-phase IM have been modified to generate stator faults and validate the proposed model. The results show that the sustained increase of the fifth-order harmonic of positive-sequence current is a good indicator of the fault severity.
- 1 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 18 (10) , 1817-1825
Economic Barriers to the Application of Energy Efficient Motors in Industry
In this paper we present a technical, economic and financial feasibility analysis of the replacement a standard-efficiency induction motor (IE1) by a Premium-efficiency induction motor (IE3) in an industrial application. We consider a press used for the production of crude degummed soybean oil and soybean expeller, from an industry in the Province of Cordoba, Argentina. We use a model of the induction motor that drives the press to correctly estimate the load level and the performance of the induction motor currently used. With the data obtained from the model, we analyze the economic and financial feasibility of the induction motor replacement for the registered operating conditions, with the current energy prices and the associated subsidies. We calculate different indicators for the current scenario and future forecasts. The results show that, in the current context of high interest rates and high subsidies to electric power, economic barriers may exist to the replacement of induction motors by the higher efficiency class. However, the analysis with future scenarios of lower subsidies for electric power and / or lower interest rates on financial income can cause these barriers to be removed.
- 1 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 18 (10) , 1817-1825
Economic Barriers to the Application of Energy Efficient Motors in Industry
In this paper we present a technical, economic and financial feasibility analysis of the replacement a standard-efficiency induction motor (IE1) by a Premium-efficiency induction motor (IE3) in an industrial application. We consider a press used for the production of crude degummed soybean oil and soybean expeller, from an industry in the Province of Cordoba, Argentina. We use a model of the induction motor that drives the press to correctly estimate the load level and the performance of the induction motor currently used. With the data obtained from the model, we analyze the economic and financial feasibility of the induction motor replacement for the registered operating conditions, with the current energy prices and the associated subsidies. We calculate different indicators for the current scenario and future forecasts. The results show that, in the current context of high interest rates and high subsidies to electric power, economic barriers may exist to the replacement of induction motors by the higher efficiency class. However, the analysis with future scenarios of lower subsidies for electric power and / or lower interest rates on financial income can cause these barriers to be removed.
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 961-969
Derating of Induction Motors Due to Power Quality Issues Considering the Motor Efficiency Class
Heating and losses of induction motor (IM) grow with the supply voltage unbalance and harmonic distortion. To avoid thermal overload, the IEEE 141-1993, the IEEE 3004.8, NEMA MG1-2014, and the IEC 60034-26 standards establish derating factors for IMs operating under those conditions. In this article, we show that while the derating factors proposed by these standards adequately protect standard-efficiency IMs, they are only marginally adequate to protect modern higher-efficiency IMs. To this end, we compare the derating factors provided by the standards with the derating factors required to maintain the losses at rated values in a standard-efficiency IM, in a premium-efficiency IM, and in a super-premium-efficiency IM. To extrapolate the results from these IM, we compared the nameplate data of 548 IMs of different efficiency classes and found that higher efficiency classes correlate to higher IM starting currents and lower impedances to the negative sequence and harmonic voltages. These lower impedances in turn may lead to higher losses for unbalanced and harmonic voltages conditions.
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 961-969
Derating of Induction Motors Due to Power Quality Issues Considering the Motor Efficiency Class
Heating and losses of induction motor (IM) grow with the supply voltage unbalance and harmonic distortion. To avoid thermal overload, the IEEE 141-1993, the IEEE 3004.8, NEMA MG1-2014, and the IEC 60034-26 standards establish derating factors for IMs operating under those conditions. In this article, we show that while the derating factors proposed by these standards adequately protect standard-efficiency IMs, they are only marginally adequate to protect modern higher-efficiency IMs. To this end, we compare the derating factors provided by the standards with the derating factors required to maintain the losses at rated values in a standard-efficiency IM, in a premium-efficiency IM, and in a super-premium-efficiency IM. To extrapolate the results from these IM, we compared the nameplate data of 548 IMs of different efficiency classes and found that higher efficiency classes correlate to higher IM starting currents and lower impedances to the negative sequence and harmonic voltages. These lower impedances in turn may lead to higher losses for unbalanced and harmonic voltages conditions.