Zhong-Xian Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhong-Xian Li has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
Yanchao Shi
13 shared publicationsYang Ding
Tianjin Univ
12 shared publicationsBo Zhao
6 shared publicationsHuishen Zhang
6 shared publications- Yundong Shi
School of Civil Engineering Tianjin University Tianjin China
6 shared publications - Longhe Xu
Beijing Jiaotong University
5 shared publications
Latest Publications
- 1 December 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 152 (12)
Shaking Table Tests of a Layered Isolation System with High-Horizontal-Resistance Vertical Isolators for Large Hub Buildings
To mitigate the horizontal seismic responses of the substructure and the 3D seismic responses of the long-span spatial roof structure in a large hub building, an innovative layered isolation system has been proposed. This system entails the installation of traditional horizontal isolators at the base of the substructure and high-horizontal-resistance vertical isolators at the supports of the roof structure. To verify the system’s isolation performance, a series of shaking table tests of a 1/12-length-scaled simplified model with a latticed shell as the roof structure and concrete frames as the substructure were carried out using friction pendulum bearings and recently proposed vertical isolators. Four distinct model configurations, including the nonisolated, vertically isolated, horizontally isolated, and layered isolated scenarios, were tested. The asynchronous behavior of the vertical isolators in the layered-isolated model is investigated. The results show that the layered isolation is as effective as the horizontal isolation in reducing the seismic responses of the substructure and the seismic responses of the roof structure induced by the horizontal ground motions. It is also as effective as the vertical isolation in reducing the seismic responses of the roof structure induced by the vertical ground motions and generally provides 30% higher isolation ratios than the horizontal isolation for the seismic responses of the roof structure affected by horizontal and vertical ground motions. The horizontal seismic effect considering the frictional nature of the vertical isolators is found to mainly cause the asynchronous behavior of the vertical isolators in the layered-isolated model.
- 1 December 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 152 (12)
Shaking Table Tests of a Layered Isolation System with High-Horizontal-Resistance Vertical Isolators for Large Hub Buildings
To mitigate the horizontal seismic responses of the substructure and the 3D seismic responses of the long-span spatial roof structure in a large hub building, an innovative layered isolation system has been proposed. This system entails the installation of traditional horizontal isolators at the base of the substructure and high-horizontal-resistance vertical isolators at the supports of the roof structure. To verify the system’s isolation performance, a series of shaking table tests of a 1/12-length-scaled simplified model with a latticed shell as the roof structure and concrete frames as the substructure were carried out using friction pendulum bearings and recently proposed vertical isolators. Four distinct model configurations, including the nonisolated, vertically isolated, horizontally isolated, and layered isolated scenarios, were tested. The asynchronous behavior of the vertical isolators in the layered-isolated model is investigated. The results show that the layered isolation is as effective as the horizontal isolation in reducing the seismic responses of the substructure and the seismic responses of the roof structure induced by the horizontal ground motions. It is also as effective as the vertical isolation in reducing the seismic responses of the roof structure induced by the vertical ground motions and generally provides 30% higher isolation ratios than the horizontal isolation for the seismic responses of the roof structure affected by horizontal and vertical ground motions. The horizontal seismic effect considering the frictional nature of the vertical isolators is found to mainly cause the asynchronous behavior of the vertical isolators in the layered-isolated model.
- 19 August 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 541
Experimental study on the dynamic behaviour of concrete at high temperatures and after cooling
- 19 August 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 541
Experimental study on the dynamic behaviour of concrete at high temperatures and after cooling
- Open Access
- 21 May 2026
- Published by Elsevier in SSRN Electronic Journal
Comparative experimental study on dynamic behaviour of concrete at high temperatures and after cooling
Concrete structures might be subject to both fire and explosion hazards during their service life. The dynamic properties of concrete at high temperatures and after cooling may differ due to the formation of additional shrinkage cracks during cooling. Therefore, a comparative study on the dynamic behaviour of concrete at high temperature and after cooling down is necessary to predict the dynamic response of structures subjected to fire and explosion loads more precisely. A series of Split Hopkinson Pressure Bar (SHPB) dynamic tests were conducted to comparatively investigate the dynamic compressive and splitting tensile behaviour of concrete at and after high temperatures. The experimental results show that, compared with specimens tested at high temperatures, those tested after high temperatures exhibit more severe fragmentation, indicating that concrete becomes more brittle after cooling. On the other hand, analysis of energy evolution shows that concrete demonstrates higher toughness at high temperatures than after cooling. At the same strain rate and temperature, both the peak stress and corresponding strain of specimens tested at high temperatures are higher than those after cooling. The strain rate effects on the strength, the strain at peak stress, and the secant elastic modulus are more pronounced at high temperatures than those after cooling.
- 21 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessComparative experimental study on dynamic behaviour of concrete at high temperatures and after cooling
Concrete structures might be subject to both fire and explosion hazards during their service life. The dynamic properties of concrete at high temperatures and after cooling may differ due to the formation of additional shrinkage cracks during cooling. Therefore, a comparative study on the dynamic behaviour of concrete at high temperature and after cooling down is necessary to predict the dynamic response of structures subjected to fire and explosion loads more precisely. A series of Split Hopkinson Pressure Bar (SHPB) dynamic tests were conducted to comparatively investigate the dynamic compressive and splitting tensile behaviour of concrete at and after high temperatures. The experimental results show that, compared with specimens tested at high temperatures, those tested after high temperatures exhibit more severe fragmentation, indicating that concrete becomes more brittle after cooling. On the other hand, analysis of energy evolution shows that concrete demonstrates higher toughness at high temperatures than after cooling. At the same strain rate and temperature, both the peak stress and corresponding strain of specimens tested at high temperatures are higher than those after cooling. The strain rate effects on the strength, the strain at peak stress, and the secant elastic modulus are more pronounced at high temperatures than those after cooling.
- 16 January 2026
- Published by Elsevier in Engineering Structures
- Vol. 352
Underwater shaking table test on the constraint boundary effect at the top of the bridge pier on the waterpier interaction
- 16 January 2026
- Published by Elsevier in Engineering Structures
- Vol. 352
Underwater shaking table test on the constraint boundary effect at the top of the bridge pier on the waterpier interaction