Robert H. Sherrier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert H. Sherrier has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Andrew James Del Gaizo
Moffitt Cancer Center, Tampa, FL, United States
1 shared publication - Armin Ansari
Atlanta, GA, United States of America
1 shared publication Charles E. Chambers
1 shared publication- David C. Spelic1 shared publication
- Donald L. Miller
U.S. Food and Drug Administration, Silver Spring, Maryland
1 shared publication Donald P. Frush
1 shared publication
Latest Publications
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (5) , e240067
Deep Learning to Detect Intracranial Hemorrhage in a National Teleradiology Program and the Impact on Interpretation Time
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. The diagnostic performance of an artificial intelligence (AI) clinical decision support (CDS) solution for acute intracranial hemorrhage (ICH) detection was assessed in a large teleradiology practice. The impact on radiologist read times and system efficiency was also quantified. A total of 61,704 consecutive noncontrast head CTs (NCHCT) were retrospectively evaluated. System performance was calculated along with mean and median read time values for NCHCT pre-AI (baseline; August 2021-May 2022) and post-AI (January 2023-February 2024). The AI solution had a sensitivity of 75.6%, specificity of 92.1%, accuracy of 91.7%, prevalence of 2.70%, and positive predictive value of 21.1%. Of the 56,745 post-AI NCHCT with no bleed identified by a radiologist, examinations falsely flagged as suspected ICH by the AI solution (n = 4,464) took 9min40sec on average/8min7sec median to interpret as compared with 8min25sec average/6min48ec median for unremarkable NCHCT pre-AI (n = 49,007) (P < .001) and 8min38sec average/6min53sec median post-AI when ICH was not suspected by the AI solution (n = 52,281) (P < .001). NCHCT with no bleed identified by the AI but reported as positive for ICH by the radiologist (n = 384) took 14min23sec on average/13min35sec median to interpret as compared with a read time of 13min34sec mean/12min30sec median for NCHCT correctly reported as a bleed by the AI (n = 1192) (P = .04). With lengthened read times for falsely flagged examinations, system inefficiencies may outweigh the potential benefits of using the tool in a high volume, low prevalence environment. ©RSNA, 2024.
- 1 September 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 6 (5) , e240067
Deep Learning to Detect Intracranial Hemorrhage in a National Teleradiology Program and the Impact on Interpretation Time
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. The diagnostic performance of an artificial intelligence (AI) clinical decision support (CDS) solution for acute intracranial hemorrhage (ICH) detection was assessed in a large teleradiology practice. The impact on radiologist read times and system efficiency was also quantified. A total of 61,704 consecutive noncontrast head CTs (NCHCT) were retrospectively evaluated. System performance was calculated along with mean and median read time values for NCHCT pre-AI (baseline; August 2021-May 2022) and post-AI (January 2023-February 2024). The AI solution had a sensitivity of 75.6%, specificity of 92.1%, accuracy of 91.7%, prevalence of 2.70%, and positive predictive value of 21.1%. Of the 56,745 post-AI NCHCT with no bleed identified by a radiologist, examinations falsely flagged as suspected ICH by the AI solution (n = 4,464) took 9min40sec on average/8min7sec median to interpret as compared with 8min25sec average/6min48ec median for unremarkable NCHCT pre-AI (n = 49,007) (P < .001) and 8min38sec average/6min53sec median post-AI when ICH was not suspected by the AI solution (n = 52,281) (P < .001). NCHCT with no bleed identified by the AI but reported as positive for ICH by the radiologist (n = 384) took 14min23sec on average/13min35sec median to interpret as compared with a read time of 13min34sec mean/12min30sec median for NCHCT correctly reported as a bleed by the AI (n = 1192) (P = .04). With lengthened read times for falsely flagged examinations, system inefficiencies may outweigh the potential benefits of using the tool in a high volume, low prevalence environment. ©RSNA, 2024.
- Top Cited Papers
- 17 March 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 295 (2) , 418-427
Patient Exposure from Radiologic and Nuclear Medicine Procedures in the United States: Procedure Volume and Effective Dose for the Period 2006–2016
In contrast to the six-fold rise in medical radiation exposure that occurred from 1980 to 2006 in the United States, per capita radiation exposure to the population decreased by 20% between 2006 an... Background Comprehensive assessments of the frequency and associated doses from radiologic and nuclear medicine procedures are rarely conducted. The use of these procedures and the population-based...
- 17 March 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 295 (2) , 418-427
Top Cited PapersPatient Exposure from Radiologic and Nuclear Medicine Procedures in the United States: Procedure Volume and Effective Dose for the Period 2006–2016
In contrast to the six-fold rise in medical radiation exposure that occurred from 1980 to 2006 in the United States, per capita radiation exposure to the population decreased by 20% between 2006 an... Background Comprehensive assessments of the frequency and associated doses from radiologic and nuclear medicine procedures are rarely conducted. The use of these procedures and the population-based...