Yucong Xue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yucong Xue has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Yifan Fan
5 shared publicationsJian Ge
4 shared publicationsJiang Lu
2 shared publications- Kang Zhao
Department of Architecture, Zhejiang University
2 shared publications Yidong Qian
Huahui Engineering Design Group Co., Ltd, Shaoxing, 312000, China
2 shared publicationsJiajie Hong
Tsinghua University
1 shared publication
Latest Publications
- 7 October 2022
- Published by Elsevier in Energy and Buildings
- Vol. 277
Facilitator of moisture accumulation in building envelopes and its influences on condensation and mould growth
- 7 October 2022
- Published by Elsevier in Energy and Buildings
- Vol. 277
Facilitator of moisture accumulation in building envelopes and its influences on condensation and mould growth
- Open Access
- 21 June 2022
- Published by UCL Press in UCL Open Environment Preprint
The moisture distribution in wall-to-floor thermal bridges and its influence on mould growth
Moisture in the building envelopes increase the energy consumption of buildings and induce mould growth, which may be amplified within the area of thermal bridges due to their different hygrothermal properties and complex structures. In this study, we aimed to (1) reveal the moisture distribution in the typical thermal bridge (i.e., wall-to-floor thermal bridge, WFTB) and its surrounding area, and (2) investigate the mould growth in the building envelope that includes both WFTB and the main part of the wall, in a humid and hot summer cold winter region of China (Hangzhou City). The transient numerical simulations that lasted for five years were performed to model the moisture distribution. Simulated results indicate that the moisture distribution presents significant seasonal and spatial differences due to the WFTB. The areas where moisture accumulates have a higher risk of mould growth. The thermal insulation layer laid on the exterior surface of WFTB can reduce the overall humidity while uneven moisture distribution, which may promote mould growth and water vapour condensation.
- 21 June 2022
- Published by UCL Press in UCL Open Environment Preprint
Open AccessThe moisture distribution in wall-to-floor thermal bridges and its influence on mould growth
Moisture in the building envelopes increase the energy consumption of buildings and induce mould growth, which may be amplified within the area of thermal bridges due to their different hygrothermal properties and complex structures. In this study, we aimed to (1) reveal the moisture distribution in the typical thermal bridge (i.e., wall-to-floor thermal bridge, WFTB) and its surrounding area, and (2) investigate the mould growth in the building envelope that includes both WFTB and the main part of the wall, in a humid and hot summer cold winter region of China (Hangzhou City). The transient numerical simulations that lasted for five years were performed to model the moisture distribution. Simulated results indicate that the moisture distribution presents significant seasonal and spatial differences due to the WFTB. The areas where moisture accumulates have a higher risk of mould growth. The thermal insulation layer laid on the exterior surface of WFTB can reduce the overall humidity while uneven moisture distribution, which may promote mould growth and water vapour condensation.
- Open Access
- 6 March 2022
- Published by UCL Press in UCL Open Environment Preprint
The moisture distribution in wall-to-floor thermal bridges and its influence on mould growth
Moisture in the building envelopes increase the energy consumption of buildings and induce mould growth, which may be amplified within the area of thermal bridges due to their different hygrothermal properties and complex structures. In this study, we aimed to (1) reveal the moisture distribution in the typical thermal bridges (i.e., wall-to-floor thermal bridge, WFTB) and its surrounding area, and (2) investigate the mould growth in the building envelope that includes both WFTB and the main part of the wall. The transient numerical simulations that lasted for five years were performed to model the moisture distribution. Simulated results indicate that the moisture distribution presents significant seasonal and spatial differences due to the WFTB. The areas where moisture accumulates have a higher risk of mould growth. The thermal insulation layer laid on the exterior surface of WFTB can reduce the overall humidity while uneven moisture distribution, which may promote mould growth and water vapour condensation.
- 6 March 2022
- Published by UCL Press in UCL Open Environment Preprint
Open AccessThe moisture distribution in wall-to-floor thermal bridges and its influence on mould growth
Moisture in the building envelopes increase the energy consumption of buildings and induce mould growth, which may be amplified within the area of thermal bridges due to their different hygrothermal properties and complex structures. In this study, we aimed to (1) reveal the moisture distribution in the typical thermal bridges (i.e., wall-to-floor thermal bridge, WFTB) and its surrounding area, and (2) investigate the mould growth in the building envelope that includes both WFTB and the main part of the wall. The transient numerical simulations that lasted for five years were performed to model the moisture distribution. Simulated results indicate that the moisture distribution presents significant seasonal and spatial differences due to the WFTB. The areas where moisture accumulates have a higher risk of mould growth. The thermal insulation layer laid on the exterior surface of WFTB can reduce the overall humidity while uneven moisture distribution, which may promote mould growth and water vapour condensation.
- Open Access
- 1 January 2022
- Published by UCL Press in UCL Open Environment
- Vol. 4, e042
The moisture distribution in wall-to-floor thermal bridges and its influence on mould growth
Moisture in building envelopes increases the energy consumption of buildings and induces mould growth, which may be amplified within the area of thermal bridges due to their different hygrothermal properties and complex structures. In this study, we aimed to (1) reveal the moisture distribution in the typical thermal bridge (i.e., wall-to-floor thermal bridge, WFTB) and its surrounding area and (2) investigate the mould growth in a building envelope that includes both a WFTB and the main part of a wall, in a humid and hot summer/cold winter region of China (Hangzhou City). The transient numerical simulations which lasted for 5 years were performed to model the moisture distribution. Simulated results indicate that the moisture distribution presents significant seasonal and spatial differences due to the WFTB. The areas where moisture accumulates have a higher risk of mould growth. The thermal insulation layer laid on the exterior surface of a WFTB can reduce the overall humidity while uneven moisture distribution may promote mould growth and water vapour condensation.
- 1 January 2022
- Published by UCL Press in UCL Open Environment
- Vol. 4, e042
Open AccessThe moisture distribution in wall-to-floor thermal bridges and its influence on mould growth
Moisture in building envelopes increases the energy consumption of buildings and induces mould growth, which may be amplified within the area of thermal bridges due to their different hygrothermal properties and complex structures. In this study, we aimed to (1) reveal the moisture distribution in the typical thermal bridge (i.e., wall-to-floor thermal bridge, WFTB) and its surrounding area and (2) investigate the mould growth in a building envelope that includes both a WFTB and the main part of a wall, in a humid and hot summer/cold winter region of China (Hangzhou City). The transient numerical simulations which lasted for 5 years were performed to model the moisture distribution. Simulated results indicate that the moisture distribution presents significant seasonal and spatial differences due to the WFTB. The areas where moisture accumulates have a higher risk of mould growth. The thermal insulation layer laid on the exterior surface of a WFTB can reduce the overall humidity while uneven moisture distribution may promote mould growth and water vapour condensation.
- 1 May 2020
- Published by Elsevier in Journal of Building Engineering
- Vol. 29, 101196
Improved operating strategy for air-conditioning systems based on the indoor occupancy rate
- 1 May 2020
- Published by Elsevier in Journal of Building Engineering
- Vol. 29, 101196
Improved operating strategy for air-conditioning systems based on the indoor occupancy rate
- 20 March 2020
- Published by Springer Nature
- p. 619-628
Data Association Mining for Identifying Cooling Energy Waste Patterns and Corresponding Improving Suggestion
- 20 March 2020
- Published by Springer Nature
- p. 619-628
Data Association Mining for Identifying Cooling Energy Waste Patterns and Corresponding Improving Suggestion