Iain D. C. Tullis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Iain D. C. Tullis has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Borivoj Vojnovic
University of Oxford
4 shared publications - Kristoffer Petersson
Department of Oncology University of Oxford Oxford UK
4 shared publications - Paul Richard Barber
Comprehensive Cancer Centre, King's College London, London, UK
3 shared publications Adam Lambert
Nuffield Department of Surgical Sciences, University of Oxford, Headington, Oxford, UK
2 shared publications- Alastair D. Lamb
Centre for Cancer Evolution, Barts Cancer Institute, Queen Mary University of London, UK Department of Urology, Guy s and St Thomas NHS Foundation Trust, UK
2 shared publications Borivoj Vojnovic
Department of Oncology, University of Oxford, UK
2 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06001
Design and performance evaluation of a novel hybrid ionisation chamber and transmission calorimeter for dose rate independent beam monitoring in UHDR-RT
Background . Ultra-High Dose Rate Radiotherapy (UHDR-RT) is an emerging cancer treatment that delivers radiation at dose rates exceeding 40 Gy/s. While UHDR-RT offers potential therapeutic benefits, accurate dosimetry presents significant challenges. Ionisation chambers, the standard for clinical dosimetry as reference and monitor dosimeters, experience significant ion recombination at high dose rates, reducing measurement accuracy and increasing uncertainty when corrections are applied. In contrast, calorimeters are dose rate independent and potentially more reliable for accurate UHDR-RT dosimetry. However, their slow thermal response limits their use in dynamic beam monitoring. Purpose. This study investigates whether a hybrid dosimeter, combining an ionisation chamber and two transmission calorimeters, can effectively provide dose-rate independent beam monitoring for both UHDR-RT and conventional radiotherapy (CONV-RT). The goal is to leverage the fast response of ionisation chambers for routine use, while maintaining the dose rate independence of calorimetry for periodic calibrations, to develop a prototype dose rate independent beam monitor. Methods. The hybrid dosimeter was designed and evaluated using the finite element modelling software, COMSOL, to assess the interactions between the ionisation and calorimeter components. Unwanted electrical and thermal effects were studied, including their impact on electric field distribution, charge collection efficiency, and self-heating effects on calorimetry. After construction, the device was tested at the FLASH Core Facility, University of Oxford, in a 6 MeV UHDR-RT beam. Experimental investigations were conducted under various beam conditions to evaluate performance. Results. The hybrid dosimeter demonstrated a linear response in both calorimeter cores and the ionisation chamber. Minimal electrical interference was observed in the proximal calorimeter core due to the ionisation process, though this effect was deemed negligible. The ion collection efficiency was measured to be approximately 3% during the highest dose delivery of 6 Gy/pulse (5.4 MGy/s instantaneous dose rate). A Jaffé plot method derived ion recombination factor for a 2 Gy/pulse (1.8 MGy/s instantaneous dose rate) measurement was determined to be 7.84 ± 2.35 ( k = 1), with a calorimeter derived correction determined to be at least 5.22 ± 0.49 ( k = 1). Conclusions. This study successfully demonstrates the feasibility of combining ionisation and calorimetry into a single hybrid dosimeter. The device offers the potential for online beam monitoring with dose rate independence, making it a promising candidate for UHDR-RT dosimetry and further development for clinical use.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06001
Open AccessDesign and performance evaluation of a novel hybrid ionisation chamber and transmission calorimeter for dose rate independent beam monitoring in UHDR-RT
Background . Ultra-High Dose Rate Radiotherapy (UHDR-RT) is an emerging cancer treatment that delivers radiation at dose rates exceeding 40 Gy/s. While UHDR-RT offers potential therapeutic benefits, accurate dosimetry presents significant challenges. Ionisation chambers, the standard for clinical dosimetry as reference and monitor dosimeters, experience significant ion recombination at high dose rates, reducing measurement accuracy and increasing uncertainty when corrections are applied. In contrast, calorimeters are dose rate independent and potentially more reliable for accurate UHDR-RT dosimetry. However, their slow thermal response limits their use in dynamic beam monitoring. Purpose. This study investigates whether a hybrid dosimeter, combining an ionisation chamber and two transmission calorimeters, can effectively provide dose-rate independent beam monitoring for both UHDR-RT and conventional radiotherapy (CONV-RT). The goal is to leverage the fast response of ionisation chambers for routine use, while maintaining the dose rate independence of calorimetry for periodic calibrations, to develop a prototype dose rate independent beam monitor. Methods. The hybrid dosimeter was designed and evaluated using the finite element modelling software, COMSOL, to assess the interactions between the ionisation and calorimeter components. Unwanted electrical and thermal effects were studied, including their impact on electric field distribution, charge collection efficiency, and self-heating effects on calorimetry. After construction, the device was tested at the FLASH Core Facility, University of Oxford, in a 6 MeV UHDR-RT beam. Experimental investigations were conducted under various beam conditions to evaluate performance. Results. The hybrid dosimeter demonstrated a linear response in both calorimeter cores and the ionisation chamber. Minimal electrical interference was observed in the proximal calorimeter core due to the ionisation process, though this effect was deemed negligible. The ion collection efficiency was measured to be approximately 3% during the highest dose delivery of 6 Gy/pulse (5.4 MGy/s instantaneous dose rate). A Jaffé plot method derived ion recombination factor for a 2 Gy/pulse (1.8 MGy/s instantaneous dose rate) measurement was determined to be 7.84 ± 2.35 ( k = 1), with a calorimeter derived correction determined to be at least 5.22 ± 0.49 ( k = 1). Conclusions. This study successfully demonstrates the feasibility of combining ionisation and calorimetry into a single hybrid dosimeter. The device offers the potential for online beam monitoring with dose rate independence, making it a promising candidate for UHDR-RT dosimetry and further development for clinical use.
- Open Access
- 21 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (47) , eadz4334
Stable electron-irradiated [1- 13 C]alanine radicals for metabolic imaging with dynamic nuclear polarization
Dissolution dynamic nuclear polarization (dDNP) increases the sensitivity of magnetic resonance experiments by >10 4 -fold, permitting isotopically labeled molecules to be transiently visible in magnetic resonance imaging scans. dDNP mechanistically takes place at ~1 K and requires unpaired electrons and microwaves. These electrons are usually chemical radicals, requiring removal by filtration prior to injection into humans. Alternative sources, such as ultraviolet irradiation, generate lower polarization and require cryogenic transport. We present ultrahigh–dose rate electron irradiation as an alternative for generating nonpersistent radicals in alanine/glycerol mixtures. These are stable for months at room temperature, quench spontaneously upon dissolution, are present in dose-dependent concentrations, and generate comparable nuclear polarization (17%) to trityl radicals used clinically (19%) through a previously unknown mechanism we believe to involve partial ordering and electron-electron interactions. Owing to the large radiation doses required, this process is sterilizing, permits imaging of alanine metabolism in vivo in the rat kidney, and may aid clinically translating dDNP.
- 21 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (47) , eadz4334
Open AccessStable electron-irradiated [1- 13 C]alanine radicals for metabolic imaging with dynamic nuclear polarization
Dissolution dynamic nuclear polarization (dDNP) increases the sensitivity of magnetic resonance experiments by >10 4 -fold, permitting isotopically labeled molecules to be transiently visible in magnetic resonance imaging scans. dDNP mechanistically takes place at ~1 K and requires unpaired electrons and microwaves. These electrons are usually chemical radicals, requiring removal by filtration prior to injection into humans. Alternative sources, such as ultraviolet irradiation, generate lower polarization and require cryogenic transport. We present ultrahigh–dose rate electron irradiation as an alternative for generating nonpersistent radicals in alanine/glycerol mixtures. These are stable for months at room temperature, quench spontaneously upon dissolution, are present in dose-dependent concentrations, and generate comparable nuclear polarization (17%) to trityl radicals used clinically (19%) through a previously unknown mechanism we believe to involve partial ordering and electron-electron interactions. Owing to the large radiation doses required, this process is sterilizing, permits imaging of alanine metabolism in vivo in the rat kidney, and may aid clinically translating dDNP.
- Open Access
- 24 September 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 56, 101052
Quantifying the flash effect and its dependence on average dose rate in vivo for 6 MeV electron and 6 MV photon beams
- 24 September 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 56, 101052
Open AccessQuantifying the flash effect and its dependence on average dose rate in vivo for 6 MeV electron and 6 MV photon beams
- Open Access
- 10 June 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 51 (10) , 3009-3025
First-in-man study of the PSMA Minibody IR800-IAB2M for molecularly targeted intraoperative fluorescence guidance during radical prostatectomy
Purpose: Prostate-specific membrane antigen (PSMA) is increasingly used to image prostate cancer in clinical practice. We sought to develop and test a humanised PSMA minibody IAB2M conjugated to the fluorophore IRDye 800CW-NHS ester in men undergoing robot-assisted laparoscopic radical prostatectomy (RARP) to image prostate cancer cells during surgery. Methods: The minibody was evaluated pre-clinically using PSMA positive/negative xenograft models, following which 23 men undergoing RARP between 2018 and 2020 received between 2.5 mg and 20 mg of IR800-IAB2M intravenously, at intervals between 24 h and 17 days prior to surgery. At every step of the procedure, the prostate, pelvic lymph node chains and extra-prostatic surrounding tissue were imaged with a dual Near-infrared (NIR) and white light optical platform for fluorescence in vivo and ex vivo. Histopathological evaluation of intraoperative and postoperative microscopic fluorescence imaging was undertaken for verification. Results: Twenty-three patients were evaluated to optimise both the dose of the reagent and the interval between injection and surgery and secure the best possible specificity of fluorescence images. Six cases are presented in detail as exemplars. Overall sensitivity and specificity in detecting non-lymph-node extra-prostatic cancer tissue were 100% and 65%, and 64% and 64% respectively for lymph node positivity. There were no side-effects associated with administration of the reagent. Conclusion: Intraoperative imaging of prostate cancer tissue is feasible and safe using IR800-IAB2M. Further evaluation is underway to assess the benefit of using the technique in improving completion of surgical excision during RARP. Registration: ISCRCTN10046036: https://www.isrctn.com/ISRCTN10046036.
- 10 June 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 51 (10) , 3009-3025
Open AccessFirst-in-man study of the PSMA Minibody IR800-IAB2M for molecularly targeted intraoperative fluorescence guidance during radical prostatectomy
Purpose: Prostate-specific membrane antigen (PSMA) is increasingly used to image prostate cancer in clinical practice. We sought to develop and test a humanised PSMA minibody IAB2M conjugated to the fluorophore IRDye 800CW-NHS ester in men undergoing robot-assisted laparoscopic radical prostatectomy (RARP) to image prostate cancer cells during surgery. Methods: The minibody was evaluated pre-clinically using PSMA positive/negative xenograft models, following which 23 men undergoing RARP between 2018 and 2020 received between 2.5 mg and 20 mg of IR800-IAB2M intravenously, at intervals between 24 h and 17 days prior to surgery. At every step of the procedure, the prostate, pelvic lymph node chains and extra-prostatic surrounding tissue were imaged with a dual Near-infrared (NIR) and white light optical platform for fluorescence in vivo and ex vivo. Histopathological evaluation of intraoperative and postoperative microscopic fluorescence imaging was undertaken for verification. Results: Twenty-three patients were evaluated to optimise both the dose of the reagent and the interval between injection and surgery and secure the best possible specificity of fluorescence images. Six cases are presented in detail as exemplars. Overall sensitivity and specificity in detecting non-lymph-node extra-prostatic cancer tissue were 100% and 65%, and 64% and 64% respectively for lymph node positivity. There were no side-effects associated with administration of the reagent. Conclusion: Intraoperative imaging of prostate cancer tissue is feasible and safe using IR800-IAB2M. Further evaluation is underway to assess the benefit of using the technique in improving completion of surgical excision during RARP. Registration: ISCRCTN10046036: https://www.isrctn.com/ISRCTN10046036.
- Open Access
Intra-prostatic tumour evolution, steps in metastatic spread and histogenomic associations revealed by integration of multi-region whole genome sequencing with histopathological features
Extension of prostate cancer beyond the primary site into the surrounding organs by local invasion or nodal metastasis is associated with poor prognosis. The emergence and evolution of cancer clones at this early stage of expansion and spread has not been studied in detail. We performed whole genome sequencing on 42 prostate cancer samples from the prostate, seminal vesicles and regional lymph nodes of five treatment-naive patients with locally advanced disease who underwent radical prostatectomy. Using cancer cell fractions computed from single nucleotide variants and copy number alterations, we reconstructed the tumour phylogenies, which in turn allowed us to infer key molecular steps in the progression of prostate cancer in these individuals. We mapped the clonal composition of cancer sampled across the prostate in each individual and inferred the routes of spread of cancer cells within the prostate and to seminal vesicles and lymph nodes. Based on these data, we delineated the route of tumour progression and metastasis following the transformation of adenocarcinoma to amphicrine morphology, the molecular events leading to whole genome duplication associated with a single clonal expansion and identified putative driver events associated with local invasion and lymph node metastasis. We also correlated genomic changes associated with differences in morphology and identified putative driver events associated with spread to seminal vesicle invasion and lymph node metastasis. Taken together, these findings have implications for diagnosis and risk stratification, in addition to providing a rationale for further studies to characterise the genetic changes associated with morphological transformation. Our results demonstrate the value of integrating multi-region sequencing with histopathological data to study tumour evolution and identify mechanisms of prostate cancer spread.
Open AccessIntra-prostatic tumour evolution, steps in metastatic spread and histogenomic associations revealed by integration of multi-region whole genome sequencing with histopathological features
Extension of prostate cancer beyond the primary site into the surrounding organs by local invasion or nodal metastasis is associated with poor prognosis. The emergence and evolution of cancer clones at this early stage of expansion and spread has not been studied in detail. We performed whole genome sequencing on 42 prostate cancer samples from the prostate, seminal vesicles and regional lymph nodes of five treatment-naive patients with locally advanced disease who underwent radical prostatectomy. Using cancer cell fractions computed from single nucleotide variants and copy number alterations, we reconstructed the tumour phylogenies, which in turn allowed us to infer key molecular steps in the progression of prostate cancer in these individuals. We mapped the clonal composition of cancer sampled across the prostate in each individual and inferred the routes of spread of cancer cells within the prostate and to seminal vesicles and lymph nodes. Based on these data, we delineated the route of tumour progression and metastasis following the transformation of adenocarcinoma to amphicrine morphology, the molecular events leading to whole genome duplication associated with a single clonal expansion and identified putative driver events associated with local invasion and lymph node metastasis. We also correlated genomic changes associated with differences in morphology and identified putative driver events associated with spread to seminal vesicle invasion and lymph node metastasis. Taken together, these findings have implications for diagnosis and risk stratification, in addition to providing a rationale for further studies to characterise the genetic changes associated with morphological transformation. Our results demonstrate the value of integrating multi-region sequencing with histopathological data to study tumour evolution and identify mechanisms of prostate cancer spread.
- Open Access
- 8 February 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (4) , 045015
Monitoring electron energies during FLASH irradiations
When relativistic electrons are used to irradiate tissues, such as during FLASH pre-clinical irradiations, the electron beam energy is one of the critical parameters that determine the dose distribution. Moreover, during such irradiations, linear accelerators (linacs) usually operate with significant beam loading, where a small change in the accelerator output current can lead to beam energy reduction. Optimisation of the tuning of the accelerator’s radio frequency system is often required. We describe here a robust, easy-to-use device for non-interceptive monitoring of potential variations in the electron beam energy during every linac macro-pulse of an irradiation run. Our approach monitors the accelerated electron fringe beam using two unbiased aluminium annular charge collection plates, positioned in the beam path and with apertures (5 cm in diameter) for the central beam. These plates are complemented by two thin annular screening plates to eliminate crosstalk and equalise the capacitances of the charge collection plates. The ratio of the charge picked up on the downstream collection plate to the sum of charges picked up on the both plates is sensitive to the beam energy and to changes in the energy spectrum shape. The energy sensitivity range is optimised to the investigated beam by the choice of thickness of the first plate. We present simulation and measurement data using electrons generated by a nominal 6 MeV energy linac as well as information on the design, the practical implementation and the use of this monitor.
- 8 February 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (4) , 045015
Open AccessMonitoring electron energies during FLASH irradiations
When relativistic electrons are used to irradiate tissues, such as during FLASH pre-clinical irradiations, the electron beam energy is one of the critical parameters that determine the dose distribution. Moreover, during such irradiations, linear accelerators (linacs) usually operate with significant beam loading, where a small change in the accelerator output current can lead to beam energy reduction. Optimisation of the tuning of the accelerator’s radio frequency system is often required. We describe here a robust, easy-to-use device for non-interceptive monitoring of potential variations in the electron beam energy during every linac macro-pulse of an irradiation run. Our approach monitors the accelerated electron fringe beam using two unbiased aluminium annular charge collection plates, positioned in the beam path and with apertures (5 cm in diameter) for the central beam. These plates are complemented by two thin annular screening plates to eliminate crosstalk and equalise the capacitances of the charge collection plates. The ratio of the charge picked up on the downstream collection plate to the sum of charges picked up on the both plates is sensitive to the beam energy and to changes in the energy spectrum shape. The energy sensitivity range is optimised to the investigated beam by the choice of thickness of the first plate. We present simulation and measurement data using electrons generated by a nominal 6 MeV energy linac as well as information on the design, the practical implementation and the use of this monitor.
- Open Access
- 18 December 2019
- Published by Oxford University Press (OUP) in JNCI: Journal of the National Cancer Institute
- Vol. 112 (9) , 944-954
HER2-HER3 Heterodimer Quantification by FRET-FLIM and Patient Subclass Analysis of the COIN Colorectal Trial
The phase III MRC COIN trial showed no statistically significant benefit from adding the EGFR-target cetuximab to oxaliplatin-based chemotherapy in first-line treatment of advanced colorectal cancer. This study exploits additional information on HER2-HER3 dimerization to achieve patient stratification and reveal previously hidden subgroups of patients who had differing disease progression and treatment response. HER2-HER3 dimerization was quantified by fluorescence lifetime imaging microscopy in primary tumor samples from 550 COIN trial patients receiving oxaliplatin and fluoropyrimidine chemotherapy with or without cetuximab. Bayesian latent class analysis and covariate reduction was performed to analyze the effects of HER2-HER3 dimer, RAS mutation, and cetuximab on progression-free survival and overall survival (OS). All statistical tests were two-sided. Latent class analysis on a cohort of 398 patients revealed two patient subclasses with differing prognoses (median OS = 1624 days [95% confidence interval [CI] = 1466 to 1816 days] vs 461 days [95% CI = 431 to 504 days]): Class 1 (15.6%) showed a benefit from cetuximab in OS (hazard ratio = 0.43, 95% CI = 0.25 to 0.76, P = .004). Class 2 showed an association of increased HER2-HER3 with better OS (hazard ratio = 0.64, 95% CI = 0.44 to 0.94, P = .02). A class prediction signature was formed and tested on an independent validation cohort (n = 152) validating the prognostic utility of the dimer assay. Similar subclasses were also discovered in full trial dataset (n = 1630) based on 10 baseline clinicopathological and genetic covariates. Our work suggests that the combined use of HER dimer imaging and conventional mutation analyses will be able to identify a small subclass of patients (>10%) who will have better prognosis following chemotherapy. A larger prospective cohort will be required to confirm its utility in predicting the outcome of anti-EGFR treatment.
- 18 December 2019
- Published by Oxford University Press (OUP) in JNCI: Journal of the National Cancer Institute
- Vol. 112 (9) , 944-954
Open AccessHER2-HER3 Heterodimer Quantification by FRET-FLIM and Patient Subclass Analysis of the COIN Colorectal Trial
The phase III MRC COIN trial showed no statistically significant benefit from adding the EGFR-target cetuximab to oxaliplatin-based chemotherapy in first-line treatment of advanced colorectal cancer. This study exploits additional information on HER2-HER3 dimerization to achieve patient stratification and reveal previously hidden subgroups of patients who had differing disease progression and treatment response. HER2-HER3 dimerization was quantified by fluorescence lifetime imaging microscopy in primary tumor samples from 550 COIN trial patients receiving oxaliplatin and fluoropyrimidine chemotherapy with or without cetuximab. Bayesian latent class analysis and covariate reduction was performed to analyze the effects of HER2-HER3 dimer, RAS mutation, and cetuximab on progression-free survival and overall survival (OS). All statistical tests were two-sided. Latent class analysis on a cohort of 398 patients revealed two patient subclasses with differing prognoses (median OS = 1624 days [95% confidence interval [CI] = 1466 to 1816 days] vs 461 days [95% CI = 431 to 504 days]): Class 1 (15.6%) showed a benefit from cetuximab in OS (hazard ratio = 0.43, 95% CI = 0.25 to 0.76, P = .004). Class 2 showed an association of increased HER2-HER3 with better OS (hazard ratio = 0.64, 95% CI = 0.44 to 0.94, P = .02). A class prediction signature was formed and tested on an independent validation cohort (n = 152) validating the prognostic utility of the dimer assay. Similar subclasses were also discovered in full trial dataset (n = 1630) based on 10 baseline clinicopathological and genetic covariates. Our work suggests that the combined use of HER dimer imaging and conventional mutation analyses will be able to identify a small subclass of patients (>10%) who will have better prognosis following chemotherapy. A larger prospective cohort will be required to confirm its utility in predicting the outcome of anti-EGFR treatment.
- Open Access
- 17 November 2014
- Published by Portland Press Ltd. in Biochemical Society Transactions
- Vol. 42 (6) , 1498-1505
Imaging tumour heterogeneity of the consequences of a PKCα–substrate interaction in breast cancer patients
Breast cancer heterogeneity demands that prognostic models must be biologically driven and recent clinical evidence indicates that future prognostic signatures need evaluation in the context of early compared with late metastatic risk prediction. In pre-clinical studies, we and others have shown that various protein–protein interactions, pertaining to the actin microfilament-associated proteins, ezrin and cofilin, mediate breast cancer cell migration, a prerequisite for cancer metastasis. Moreover, as a direct substrate for protein kinase Cα, ezrin has been shown to be a determinant of cancer metastasis for a variety of tumour types, besides breast cancer; and has been described as a pivotal regulator of metastasis by linking the plasma membrane to the actin cytoskeleton. In the present article, we demonstrate that our tissue imaging-derived parameters that pertain to or are a consequence of the PKC–ezrin interaction can be used for breast cancer prognostication, with inter-cohort reproducibility. The application of fluorescence lifetime imaging microscopy (FLIM) in formalin-fixed paraffin-embedded patient samples to probe protein proximity within the typically <10 nm range to address the oncological challenge of tumour heterogeneity, is discussed.
- 17 November 2014
- Published by Portland Press Ltd. in Biochemical Society Transactions
- Vol. 42 (6) , 1498-1505
Open AccessImaging tumour heterogeneity of the consequences of a PKCα–substrate interaction in breast cancer patients
Breast cancer heterogeneity demands that prognostic models must be biologically driven and recent clinical evidence indicates that future prognostic signatures need evaluation in the context of early compared with late metastatic risk prediction. In pre-clinical studies, we and others have shown that various protein–protein interactions, pertaining to the actin microfilament-associated proteins, ezrin and cofilin, mediate breast cancer cell migration, a prerequisite for cancer metastasis. Moreover, as a direct substrate for protein kinase Cα, ezrin has been shown to be a determinant of cancer metastasis for a variety of tumour types, besides breast cancer; and has been described as a pivotal regulator of metastasis by linking the plasma membrane to the actin cytoskeleton. In the present article, we demonstrate that our tissue imaging-derived parameters that pertain to or are a consequence of the PKC–ezrin interaction can be used for breast cancer prognostication, with inter-cohort reproducibility. The application of fluorescence lifetime imaging microscopy (FLIM) in formalin-fixed paraffin-embedded patient samples to probe protein proximity within the typically <10 nm range to address the oncological challenge of tumour heterogeneity, is discussed.