Emily S. Savela
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Emily S. Savela has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Rustem F. Ismagilov
California Institute of Technology
7 shared publications - Alexander Viloria Winnett
California Institute of Technology
6 shared publications - Matthew M. Cooper
California Institute of Technology, Pasadena, California, USA
6 shared publications - Jacob T. Barlow
California Institute of Technology, Pasadena, California, USA
5 shared publications - Michael K. Porter
California Institute of Technology
5 shared publications - Natasha Shelby
Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
5 shared publications
Latest Publications
- Open Access
- 21 December 2022
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 10 (6) , e0387322
Morning SARS-CoV-2 Testing Yields Better Detection of Infection Due to Higher Viral Loads in Saliva and Nasal Swabs upon Waking
Our findings suggest that collecting saliva and nasal swab specimens in the morning immediately after waking yields higher SARS-CoV-2 viral loads than collection later in the day. The higher viral loads from morning specimen collection are predicted to significantly improve detection of SARS-CoV-2 in symptomatic individuals, particularly when using moderate- to low-analytical-sensitivity COVID-19 diagnostic tests, such as rapid antigen tests.
- 21 December 2022
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 10 (6) , e0387322
Open AccessMorning SARS-CoV-2 Testing Yields Better Detection of Infection Due to Higher Viral Loads in Saliva and Nasal Swabs upon Waking
Our findings suggest that collecting saliva and nasal swab specimens in the morning immediately after waking yields higher SARS-CoV-2 viral loads than collection later in the day. The higher viral loads from morning specimen collection are predicted to significantly improve detection of SARS-CoV-2 in symptomatic individuals, particularly when using moderate- to low-analytical-sensitivity COVID-19 diagnostic tests, such as rapid antigen tests.
- Open Access
Morning SARS-CoV-2 testing yields better detection of infection due to higher viral loads in saliva and nasal swabs upon waking
Background: The analytical sensitivities of SARS-CoV-2 diagnostic tests span 6 orders of magnitude. Optimizing sample-collection methods to achieve the most reliable detection for a given sensitivity would increase the effectiveness of testing and minimize COVID-19 outbreaks. Methods: From September 2020 to April 2021 we performed a household-transmission study in which participants self-collected samples every morning and evening throughout acute SARS-CoV-2 infection. Seventy mildly symptomatic participants collected saliva and, of those, 29 also collected nasal-swab samples. Viral load was quantified in 1194 saliva and 661 nasal-swab samples using a high-analytical-sensitivity RT-qPCR assay (LOD, 1,000 SARS-CoV-2 RNA copies/mL). Findings: Viral loads in both saliva and nasal-swab samples were significantly higher in morning-collected samples than evening-collected samples after symptom onset. We used these quantitative measurements to infer which diagnostic tests would have detected infection (based on sample type and test analytical sensitivity). We find that morning collection would have resulted in significantly improved detection and that this advantage would be most pronounced for tests with low to moderate analytical sensitivity, which would likely have missed infections if sampling in the evening. Interpretation: Collecting samples for COVID-19 testing in the morning offers a simple and low-cost improvement to clinical diagnostic sensitivity of low- to moderate-analytical-sensitivity tests. The phenomenon of higher viral loads in the morning may also have implications related to when transmission is more likely to occur. Funding: Bill & Melinda Gates Foundation, Ronald and Maxine Linde Center for New Initiatives (Caltech), Jacobs Institute for Molecular Engineering for Medicine (Caltech) RESEARCH IN CONTEXT: Evidence before this study: Reliable COVID-19 diagnostic testing is critical to reducing transmission of SARS-CoV-2 and reducing cases of severe or fatal disease, particularly in areas with limited vaccine access or uptake. Saliva and anterior-nares nasal swabs are common sample types; however, different diagnostic tests using these sample types have a range of analytical sensitivities spanning 6 orders of magnitude, with limits of detection (LODs) between 10 2 and 10 8 genomic copy equivalents of SARS-CoV-2 RNA (copies) per mL of sample. Due to limitations in clinical laboratory capacity, many low-resource settings rely on COVID-19 tests that fall on the moderate (LODs of 10 4 to 10 5 copies/mL) to lower (LODs of 10 5 to 10 8 copies/mL) end of this spectrum of analytical sensitivity. Alterations in sample collection methods, including time of sample collection, may improve the performance of these diagnostics. Added value of this study: This study quantifies viral loads from saliva and nasal-swab samples that were longitudinally self-collected by symptomatic patients in the morning immediately after waking and in the evening just prior to sleeping throughout the course of acute SARS-CoV-2 infection. The study cohort was composed of mildly or moderately symptomatic individuals (outpatients). This analysis demonstrates significantly higher viral loads in samples collected in the morning, relative to those collected in the evening. When using moderate to lower analytical sensitivity test methods, these loads are inferred to result in significantly better detection of infected individuals in the morning. Implications of available evidence: These findings suggest that samples collected in the morning immediately after waking will better detect SARS-CoV-2 infection in symptomatic individuals tested by moderate to lower analytical sensitivity COVID-19 diagnostic tests (LODs at or above 10 4 viral copies per mL of sample), such as many rapid antigen tests currently available.
Open AccessMorning SARS-CoV-2 testing yields better detection of infection due to higher viral loads in saliva and nasal swabs upon waking
Background: The analytical sensitivities of SARS-CoV-2 diagnostic tests span 6 orders of magnitude. Optimizing sample-collection methods to achieve the most reliable detection for a given sensitivity would increase the effectiveness of testing and minimize COVID-19 outbreaks. Methods: From September 2020 to April 2021 we performed a household-transmission study in which participants self-collected samples every morning and evening throughout acute SARS-CoV-2 infection. Seventy mildly symptomatic participants collected saliva and, of those, 29 also collected nasal-swab samples. Viral load was quantified in 1194 saliva and 661 nasal-swab samples using a high-analytical-sensitivity RT-qPCR assay (LOD, 1,000 SARS-CoV-2 RNA copies/mL). Findings: Viral loads in both saliva and nasal-swab samples were significantly higher in morning-collected samples than evening-collected samples after symptom onset. We used these quantitative measurements to infer which diagnostic tests would have detected infection (based on sample type and test analytical sensitivity). We find that morning collection would have resulted in significantly improved detection and that this advantage would be most pronounced for tests with low to moderate analytical sensitivity, which would likely have missed infections if sampling in the evening. Interpretation: Collecting samples for COVID-19 testing in the morning offers a simple and low-cost improvement to clinical diagnostic sensitivity of low- to moderate-analytical-sensitivity tests. The phenomenon of higher viral loads in the morning may also have implications related to when transmission is more likely to occur. Funding: Bill & Melinda Gates Foundation, Ronald and Maxine Linde Center for New Initiatives (Caltech), Jacobs Institute for Molecular Engineering for Medicine (Caltech) RESEARCH IN CONTEXT: Evidence before this study: Reliable COVID-19 diagnostic testing is critical to reducing transmission of SARS-CoV-2 and reducing cases of severe or fatal disease, particularly in areas with limited vaccine access or uptake. Saliva and anterior-nares nasal swabs are common sample types; however, different diagnostic tests using these sample types have a range of analytical sensitivities spanning 6 orders of magnitude, with limits of detection (LODs) between 10 2 and 10 8 genomic copy equivalents of SARS-CoV-2 RNA (copies) per mL of sample. Due to limitations in clinical laboratory capacity, many low-resource settings rely on COVID-19 tests that fall on the moderate (LODs of 10 4 to 10 5 copies/mL) to lower (LODs of 10 5 to 10 8 copies/mL) end of this spectrum of analytical sensitivity. Alterations in sample collection methods, including time of sample collection, may improve the performance of these diagnostics. Added value of this study: This study quantifies viral loads from saliva and nasal-swab samples that were longitudinally self-collected by symptomatic patients in the morning immediately after waking and in the evening just prior to sleeping throughout the course of acute SARS-CoV-2 infection. The study cohort was composed of mildly or moderately symptomatic individuals (outpatients). This analysis demonstrates significantly higher viral loads in samples collected in the morning, relative to those collected in the evening. When using moderate to lower analytical sensitivity test methods, these loads are inferred to result in significantly better detection of infected individuals in the morning. Implications of available evidence: These findings suggest that samples collected in the morning immediately after waking will better detect SARS-CoV-2 infection in symptomatic individuals tested by moderate to lower analytical sensitivity COVID-19 diagnostic tests (LODs at or above 10 4 viral copies per mL of sample), such as many rapid antigen tests currently available.
- Open Access
- 16 February 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (2)
Quantitative SARS-CoV-2 Viral-Load Curves in Paired Saliva Samples and Nasal Swabs Inform Appropriate Respiratory Sampling Site and Analytical Test Sensitivity Required for Earliest Viral Detection
Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and presymptomatic transmission, curb the spread of variants, and maximize treatment efficacy. Low-analytical-sensitivity nasal-swab testing is commonly used for surveillance and symptomatic testing, but the ability of these tests to detect the earliest stages of infection has not been established.
- 16 February 2022
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 60 (2)
Open AccessQuantitative SARS-CoV-2 Viral-Load Curves in Paired Saliva Samples and Nasal Swabs Inform Appropriate Respiratory Sampling Site and Analytical Test Sensitivity Required for Earliest Viral Detection
Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and presymptomatic transmission, curb the spread of variants, and maximize treatment efficacy. Low-analytical-sensitivity nasal-swab testing is commonly used for surveillance and symptomatic testing, but the ability of these tests to detect the earliest stages of infection has not been established.
- Open Access
Quantitative SARS-CoV-2 viral-load curves in paired saliva and nasal swabs inform appropriate respiratory sampling site and analytical test sensitivity required for earliest viral detection
Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and pre-symptomatic spread of COVID-19, curb the spread of viral variants by travelers, and maximize efficacy of therapeutic treatments. We designed a study to evaluate the preferred test sensitivity and sample type (saliva and nasal swab) for detecting early infections of COVID-19. We performed a case-ascertained study to monitor household contacts of individuals recently diagnosed with a SARS-CoV-2 infection. From those individuals, we obtained twice-daily self-collected anterior-nares nasal swabs and saliva samples and quantified SARS-CoV-2 RNA viral loads in those samples using high-sensitivity RT-qPCR and RT-ddPCR assays. We found that SARS-CoV-2 RNA first appears in saliva and then in nasal-swab samples. A high-sensitivity (limit of detection of ∼103 copies/mL) RNA test detected SARS-CoV-2 virus in saliva 1.5 to 4.5 days before the viral load in the paired nasal-swab samples exceeded the limit of detection of low-sensitivity tests. It was possible to observe a high (>107-108 copies/mL) viral load in saliva samples while the paired nasal swab was either negative or had low (∼103 copies/mL) viral load. Our results indicate that both sampling site and test sensitivity must be considered to ensure early detection of SARS-CoV-2 infection: high-sensitivity tests that use saliva can detect SARS-CoV-2 infection days earlier than low-sensitivity tests that use nasal swabs. Furthermore, early in the infection, low-sensitivity tests that use nasal swabs may miss SARS-CoV-2-positive individuals with very high and potentially infectious viral loads in saliva.
Open AccessQuantitative SARS-CoV-2 viral-load curves in paired saliva and nasal swabs inform appropriate respiratory sampling site and analytical test sensitivity required for earliest viral detection
Early detection of SARS-CoV-2 infection is critical to reduce asymptomatic and pre-symptomatic spread of COVID-19, curb the spread of viral variants by travelers, and maximize efficacy of therapeutic treatments. We designed a study to evaluate the preferred test sensitivity and sample type (saliva and nasal swab) for detecting early infections of COVID-19. We performed a case-ascertained study to monitor household contacts of individuals recently diagnosed with a SARS-CoV-2 infection. From those individuals, we obtained twice-daily self-collected anterior-nares nasal swabs and saliva samples and quantified SARS-CoV-2 RNA viral loads in those samples using high-sensitivity RT-qPCR and RT-ddPCR assays. We found that SARS-CoV-2 RNA first appears in saliva and then in nasal-swab samples. A high-sensitivity (limit of detection of ∼103 copies/mL) RNA test detected SARS-CoV-2 virus in saliva 1.5 to 4.5 days before the viral load in the paired nasal-swab samples exceeded the limit of detection of low-sensitivity tests. It was possible to observe a high (>107-108 copies/mL) viral load in saliva samples while the paired nasal swab was either negative or had low (∼103 copies/mL) viral load. Our results indicate that both sampling site and test sensitivity must be considered to ensure early detection of SARS-CoV-2 infection: high-sensitivity tests that use saliva can detect SARS-CoV-2 infection days earlier than low-sensitivity tests that use nasal swabs. Furthermore, early in the infection, low-sensitivity tests that use nasal swabs may miss SARS-CoV-2-positive individuals with very high and potentially infectious viral loads in saliva.
- Open Access
SARS-CoV-2 Viral Load in Saliva Rises Gradually and to Moderate Levels in Some Humans
Transmission of SARS-CoV-2 in community settings often occurs before symptom onset, therefore testing strategies that can reliably detect people in the early phase of infection are urgently needed. Early detection of SARS-CoV-2 infection is especially critical to protect vulnerable populations who require frequent interactions with caretakers. Rapid COVID-19 tests have been proposed as an attractive strategy for surveillance, however a limitation of most rapid tests is their low sensitivity. Low-sensitivity tests are comparable to high sensitivity tests in detecting early infections when two assumptions are met: (1) viral load rises quickly (within hours) after infection and (2) viral load reaches and sustains high levels (>10 5 – 10 6 RNA copies/mL). However, there are no human data testing these assumptions. In this study, we document a case of presymptomatic household transmission from a healthy young adult to a sibling and a parent. Participants prospectively provided twice-daily saliva samples. Samples were analyzed by RT-qPCR and RT-ddPCR and we measured the complete viral load profiles throughout the course of infection of the sibling and parent. This study provides evidence that in at least some human cases of SARS-CoV-2, viral load rises slowly (over days, not hours) and not to such high levels to be detectable reliably by any low-sensitivity test. Additional viral load profiles from different samples types across a broad demographic must be obtained to describe the early phase of infection and determine which testing strategies will be most effective for identifying SARS-CoV-2 infection before transmission can occur. One sentence summary: In some human infections, SARS-CoV-2 viral load rises slowly (over days) and remains near the limit of detection of rapid, low-sensitivity tests.
Open AccessSARS-CoV-2 Viral Load in Saliva Rises Gradually and to Moderate Levels in Some Humans
Transmission of SARS-CoV-2 in community settings often occurs before symptom onset, therefore testing strategies that can reliably detect people in the early phase of infection are urgently needed. Early detection of SARS-CoV-2 infection is especially critical to protect vulnerable populations who require frequent interactions with caretakers. Rapid COVID-19 tests have been proposed as an attractive strategy for surveillance, however a limitation of most rapid tests is their low sensitivity. Low-sensitivity tests are comparable to high sensitivity tests in detecting early infections when two assumptions are met: (1) viral load rises quickly (within hours) after infection and (2) viral load reaches and sustains high levels (>10 5 – 10 6 RNA copies/mL). However, there are no human data testing these assumptions. In this study, we document a case of presymptomatic household transmission from a healthy young adult to a sibling and a parent. Participants prospectively provided twice-daily saliva samples. Samples were analyzed by RT-qPCR and RT-ddPCR and we measured the complete viral load profiles throughout the course of infection of the sibling and parent. This study provides evidence that in at least some human cases of SARS-CoV-2, viral load rises slowly (over days, not hours) and not to such high levels to be detectable reliably by any low-sensitivity test. Additional viral load profiles from different samples types across a broad demographic must be obtained to describe the early phase of infection and determine which testing strategies will be most effective for identifying SARS-CoV-2 infection before transmission can occur. One sentence summary: In some human infections, SARS-CoV-2 viral load rises slowly (over days) and remains near the limit of detection of rapid, low-sensitivity tests.
- Open Access
- 19 March 2020
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 18 (3) , e3000651
Surfactant-enhanced DNA accessibility to nuclease accelerates phenotypic β-lactam antibiotic susceptibility testing of Neisseria gonorrhoeae
Rapid antibiotic susceptibility testing (AST) for Neisseria gonorrhoeae (Ng) is critically needed to counter widespread antibiotic resistance. Detection of nucleic acids in genotypic AST can be rapid, but it has not been successful for β-lactams (the largest antibiotic class used to treat Ng). Rapid phenotypic AST for Ng is challenged by the pathogen’s slow doubling time and the lack of methods to quickly quantify the pathogen’s response to β-lactams. Here, we asked two questions: (1) Is it possible to use nucleic acid quantification to measure the β-lactam susceptibility phenotype of Ng very rapidly, using antibiotic-exposure times much shorter than the 1- to 2-h doubling time of Ng? (2) Would such short-term antibiotic exposures predict the antibiotic resistance profile of Ng measured by plate growth assays over multiple days? To answer these questions, we devised an innovative approach for performing a rapid phenotypic AST that measures DNA accessibility to exogenous nucleases after exposure to β-lactams (termed nuclease-accessibility AST [nuc-aAST]). We showed that DNA in antibiotic-susceptible cells has increased accessibility upon exposure to β-lactams and that a judiciously chosen surfactant permeabilized the outer membrane and enhanced this effect. We tested penicillin, cefixime, and ceftriaxone and found good agreement between the results of the nuc-aAST after 15–30 min of antibiotic exposure and the results of the gold-standard culture-based AST measured over days. These results provide a new pathway toward developing a critically needed phenotypic AST for Ng and additional global-health threats.
- 19 March 2020
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 18 (3) , e3000651
Open AccessSurfactant-enhanced DNA accessibility to nuclease accelerates phenotypic β-lactam antibiotic susceptibility testing of Neisseria gonorrhoeae
Rapid antibiotic susceptibility testing (AST) for Neisseria gonorrhoeae (Ng) is critically needed to counter widespread antibiotic resistance. Detection of nucleic acids in genotypic AST can be rapid, but it has not been successful for β-lactams (the largest antibiotic class used to treat Ng). Rapid phenotypic AST for Ng is challenged by the pathogen’s slow doubling time and the lack of methods to quickly quantify the pathogen’s response to β-lactams. Here, we asked two questions: (1) Is it possible to use nucleic acid quantification to measure the β-lactam susceptibility phenotype of Ng very rapidly, using antibiotic-exposure times much shorter than the 1- to 2-h doubling time of Ng? (2) Would such short-term antibiotic exposures predict the antibiotic resistance profile of Ng measured by plate growth assays over multiple days? To answer these questions, we devised an innovative approach for performing a rapid phenotypic AST that measures DNA accessibility to exogenous nucleases after exposure to β-lactams (termed nuclease-accessibility AST [nuc-aAST]). We showed that DNA in antibiotic-susceptible cells has increased accessibility upon exposure to β-lactams and that a judiciously chosen surfactant permeabilized the outer membrane and enhanced this effect. We tested penicillin, cefixime, and ceftriaxone and found good agreement between the results of the nuc-aAST after 15–30 min of antibiotic exposure and the results of the gold-standard culture-based AST measured over days. These results provide a new pathway toward developing a critically needed phenotypic AST for Ng and additional global-health threats.
- Open Access
- 19 March 2020
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 18 (3) , e3000652
Differential DNA accessibility to polymerase enables 30-minute phenotypic β-lactam antibiotic susceptibility testing of carbapenem-resistant Enterobacteriaceae
The rise in carbapenem-resistant Enterobacteriaceae (CRE) infections has created a global health emergency, underlining the critical need to develop faster diagnostics to treat swiftly and correctly. Although rapid pathogen-identification (ID) tests are being developed, gold-standard antibiotic susceptibility testing (AST) remains unacceptably slow (1–2 d), and innovative approaches for rapid phenotypic ASTs for CREs are urgently needed. Motivated by this need, in this manuscript we tested the hypothesis that upon treatment with β-lactam antibiotics, susceptible Enterobacteriaceae isolates would become sufficiently permeabilized, making some of their DNA accessible to added polymerase and primers. Further, we hypothesized that this accessible DNA would be detectable directly by isothermal amplification methods that do not fully lyse bacterial cells. We build on these results to develop the polymerase-accessibility AST (pol-aAST), a new phenotypic approach for β-lactams, the major antibiotic class for gram-negative infections. We test isolates of the 3 causative pathogens of CRE infections using ceftriaxone (CRO), ertapenem (ETP), and meropenem (MEM) and demonstrate agreement with gold-standard AST. Importantly, pol-aAST correctly categorized resistant isolates that are undetectable by current genotypic methods (negative for β-lactamase genes or lacking predictive genotypes). We also test contrived and clinical urine samples. We show that the pol-aAST can be performed in 30 min sample-to-answer using contrived urine samples and has the potential to be performed directly on clinical urine specimens.
- 19 March 2020
- Published by Public Library of Science (PLoS) in PLOS Biology
- Vol. 18 (3) , e3000652
Open AccessDifferential DNA accessibility to polymerase enables 30-minute phenotypic β-lactam antibiotic susceptibility testing of carbapenem-resistant Enterobacteriaceae
The rise in carbapenem-resistant Enterobacteriaceae (CRE) infections has created a global health emergency, underlining the critical need to develop faster diagnostics to treat swiftly and correctly. Although rapid pathogen-identification (ID) tests are being developed, gold-standard antibiotic susceptibility testing (AST) remains unacceptably slow (1–2 d), and innovative approaches for rapid phenotypic ASTs for CREs are urgently needed. Motivated by this need, in this manuscript we tested the hypothesis that upon treatment with β-lactam antibiotics, susceptible Enterobacteriaceae isolates would become sufficiently permeabilized, making some of their DNA accessible to added polymerase and primers. Further, we hypothesized that this accessible DNA would be detectable directly by isothermal amplification methods that do not fully lyse bacterial cells. We build on these results to develop the polymerase-accessibility AST (pol-aAST), a new phenotypic approach for β-lactams, the major antibiotic class for gram-negative infections. We test isolates of the 3 causative pathogens of CRE infections using ceftriaxone (CRO), ertapenem (ETP), and meropenem (MEM) and demonstrate agreement with gold-standard AST. Importantly, pol-aAST correctly categorized resistant isolates that are undetectable by current genotypic methods (negative for β-lactamase genes or lacking predictive genotypes). We also test contrived and clinical urine samples. We show that the pol-aAST can be performed in 30 min sample-to-answer using contrived urine samples and has the potential to be performed directly on clinical urine specimens.