Eugen Kludt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eugen Kludt has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Andreas Büchner
Department of Otolaryngology, Medical University Hannover Results
7 shared publications- Thomas Lenarz
Department of Otolaryngology, Hannover Medical School, Hannover, Germany
5 shared publications Thomas Lenarz
Affiliations Department of Otolaryngology, Medical University of Hannover, Hanover, Germany, Hearing4all, Oldenburg, Germany
4 shared publications- Andreas Büchner
Department of Otolaryngology, Hannover Medical School, Hannover, Germany
3 shared publications - Lutz Gärtner
Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany
3 shared publications - Anke Lesinski-Schiedat
Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
2 shared publications
Latest Publications
- Open Access
- 21 May 2026
- Published by IOS Press
- Vol. 336, 213-217
A Data-Driven Visit Windowing Approach Applied to Cochlear Implant Follow-Up Data
Introduction: Cochlear implant (CI) patients require regular follow-up care over multiple visits to achieve optimal hearing outcomes. In clinical routine, however, visits rarely occur on the exact scheduled dates and cluster around them, reducing reproducibility and comparability of CI analyses. To address these limitations, a data-driven visit windowing (DDW) approach was developed and evaluated against a study-protocol visit window (SPW) scheme. Methods: The distribution of 31,344 speech test visits from 5,264 patients implanted at Hannover Medical School was analyzed to define (1) visit windows with beginning and ending time points, and (2) a rule to select the most representative visit. Results: This approach demonstrates that variable-length, contiguous, data-driven windows are reproducible for future data and capture variability in visit timing. Compared to SPW, DDW covered a higher proportion of visits (+40.3 pp) and achieved slightly lower prediction errors for speech recognition (e.g., MAE 11.9 vs. 13.0 for Polynomial Ridge Regression). Conclusion: The DDW approach provides a reproducible, extensible, and clinically grounded basis for visit definitions, enabling consistent longitudinal CI analyses, improved data quality and predictions, and comparisons across centers and studies.
- 21 May 2026
- Published by IOS Press
- Vol. 336, 213-217
Open AccessA Data-Driven Visit Windowing Approach Applied to Cochlear Implant Follow-Up Data
Introduction: Cochlear implant (CI) patients require regular follow-up care over multiple visits to achieve optimal hearing outcomes. In clinical routine, however, visits rarely occur on the exact scheduled dates and cluster around them, reducing reproducibility and comparability of CI analyses. To address these limitations, a data-driven visit windowing (DDW) approach was developed and evaluated against a study-protocol visit window (SPW) scheme. Methods: The distribution of 31,344 speech test visits from 5,264 patients implanted at Hannover Medical School was analyzed to define (1) visit windows with beginning and ending time points, and (2) a rule to select the most representative visit. Results: This approach demonstrates that variable-length, contiguous, data-driven windows are reproducible for future data and capture variability in visit timing. Compared to SPW, DDW covered a higher proportion of visits (+40.3 pp) and achieved slightly lower prediction errors for speech recognition (e.g., MAE 11.9 vs. 13.0 for Polynomial Ridge Regression). Conclusion: The DDW approach provides a reproducible, extensible, and clinically grounded basis for visit definitions, enabling consistent longitudinal CI analyses, improved data quality and predictions, and comparisons across centers and studies.
- Open Access
- 28 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Threshold-distance functions predict speech recognition with cochlear implants
Cochlear implantation shows unexplained outcome variability. Among the key factors affecting outcomes measured by speech understanding is the functional state of the auditory nerve and the amount of its degeneration due to hearing loss. In the present study we actively varied the distance of the stimulating electrodes from the modiolus (the spiral ganglion), quantified it using fluoroscopy and cone-beam computed tomography and related it to electrically-evoked compound action potentials (eCAPs) in human subjects. Stimulation was monopolar. The distance from modiolus could explain up to 91% of the variability in the thresholds of eCAPs. The threshold varied between participants. For individual electrodes of the implant in the given participant, a linear relationship between threshold (in current level) and distance from modiolar axis was found, with different slopes in different participants. The slopes of the eCAP thresholds to modiolus distance of the electrode across ears could explain up to 67% of the variability of speech understanding in these participants. We suggest that the slope of the threshold-distance function might serve as a marker for the functional state of the target neurons (spiral ganglion cells) and can be used to assess this in individual subjects.
- 28 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Open AccessThreshold-distance functions predict speech recognition with cochlear implants
Cochlear implantation shows unexplained outcome variability. Among the key factors affecting outcomes measured by speech understanding is the functional state of the auditory nerve and the amount of its degeneration due to hearing loss. In the present study we actively varied the distance of the stimulating electrodes from the modiolus (the spiral ganglion), quantified it using fluoroscopy and cone-beam computed tomography and related it to electrically-evoked compound action potentials (eCAPs) in human subjects. Stimulation was monopolar. The distance from modiolus could explain up to 91% of the variability in the thresholds of eCAPs. The threshold varied between participants. For individual electrodes of the implant in the given participant, a linear relationship between threshold (in current level) and distance from modiolar axis was found, with different slopes in different participants. The slopes of the eCAP thresholds to modiolus distance of the electrode across ears could explain up to 67% of the variability of speech understanding in these participants. We suggest that the slope of the threshold-distance function might serve as a marker for the functional state of the target neurons (spiral ganglion cells) and can be used to assess this in individual subjects.
- Open Access
- 22 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3625
A Machine Learning Model to Predict Postoperative Speech Recognition Outcomes in Cochlear Implant Recipients: Development, Validation, and Comparison with Expert Clinical Judgment
Background/Objectives: Cochlear implantation (CI) significantly enhances speech perception and quality of life in patients with severe-to-profound sensorineural hearing loss, yet outcomes vary substantially. Accurate preoperative prediction of CI outcomes remains challenging. This study aimed to develop and validate a machine learning model predicting postoperative speech recognition using a large, single-center dataset. Additionally, we compared model performance with expert clinical predictions to evaluate potential clinical utility. Methods: We retrospectively analyzed data from 2571 adult patients with postlingual hearing loss who received their cochlear implant between 2000 and 2022 at Hannover Medical School, Germany. A decision tree regression model was trained to predict monosyllabic (MS) word recognition score one to two years post-implantation using preoperative clinical variables (age, duration of deafness, preoperative MS score, pure tone average, onset type, and contralateral implantation status). Model evaluation was performed using a random data split (10%), a chronological future cohort (patients implanted after 2020), and a subset where experienced audiologists predicted outcomes for comparison. Results: The model achieved a mean absolute error (MAE) of 17.3% on the random test set and 17.8% on the chronological test set, demonstrating robust predictive performance over time. Compared to expert audiologist predictions, the model showed similar accuracy (MAE: 19.1% for the model vs. 18.9% for experts), suggesting comparable effectiveness. Conclusions: Our machine learning model reliably predicts postoperative speech outcomes and matches expert clinical predictions, highlighting its potential for supporting clinical decision-making. Future research should include external validation and prospective trials to further confirm clinical applicability.
- 22 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3625
Open AccessA Machine Learning Model to Predict Postoperative Speech Recognition Outcomes in Cochlear Implant Recipients: Development, Validation, and Comparison with Expert Clinical Judgment
Background/Objectives: Cochlear implantation (CI) significantly enhances speech perception and quality of life in patients with severe-to-profound sensorineural hearing loss, yet outcomes vary substantially. Accurate preoperative prediction of CI outcomes remains challenging. This study aimed to develop and validate a machine learning model predicting postoperative speech recognition using a large, single-center dataset. Additionally, we compared model performance with expert clinical predictions to evaluate potential clinical utility. Methods: We retrospectively analyzed data from 2571 adult patients with postlingual hearing loss who received their cochlear implant between 2000 and 2022 at Hannover Medical School, Germany. A decision tree regression model was trained to predict monosyllabic (MS) word recognition score one to two years post-implantation using preoperative clinical variables (age, duration of deafness, preoperative MS score, pure tone average, onset type, and contralateral implantation status). Model evaluation was performed using a random data split (10%), a chronological future cohort (patients implanted after 2020), and a subset where experienced audiologists predicted outcomes for comparison. Results: The model achieved a mean absolute error (MAE) of 17.3% on the random test set and 17.8% on the chronological test set, demonstrating robust predictive performance over time. Compared to expert audiologist predictions, the model showed similar accuracy (MAE: 19.1% for the model vs. 18.9% for experts), suggesting comparable effectiveness. Conclusions: Our machine learning model reliably predicts postoperative speech outcomes and matches expert clinical predictions, highlighting its potential for supporting clinical decision-making. Future research should include external validation and prospective trials to further confirm clinical applicability.
- 19 May 2023
- Published by Morressier GmbH
Influence of cochlea implant re-implantation on speech comprehension
- 19 May 2023
- Published by Morressier GmbH
Influence of cochlea implant re-implantation on speech comprehension
- Open Access
- 16 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (20) , 6090
Cochlear Implantation in Obliterated Cochlea: A Retrospective Analysis and Comparison between the IES Stiff Custom-Made Device and the Split-Array and Regular Electrodes
Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.
- 16 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (20) , 6090
Open AccessCochlear Implantation in Obliterated Cochlea: A Retrospective Analysis and Comparison between the IES Stiff Custom-Made Device and the Split-Array and Regular Electrodes
Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.
- Open Access
- 5 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (10) , 1658
Do Not Go Gentle into That Deaf Night: A Holistic Perspective on Cochlear Implant Use as Part of Healthy Aging
Research suggests that cochlear implant (CI) use in elderly people improves speech perception and health-related quality of life (HRQOL). CI provision could also prevent dementia and other comorbidities and support healthy aging. The aim of this study was (1) to prospectively investigate potential changes in HRQOL and speech perception and (2) to identify clinical action points to improve CI treatment. Participants (n = 45) were CI recipients aged 60–90 with postlingual deafness. They were divided into groups, according to age: Group 1 (n = 20) received a CI between the age of 60–70 years; group 2 (n = 25) between the age of 71–90 years. HRQOL and speech perception were assessed preoperatively, and three and twelve months postoperatively. HRQOL and speech perception increased significantly within one year postoperatively in both groups. No difference between groups was found. We conclude that CI treatment improves speech perception and HRQOL in elderly users. Improvement of the referral process for CI treatment and a holistic approach when discussing CI treatment in the elderly population could prevent auditory deprivation and the deterioration of cognitive abilities.
- 5 October 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (10) , 1658
Open AccessDo Not Go Gentle into That Deaf Night: A Holistic Perspective on Cochlear Implant Use as Part of Healthy Aging
Research suggests that cochlear implant (CI) use in elderly people improves speech perception and health-related quality of life (HRQOL). CI provision could also prevent dementia and other comorbidities and support healthy aging. The aim of this study was (1) to prospectively investigate potential changes in HRQOL and speech perception and (2) to identify clinical action points to improve CI treatment. Participants (n = 45) were CI recipients aged 60–90 with postlingual deafness. They were divided into groups, according to age: Group 1 (n = 20) received a CI between the age of 60–70 years; group 2 (n = 25) between the age of 71–90 years. HRQOL and speech perception were assessed preoperatively, and three and twelve months postoperatively. HRQOL and speech perception increased significantly within one year postoperatively in both groups. No difference between groups was found. We conclude that CI treatment improves speech perception and HRQOL in elderly users. Improvement of the referral process for CI treatment and a holistic approach when discussing CI treatment in the elderly population could prevent auditory deprivation and the deterioration of cognitive abilities.
- Open Access
- 1 September 2021
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 66 (s1) , 339-342
06-1745-B25
Article 06-1745-B25 was published on September 1, 2021 in the journal Biomedical Engineering / Biomedizinische Technik (volume 66, issue s1).
- 1 September 2021
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 66 (s1) , 339-342
Open Access06-1745-B25
Article 06-1745-B25 was published on September 1, 2021 in the journal Biomedical Engineering / Biomedizinische Technik (volume 66, issue s1).
- Open Access
- 8 January 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (1) , e0244433
A sound coding strategy based on a temporal masking model for cochlear implants
Auditory masking occurs when one sound is perceptually altered by the presence of another sound. Auditory masking in the frequency domain is known as simultaneous masking and in the time domain is known as temporal masking or non-simultaneous masking. This works presents a sound coding strategy that incorporates a temporal masking model to select the most relevant channels for stimulation in a cochlear implant (CI). A previous version of the strategy, termed psychoacoustic advanced combination encoder (PACE), only used a simultaneous masking model for the same purpose, for this reason the new strategy has been termed temporal-PACE (TPACE). We hypothesized that a sound coding strategy that focuses on stimulating the auditory nerve with pulses that are as masked as possible can improve speech intelligibility for CI users. The temporal masking model used within TPACE attenuates the simultaneous masking thresholds estimated by PACE over time. The attenuation is designed to fall exponentially with a strength determined by a single parameter, the temporal masking half-life T½. This parameter gives the time interval at which the simultaneous masking threshold is halved. The study group consisted of 24 postlingually deaf subjects with a minimum of six months experience after CI activation. A crossover design was used to compare four variants of the new temporal masking strategy TPACE (T½ ranging between 0.4 and 1.1 ms) with respect to the clinical MP3000 strategy, a commercial implementation of the PACE strategy, in two prospective, within-subject, repeated-measure experiments. The outcome measure was speech intelligibility in noise at 15 to 5 dB SNR. In two consecutive experiments, the TPACE with T½ of 0.5 ms obtained a speech performance increase of 11% and 10% with respect to the MP3000 (T½ = 0 ms), respectively. The improved speech test scores correlated with the clinical performance of the subjects: CI users with above-average outcome in their routine speech tests showed higher benefit with TPACE. It seems that the consideration of short-acting temporal masking can improve speech intelligibility in CI users. The half-live with the highest average speech perception benefit (0.5 ms) corresponds to time scales that are typical for neuronal refractory behavior.
- 8 January 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (1) , e0244433
Open AccessA sound coding strategy based on a temporal masking model for cochlear implants
Auditory masking occurs when one sound is perceptually altered by the presence of another sound. Auditory masking in the frequency domain is known as simultaneous masking and in the time domain is known as temporal masking or non-simultaneous masking. This works presents a sound coding strategy that incorporates a temporal masking model to select the most relevant channels for stimulation in a cochlear implant (CI). A previous version of the strategy, termed psychoacoustic advanced combination encoder (PACE), only used a simultaneous masking model for the same purpose, for this reason the new strategy has been termed temporal-PACE (TPACE). We hypothesized that a sound coding strategy that focuses on stimulating the auditory nerve with pulses that are as masked as possible can improve speech intelligibility for CI users. The temporal masking model used within TPACE attenuates the simultaneous masking thresholds estimated by PACE over time. The attenuation is designed to fall exponentially with a strength determined by a single parameter, the temporal masking half-life T½. This parameter gives the time interval at which the simultaneous masking threshold is halved. The study group consisted of 24 postlingually deaf subjects with a minimum of six months experience after CI activation. A crossover design was used to compare four variants of the new temporal masking strategy TPACE (T½ ranging between 0.4 and 1.1 ms) with respect to the clinical MP3000 strategy, a commercial implementation of the PACE strategy, in two prospective, within-subject, repeated-measure experiments. The outcome measure was speech intelligibility in noise at 15 to 5 dB SNR. In two consecutive experiments, the TPACE with T½ of 0.5 ms obtained a speech performance increase of 11% and 10% with respect to the MP3000 (T½ = 0 ms), respectively. The improved speech test scores correlated with the clinical performance of the subjects: CI users with above-average outcome in their routine speech tests showed higher benefit with TPACE. It seems that the consideration of short-acting temporal masking can improve speech intelligibility in CI users. The half-live with the highest average speech perception benefit (0.5 ms) corresponds to time scales that are typical for neuronal refractory behavior.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Predictive models for cochlear implant outcomes: Performance, generalizability, and the impact of cohort size
While cochlear implants have helped hundreds of thousands of individuals, it remains difficult to predict the extent to which an individual’s hearing will benefit from implantation. Several publications indicate that machine learning may improve predictive accuracy of cochlear implant outcomes compared to classical statistical methods. However, existing studies are limited in terms of model validation and evaluating factors like sample size on predictive performance. We conduct a thorough examination of machine learning approaches to predict word recognition scores (WRS) measured approximately 12 months after implantation in adults with post-lingual hearing loss. This is the largest retrospective study of cochlear implant outcomes to date, evaluating 2,489 cochlear implant recipients from three clinics. We demonstrate that while machine learning models significantly outperform linear models in prediction of WRS, their overall accuracy remains limited (mean absolute error: 17.9-21.8). The models are robust across clinical cohorts, with predictive error increasing by at most 16% when evaluated on a clinic excluded from the training set. We show that predictive improvement is unlikely to be improved by increasing sample size alone, with doubling of sample size estimated to only increasing performance by 3% on the combined dataset. Finally, we demonstrate how the current models could support clinical decision making, highlighting that subsets of individuals can be identified that have a 94% chance of improving WRS by at least 10% points after implantation, which is likely to be clinically meaningful. We discuss several implications of this analysis, focusing on the need to improve and standardize data collection.
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Open AccessPredictive models for cochlear implant outcomes: Performance, generalizability, and the impact of cohort size
While cochlear implants have helped hundreds of thousands of individuals, it remains difficult to predict the extent to which an individual’s hearing will benefit from implantation. Several publications indicate that machine learning may improve predictive accuracy of cochlear implant outcomes compared to classical statistical methods. However, existing studies are limited in terms of model validation and evaluating factors like sample size on predictive performance. We conduct a thorough examination of machine learning approaches to predict word recognition scores (WRS) measured approximately 12 months after implantation in adults with post-lingual hearing loss. This is the largest retrospective study of cochlear implant outcomes to date, evaluating 2,489 cochlear implant recipients from three clinics. We demonstrate that while machine learning models significantly outperform linear models in prediction of WRS, their overall accuracy remains limited (mean absolute error: 17.9-21.8). The models are robust across clinical cohorts, with predictive error increasing by at most 16% when evaluated on a clinic excluded from the training set. We show that predictive improvement is unlikely to be improved by increasing sample size alone, with doubling of sample size estimated to only increasing performance by 3% on the combined dataset. Finally, we demonstrate how the current models could support clinical decision making, highlighting that subsets of individuals can be identified that have a 94% chance of improving WRS by at least 10% points after implantation, which is likely to be clinically meaningful. We discuss several implications of this analysis, focusing on the need to improve and standardize data collection.
- Open Access
- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
A MultiCenter Analysis of Factors Associated with Hearing Outcome for 2,735 Adults with Cochlear Implants
While the majority of cochlear implant recipients benefit from the device, it remains difficult to estimate the degree of benefit for a specific patient prior to implantation. Using data from 2,735 cochlear-implant recipients from across three clinics, the largest retrospective study of cochlear-implant outcomes to date, we investigate the association between 21 preoperative factors and speech recognition approximately one year after implantation and explore the consistency of their effects across the three constituent datasets. We provide evidence of 17 statistically significant associations, in either univariate or multivariate analysis, including confirmation of associations for several predictive factors, which have only been examined in prior smaller studies. Despite the large sample size, a multivariate analysis shows that the variance explained by our models remains modest across the datasets ( –0.21). Finally, we report a novel statistical interaction indicating that the duration of deafness in the implanted ear has a stronger impact on hearing outcome when considered relative to a candidate’s age. Our multicenter study highlights several real-world complexities that impact the clinical translation of predictive factors for cochlear implantation outcome. We suggest several directions to overcome these challenges and further improve our ability to model patient outcomes with increased accuracy.- 1 January 2021
- Published by SAGE Publications in Trends in Hearing
- Vol. 25
Open AccessA MultiCenter Analysis of Factors Associated with Hearing Outcome for 2,735 Adults with Cochlear Implants
While the majority of cochlear implant recipients benefit from the device, it remains difficult to estimate the degree of benefit for a specific patient prior to implantation. Using data from 2,735 cochlear-implant recipients from across three clinics, the largest retrospective study of cochlear-implant outcomes to date, we investigate the association between 21 preoperative factors and speech recognition approximately one year after implantation and explore the consistency of their effects across the three constituent datasets. We provide evidence of 17 statistically significant associations, in either univariate or multivariate analysis, including confirmation of associations for several predictive factors, which have only been examined in prior smaller studies. Despite the large sample size, a multivariate analysis shows that the variance explained by our models remains modest across the datasets ( –0.21). Finally, we report a novel statistical interaction indicating that the duration of deafness in the implanted ear has a stronger impact on hearing outcome when considered relative to a candidate’s age. Our multicenter study highlights several real-world complexities that impact the clinical translation of predictive factors for cochlear implantation outcome. We suggest several directions to overcome these challenges and further improve our ability to model patient outcomes with increased accuracy.