DMDavide Maria Mocellin

Davide Maria Mocellin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Davide Maria Mocellin has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    [18F]-Fludeoxyglucose Positron Emission Tomography/Computed Tomography with Radiomics Analysis in Patients Undergoing Aortic In-Situ Reconstruction with Cryopreserved Allografts

    by Raffaella Berchiolli, Lorenzo Torri, Giulia Bertagna, Francesco Canovaro, Roberta Zanca, Francesco Bartoli, Davide Maria Mocellin, Mauro Ferrari, Paola Anna Erba, Nicola Troisi

    Background: The aim of this study was to evaluate the effectiveness of positron emission tomography/computed tomography with [18F]-fludeoxyglucose (FDG-PET/CT) and radiomics analysis in detecting differences between the native aorta and the abdominal aortic allograft after the total eradication of infection in patients undergoing infected graft removal and in situ reconstruction with cryopreserved allografts. Methods: Between January 2008 and December 2018, 56 vascular reconstructions with allografts have been performed at our department. The present series included 12 patients undergoing abdominal aortic in situ reconstruction with cryopreserved allografts. During the follow-up, all patients underwent a total-body [18F]FDG PET/CT with subsequent radiomics analysis. In all patients, a comparative analysis between the data extracted from native aorta and cryopreserved graft for each patient was performed. Results: All patients were male with a mean age of 72.8 years (range 63–84). Mean duration of follow-up was 51.3 months (range 3–120). During the follow-up, 2 patients (16.7%) needed a redo allograft-related surgical intervention. Overall, the rate of allograft dilatation was 33.3%. No patient had a redo infection during the follow-up. Radiomics analysis showed a different signature of implanted allograft and native aorta. Comparative analysis between the native aortas and cryopreserved allografts (dilated or not) showed several statistical differences for many texture features. Conclusions: The higher metabolic activity of allografts could indicate a state of immune-mediated degeneration. This theory should be proven with prospective, multicentric studies with larger sample sizes.


  • Open Access

    Correction to: An unusual cause of failure in Zenith Alpha Abdominal endograft

    by Rafaella N. Berchiolli, Michele Marconi, Irene Bargellini, Giulia Bertagna, Daniele Adami, Davide M. Mocellin, Roberto Cioni, Mauro Ferrari, Nicola Troisi

  • Open Access

    An unusual cause of failure in Zenith Alpha Abdominal endograft

    by Raffaella N. Berchiolli, Michele Marconi, Irene Bargellini, Giulia Bertagna, Daniele Adami, Davide M. Mocellin, Roberto Cioni, Mauro Ferrari, Nicola Troisi

    Background: Graft disruption is an unusual complication of the endovascular abdominal aortic aneurysm repair (EVAR). Case presentation: A 71-year-old man underwent standard EVAR with Zenith Alpha Abdominal endograft. Follow-up examinations revealed an initial significant sac shrinkage. At 24 months, duplex ultrasound (DUS) scan and computed tomography showed increase of the sac diameter associated with complete disconnection of the suprarenal stent-graft from the main body without evidence of endoleak. A standard relining with a thoracic endograft was performed between the suprarenal stent and the main body of the previous graft. At 6 months DUS revealed sac shrinkage. Conclusions: This report demonstrates an uncommon cause of endograft failure with suprarenal stent disconnection from main body and highlights the need for continuous follow-up in patients undergoing EVAR.


  • Open Access

    A case report of multisite arterial thrombosis in a patient with coronavirus disease 2019 (COVID-19)

    by Marco Angelillis, Marco De Carlo, Andrea Christou, Michele Marconi, Davide M Mocellin, Paolo Caravelli, Raffaele De Caterina, Anna S Petronio

    Background: A systemic coagulation dysfunction has been associated with COVID-19. In this case report, we describe a COVID-19-positive patient with multisite arterial thrombosis, presenting with acute limb ischaemia and concomitant ST-elevation myocardial infarction and oligo-symptomatic lung disease. Case summary: An 83-year-old lady with history of hypertension and chronic kidney disease presented to the Emergency Department with acute-onset left leg pain, pulselessness, and partial loss of motor function. Acute limb ischaemia was diagnosed. At the same time, a routine ECG showed ST-segment elevation, diagnostic for inferior myocardial infarction. On admission, a nasopharyngeal swab was performed to assess the presence of SARS-CoV-2, as per hospital protocol during the current COVID-19 pandemic. A total-body CT angiography was performed to investigate the cause of acute limb ischaemia and to rule out aortic dissection; the examination showed a total occlusion of the left common iliac artery and a non-obstructive thrombosis of a subsegmental pulmonary artery branch in the right basal lobe. Lung CT scan confirmed a typical pattern of interstitial COVID-19 pneumonia. Coronary angiography showed a thrombotic occlusion of the proximal segment of the right coronary artery. Percutaneous coronary intervention was performed, with manual thrombectomy, followed by deployment of two stents. The patient was subsequently transferred to the operating room, where a Fogarty thrombectomy was performed. The patient was then admitted to the COVID area of our hospital. Seven hours later, the swab returned positive for COVID-19. Discussion: COVID-19 can have an atypical presentation with thrombosis at multiple sites.


  • Open Access

    Novel EM Guided Endovascular Instrumentation for In Situ Endograft Fenestration

    by S. Condino, R. Piazza, R. M. Viglialoro, D. M. Mocellin, G. Turini, R. N. Berchiolli, F. Micheletti, F. Rossi, R. Pini, V. Ferrari, et al.

    Objective: This work aims at providing novel endovascular instrumentation to overcome current technical limitations of in situ endograft fenestration including challenges in targeting the fenestration site under fluoroscopic control and supplying mechanical support during endograft perforation. Technology: Novel electromagnetically trackable instruments were developed to facilitate the navigation of the fenestration device and its stabilization at the target site. In vitro trials were performed to preliminary evaluate the proposed instrumentation for the antegrade in situ fenestration of an aortic endograft, using a laser guidewire designed ad hoc and the sharp-end of a commercial endovascular guidewire. Results: In situ fenestration was successfully performed in 22 trials. A total of two laser tools were employed since an over-bending of laser guidewire tip, due to its manufacturing, caused the damage of the sensor in the first device used. Conclusions: Preliminary in vitro trials demonstrate the feasibility of the proposed instrumentation which could widespread the procedure for in situ fenestration. The results obtained should be validated performing animal studies. Clinical Impact: The proposed instrumentation has the potential to expand indications for standard endovascular aneurysm repair to cases of acute syndromes.


  • Ruptured Mycotic Aneurysm After Intravesical Instillation for Bladder Tumor

    by Raffaella Berchiolli, Davide M. Mocellin, Michele Marconi, Francesca Tomei, Irene Bargellini, Roberta Zanca, Paola Erba, Mauro Ferrari


  • Hand-assisted laparoscopic surgery versus endovascular repair in abdominal aortic aneurysm treatment

    by Raffaella Berchiolli, Francesca Tomei, Michele Marconi, Davide Maria Mocellin, Riccardo Morganti, Marta Mari, Daniele Adami, Mauro Ferrari


  • Hybrid procedures and femoral endarterectomy in diabetic patients

    by R. N. Berchiolli, M. Marconi, D. M. Mocellin, D. Adami, M. Ferrari

    OBJECTIVE: The aim of the study is to evaluate the safety and effectiveness of common femoral endarterectomy (CFE) in critical limb ischemia (CLI) associated with proximal and distal endovascular (EV) revascularization in diabetic (type 1 and type 2) and non-diabetic patients. PATIENTS AND METHODS: We analyzed patients from January 2008 to December 2011 who underwent one-staged hybrid procedures. Patients were divided into three groups: group 1 = EV reconstruction proximal to the CFE. group 2 = EV procedures distal to the CFE. group 3 = both proximal and distal EV procedures. Patients were evaluated at 6 and 36 months after the procedures, and the mean follow-up was 42 +/- 20.3 months. RESULTS: A total of 43 (79% men; aged 74.4 +/- 8.6 years) out of 635 (5.5%) patients operated for CLI fulfilled the inclusion criteria; 23 (53.5%) had type 1 or type 2 diabetes mellitus (DM). DM patients were younger than controls (p = 0.048). The patient distribution was 14 in Group 1 (32.5%), 24 in Group 2 (55.8%) and 5 in Group 3 (11.7%). CFE was successful in all cases, while associated EV procedures were successful in 90.7% of patients. Peri-operative morbidity and mortality were 11.6% and 2.3%, respectively. Survival rates at 6 and 36 months were 93% and 71.9%, respectively. Three patients (6.98%) underwent a major amputation. The cumulative limb salvage was 95.2% at 6 months and 92.1% at 36 months. No recurrent CFE stenosis was observed. No differences in survival. amputation or patency rates emerged between DM and non-DM patients or among the three EV revascularizat ion groups. CONCLUSIONS: Hybrid procedures are safe and effective both in CLI patients with or without DM, and they should betaken into consideration whenever indications are present.


  • Open Surgical Management of Hypogastric Artery during Aortic Surgery: Ligate or Not Ligate?

    by Michele Marconi, Sabrina Ceragioli, Davide M. Mocellin, Aldo Alberti, Francesca Tomei, Daniele Adami, Raffaella N. Berchiolli, Mauro Ferrari