Maria Jangsten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria Jangsten has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Torbjörn Lindholm
Division of Building Services Engineering, Department of Architecture and Civil Engineering, Chalmers University of Technology
4 shared publications Jan-Olof Dalenbäck
2 shared publications- Jan-Olof Dalenbäck
Division of Building Services Engineering, Department of Architecture and Civil Engineering, Chalmers University of Technology, 412 96 Gothenburg, Sweden
2 shared publications - Jan-Olof Dalenbäck1 shared publication
Mette Lager
1 shared publication- Peter Filipsson
Division of Building Services Engineering, Department of Architecture and Civil Engineering, Chalmers University of Technology
1 shared publication
Latest Publications
- Open Access
- 2 September 2026
- Published by European Council for an Energy Efficient Economy (ECEEE) in eceee Summer Study proceedings
- Vol. 1 (1) , 54
Power signature method for energy performance certification of single-family houses
Peer-reviewed paper 7-212-26 Only about 20% of Sweden’s single-family houses have a valid energy certificate. In the case of energy renovation under the Taxonomy Regulation (down to the top 15% or 30% reduction), banks require verification via independent metering, which means two certificates – before and after measures – and high costs that hinder energy efficiency. At the same time, today’s billing meters provide hourly energy data. The study examines whether energy certificates can be simplified by using hourly data from the energy companies and the power signature method. The goal is an automatic calculation model that calculates heating energy without the need of a site inspection. The study includes simulations and analysis of electricity and district heating data from eleven single-family houses. The results show that power signature, together with balance outdoor temperature and degree days, can distinguish heating from other energy. The method was compared with energy certification according to current method. Since the slope of the power signature is used in the new method, there is no need for guessing standard values for hot water and domestic electricity, which improve quality by providing a more transparent and systematic calculation. The method has the potential to be automated and reduce costs, although an initial site inspection still is required. In the case of a repeated certification, the process could in principle take place electronically in a few minutes, regardless of which independent expert is carrying out the certification.
- 2 September 2026
- Published by European Council for an Energy Efficient Economy (ECEEE) in eceee Summer Study proceedings
- Vol. 1 (1) , 54
Open AccessPower signature method for energy performance certification of single-family houses
Peer-reviewed paper 7-212-26 Only about 20% of Sweden’s single-family houses have a valid energy certificate. In the case of energy renovation under the Taxonomy Regulation (down to the top 15% or 30% reduction), banks require verification via independent metering, which means two certificates – before and after measures – and high costs that hinder energy efficiency. At the same time, today’s billing meters provide hourly energy data. The study examines whether energy certificates can be simplified by using hourly data from the energy companies and the power signature method. The goal is an automatic calculation model that calculates heating energy without the need of a site inspection. The study includes simulations and analysis of electricity and district heating data from eleven single-family houses. The results show that power signature, together with balance outdoor temperature and degree days, can distinguish heating from other energy. The method was compared with energy certification according to current method. Since the slope of the power signature is used in the new method, there is no need for guessing standard values for hot water and domestic electricity, which improve quality by providing a more transparent and systematic calculation. The method has the potential to be automated and reduce costs, although an initial site inspection still is required. In the case of a repeated certification, the process could in principle take place electronically in a few minutes, regardless of which independent expert is carrying out the certification.
- Open Access
- 18 April 2023
- Published by Evolving Cities Publications in Proceedings of the International Conference on Evolving Cities
- p. 17-24
District Cooling – assessment of price models supporting the efficiency
The global cooling demand in buildings is expected to threefold by the year 2050. Compared to individual building cooling equipment, district cooling is a more energy efficient technology to supply this increased cooling demand. However, many district cooling systems suffer from low return temperatures, which usually originate from the buildings’ systems and substations and cause increased operating costs for the district cooling company. Previous studies have identified the need to provide economic incentives to district cooling customers for them to improve the return temperatures from their substations and buildings. The aim of this study is therefore to assess district cooling price models which reward customers who achieve high return temperatures. The study is based on operational data from an actual district cooling system located in Gothenburg, Sweden and 26 of its connected buildings. The current price model of the district cooling system, comprising the three price components energy, power, and flow, was evaluated for the 26 buildings for the years 2018-2020. The results showed the shares of the current price model’s components ranged from 19-63% energy, 28-78% power and 3-21% flow for the different buildings, based on average values for the three analyzed years. This demonstrates the individual variations for the shares of each price component are very large, primarily dependent on the total energy use of the building. It was also seen buildings with a low cost share of the flow component not necessarily had high return temperatures. Based on the current price model assessment, some incentives to maintain well-functioning substations achieving high return temperatures are provided, although the incentives are rather low. Altered price models, for example adjusting the relative cost of the flow component or changing to a return temperature component, are compared with the current price model to find which one is more favorable for customers with high return temperatures. The outcome of this assessment provides district cooling companies with guidance on how to design their price models.
- 18 April 2023
- Published by Evolving Cities Publications in Proceedings of the International Conference on Evolving Cities
- p. 17-24
Open AccessDistrict Cooling – assessment of price models supporting the efficiency
The global cooling demand in buildings is expected to threefold by the year 2050. Compared to individual building cooling equipment, district cooling is a more energy efficient technology to supply this increased cooling demand. However, many district cooling systems suffer from low return temperatures, which usually originate from the buildings’ systems and substations and cause increased operating costs for the district cooling company. Previous studies have identified the need to provide economic incentives to district cooling customers for them to improve the return temperatures from their substations and buildings. The aim of this study is therefore to assess district cooling price models which reward customers who achieve high return temperatures. The study is based on operational data from an actual district cooling system located in Gothenburg, Sweden and 26 of its connected buildings. The current price model of the district cooling system, comprising the three price components energy, power, and flow, was evaluated for the 26 buildings for the years 2018-2020. The results showed the shares of the current price model’s components ranged from 19-63% energy, 28-78% power and 3-21% flow for the different buildings, based on average values for the three analyzed years. This demonstrates the individual variations for the shares of each price component are very large, primarily dependent on the total energy use of the building. It was also seen buildings with a low cost share of the flow component not necessarily had high return temperatures. Based on the current price model assessment, some incentives to maintain well-functioning substations achieving high return temperatures are provided, although the incentives are rather low. Altered price models, for example adjusting the relative cost of the flow component or changing to a return temperature component, are compared with the current price model to find which one is more favorable for customers with high return temperatures. The outcome of this assessment provides district cooling companies with guidance on how to design their price models.
- Open Access
- 6 October 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (10) , 1472-1488
A performance assessment method for district cooling substations based on operational data
Many district cooling systems suffer from low delta-Ts due to faults in the substations and buildings. This causes increased pumping costs, congested distribution networks and operation of more chillers. To enable fault detection and further diagnosis of district cooling substations, knowledge about the actual performance is needed. In this paper, a method using performance indicators to assess the performance of individual district cooling substations was developed along with a ranking system for substation comparison purposes. The performance assessment method was tested on 26 substations in a district cooling system by developing an algorithm. The input to the method was historical operational data collected from the substations’ primary and secondary sides from four years. The output summarized the performance of the substation in a few seconds and the ranking indicated which substation is in most need of improvement. The performance assessment can be conducted with only primary data as input but including secondary data from the building system provides additional information about the substation efficiency along with potential improvement measures. The method can be implemented by a utility company to serve as decision support and facilitate continuous follow-up of the substations to subsequently enable fault detection of district cooling substations.
- 6 October 2022
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 28 (10) , 1472-1488
Open AccessA performance assessment method for district cooling substations based on operational data
Many district cooling systems suffer from low delta-Ts due to faults in the substations and buildings. This causes increased pumping costs, congested distribution networks and operation of more chillers. To enable fault detection and further diagnosis of district cooling substations, knowledge about the actual performance is needed. In this paper, a method using performance indicators to assess the performance of individual district cooling substations was developed along with a ranking system for substation comparison purposes. The performance assessment method was tested on 26 substations in a district cooling system by developing an algorithm. The input to the method was historical operational data collected from the substations’ primary and secondary sides from four years. The output summarized the performance of the substation in a few seconds and the ranking indicated which substation is in most need of improvement. The performance assessment can be conducted with only primary data as input but including secondary data from the building system provides additional information about the substation efficiency along with potential improvement measures. The method can be implemented by a utility company to serve as decision support and facilitate continuous follow-up of the substations to subsequently enable fault detection of district cooling substations.
- Open Access
- 29 March 2021
- Published by EDP Sciences
- Vol. 246, 11004
Field test of active night cooling supplied by district cooling in three commercial buildings
Several previous studies have investigated active night cooling strategies to reduce the peak cooling load in buildings, primarily by precooling the building by the ventilation air during the night. In this study, active night cooling is supplied by the use of district cooling, mainly for cooling buildings by hydronic cooling systems, such as chilled beam or fan coil systems, but potentially also to cool the ventilation air if the outdoor air temperature is above the supply air temperature setpoint. A field test with active night cooling by district cooling was conducted during the summer of 2020 in three commercial buildings located in Gothenburg, Sweden. The active night cooling strategy was implemented by changing the time schedule operation of the buildings’ chilled beam systems to twenty-four hours per day for the first half of the summer and changing back to regular time schedules for the second half. The results showed that active night cooling failed to reduce the hourly maximum cooling power. However, the peak cooling load, corresponding to the 100 hours with the highest cooling power, was reduced with 6.5% for one of the buildings. Active night cooling also reduced the daytime energy usage between 0.7 and 4.6%. The field test demonstrated that some buildings and associated cooling systems are more compatible for active night cooling than others. The test also showed it was possible to achieve some cooling power and energy reductions with simple measures. However, providing active night cooling supplied by district cooling will cause additional costs for the building owners unless it is incentivized by the district cooling provider.
- 29 March 2021
- Published by EDP Sciences
- Vol. 246, 11004
Open AccessField test of active night cooling supplied by district cooling in three commercial buildings
Several previous studies have investigated active night cooling strategies to reduce the peak cooling load in buildings, primarily by precooling the building by the ventilation air during the night. In this study, active night cooling is supplied by the use of district cooling, mainly for cooling buildings by hydronic cooling systems, such as chilled beam or fan coil systems, but potentially also to cool the ventilation air if the outdoor air temperature is above the supply air temperature setpoint. A field test with active night cooling by district cooling was conducted during the summer of 2020 in three commercial buildings located in Gothenburg, Sweden. The active night cooling strategy was implemented by changing the time schedule operation of the buildings’ chilled beam systems to twenty-four hours per day for the first half of the summer and changing back to regular time schedules for the second half. The results showed that active night cooling failed to reduce the hourly maximum cooling power. However, the peak cooling load, corresponding to the 100 hours with the highest cooling power, was reduced with 6.5% for one of the buildings. Active night cooling also reduced the daytime energy usage between 0.7 and 4.6%. The field test demonstrated that some buildings and associated cooling systems are more compatible for active night cooling than others. The test also showed it was possible to achieve some cooling power and energy reductions with simple measures. However, providing active night cooling supplied by district cooling will cause additional costs for the building owners unless it is incentivized by the district cooling provider.