Sefi Vernick
Research Subjects
Sefi Vernick has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Abraham Oluwafemi Ogungbile
Department of Sensing Information and Mechanical Systems Engineering, Institute of Agricultural and Biosystems Engineering, Agricultural Research Organization—Volcani Institute, Rishon LeZion, 7505101, Israel
4 shared publications - Dharanivasan Gunasekaran
Department of Sensing, Information and Mechanization Engineering, Institute of Agricultural Engineering, Volcani Institute (ARO), Rishon LeZion, 5025001, Israel
2 shared publications - Idan Ashur
Department of Sensing, Information and Mechanization Engineering, Institute of Agricultural Engineering, ARO Volcani Center, 68 Hamaccabim Rd, Rishon lezion, 5025001, Israel
2 shared publications - Anat Molad Filossof
Agro-Nanotechnology and Advanced Materials Center, The Department of Food Science, Agricultural Research Organization, The Volcani Center, Rishon LeZion 7505101, Israel
1 shared publication Dan Gilad
Mekorot, Israel National Water Company, P.O. Box 610, Eshkol site, Nof Hagalil 1710502, Israel
1 shared publication- David Taussig
The Shmunis School of Biomedicine and Cancer Research, George S. Wise Faculty of Life Sciences, Tel Aviv University, Tel Aviv, 69978, Israel; The Center for Combating Pandemics, Tel Aviv University, Tel Aviv, 69978, Israel
1 shared publication
Latest Publications
- Open Access
- 27 February 2026
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (2) , 349-360
Comparative Evaluation of Electrochemical and Fluorescent Readouts for Immunomagnetically Captured Waterborne Pathogens Using a Biochip with Bifunctional Magnetic Nanoparticles
Detection of waterborne pathogens benefits from measurement strategies that combine sensitivity with a practical workflow. We report a side-by-side metrological comparison of two orthogonal readouts measured on the same immunomagnetically captured cells using bifunctional Fe3O4 nanoparticles (MNPs) conjugated to anti-E. coli IgG and ferrocene (Fc). Under our protocol, these Fc-IgG MNPs achieved capturing efficiency up to 95% for Escherichia coli (E. coli) K12. The electrochemical readout, performed by a microfabricated chip (via differential pulse voltammetry of Fc) shows concentration-dependent signal suppression upon capture of E. coli K12, with an apparent detection limit as low as 10 cells·mL–1 and a broad dynamic range spanning 101 to 109 cells·mL–1. A complementary on-chip fluorescence readout (via Nile Red staining) provides visual corroboration and specificity support but exhibits reduced analytical sensitivity, approximately 4 orders of magnitude lower than the electrochemical approach, consistent with nanoparticle-induced quenching at lower cell counts. Across model and drinking-water matrices tested, the comparative performance trend is preserved, and the complete workflow can be completed in about 2 h from capture to readout. Taken together, these results present a comprehensive, internally consistent comparison on a single capture construct and clarify when electrochemistry versus fluorescence is fit-for-purpose in the context of immunomagnetic separation. The platform supports low-consumable testing with a reusable, unmodified electrochemical chip, is amenable to multiplexed array formats, and is readily compatible with portable potentiostats for on-site measurements.
- 27 February 2026
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (2) , 349-360
Open AccessComparative Evaluation of Electrochemical and Fluorescent Readouts for Immunomagnetically Captured Waterborne Pathogens Using a Biochip with Bifunctional Magnetic Nanoparticles
Detection of waterborne pathogens benefits from measurement strategies that combine sensitivity with a practical workflow. We report a side-by-side metrological comparison of two orthogonal readouts measured on the same immunomagnetically captured cells using bifunctional Fe3O4 nanoparticles (MNPs) conjugated to anti-E. coli IgG and ferrocene (Fc). Under our protocol, these Fc-IgG MNPs achieved capturing efficiency up to 95% for Escherichia coli (E. coli) K12. The electrochemical readout, performed by a microfabricated chip (via differential pulse voltammetry of Fc) shows concentration-dependent signal suppression upon capture of E. coli K12, with an apparent detection limit as low as 10 cells·mL–1 and a broad dynamic range spanning 101 to 109 cells·mL–1. A complementary on-chip fluorescence readout (via Nile Red staining) provides visual corroboration and specificity support but exhibits reduced analytical sensitivity, approximately 4 orders of magnitude lower than the electrochemical approach, consistent with nanoparticle-induced quenching at lower cell counts. Across model and drinking-water matrices tested, the comparative performance trend is preserved, and the complete workflow can be completed in about 2 h from capture to readout. Taken together, these results present a comprehensive, internally consistent comparison on a single capture construct and clarify when electrochemistry versus fluorescence is fit-for-purpose in the context of immunomagnetic separation. The platform supports low-consumable testing with a reusable, unmodified electrochemical chip, is amenable to multiplexed array formats, and is readily compatible with portable potentiostats for on-site measurements.
- Open Access
- 2 September 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (9)
A Comparative Study of a Multi-Method Electrochemical Biosensor for Rapid Detection of Microcystins in Treated Wastewater
Cyanotoxins, particularly Microcystins (MCs), pose significant environmental and public health risks due to their increasing prevalence in surface water. Electrochemical biosensors (ECBs) for MCs detection offers promising solution due to their simplicity, miniaturization potential, high sensitivity, and broad analytical range. This study presents a multi-method electrochemical biosensor integrating immuno-impedimetric and substrate-mediated amperometric detection on similar biochips for rapid and accurate quantification of MCs. The immuno-impedimetric sensor, based on electrochemical impedance spectroscopy, enables label-free, real-time detection with a dynamic range spanning five orders of magnitude (3 × 10⁻³ to 30 µg/L) and a limit of detection of 3 × 10⁻³ µg/L, making it suited for ultra-low concentration monitoring in environmental water samples. Complementing this, the substrate-mediated amperometric immunosensor achieves a LOD of 6.6 × 10⁻² µg/L. Detection times are under 10 minutes for the impedimetric sensor and 20 minutes for the amperometric sensor. Benchmarked against conventional ELISA in treated wastewater, both ECB methods demonstrated comparable sensitivity and enhanced reliability, meeting regulatory standards such as the WHO guideline of 1 µg/L for MC-LR in water. This dual-detection ECB offers significant advancement over traditional methods, providing sensitive, rapid, and versatile MCs monitoring in complex water matrices for proactive water quality management.
- 2 September 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (9)
Open AccessA Comparative Study of a Multi-Method Electrochemical Biosensor for Rapid Detection of Microcystins in Treated Wastewater
Cyanotoxins, particularly Microcystins (MCs), pose significant environmental and public health risks due to their increasing prevalence in surface water. Electrochemical biosensors (ECBs) for MCs detection offers promising solution due to their simplicity, miniaturization potential, high sensitivity, and broad analytical range. This study presents a multi-method electrochemical biosensor integrating immuno-impedimetric and substrate-mediated amperometric detection on similar biochips for rapid and accurate quantification of MCs. The immuno-impedimetric sensor, based on electrochemical impedance spectroscopy, enables label-free, real-time detection with a dynamic range spanning five orders of magnitude (3 × 10⁻³ to 30 µg/L) and a limit of detection of 3 × 10⁻³ µg/L, making it suited for ultra-low concentration monitoring in environmental water samples. Complementing this, the substrate-mediated amperometric immunosensor achieves a LOD of 6.6 × 10⁻² µg/L. Detection times are under 10 minutes for the impedimetric sensor and 20 minutes for the amperometric sensor. Benchmarked against conventional ELISA in treated wastewater, both ECB methods demonstrated comparable sensitivity and enhanced reliability, meeting regulatory standards such as the WHO guideline of 1 µg/L for MC-LR in water. This dual-detection ECB offers significant advancement over traditional methods, providing sensitive, rapid, and versatile MCs monitoring in complex water matrices for proactive water quality management.
- 20 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 257, 116314
A dual-channel electrochemical biosensor enables concurrent detection of pathogens and antibiotic resistance
- 20 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 257, 116314
A dual-channel electrochemical biosensor enables concurrent detection of pathogens and antibiotic resistance
- Open Access
- 12 January 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (1) , 36
Electrochemical Detection of Waterborne Bacteria Using Bi-Functional Magnetic Nanoparticle Conjugates
Detection of microbial contamination in water is imperative to ensure water quality. We have developed an electrochemical method for the detection of E. coli using bi-functional magnetic nanoparticle (MNP) conjugates. The bi-functional MNP conjugates were prepared by terminal-specific conjugation of anti-E. coli IgG antibody and the electroactive marker ferrocene. The bi-functional MNP conjugate possesses both E. coli-specific binding and electroactive properties, which were studied in detail. The conjugation efficiency of ferrocene and IgG antibodies with amine-functionalized MNPs was investigated. Square-wave voltammetry enabled the detection of E. coli concentrations ranging from 101–107 cells/mL in a dose-dependent manner, as ferrocene-specific current signals were inversely dependent on E. coli concentrations, completely suppressed at concentrations higher than 107 cells/mL. The developed electrochemical method is highly sensitive (10 cells/mL) and, coupled to magnetic separation, provides specific signals within 1h. Overall, the bi-functional conjugates serve as ideal candidates for electrochemical detection of waterborne bacteria. This approach can be applied for the detection of other bacteria and viruses.
- 12 January 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (1) , 36
Open AccessElectrochemical Detection of Waterborne Bacteria Using Bi-Functional Magnetic Nanoparticle Conjugates
Detection of microbial contamination in water is imperative to ensure water quality. We have developed an electrochemical method for the detection of E. coli using bi-functional magnetic nanoparticle (MNP) conjugates. The bi-functional MNP conjugates were prepared by terminal-specific conjugation of anti-E. coli IgG antibody and the electroactive marker ferrocene. The bi-functional MNP conjugate possesses both E. coli-specific binding and electroactive properties, which were studied in detail. The conjugation efficiency of ferrocene and IgG antibodies with amine-functionalized MNPs was investigated. Square-wave voltammetry enabled the detection of E. coli concentrations ranging from 101–107 cells/mL in a dose-dependent manner, as ferrocene-specific current signals were inversely dependent on E. coli concentrations, completely suppressed at concentrations higher than 107 cells/mL. The developed electrochemical method is highly sensitive (10 cells/mL) and, coupled to magnetic separation, provides specific signals within 1h. Overall, the bi-functional conjugates serve as ideal candidates for electrochemical detection of waterborne bacteria. This approach can be applied for the detection of other bacteria and viruses.
- Open Access
In Situ Grafting of Silica Nanoparticle Precursors with Covalently Attached Bioactive Agents to Form PVA-Based Materials for Sustainable Active Packaging
Sustainable antibacterial–antioxidant films were prepared using in situ graftings of silica nanoparticle (SNP) precursors with covalently attached bioactive agents benzoic acid (ba) or curcumin (cur) on polyvinyl alcohol (PVA). The modified PVA-SNP, PVA-SNP-ba and PVA-SNP-cur films were characterized using spectroscopic, physicochemical and microscopic methods. The prepared films showed excellent antibacterial and antioxidant activity, and increased hydrophobicity providing protection from undesired moisture. The PVA-SNP-ba films completely prevented the growth of the foodborne human pathogen Listeria innocua, whereas PVA-SNP-cur resulted in a 2.5 log reduction of this bacteria. The PVA-SNP-cur and PVA-SNP-ba films showed high antioxidant activity of 15.9 and 14.7 Mm/g TEAC, respectively. The described approach can serve as a generic platform for the formation of PVA-based packaging materials with tailor-made activity tuned by active substituents on silica precursors. Application of such biodegradable films bearing safe bioactive agents can be particularly valuable for advanced sustainable packaging materials in food and medicine.
Open AccessIn Situ Grafting of Silica Nanoparticle Precursors with Covalently Attached Bioactive Agents to Form PVA-Based Materials for Sustainable Active Packaging
Sustainable antibacterial–antioxidant films were prepared using in situ graftings of silica nanoparticle (SNP) precursors with covalently attached bioactive agents benzoic acid (ba) or curcumin (cur) on polyvinyl alcohol (PVA). The modified PVA-SNP, PVA-SNP-ba and PVA-SNP-cur films were characterized using spectroscopic, physicochemical and microscopic methods. The prepared films showed excellent antibacterial and antioxidant activity, and increased hydrophobicity providing protection from undesired moisture. The PVA-SNP-ba films completely prevented the growth of the foodborne human pathogen Listeria innocua, whereas PVA-SNP-cur resulted in a 2.5 log reduction of this bacteria. The PVA-SNP-cur and PVA-SNP-ba films showed high antioxidant activity of 15.9 and 14.7 Mm/g TEAC, respectively. The described approach can serve as a generic platform for the formation of PVA-based packaging materials with tailor-made activity tuned by active substituents on silica precursors. Application of such biodegradable films bearing safe bioactive agents can be particularly valuable for advanced sustainable packaging materials in food and medicine.
- Open Access
- 17 March 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (3) , 26
The Emergence of Insect Odorant Receptor-Based Biosensors
The olfactory receptor neurons of insects and vertebrates are gated by odorant receptor (OR) proteins of which several members have been shown to exhibit remarkable sensitivity and selectivity towards volatile organic compounds of significant importance in the fields of medicine, agriculture and public health. Insect ORs offer intrinsic amplification where a single binding event is transduced into a measurable ionic current. Consequently, insect ORs have great potential as biorecognition elements in many sensor configurations. However, integrating these sensing components onto electronic transducers for the development of biosensors has been marginal due to several drawbacks, including their lipophilic nature, signal transduction mechanism and the limited number of known cognate receptor-ligand pairs. We review the current state of research in this emerging field and highlight the use of a group of indole-sensitive ORs (indolORs) from unexpected sources for the development of biosensors.
- 17 March 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (3) , 26
Open AccessThe Emergence of Insect Odorant Receptor-Based Biosensors
The olfactory receptor neurons of insects and vertebrates are gated by odorant receptor (OR) proteins of which several members have been shown to exhibit remarkable sensitivity and selectivity towards volatile organic compounds of significant importance in the fields of medicine, agriculture and public health. Insect ORs offer intrinsic amplification where a single binding event is transduced into a measurable ionic current. Consequently, insect ORs have great potential as biorecognition elements in many sensor configurations. However, integrating these sensing components onto electronic transducers for the development of biosensors has been marginal due to several drawbacks, including their lipophilic nature, signal transduction mechanism and the limited number of known cognate receptor-ligand pairs. We review the current state of research in this emerging field and highlight the use of a group of indole-sensitive ORs (indolORs) from unexpected sources for the development of biosensors.