Latest Publications

  • Reinforcement of ancient floors by timber–concrete composite systems with collar connector

    by Beatrice Faggiano, Giacomo Iovane, Anna Marzo, Maria Rosaria Grippa, Luis Calado, Federico M. Mazzolani

    Timber–concrete composite (TCC) systems have been successfully used in built heritage. They provide an efficient solution for improving the seismic response of masonry buildings in which timber floors are generally used. TCCs commonly consist of a thin concrete slab connected to the timber beams by connectors. The paper focuses on a steel collar connector, appropriately conceived for surrounding the timber beam, avoiding any drilling into the wood. It is composed of parts bolted at appropriate wings, with the superior one or purposely welded studs working as connectors. A rubber layer interposed between the collar and beam can both reduce damage to the beam surface and ensure the adaptability of the system to irregular surfaces if applied to existing beams. Friction at the wood–(rubber)–steel surface is guaranteed by bolt tightening. This paper describes the experimental and numerical research activity carried out. Monotonic push-out tests were performed on different types of collars, which allowed the evaluation of the system behaviour and failure modes, with the aim of system optimisation. Bending tests on either timber–concrete beams or a full-scale floor equipped with collar connectors were also performed. An application of the TCC system with collar connectors to a historical timber floor is briefly described.


  • The Royal Palace of Naples: Diagnosis, Assessment and Structural Restoration of Complex Roofing Timber Structures

    by Beatrice Faggiano, Maria Rosaria Grippa, Federico M. Mazzolani

    The paper presents an overview on the timber structures of the Royal Palace of Naples. Focusing on the roofs of the Historical Apartment, located at the second level of the palace, different structural typologies are illustrated. The structural identification was achieved starting from an extensive in situ survey, aimed at assessing materials, conservation state, geometries and static schemes. Therefore 3D FEM models of the study systems as whole were set up and the structural analyses carried out, allowing to catch the weaknesses in terms of strength and deformation capacities; the safety checks were performed according to Eurocode 5 provisions. Finally, on the basis of the acquired knowledge, the appropriate retrofitting techniques were suggested [1, . In particular, with reference to the Diplomatic Hall (II), details of the realized restoration interventions, based on mixed technologies, are presented [.


  • Bending Test on Composite Timber-Steel-Concrete Floor Equipped with Innovative Collar Connectors

    by A. Marzo, Maria Rosaria Grippa, Beatrice Faggiano, Federico M. Mazzolani

    In this paper a full scale monotonic static bending test on a composite timber-steel-concrete floor, equipped with innovative “collar” connectors, is illustrated. In particular, the specimen consists of two beams, made of ancient chestnut, connected to the concrete reinforced slab by means of purposely fitted upside wings of steel collars astride the beams themselves. The test is part of a comprehensive research activity, aiming at the evaluation and optimization of the collar connection device, developed within the European project PROHITECH (“Earthquake Protection of Historical Buildings by Reversible Mixed Technology”, 2004-2008).