Makoto Orii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Makoto Orii has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Kunihiro Yoshioka
Department of Radiology, Iwate Medical University, Yahaba, Japan
12 shared publicationsJumpei Fujiwara
Department of Radiology, Iwate Medical University, Yahaba, Japan
5 shared publicationsMisato Sone
Department of Radiology, Iwate Medical University, Yahaba, Japan
5 shared publicationsTakuya Chiba
Center for Radiological Science, Iwate Medical University, Yahaba, Japan
5 shared publicationsTsuyoshi Sugawara
Department of Radiology Service, Iwate Medical University, Yahaba, Japan
5 shared publicationsTakeshi Osaki
Department of Radiology, Iwate Medical University, Yahaba, Japan
4 shared publications
Latest Publications
- 27 January 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (5) , 845-854
Automatic detection and measurement system for aortic aneurysms using deep learning-based artificial intelligence
This study evaluated the performance of a deep learning-based artificial intelligence (DLAI) system for detecting fusiform aortic aneurysms and measuring the diameters of the entire aorta on non-contrast CT images.We retrospectively collected 160 non-contrast CT images (130 males, 71.8 ± 9.2 years) to evaluate aortic aneurysms and used them as training data. To evaluate the accuracy of the DLAI system for the automatic detection and measurement of aortic aneurysms, another 190 non-contrast CT images (153 males, 70.7 ± 10.3 years) were collected and used as validation data. First, the accuracy of DLAI results was calculated by referring to the radiology reports. An expert radiologist read the test data again and calculated the final accuracy by referring to the DLAI predictions.Dice scores for aortic segmentation were 0.90, 0.94, 0.93, and 0.84 for the entire aorta, thoracic aorta, abdominal aorta, and iliac artery, respectively. The sensitivity, positive predictive value, and F-measure of the DLAI system for detecting aortic aneurysms were 0.81, 0.83, and 0.82, respectively. Eleven (4.4%) aneurysms were newly identified after the radiologist’s second reading based on DLAI predictions. The final accuracy of the DLAI detection increased to 0.83, 0.87, and 0.85 for sensitivity, positive predictive value, and F-measure, respectively. The size error in the measurement of aortic aneurysms between the DLAI system and radiology reports was 0.86 ± 2.72 mm, with a strong correlation (ICCs = 0.97).Our DLAI system was highly accurate in detecting aneurysms and measuring the diameters of the entire aorta on non-contrast CT images. Graphical Abstract
- 27 January 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (5) , 845-854
Automatic detection and measurement system for aortic aneurysms using deep learning-based artificial intelligence
This study evaluated the performance of a deep learning-based artificial intelligence (DLAI) system for detecting fusiform aortic aneurysms and measuring the diameters of the entire aorta on non-contrast CT images.We retrospectively collected 160 non-contrast CT images (130 males, 71.8 ± 9.2 years) to evaluate aortic aneurysms and used them as training data. To evaluate the accuracy of the DLAI system for the automatic detection and measurement of aortic aneurysms, another 190 non-contrast CT images (153 males, 70.7 ± 10.3 years) were collected and used as validation data. First, the accuracy of DLAI results was calculated by referring to the radiology reports. An expert radiologist read the test data again and calculated the final accuracy by referring to the DLAI predictions.Dice scores for aortic segmentation were 0.90, 0.94, 0.93, and 0.84 for the entire aorta, thoracic aorta, abdominal aorta, and iliac artery, respectively. The sensitivity, positive predictive value, and F-measure of the DLAI system for detecting aortic aneurysms were 0.81, 0.83, and 0.82, respectively. Eleven (4.4%) aneurysms were newly identified after the radiologist’s second reading based on DLAI predictions. The final accuracy of the DLAI detection increased to 0.83, 0.87, and 0.85 for sensitivity, positive predictive value, and F-measure, respectively. The size error in the measurement of aortic aneurysms between the DLAI system and radiology reports was 0.86 ± 2.72 mm, with a strong correlation (ICCs = 0.97).Our DLAI system was highly accurate in detecting aneurysms and measuring the diameters of the entire aorta on non-contrast CT images. Graphical Abstract
- 19 December 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 117, 110313
Reliability of post-contrast deep learning-based highly accelerated cardiac cine MRI for the assessment of ventricular function
- 19 December 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 117, 110313
Reliability of post-contrast deep learning-based highly accelerated cardiac cine MRI for the assessment of ventricular function
- 19 November 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (5) , 2321-2332
Evaluation of SR-DLR in low-dose abdominal CT: superior image quality and noise reduction
Objectives To evaluate the effectiveness of super-resolution deep learning reconstruction (SR-DLR) in low-dose abdominal computed tomography (CT) imaging compared with hybrid iterative reconstruction (HIR) and conventional deep learning reconstruction (cDLR) algorithms. Methods We retrospectively analyzed abdominal CT scans performed using a low-dose protocol. Three different image reconstruction algorithms—HIR, cDLR, and SR-DLR—were applied to the same raw image data. Objective evaluations included noise magnitude and contrast-to-noise ratio (CNR), as well as noise power spectrum (NPS) and edge rise slope (ERS). Subjective evaluations were performed by radiologists, who assessed image quality in terms of noise, artifacts, sharpness, and overall diagnostic utility. Results Raw CT image data were obtained from 35 patients (mean CTDIvol 11.0 mGy; mean DLP 344.8 mGy/cm). cDLR yielded the lowest noise levels and highest CNR (p < 0.001). However, SR-DLR outperformed cDLR in terms of noise texture and resolution, achieving the lowest NPS peak and highest ERS (p < 0.001 and p = 0.005, respectively). Subjectively, SR-DLR was rated highest across all categories, including noise, artifacts, sharpness, and overall image quality, with statistically significant differences compared to cDLR and HIR (p < 0.001). Conclusion SR-DLR was the most effective reconstruction algorithm for low-dose abdominal CT imaging, offering superior image quality and noise reduction compared to cDLR and HIR. This suggests that SR-DLR can enhance the reliability and diagnostic accuracy of abdominal imaging, particularly in low-dose settings, making it a valuable tool in clinical practice.
- 19 November 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (5) , 2321-2332
Evaluation of SR-DLR in low-dose abdominal CT: superior image quality and noise reduction
Objectives To evaluate the effectiveness of super-resolution deep learning reconstruction (SR-DLR) in low-dose abdominal computed tomography (CT) imaging compared with hybrid iterative reconstruction (HIR) and conventional deep learning reconstruction (cDLR) algorithms. Methods We retrospectively analyzed abdominal CT scans performed using a low-dose protocol. Three different image reconstruction algorithms—HIR, cDLR, and SR-DLR—were applied to the same raw image data. Objective evaluations included noise magnitude and contrast-to-noise ratio (CNR), as well as noise power spectrum (NPS) and edge rise slope (ERS). Subjective evaluations were performed by radiologists, who assessed image quality in terms of noise, artifacts, sharpness, and overall diagnostic utility. Results Raw CT image data were obtained from 35 patients (mean CTDIvol 11.0 mGy; mean DLP 344.8 mGy/cm). cDLR yielded the lowest noise levels and highest CNR (p < 0.001). However, SR-DLR outperformed cDLR in terms of noise texture and resolution, achieving the lowest NPS peak and highest ERS (p < 0.001 and p = 0.005, respectively). Subjectively, SR-DLR was rated highest across all categories, including noise, artifacts, sharpness, and overall image quality, with statistically significant differences compared to cDLR and HIR (p < 0.001). Conclusion SR-DLR was the most effective reconstruction algorithm for low-dose abdominal CT imaging, offering superior image quality and noise reduction compared to cDLR and HIR. This suggests that SR-DLR can enhance the reliability and diagnostic accuracy of abdominal imaging, particularly in low-dose settings, making it a valuable tool in clinical practice.
- 8 October 2024
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 18 (6) , 575-582
Energy-integrating detector based ultra-high-resolution CT with deep learning reconstruction for the assessment of calcified lesions in coronary artery disease
- 8 October 2024
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 18 (6) , 575-582
Energy-integrating detector based ultra-high-resolution CT with deep learning reconstruction for the assessment of calcified lesions in coronary artery disease
- Open Access
- 2 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (10) , 4478-4481
Double-chambered left ventricle as a novel cause of aneurysm formation at the apex of accessory chamber
- 2 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (10) , 4478-4481
Open AccessDouble-chambered left ventricle as a novel cause of aneurysm formation at the apex of accessory chamber
- Open Access
- 30 October 2023
- Published by Springer Nature in BMC Medical Imaging
- Vol. 23 (1) , 1-10
Super-resolution deep learning reconstruction at coronary computed tomography angiography to evaluate the coronary arteries and in-stent lumen: an initial experience
A super-resolution deep learning reconstruction (SR-DLR) algorithm trained using data acquired on the ultrahigh spatial resolution computed tomography (UHRCT) has the potential to provide better image quality of coronary arteries on the whole-heart, single-rotation cardiac coverage on a 320-detector row CT scanner. However, the advantages of SR-DLR at coronary computed tomography angiography (CCTA) have not been fully investigated. The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between SR-DLR and model-based iterative reconstruction (MBIR). We prospectively enrolled 70 patients (median age, 69 years; interquartile range [IQR], 59–75 years; 50 men) who underwent CCTA using a 320-detector row CT scanner between January and August 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the twenty stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.3–24.9 HU vs. 27.4 HU; IQR, 24.2–31.2 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 11.8–21.8 vs. 13.7; IQR, 9.9–18.4, p = 0.01) and CNR (median 24.4; IQR, 15.5–30.2 vs. 19.2; IQR, 14.1–23.2, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.68 mm; IQR, 0.61–0.78 mm vs. 0.81 mm; IQR, 0.72–0.96 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.84 mm; IQR, 1.65–2.26 mm vs. 1.52 mm; IQR, 1.28–2.25 mm, p < 0.01) on SR-DLR than on MBIR. Although further large-scale studies using invasive coronary angiography as the reference standard, comparative studies with UHRCT, and studies in more challenging population for CCTA are needed, this study’s initial experience with SR-DLR would improve the utility of CCTA in daily clinical practice due to the better image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.
- 30 October 2023
- Published by Springer Nature in BMC Medical Imaging
- Vol. 23 (1) , 1-10
Open AccessSuper-resolution deep learning reconstruction at coronary computed tomography angiography to evaluate the coronary arteries and in-stent lumen: an initial experience
A super-resolution deep learning reconstruction (SR-DLR) algorithm trained using data acquired on the ultrahigh spatial resolution computed tomography (UHRCT) has the potential to provide better image quality of coronary arteries on the whole-heart, single-rotation cardiac coverage on a 320-detector row CT scanner. However, the advantages of SR-DLR at coronary computed tomography angiography (CCTA) have not been fully investigated. The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between SR-DLR and model-based iterative reconstruction (MBIR). We prospectively enrolled 70 patients (median age, 69 years; interquartile range [IQR], 59–75 years; 50 men) who underwent CCTA using a 320-detector row CT scanner between January and August 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the twenty stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.3–24.9 HU vs. 27.4 HU; IQR, 24.2–31.2 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 11.8–21.8 vs. 13.7; IQR, 9.9–18.4, p = 0.01) and CNR (median 24.4; IQR, 15.5–30.2 vs. 19.2; IQR, 14.1–23.2, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.68 mm; IQR, 0.61–0.78 mm vs. 0.81 mm; IQR, 0.72–0.96 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.84 mm; IQR, 1.65–2.26 mm vs. 1.52 mm; IQR, 1.28–2.25 mm, p < 0.01) on SR-DLR than on MBIR. Although further large-scale studies using invasive coronary angiography as the reference standard, comparative studies with UHRCT, and studies in more challenging population for CCTA are needed, this study’s initial experience with SR-DLR would improve the utility of CCTA in daily clinical practice due to the better image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.
- Open Access
- 30 September 2023
- Published by International Heart Journal (Japanese Heart Journal) in International Heart Journal
- Vol. 64 (5) , 839-846
A Comparison of Retrospective ECG-Gated CT and Surgical or Angiographical Findings in Acute Aortic Syndrome
The best cardiac phases in retrospective ECG-gated CT for detecting an intimal tear (IT) in aortic dissection (AD) and an ulcer-like projection (ULP) in an intramural hematoma (IMH) have not been established. This study aimed to compare the detection accuracy of diastolic-phase and systolic-phase ECG-gated CT for IT in AD and ULP in IMH, with subsequent surgical or angiographical confirmation as the reference standard.In total, 81 patients (67.6 ± 11.8 years; 41 men) who underwent emergency ECG-gated CT and subsequent open surgery or thoracic endovascular aortic repair for AD (n = 52) or IMH (n = 29) were included. The accuracies of detecting IT and ULP were compared among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of retrospective ECG-gated CT; surgical or angiographical findings were used as the reference standard. The detection accuracy for IT and ULP using only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of ECG-gated CT was 93% [95% CI: 87-97], 94% [95% CI: 88-97], and 95% [95% CI: 90-97], respectively. There were no significant differences in detection accuracy among the 3 acquisition methods (P = 0.55). Similarly, there were no significant differences in the accuracy of detecting IT in AD (P = 0.55) and ULP in IMH (P > 0.99) among only diastolic-phase, only systolic-phase, and both diastolic- and systolic-phase ECG-gated CT.Retrospective ECG-gated CT for detecting IT in AD and ULP in IMH yields highly accurate findings. There were no significant differences seen among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase ECG-gated CT.
- 30 September 2023
- Published by International Heart Journal (Japanese Heart Journal) in International Heart Journal
- Vol. 64 (5) , 839-846
Open AccessA Comparison of Retrospective ECG-Gated CT and Surgical or Angiographical Findings in Acute Aortic Syndrome
The best cardiac phases in retrospective ECG-gated CT for detecting an intimal tear (IT) in aortic dissection (AD) and an ulcer-like projection (ULP) in an intramural hematoma (IMH) have not been established. This study aimed to compare the detection accuracy of diastolic-phase and systolic-phase ECG-gated CT for IT in AD and ULP in IMH, with subsequent surgical or angiographical confirmation as the reference standard.In total, 81 patients (67.6 ± 11.8 years; 41 men) who underwent emergency ECG-gated CT and subsequent open surgery or thoracic endovascular aortic repair for AD (n = 52) or IMH (n = 29) were included. The accuracies of detecting IT and ULP were compared among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of retrospective ECG-gated CT; surgical or angiographical findings were used as the reference standard. The detection accuracy for IT and ULP using only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase methods of ECG-gated CT was 93% [95% CI: 87-97], 94% [95% CI: 88-97], and 95% [95% CI: 90-97], respectively. There were no significant differences in detection accuracy among the 3 acquisition methods (P = 0.55). Similarly, there were no significant differences in the accuracy of detecting IT in AD (P = 0.55) and ULP in IMH (P > 0.99) among only diastolic-phase, only systolic-phase, and both diastolic- and systolic-phase ECG-gated CT.Retrospective ECG-gated CT for detecting IT in AD and ULP in IMH yields highly accurate findings. There were no significant differences seen among only diastolic-phase, only systolic-phase, and both diastolic-phase and systolic-phase ECG-gated CT.
- 17 January 2023
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 39 (5) , 1001-1011
Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population
This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.
- 17 January 2023
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 39 (5) , 1001-1011
Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population
This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.
- Open Access
- 16 November 2022
- Published by Springer Nature in Research Square
Super-resolution deep learning reconstruction at coronary computed tomography angiography to evaluate the coronary arteries and in-stent lumen: An initial experience
The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between super-resolution deep learning reconstruction (SR-DLR) and model-based iterative reconstruction (MBIR). We prospectively enrolled 50 patients (median age, 68 years; interquartile range [IQR], 59–74 years; 34 men) who underwent coronary computed tomography angiography (CCTA) using a 320-detector row CT scanner between January and April 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the ten stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.1–24.5 HU vs. 27.4 HU; IQR, 24.1–31.1 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 12.0–22.0 vs. 13.9; IQR, 9.8–19.2, p = 0.03) and CNR (median 25.2; IQR, 16.9–30.8 vs. 19.5; IQR, 14.5–23.7, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.66 mm; IQR, 0.61–0.72 mm vs. 0.80 mm; IQR, 0.68–0.86 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.82 mm; IQR, 1.57–1.95 mm vs. 1.34 mm; IQR, 1.26–1.60 mm, p < 0.01) on SR-DLR than on MBIR. This study’s initial experience with SR-DLR improves the image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.
- 16 November 2022
- Published by Springer Nature in Research Square
Open AccessSuper-resolution deep learning reconstruction at coronary computed tomography angiography to evaluate the coronary arteries and in-stent lumen: An initial experience
The present study aimed to compare the image quality of the coronary arteries and in-stent lumen between super-resolution deep learning reconstruction (SR-DLR) and model-based iterative reconstruction (MBIR). We prospectively enrolled 50 patients (median age, 68 years; interquartile range [IQR], 59–74 years; 34 men) who underwent coronary computed tomography angiography (CCTA) using a 320-detector row CT scanner between January and April 2022. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal coronary arteries were calculated. Of the ten stents, stent strut thickness and luminal diameter were quantitatively evaluated. The image noise on SR-DLR was significantly lower than that on MBIR (median 22.1 HU; IQR, 19.1–24.5 HU vs. 27.4 HU; IQR, 24.1–31.1 HU, p < 0.01), whereas the SNR (median 16.3; IQR, 12.0–22.0 vs. 13.9; IQR, 9.8–19.2, p = 0.03) and CNR (median 25.2; IQR, 16.9–30.8 vs. 19.5; IQR, 14.5–23.7, p < 0.01) on SR-DLR were significantly higher than that on MBIR. Stent struts were significantly thinner (median, 0.66 mm; IQR, 0.61–0.72 mm vs. 0.80 mm; IQR, 0.68–0.86 mm, p < 0.01) and in-stent lumens were significantly larger (median, 1.82 mm; IQR, 1.57–1.95 mm vs. 1.34 mm; IQR, 1.26–1.60 mm, p < 0.01) on SR-DLR than on MBIR. This study’s initial experience with SR-DLR improves the image quality of the coronary arteries and in-stent lumen at CCTA compared with conventional MBIR.