Weiquan Wang
Research Subjects
Weiquan Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Chongyi Lu
Dandong Power Supply Company of State Grid Liaoning Electric Power Co., Ltd, Dandong 118000, China
2 shared publications- Rutian Wang
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin, China
2 shared publications Chaochao Li
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education (Northeast Electric Power University), Jilin 132012, China
1 shared publication- Chuang Liu
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology, Northeast Electric Power University, Jilin 132012, China
1 shared publication - Hao Wang
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin, China
1 shared publication - Shiyu Zhang
Key Laboratory of Modern Power System Simulation and Control and Renewable Energy Technology, Ministry of Education, Northeast Electric Power University, Jilin, China
1 shared publication
Latest Publications
- Open Access
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 165678-165691
Wide-Voltage Input Photovoltaic Microgrid System Based on Multi-Port Three-Level Converter
This article presents a photovoltaic micro-grid system structure with multiport three-level converter(MP-TLC). In this structure, two AC power supplies/loads with different operating amplitudes and frequencies can be directly connected through MP-TLC without multiple power conversion units. Compared with the traditional configuration, the structure of the multi-port converter photovoltaic microgrid system operates under a multi-level voltage, which reduces the number of power conversion stages, reduces the number of power switches, and reduces the overall volume and cost of the system. In addition, a carrier-based time-sharing space vector modulation strategy is proposed to solve the problem of two output couplings of MP-TLC under SPWM modulation, so that the two output ports can work relatively independently. Compared with the traditional SVPWM modulation strategy, the carrier-based time-sharing space vector modulation strategy omits many trigonometric function calculation processes, which effectively improves the calculation speed of the algorithm. This article also presents a voltage-pumping DC-DC converter for the DC boost link in a photovoltaic micro-grid system. The converter can obtain a high voltage gain at a very low duty cycle and is suitable for a wider range of photovoltaic cell voltage input. The experimental results verify the effectiveness of the wide voltage input photovoltaic microgrid system based on MP-TLC.
- 5 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 165678-165691
Open AccessWide-Voltage Input Photovoltaic Microgrid System Based on Multi-Port Three-Level Converter
This article presents a photovoltaic micro-grid system structure with multiport three-level converter(MP-TLC). In this structure, two AC power supplies/loads with different operating amplitudes and frequencies can be directly connected through MP-TLC without multiple power conversion units. Compared with the traditional configuration, the structure of the multi-port converter photovoltaic microgrid system operates under a multi-level voltage, which reduces the number of power conversion stages, reduces the number of power switches, and reduces the overall volume and cost of the system. In addition, a carrier-based time-sharing space vector modulation strategy is proposed to solve the problem of two output couplings of MP-TLC under SPWM modulation, so that the two output ports can work relatively independently. Compared with the traditional SVPWM modulation strategy, the carrier-based time-sharing space vector modulation strategy omits many trigonometric function calculation processes, which effectively improves the calculation speed of the algorithm. This article also presents a voltage-pumping DC-DC converter for the DC boost link in a photovoltaic micro-grid system. The converter can obtain a high voltage gain at a very low duty cycle and is suitable for a wider range of photovoltaic cell voltage input. The experimental results verify the effectiveness of the wide voltage input photovoltaic microgrid system based on MP-TLC.
- Open Access
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 50377-50389
Control Strategy for Four-Leg Nine-Switch Inverter Under Unbalanced Loads
On account of that nine-switch inverter (NSI) cannot supply symmetrical voltages to unbalanced loads, based on the NSI, N-phase leg is added to the neutral points of the loads, which forms a four-leg nine-switch inverter (FLNSI). The neutral point voltages under unbalanced loads are analysed and derived by space vector pulse width modulation (SVPWM) strategy for calculating the duty ratio of N-phase leg. While the calculations of other three-phase legs duty ratios of SVPWM method remain unchanged. Although SVPWM method can realize FLNSI outputs symmetrical voltages for unbalanced loads, it needs trigonometric function calculation and sector judgements. The carrier-based pulse width modulation (CBPWM) strategy is proposed for the sake of simplifying SVPWM. All of the duty ratios are used to calculate modulation waves of FLNSI. Compare the modulation waves with a carrier, which can control the neutral point voltages as corresponding zero-sequence voltages. Therefore, two groups of three-phase symmetrical sinusoidal voltages are obtained under both balanced loads and unbalanced loads. Finally, the experimental results are given to show the advantages of FLNSI topology and to validate of the effectiveness of the applied modulation strategy.
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 50377-50389
Open AccessControl Strategy for Four-Leg Nine-Switch Inverter Under Unbalanced Loads
On account of that nine-switch inverter (NSI) cannot supply symmetrical voltages to unbalanced loads, based on the NSI, N-phase leg is added to the neutral points of the loads, which forms a four-leg nine-switch inverter (FLNSI). The neutral point voltages under unbalanced loads are analysed and derived by space vector pulse width modulation (SVPWM) strategy for calculating the duty ratio of N-phase leg. While the calculations of other three-phase legs duty ratios of SVPWM method remain unchanged. Although SVPWM method can realize FLNSI outputs symmetrical voltages for unbalanced loads, it needs trigonometric function calculation and sector judgements. The carrier-based pulse width modulation (CBPWM) strategy is proposed for the sake of simplifying SVPWM. All of the duty ratios are used to calculate modulation waves of FLNSI. Compare the modulation waves with a carrier, which can control the neutral point voltages as corresponding zero-sequence voltages. Therefore, two groups of three-phase symmetrical sinusoidal voltages are obtained under both balanced loads and unbalanced loads. Finally, the experimental results are given to show the advantages of FLNSI topology and to validate of the effectiveness of the applied modulation strategy.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Design of PFC in Wireless Charging System for Electric Vehicle
A power factor correction (PFC) circuit is constructed, based on average period compensation method(APCM) in this paper. The cut-off frequency 2kHz and 10Hz are closed for current loop and voltage loop, and the phase margin of each loop is 80 degrees. By contrasting the THD of fundamental wave calculated to the 40th and the peak value of voltage ripple wave, PI values and transfer functions of both current loop and voltage loop are got. Then the input current and output voltage in PFC steady operation are simulated, and results are in accord with the small-signal model. In Simulink, the output capacitance is charged in advance and saturation controller is adopted, by which the overshoot of output voltage decreases by 6.3%, and the THD of input current is only 3.76%, which meet the demands for power-factor correction in wireless charging system for EV.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Design of PFC in Wireless Charging System for Electric Vehicle
A power factor correction (PFC) circuit is constructed, based on average period compensation method(APCM) in this paper. The cut-off frequency 2kHz and 10Hz are closed for current loop and voltage loop, and the phase margin of each loop is 80 degrees. By contrasting the THD of fundamental wave calculated to the 40th and the peak value of voltage ripple wave, PI values and transfer functions of both current loop and voltage loop are got. Then the input current and output voltage in PFC steady operation are simulated, and results are in accord with the small-signal model. In Simulink, the output capacitance is charged in advance and saturation controller is adopted, by which the overshoot of output voltage decreases by 6.3%, and the THD of input current is only 3.76%, which meet the demands for power-factor correction in wireless charging system for EV.