Fengyan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fengyan Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bi Zhang
State Key Laboratory of Robotics and Intelligent Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
1 shared publication - Dan Ye
Northeastern University
1 shared publication - Daohui Zhang
Chinese Academy of Sciences
1 shared publication - Jianda Han
Nankai University
1 shared publication - Xingang Zhao
Chinese Academy of Sciences
1 shared publication - Ziyou Li
State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China and Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China and University of Chinese Academy of Sciences, Beijing 100049, China
1 shared publication
Latest Publications
- Open Access
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 47433-47444
A Temporally Smoothed MLP Regression Scheme for Continuous Knee/Ankle Angles Estimation by Using Multi-Channel sEMG
With coexisting-cooperative-cognitive robots gradually appearing in daily life, an instinct and efficient human-robot interaction (HRI) is becoming more and more challenging and necessary. Surface electromyography (sEMG) signals, as one of mainstream manners of the interactions, are employed to predict human intentions. In this paper, to provide natural assistance for standing up and sitting down, sEMG signals acquired from active muscles of one’s lower limb are utilized to predict continuous movements. A temporally smoothed multilayer perceptron (MLP) regression scheme is proposed for continuous knee/ankle angles estimation by multi-channel sEMG signals. After correlation analyses of sEMG signals and movements, a series of linear and nonlinear regression models are trained to decode human intentions from pre-processed sEMG. Furthermore, to remove out local fluctuations of direct mappings, temporally smoothed techniques are further implemented as post-processings. In the experiments of standing up and sitting down, extensive results of ten healthy subjects show that a three-layer MLP with the Savitzky-Golay filter achieves the best performance on the mean squared error (MSE, testing: 59.58) and the R2 score (R2, testing: 0.948). The proposed regression scheme is compared with other methods and is also verified by measurements of a high-precision visual motion capture system.
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 47433-47444
Open AccessA Temporally Smoothed MLP Regression Scheme for Continuous Knee/Ankle Angles Estimation by Using Multi-Channel sEMG
With coexisting-cooperative-cognitive robots gradually appearing in daily life, an instinct and efficient human-robot interaction (HRI) is becoming more and more challenging and necessary. Surface electromyography (sEMG) signals, as one of mainstream manners of the interactions, are employed to predict human intentions. In this paper, to provide natural assistance for standing up and sitting down, sEMG signals acquired from active muscles of one’s lower limb are utilized to predict continuous movements. A temporally smoothed multilayer perceptron (MLP) regression scheme is proposed for continuous knee/ankle angles estimation by multi-channel sEMG signals. After correlation analyses of sEMG signals and movements, a series of linear and nonlinear regression models are trained to decode human intentions from pre-processed sEMG. Furthermore, to remove out local fluctuations of direct mappings, temporally smoothed techniques are further implemented as post-processings. In the experiments of standing up and sitting down, extensive results of ten healthy subjects show that a three-layer MLP with the Savitzky-Golay filter achieves the best performance on the mean squared error (MSE, testing: 59.58) and the R2 score (R2, testing: 0.948). The proposed regression scheme is compared with other methods and is also verified by measurements of a high-precision visual motion capture system.