Badrinarayan Rath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Badrinarayan Rath has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Shiferaw Garoma
Department of Civil Engineering, Wollega University, Nekemte, Ethiopia
6 shared publicationsBewiket Dereje
Department of Civil Engineering, Wollega University, Nekemte, Ethiopia
5 shared publicationsKassahun Kebede
Department of Civil Engineering, Wollega University, Nekemte, Ethiopia
5 shared publicationsDabala Misgana
Department of Civil Engineering, Wollega University, Nekemte, Ethiopia
4 shared publications- Praveenkumar Thaloor Ramesh
Department of Civil Engineering, Graphic Era Deemed to be University, Dehradun, India
4 shared publications T. R. Praveenkumar
Centre for Excellence in Research, Rajalakshmi Engineering College, Chennai, India
4 shared publications
Latest Publications
- 4 November 2026
- Published by Springer Nature in Silicon
- p. 1-20
A Double-Phase Packing Density Model for Performance-Based Concrete Mix Design Incorporating Pond Ash and Fly Ash
- 4 November 2026
- Published by Springer Nature in Silicon
- p. 1-20
A Double-Phase Packing Density Model for Performance-Based Concrete Mix Design Incorporating Pond Ash and Fly Ash
- 16 September 2026
- Published by Springer Nature in Architecture, Structures and Construction
- Vol. 6 (2) , 36
A review of rubber latex based concrete from the perspective a circular economy
- 16 September 2026
- Published by Springer Nature in Architecture, Structures and Construction
- Vol. 6 (2) , 36
A review of rubber latex based concrete from the perspective a circular economy
- 10 June 2026
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- p. 1-24
Thermo-mechanical behavior and reliability of glass fiber–reinforced concrete beams at elevated temperatures
Purpose: Concrete structural members in high-temperature industrial environments are susceptible to thermal cracking and performance degradation. This study aims to evaluate the thermo-mechanical behavior and reliability of glass fiber–reinforced concrete (GFRC) beams exposed to elevated temperatures using finite element-based probabilistic assessment. Design/methodology/approach: RC beams incorporating glass fibers at volume fractions of 0.5%, 1.0%, 1.5% and 2.0% were numerically investigated under thermal exposure levels ranging from 25°C to 600°C. A total of 20 beam models were developed in ABAQUS using cohesive zone modeling (CZM) to simulate crack initiation and propagation. Several structural responses were evaluated and probabilistic analysis was conducted to estimate failure probability under thermal loading conditions. Findings: Results indicate that incorporation of 1.5% glass fiber provides the optimum structural response. Compared with conventional RC beams, GFRC beams exhibited an increase of approximately 30–35% in load capacity at crack initiation and a 20–28% increase in mid-span deflection capacity at ambient temperature. Fracture energy increased from 0.10 N/mm in control beams to approximately 0.22 N/mm in fiber-reinforced beams, resulting in a reduction in crack width from 0.102 mm to 0.051 mm. The reliability index increased from β = 1.9 for control beams to β = 2.6 for beams containing 1.5% fibers, while the probability of failure decreased from 18% to 6% after thermal exposure. Originality/value: This study provides a comprehensive numerical framework integrating CZM and reliability-based analysis to assess the high-temperature performance of GFRC beams, offering valuable insights for fire-resistant structural design in industrial applications.
- 10 June 2026
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- p. 1-24
Thermo-mechanical behavior and reliability of glass fiber–reinforced concrete beams at elevated temperatures
Purpose: Concrete structural members in high-temperature industrial environments are susceptible to thermal cracking and performance degradation. This study aims to evaluate the thermo-mechanical behavior and reliability of glass fiber–reinforced concrete (GFRC) beams exposed to elevated temperatures using finite element-based probabilistic assessment. Design/methodology/approach: RC beams incorporating glass fibers at volume fractions of 0.5%, 1.0%, 1.5% and 2.0% were numerically investigated under thermal exposure levels ranging from 25°C to 600°C. A total of 20 beam models were developed in ABAQUS using cohesive zone modeling (CZM) to simulate crack initiation and propagation. Several structural responses were evaluated and probabilistic analysis was conducted to estimate failure probability under thermal loading conditions. Findings: Results indicate that incorporation of 1.5% glass fiber provides the optimum structural response. Compared with conventional RC beams, GFRC beams exhibited an increase of approximately 30–35% in load capacity at crack initiation and a 20–28% increase in mid-span deflection capacity at ambient temperature. Fracture energy increased from 0.10 N/mm in control beams to approximately 0.22 N/mm in fiber-reinforced beams, resulting in a reduction in crack width from 0.102 mm to 0.051 mm. The reliability index increased from β = 1.9 for control beams to β = 2.6 for beams containing 1.5% fibers, while the probability of failure decreased from 18% to 6% after thermal exposure. Originality/value: This study provides a comprehensive numerical framework integrating CZM and reliability-based analysis to assess the high-temperature performance of GFRC beams, offering valuable insights for fire-resistant structural design in industrial applications.
- 22 January 2026
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 17 (3) , 1-29
Thermo-mechanical response of encased steel-tube prestressed concrete beams: influence of load ratio, cover thickness and partial prestressing ratio under fire
Purpose: This study investigates the fire resistance of encased steel tube prestressed concrete (ESPC) beams, addressing the critical challenge of prestressed systems losing strength under elevated temperatures. Conventional prestressed beams are vulnerable to fire due to prestress loss, rapid thermal penetration and spalling. Limited research has explored how load ratio, tendon cover thickness and partial prestressing ratio (PPR) collectively influence thermo-mechanical performance. Design/methodology/approach: A combined experimental and analytical program was conducted, including full-scale fire exposure tests and validated finite element simulations. The study systematically varied load ratios (η = 0.25–0.5), tendon cover thicknesses (45 mm and 70 mm) and PPR values (0.5–0.75). Key response parameters such as deflection, stiffness degradation, cracking patterns, torsional behavior and ultimate failure modes were examined up to 600°C. Findings: Results revealed that a higher load ratio (η = 0.5) significantly enhanced fire resistance by sustaining internal force equilibrium and delaying failure. Thinner covers (45 mm) accelerated thermal ingress but mitigated explosive spalling, whereas thicker covers (70 mm) effectively protected tendons, extending beam stability. PPR exerted a strong influence, with higher ratios (0.75) accelerating cracking and reducing ductility, while optimized combinations of η, tendon cover and PPR improved residual strength and energy absorption. Balanced prestressing and confinement were shown to enhance torsional stiffness and ductility, yielding superior fire resilience. Originality/value: This work provides the first integrated evaluation of ESPC beams under fire, establishing clear correlations between thermal degradation and mechanical response. By offering design-oriented recommendations on prestressing configuration, tendon cover and PPR optimization, the study advances structural fire engineering and guides the development of fire-safe prestressed systems.
- 22 January 2026
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 17 (3) , 1-29
Thermo-mechanical response of encased steel-tube prestressed concrete beams: influence of load ratio, cover thickness and partial prestressing ratio under fire
Purpose: This study investigates the fire resistance of encased steel tube prestressed concrete (ESPC) beams, addressing the critical challenge of prestressed systems losing strength under elevated temperatures. Conventional prestressed beams are vulnerable to fire due to prestress loss, rapid thermal penetration and spalling. Limited research has explored how load ratio, tendon cover thickness and partial prestressing ratio (PPR) collectively influence thermo-mechanical performance. Design/methodology/approach: A combined experimental and analytical program was conducted, including full-scale fire exposure tests and validated finite element simulations. The study systematically varied load ratios (η = 0.25–0.5), tendon cover thicknesses (45 mm and 70 mm) and PPR values (0.5–0.75). Key response parameters such as deflection, stiffness degradation, cracking patterns, torsional behavior and ultimate failure modes were examined up to 600°C. Findings: Results revealed that a higher load ratio (η = 0.5) significantly enhanced fire resistance by sustaining internal force equilibrium and delaying failure. Thinner covers (45 mm) accelerated thermal ingress but mitigated explosive spalling, whereas thicker covers (70 mm) effectively protected tendons, extending beam stability. PPR exerted a strong influence, with higher ratios (0.75) accelerating cracking and reducing ductility, while optimized combinations of η, tendon cover and PPR improved residual strength and energy absorption. Balanced prestressing and confinement were shown to enhance torsional stiffness and ductility, yielding superior fire resilience. Originality/value: This work provides the first integrated evaluation of ESPC beams under fire, establishing clear correlations between thermal degradation and mechanical response. By offering design-oriented recommendations on prestressing configuration, tendon cover and PPR optimization, the study advances structural fire engineering and guides the development of fire-safe prestressed systems.
- 26 May 2025
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 26 (8) , 3317-3340
Numerical analysis on shear behaviour of cold formed steel concrete composite beam with inverted U-shaped internal shear connector
- 26 May 2025
- Published by Springer Nature in Asian Journal of Civil Engineering
- Vol. 26 (8) , 3317-3340
Numerical analysis on shear behaviour of cold formed steel concrete composite beam with inverted U-shaped internal shear connector
- Open Access
- 1 January 2025
- Published by Wiley in Advances in Civil Engineering
- Vol. 2025 (1)
Effectiveness of Straight‐Wall and Sloped‐Wall House Hold Water Tank Acting as a Tuned Liquid Damper in Mitigating Structural Vibrations: A Dynamic Assessment
This research distinguishes the performance of three types of water tanks, which are acting as tuned liquid dampers (TLDs; i.e., rectangular shape flat‐bottom with straight wall, square shape flat‐bottom with straight‐wall, and square shape flat‐bottom with sloped‐wall tanks) in the same plan area firmly fixed to the upper most part of the G+7 framed structure. High‐rise and flexible structures are increasingly vulnerable to dynamic excitations such as earthquakes and wind, making vibration control a critical design challenge. TLDs offer a cost‐effective passive control solution by utilizing liquid sloshing to dissipate seismic energy. This study investigates the effectiveness of different TLD configurations to enhance structural safety and resilience. The finite element analysis for the computation of the structural assessment of the building frame by rigidly attached water tanks has been carried out using commercial software ABAQUS. The structural displacement due to the introduction of three types of water tanks under several water depth ratios, excitation frequency ratios, and tuning frequency ratios have been studied under three different viscosities of liquid, and the effectiveness of the three water tanks has been determined. Among the three types of TLDs (water tanks), the sloped‐wall TLD operates effectively and greatly reduces the undesired motion of the structure during earthquakes. Among straight wall flat‐bottom TLDs, the rectangular shape performs better in partially filled liquids with different viscosities. This happened due to the long traveling of the sloshing wave in the rectangular flat‐bottom water tank as compared to the squared flat‐bottom under an equal plan area. Sloshing frequency and wave numbers are compared between straight‐wall and sloped‐wall TLDs. A mathematical expression of base shear force for both straight‐wall TLD and sloped‐wall TLD has been derived. A correlation between water depth ratio, tuning frequency ratio, viscosity of liquid, and structural displacement has been established by using regression analysis.
- 1 January 2025
- Published by Wiley in Advances in Civil Engineering
- Vol. 2025 (1)
Open AccessEffectiveness of Straight‐Wall and Sloped‐Wall House Hold Water Tank Acting as a Tuned Liquid Damper in Mitigating Structural Vibrations: A Dynamic Assessment
This research distinguishes the performance of three types of water tanks, which are acting as tuned liquid dampers (TLDs; i.e., rectangular shape flat‐bottom with straight wall, square shape flat‐bottom with straight‐wall, and square shape flat‐bottom with sloped‐wall tanks) in the same plan area firmly fixed to the upper most part of the G+7 framed structure. High‐rise and flexible structures are increasingly vulnerable to dynamic excitations such as earthquakes and wind, making vibration control a critical design challenge. TLDs offer a cost‐effective passive control solution by utilizing liquid sloshing to dissipate seismic energy. This study investigates the effectiveness of different TLD configurations to enhance structural safety and resilience. The finite element analysis for the computation of the structural assessment of the building frame by rigidly attached water tanks has been carried out using commercial software ABAQUS. The structural displacement due to the introduction of three types of water tanks under several water depth ratios, excitation frequency ratios, and tuning frequency ratios have been studied under three different viscosities of liquid, and the effectiveness of the three water tanks has been determined. Among the three types of TLDs (water tanks), the sloped‐wall TLD operates effectively and greatly reduces the undesired motion of the structure during earthquakes. Among straight wall flat‐bottom TLDs, the rectangular shape performs better in partially filled liquids with different viscosities. This happened due to the long traveling of the sloshing wave in the rectangular flat‐bottom water tank as compared to the squared flat‐bottom under an equal plan area. Sloshing frequency and wave numbers are compared between straight‐wall and sloped‐wall TLDs. A mathematical expression of base shear force for both straight‐wall TLD and sloped‐wall TLD has been derived. A correlation between water depth ratio, tuning frequency ratio, viscosity of liquid, and structural displacement has been established by using regression analysis.
- 26 August 2023
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 8 (9) , 1-23
Thermal stress–strain analysis of CFRP-laminated concrete beam with partial replacement of fine aggregate by PET granules
- 26 August 2023
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 8 (9) , 1-23
Thermal stress–strain analysis of CFRP-laminated concrete beam with partial replacement of fine aggregate by PET granules
- 22 August 2023
- Published by Springer Nature in Multiscale and Multidisciplinary Modeling, Experiments and Design
- Vol. 7 (1) , 425-441
Shear resistance analysis of intermediate short columns subjected to lateral loading using numerical method
- 22 August 2023
- Published by Springer Nature in Multiscale and Multidisciplinary Modeling, Experiments and Design
- Vol. 7 (1) , 425-441
Shear resistance analysis of intermediate short columns subjected to lateral loading using numerical method
- 7 June 2023
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 145 (11) , 1-18
Performance and Emission Characteristics for Karanja Biodiesel Blends Assisted With Green Hydrogen Fuel and Nanoparticles
Extensive efforts are being made to produce and use a variety of alternative energies in order to meet the rising global energy demand. The main purpose of this research was to evaluate the mass fuel burnt, emissions, and performance properties of biodiesel made from non-edible karanja oil along with hydrogen and nanoparticles in a standard diesel engine. Upon experimental evaluation, it was determined that the transesterified karanja oil retained all of its vital physicochemical properties within the specified tolerances. The emission and performance characteristics of karanja biodiesel blended with nanoparticles and hydrogen fuel were assessed at different engine loads ranging from 0% to 100%. The uniform amount of nanoparticles and hydrogen was incorporated into test fuels. Al2O3 nanoparticles of 50 ppm were used in this study and hydrogen of 5 L/min was supplied to the engine. K20NH test fuel had the maximum brake thermal efficiency and less brake-specific fuel consumption compared to the other fuel blend. The emissions were considerably reduced on karanja oil, nanoparticles, and hydrogen-blended biodiesel except for nitrogen emission compared with conventional diesel fuel. In this study, the utilization of karanja, nanoparticles, and hydrogen-blended biodiesel showed a promising alternative to fossil fuels due to reduced emission and enhanced performance characteristics.
- 7 June 2023
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 145 (11) , 1-18
Performance and Emission Characteristics for Karanja Biodiesel Blends Assisted With Green Hydrogen Fuel and Nanoparticles
Extensive efforts are being made to produce and use a variety of alternative energies in order to meet the rising global energy demand. The main purpose of this research was to evaluate the mass fuel burnt, emissions, and performance properties of biodiesel made from non-edible karanja oil along with hydrogen and nanoparticles in a standard diesel engine. Upon experimental evaluation, it was determined that the transesterified karanja oil retained all of its vital physicochemical properties within the specified tolerances. The emission and performance characteristics of karanja biodiesel blended with nanoparticles and hydrogen fuel were assessed at different engine loads ranging from 0% to 100%. The uniform amount of nanoparticles and hydrogen was incorporated into test fuels. Al2O3 nanoparticles of 50 ppm were used in this study and hydrogen of 5 L/min was supplied to the engine. K20NH test fuel had the maximum brake thermal efficiency and less brake-specific fuel consumption compared to the other fuel blend. The emissions were considerably reduced on karanja oil, nanoparticles, and hydrogen-blended biodiesel except for nitrogen emission compared with conventional diesel fuel. In this study, the utilization of karanja, nanoparticles, and hydrogen-blended biodiesel showed a promising alternative to fossil fuels due to reduced emission and enhanced performance characteristics.