George Papen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
George Papen has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Alex Forencich
University of California, San Diego, La Jolla, CA, USA
2 shared publications Alex C. Snoeren
Univ Calif San Diego, Dept Comp Sci & Engn, 9500 Gilman Dr, La Jolla, CA 92093 USA
1 shared publication- Alex C. Snoeren
University of California, San Diego, San Diego, CA, USA
1 shared publication Alex Forencich
Univ Calif San Diego, Dept Elect & Comp Engn, 9500 Gilman Dr, La Jolla, CA 92093 USA
1 shared publication- Alex Forencich
Department of Electrical and Computer Engineering, University of California, San Diego, CA, USA
1 shared publication - Amin Vahdat
Google LLC, Mountain View, CA, USA
1 shared publication
Latest Publications
- Open Access
- 4 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 392-414
Realizing RotorNet: Toward Practical Microsecond Scale Optical Networking
We describe our experience building and deploying a demand-oblivious optically-switched network based on the RotorNet and Opera architectures. We detail the design, manufacture, deployment, and end-to-end operation of a 128-port optical rotor switch along with supporting NIC hardware and host software. Using this prototype, we assess yield, synchronization, and interoperability with commodity hardware and software at a scale of practical relevance. We provide the first real-world measurements of Linux TCP throughput and host-to-host latency in an operational RotorNet, achieving 98% of link rate with 99th-percentile ping times faster than commodity packet-switching hardware. In the process, we uncover unexpected challenges with link-level dropouts and devise a novel and flexible way to address them. Our deployment experience demonstrates the feasibility of our implementation approach and identifies opportunities for future exploration.
- 4 August 2024
- Published by Association for Computing Machinery (ACM)
- p. 392-414
Open AccessRealizing RotorNet: Toward Practical Microsecond Scale Optical Networking
We describe our experience building and deploying a demand-oblivious optically-switched network based on the RotorNet and Opera architectures. We detail the design, manufacture, deployment, and end-to-end operation of a 128-port optical rotor switch along with supporting NIC hardware and host software. Using this prototype, we assess yield, synchronization, and interoperability with commodity hardware and software at a scale of practical relevance. We provide the first real-world measurements of Linux TCP throughput and host-to-host latency in an operational RotorNet, achieving 98% of link rate with 99th-percentile ping times faster than commodity packet-switching hardware. In the process, we uncover unexpected challenges with link-level dropouts and devise a novel and flexible way to address them. Our deployment experience demonstrates the feasibility of our implementation approach and identifies opportunities for future exploration.
- Open Access
- 10 September 2023
- Published by Association for Computing Machinery (ACM)
- p. 499-515
Lightwave Fabrics: At-Scale Optical Circuit Switching for Datacenter and Machine Learning Systems
- 10 September 2023
- Published by Association for Computing Machinery (ACM)
- p. 499-515
Open AccessLightwave Fabrics: At-Scale Optical Circuit Switching for Datacenter and Machine Learning Systems
- 4 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (9) , 2823-2829
Characterization of Burst-Mode Links for Optical Circuit Switching
The performance of an optically circuit-switched network depends on the transient locking characteristics of the transceiver as a function of the received power before and after a switching event. These characteristics are not specified in current transceiver standards. Here, we present a novel characterization method to assess the transient locking characteristics of transceivers when used in an optical circuit-switched network. The method uses custom hardware code implemented on a high-performance FPGA. This code samples the bit error rate in a manner similar to a sampling oscilloscope. The output is a time-resolved bit error rate measurement on a microsecond time scale. We then use this technique to quantify the transient locking characteristics of commercial datacom transceivers as a function of the nominal received power, the power offset between the channels being switched, and the transition time of the optical switch. These results enable research into optical circuit-switched networks based on commercial datacom transceivers.
- 4 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (9) , 2823-2829
Characterization of Burst-Mode Links for Optical Circuit Switching
The performance of an optically circuit-switched network depends on the transient locking characteristics of the transceiver as a function of the received power before and after a switching event. These characteristics are not specified in current transceiver standards. Here, we present a novel characterization method to assess the transient locking characteristics of transceivers when used in an optical circuit-switched network. The method uses custom hardware code implemented on a high-performance FPGA. This code samples the bit error rate in a manner similar to a sampling oscilloscope. The output is a time-resolved bit error rate measurement on a microsecond time scale. We then use this technique to quantify the transient locking characteristics of commercial datacom transceivers as a function of the nominal received power, the power offset between the channels being switched, and the transition time of the optical switch. These results enable research into optical circuit-switched networks based on commercial datacom transceivers.
- 8 October 2020
- Published by Optica Publishing Group in Journal of Optical Communications and Networking
- Vol. 12 (12) , 378-389
Optical networking within the Lightwave Energy-Efficient Datacenter project [Invited]
The Lightwave Energy-Efficient Datacenter (LEED) project within the ARPA-e ENLITENED program is developing novel energy-efficient multichannel lightwave networks. These networks are enabled by a new optical “rotor” switch that can reconfigure the network topology in less than 20 µs and a field-programmable-gate-array-based network interface controller called Corundum that can provide precise network-wide synchronization of packets admitted into the lightwave network. Here we review the optical networking research within LEED and discuss future directions.
- 8 October 2020
- Published by Optica Publishing Group in Journal of Optical Communications and Networking
- Vol. 12 (12) , 378-389
Optical networking within the Lightwave Energy-Efficient Datacenter project [Invited]
The Lightwave Energy-Efficient Datacenter (LEED) project within the ARPA-e ENLITENED program is developing novel energy-efficient multichannel lightwave networks. These networks are enabled by a new optical “rotor” switch that can reconfigure the network topology in less than 20 µs and a field-programmable-gate-array-based network interface controller called Corundum that can provide precise network-wide synchronization of packets admitted into the lightwave network. Here we review the optical networking research within LEED and discuss future directions.
- 30 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 38 (6) , 1330-1340
A Dynamically-Reconfigurable Burst-Mode Link Using a Nanosecond Photonic Switch
Fast optical circuit switching has significant potential to solve scaling issues with traditional packet-switch based networks and improve bandwidth and power efficiency in datacenter and high-performance computing applications. One difficultly in utilizing a fast optical switch is that the optical signal must be rapidly reacquired after each switching event so as to not significantly impact the overall throughput of the system. Here we present a system-level integration of a nanosecond-scale $2 \times 2$ silicon photonic switch with a 25-Gbps burst-mode receiver that can lock in 31 ns. A novel FPGA-based control plane was used to generate test data, control the silicon photonic switch and burst-mode receiver, and measure bit errors at 12.5 and 20 Gbps. Error-free links (BER $< 10^{-12}$ ) with system-level reconfiguration times below 60 ns (at 20 Gbps) and 90 ns (at 12.5 Gbps) including bit- and frame-synchronization are demonstrated.- 30 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 38 (6) , 1330-1340
A Dynamically-Reconfigurable Burst-Mode Link Using a Nanosecond Photonic Switch
Fast optical circuit switching has significant potential to solve scaling issues with traditional packet-switch based networks and improve bandwidth and power efficiency in datacenter and high-performance computing applications. One difficultly in utilizing a fast optical switch is that the optical signal must be rapidly reacquired after each switching event so as to not significantly impact the overall throughput of the system. Here we present a system-level integration of a nanosecond-scale $2 \times 2$ silicon photonic switch with a 25-Gbps burst-mode receiver that can lock in 31 ns. A novel FPGA-based control plane was used to generate test data, control the silicon photonic switch and burst-mode receiver, and measure bit errors at 12.5 and 20 Gbps. Error-free links (BER $< 10^{-12}$ ) with system-level reconfiguration times below 60 ns (at 20 Gbps) and 90 ns (at 12.5 Gbps) including bit- and frame-synchronization are demonstrated.- 1 January 2020
- Published by Optica Publishing Group
- p. PsTh2F.1
Optical Switching in Data Centers
The necessary conditions for the widespread deployment of optical circuit switching within data centers are discussed. Matching the speed of the optical switch to the control plane that synchronizes packet transmissions is highlighted.
- 1 January 2020
- Published by Optica Publishing Group
- p. PsTh2F.1
Optical Switching in Data Centers
The necessary conditions for the widespread deployment of optical circuit switching within data centers are discussed. Matching the speed of the optical switch to the control plane that synchronizes packet transmissions is highlighted.
- Open Access
- 15 October 1995
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 22 (20) , 2805-2808
Concurrent observations of auroral activity and a large sporadic sodium layer event during ANLC‐93
Prominent sporadic sodium (Nas) layers, apparently associated with intense auroral activity, were observed during the 1993 Arctic Noctilucent Cloud Campaign (ANLC‐93) with an airborne sodium lidar on the August 6 flight near 51°N latitude. The peak density of the Nas layer reached 74,500 cm−3. The zonal extent of the Nas layers exceeded 1600 km. Strong auroral emissions were recorded with an all‐sky imager on the aircraft. A Michelson Interferometer was used to measure the intensity of OH nightglow between 85–90 km. OH rotational temperature exhibited no obvious correlation with the Nas layer peak density near 94 km. The data suggest a connection between the Nas layers and auroral electron precipitations. The data also support the conjecture that dust and smoke particles may play a crucial role in the Nas layer formation.
- 15 October 1995
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 22 (20) , 2805-2808
Open AccessConcurrent observations of auroral activity and a large sporadic sodium layer event during ANLC‐93
Prominent sporadic sodium (Nas) layers, apparently associated with intense auroral activity, were observed during the 1993 Arctic Noctilucent Cloud Campaign (ANLC‐93) with an airborne sodium lidar on the August 6 flight near 51°N latitude. The peak density of the Nas layer reached 74,500 cm−3. The zonal extent of the Nas layers exceeded 1600 km. Strong auroral emissions were recorded with an all‐sky imager on the aircraft. A Michelson Interferometer was used to measure the intensity of OH nightglow between 85–90 km. OH rotational temperature exhibited no obvious correlation with the Nas layer peak density near 94 km. The data suggest a connection between the Nas layers and auroral electron precipitations. The data also support the conjecture that dust and smoke particles may play a crucial role in the Nas layer formation.