HTHongtian Tian

Hongtian Tian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hongtian Tian has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Jinfeng Xu

    Department of Ultrasound Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology) Shenzhen Guangdong China

    3 shared publications
  • Huaiyu Wu

    Department of Ultrasound, Shenzhen People's Hospital, The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen 518020, Guangdong, China

    2 shared publications
  • Weiyu Liang

    Department of Ultrasound, First Affiliated Hospital of Southern University of Science and Technology, Second Clinical College of Jinan University, Shenzhen Medical Ultrasond Engineering Center, Shenzhen People's Hospital.

    2 shared publications
  • Chen Cui

    Research and development department, Illuminate, LLC, Shenzhen, China

    1 shared publication
  • Di Song

    Department of Ultrasound, First Affiliated Hospital of Southern University of Science and Technology, Second Clinical College of Jinan University, Shenzhen Medical Ultrasond Engineering Center, Shenzhen People's Hospital.

    1 shared publication
  • Fajin Dong

    The Second Clinical Medical College, Jinan University, Shenzhen, China

    1 shared publication

Latest Publications

  • Open Access

    Artificial intelligence for non-mass breast lesions detection and classification on ultrasound images: a comparative study

    by Guoqiu Li, Hongtian Tian, Huaiyu Wu, Zhibin Huang, Keen Yang, Jian Li, Yuwei Luo, Siyuan Shi, Chen Cui, Jinfeng Xu, et al.

    Background: This retrospective study aims to validate the effectiveness of artificial intelligence (AI) to detect and classify non-mass breast lesions (NMLs) on ultrasound (US) images. Methods: A total of 228 patients with NMLs and 596 volunteers without breast lesions on US images were enrolled in the study from January 2020 to December 2022. The pathological results served as the gold standard for NMLs. Two AI models were developed to accurately detect and classify NMLs on US images, including DenseNet121_448 and MobileNet_448. To evaluate and compare the diagnostic performance of AI models, the area under the curve (AUC), accuracy, specificity and sensitivity was employed. Results: A total of 228 NMLs patients confirmed by postoperative pathology with 870 US images and 596 volunteers with 1003 US images were enrolled. In the detection experiment, the MobileNet_448 achieved the good performance in the testing set, with the AUC, accuracy, sensitivity, and specificity were 0.999 (95%CI: 0.997-1.000),96.5%,96.9% and 96.1%, respectively. It was no statistically significant compared to DenseNet121_448. In the classification experiment, the MobileNet_448 model achieved the highest diagnostic performance in the testing set, with the AUC, accuracy, sensitivity, and specificity were 0.837 (95%CI: 0.990-1.000), 70.5%, 80.3% and 74.6%, respectively. Conclusions: This study suggests that the AI models, particularly MobileNet_448, can effectively detect and classify NMLs in US images. This technique has the potential to improve early diagnostic accuracy for NMLs.


  • The role of grey-scale ultrasound in the diagnosis of adhesive capsulitis of the shoulder: a systematic review and meta-analysis

    by Huaiyu Wu, Hongtian Tian, Fajin Dong, Weiyu Liang, Di Song, Jieying Zeng, Zhimin Ding, Yang Shi, Hui Luo, Jinfeng Xu

    Aims: In this systematic review and meta-analysis, we discuss the value of grey-scale ultrasonography (US) in diagnosing adhesive capsulitis of the shoulder (ACS).Material and methods: We retrieved relevant studies from PubMed, Cochrane Library, and Embase before 8 April 2019. We selected 7 studies concerning 446 patients (490 shoulders) that used grey-scale US to diagnose ACS and magnetic resonance imaging (MRI) or arthroscopy as the reference standard. We assessed the diagnostic accuracy of US on the basis of combined sensitivity, specificity, likelihood ratio (LR), and the area under the summary receiver operating characteristic (SROC) curve (AUC).Results: The combined sensitivity, specificity, positive LR and negative LR were found to be 88% (95%CI: 74–95), 96% (95%CI: 88–99), 23.89 (95%CI: 6.31–90.51) and 0.12 (95%CI: 0.05–0.29), respectively. The AUC was 0.97 (95%CI: 0.96–0.98). ACS was diagnosed on the basis of four US features: coracohumeral ligament thickening, inferior capsule/axillary recess capsule thickening, rotator interval abnormality, and restriction of the range of motion. The corresponding sensitivities were 64.4 (95%CI: 48.8–78.1), 82.1 (95%CI: 73.8–88.7), 82.6 (95%CI: 74.1–89.2) and 94.3 (95%CI: 84.3–98.8), respectively, and specificities were 88.9 (95%CI: 76.0–96.3), 95.7 (95%CI: 90.3–98.6), 93.9 (95%CI: 89.8–96.7), and 90.9 (95%CI: 75.7–98.1), respectively.Conclusions: Our meta-analysis showed that grey-scale US plays a significant role in the diagnosis of ACS. Because of its high sensitivity and specificity, US can be added to the existing clinical diagnosis program.


  • Open Access

    Diagnostic performance of ultrasound for rotator cuff tears: a systematic review and meta-analysis

    by Weiyu Liang, Huaiyu Wu, Fajin Dong, Hongtian Tian, Jinfeng Xu

    Diagnostic performance of ultrasound for rotator cuff tears: a systematic review and meta-analysis