Cancan Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cancan Zhang has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Yuting Wu
Beijing Key Laboratory of Heat Transfer and Energy Conversion, Beijing University of Technology, Beijing, China
28 shared publicationsYanjun Du
Beijing Key Laboratory of Heat Transfer and Energy Conversion, Beijing University of Technology, Beijing, China
11 shared publicationsYuanwei Lu
9 shared publicationsDi Qi
6 shared publicationsSongtao Han
Beijing Key Laboratory of Heat Transfer and Energy Conversion, National User-Side Energy Storage Innovation Research and Development Center, Beijing University of Technology, Beijing, China
6 shared publicationsXu Feng
6 shared publications
Latest Publications
- 10 November 2026
- Published by Springer Nature in Journal of Thermal Science
- p. 1-14
Metal Powder-Filled Ceramic Heating Tube for High-Voltage Molten Salt Thermal Energy Storage
- 10 November 2026
- Published by Springer Nature in Journal of Thermal Science
- p. 1-14
Metal Powder-Filled Ceramic Heating Tube for High-Voltage Molten Salt Thermal Energy Storage
- 10 September 2026
- Published by Elsevier in Renewable Energy
- Vol. 276
A novel mothballed pipeline-based CAES system with low-melting-point molten salt TES: Dynamic characteristics and flexible operation
- 10 September 2026
- Published by Elsevier in Renewable Energy
- Vol. 276
A novel mothballed pipeline-based CAES system with low-melting-point molten salt TES: Dynamic characteristics and flexible operation
- Open Access
- 1 September 2026
- Published by KEAI Publishing in Journal of Pipeline Science and Engineering
Thermo-Economic Performance Analysis of a Mothballed Pipeline-Based CAES System
- 1 September 2026
- Published by KEAI Publishing in Journal of Pipeline Science and Engineering
Open AccessThermo-Economic Performance Analysis of a Mothballed Pipeline-Based CAES System
- 2 August 2026
- Published by Springer Nature
- p. 483-493
Characteristic Analysis of the Thermal Energy Storage Subsystem in Large-Scale TS-CAES System
- 2 August 2026
- Published by Springer Nature
- p. 483-493
Characteristic Analysis of the Thermal Energy Storage Subsystem in Large-Scale TS-CAES System
- 2 August 2026
- Published by Springer Nature
- p. 515-524
Study on the Physical Stability of Solar Salt Under Constant Temperature and Thermal Shock Conditions
- 2 August 2026
- Published by Springer Nature
- p. 515-524
Study on the Physical Stability of Solar Salt Under Constant Temperature and Thermal Shock Conditions
- 2 August 2026
- Published by Springer Nature
- p. 100-110
Phase Diagram Analysis and Experimental Study of Low Melting Point Molten Salt for Large Scale Thermal Energy Storage
- 2 August 2026
- Published by Springer Nature
- p. 100-110
Phase Diagram Analysis and Experimental Study of Low Melting Point Molten Salt for Large Scale Thermal Energy Storage
- Open Access
Numerical Investigation on the Thermal-Hydraulic Performance of Molten Salt in Internal Helically Finned Tubes
Molten salts have attracted considerable attention as heat transfer and thermal storage media in high-temperature energy systems, including concentrating solar power systems, advanced heat exchangers, and nuclear-related thermal systems. However, their relatively low thermal conductivity, high Prandtl number, and strong temperature-dependent viscosity may limit convective heat transfer performance and increase the difficulty of thermal-hydraulic design. Internally helically finned tubes have been widely used as passive heat transfer enhancement structures in conventional thermal systems, but their applicability to high-temperature molten-salt flows remains insufficiently understood. In this study, a three-dimensional numerical model was developed to investigate the thermal-hydraulic performance of a low-melting-point quaternary nitrate salt flowing through internally helically finned tubes. The effects of fin pitch, fin height, and helix angle were systematically examined over a Reynolds number range of 14,000–26,000. The results show that decreasing the fin pitch and increasing the helix angle enhance near-wall flow disturbance and improve convective heat transfer, while also increasing the pressure drop. The fin height exhibits a more pronounced trade-off effect: although larger fins increase the heat transfer coefficient, excessive fin height causes a substantial hydraulic penalty and weakens the overall performance. Based on the Performance Evaluation Criterion, the configuration with a fin pitch of 1.4 mm, fin height of 0.4 mm, and helix angle of 30° achieves the best overall thermal-hydraulic performance within the investigated parameter range, with a maximum PEC of 2.14. Compared with representative enhanced-tube configurations reported for molten-salt heat transfer, the internally helically finned tube shows competitive comprehensive performance. This work provides a numerical assessment of the feasibility and design sensitivity of internally helically finned tubes for molten-salt heat exchangers and offers useful guidance for the optimization of high-temperature thermal energy systems.
Open AccessNumerical Investigation on the Thermal-Hydraulic Performance of Molten Salt in Internal Helically Finned Tubes
Molten salts have attracted considerable attention as heat transfer and thermal storage media in high-temperature energy systems, including concentrating solar power systems, advanced heat exchangers, and nuclear-related thermal systems. However, their relatively low thermal conductivity, high Prandtl number, and strong temperature-dependent viscosity may limit convective heat transfer performance and increase the difficulty of thermal-hydraulic design. Internally helically finned tubes have been widely used as passive heat transfer enhancement structures in conventional thermal systems, but their applicability to high-temperature molten-salt flows remains insufficiently understood. In this study, a three-dimensional numerical model was developed to investigate the thermal-hydraulic performance of a low-melting-point quaternary nitrate salt flowing through internally helically finned tubes. The effects of fin pitch, fin height, and helix angle were systematically examined over a Reynolds number range of 14,000–26,000. The results show that decreasing the fin pitch and increasing the helix angle enhance near-wall flow disturbance and improve convective heat transfer, while also increasing the pressure drop. The fin height exhibits a more pronounced trade-off effect: although larger fins increase the heat transfer coefficient, excessive fin height causes a substantial hydraulic penalty and weakens the overall performance. Based on the Performance Evaluation Criterion, the configuration with a fin pitch of 1.4 mm, fin height of 0.4 mm, and helix angle of 30° achieves the best overall thermal-hydraulic performance within the investigated parameter range, with a maximum PEC of 2.14. Compared with representative enhanced-tube configurations reported for molten-salt heat transfer, the internally helically finned tube shows competitive comprehensive performance. This work provides a numerical assessment of the feasibility and design sensitivity of internally helically finned tubes for molten-salt heat exchangers and offers useful guidance for the optimization of high-temperature thermal energy systems.
- Open Access
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Thermodynamic and techno-economic evaluation of working-fluid suitability for Brayton-cycle pumped thermal electricity storage under engineering constraints
Working-fluid selection strongly affects the feasible operating range, thermodynamic performance, and economic viability of Brayton-cycle pumped thermal electricity storage (PTES), yet its role under realistic engineering constraints remains insufficiently clarified. In this study, a thermodynamic and techno-economic evaluation framework is developed for a 100 MW/6 h Brayton-cycle PTES system under a unified 920 K storage-temperature limit. Five representative working fluids, namely CO2, air, N2, Ar, and He, are compared through full-parameter feasible-condition screening, LCOS decomposition and sensitivity analysis, and comprehensive suitability evaluation. The results show that He and Ar are mainly restricted by excessive compression temperature rise, whereas CO2 is primarily constrained by near-critical heat-transfer matching. Under the 920 K boundary, CO2 achieves the highest round-trip efficiency of 66.92%, while He exhibits the lowest total investment of 65.14 M$ and the lowest LCOS of 0.08061 $/kWh under the adopted equipment-cost model. LCOS sensitivity analysis indicates that electricity price mainly amplifies the influence of round-trip efficiency, whereas discount rate and investment cost uncertainty primarily affect capital-intensive systems. Under an extended temperature boundary, air and N2 show stronger improvement potential owing to their higher temperature-efficiency sensitivities. Overall, working-fluid selection for Brayton-cycle PTES should be regarded as a boundary-dependent and preference-dependent decision that jointly considers feasible operation, thermodynamic performance, economic sensitivity, and temperature boundary adaptability.
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermodynamic and techno-economic evaluation of working-fluid suitability for Brayton-cycle pumped thermal electricity storage under engineering constraints
Working-fluid selection strongly affects the feasible operating range, thermodynamic performance, and economic viability of Brayton-cycle pumped thermal electricity storage (PTES), yet its role under realistic engineering constraints remains insufficiently clarified. In this study, a thermodynamic and techno-economic evaluation framework is developed for a 100 MW/6 h Brayton-cycle PTES system under a unified 920 K storage-temperature limit. Five representative working fluids, namely CO2, air, N2, Ar, and He, are compared through full-parameter feasible-condition screening, LCOS decomposition and sensitivity analysis, and comprehensive suitability evaluation. The results show that He and Ar are mainly restricted by excessive compression temperature rise, whereas CO2 is primarily constrained by near-critical heat-transfer matching. Under the 920 K boundary, CO2 achieves the highest round-trip efficiency of 66.92%, while He exhibits the lowest total investment of 65.14 M$ and the lowest LCOS of 0.08061 $/kWh under the adopted equipment-cost model. LCOS sensitivity analysis indicates that electricity price mainly amplifies the influence of round-trip efficiency, whereas discount rate and investment cost uncertainty primarily affect capital-intensive systems. Under an extended temperature boundary, air and N2 show stronger improvement potential owing to their higher temperature-efficiency sensitivities. Overall, working-fluid selection for Brayton-cycle PTES should be regarded as a boundary-dependent and preference-dependent decision that jointly considers feasible operation, thermodynamic performance, economic sensitivity, and temperature boundary adaptability.
- Open Access
- 15 June 2026
- Published by Elsevier in SSRN Electronic Journal
Quasi-dynamic techno-economic optimization of Brayton-cycle pumped thermal electricity storage for wind-solar microgrids considering part-load performance degradation
To address renewable curtailment and storage sizing caused by source-load temporal mismatch in high-penetration wind-solar microgrids, this study develops a year-round hourly (8760 h) quasi-dynamic dispatch and techno-economic optimization model for a molten-salt Brayton-cycle pumped thermal electricity storage (PTES) system. The model couples hourly wind and photovoltaic outputs, local load, export-channel constraints, storage-tank state of charge (SOC), and part-load-ratio (PLR) performance degradation to quantify the deviation between design-point evaluation and actual grid-connected operation. Results show that, under the baseline 6 h configuration, the PTES system operates far from the design point: SOC remains above 90% and below 10% for 29.37% and 20.70% of the year, respectively; the compressor operates near full load for only about 20% of its effective operating time; and the maximum expander PLR is about 67%. Compared with static design-point evaluation, quasi-dynamic dispatch reduces annual discharged electricity from 219.00 to 94.20 GWh and dynamic round-trip efficiency (RTE) from 66.92% to 55.81%, while increasing levelized cost of storage (LCOS) from 0.1365 to 0.2753 $/kWh. Power-energy optimization identifies a power scaling factor of 0.3 and a 12 h storage duration as the optimum wind-solar hybrid configuration, reducing LCOS to 0.1772 $/kWh. Different power–energy capacity matching and wind-solar output structure jointly determine the optimal configuration boundary, with the lowest LCOS obtained in the pure photovoltaic scenario. These results demonstrate that PTES capacity planning should shift from static design-point assessment to quasi-dynamic optimization considering temporal dispatch, SOC constraints, and PLR performance mapping.
- 15 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessQuasi-dynamic techno-economic optimization of Brayton-cycle pumped thermal electricity storage for wind-solar microgrids considering part-load performance degradation
To address renewable curtailment and storage sizing caused by source-load temporal mismatch in high-penetration wind-solar microgrids, this study develops a year-round hourly (8760 h) quasi-dynamic dispatch and techno-economic optimization model for a molten-salt Brayton-cycle pumped thermal electricity storage (PTES) system. The model couples hourly wind and photovoltaic outputs, local load, export-channel constraints, storage-tank state of charge (SOC), and part-load-ratio (PLR) performance degradation to quantify the deviation between design-point evaluation and actual grid-connected operation. Results show that, under the baseline 6 h configuration, the PTES system operates far from the design point: SOC remains above 90% and below 10% for 29.37% and 20.70% of the year, respectively; the compressor operates near full load for only about 20% of its effective operating time; and the maximum expander PLR is about 67%. Compared with static design-point evaluation, quasi-dynamic dispatch reduces annual discharged electricity from 219.00 to 94.20 GWh and dynamic round-trip efficiency (RTE) from 66.92% to 55.81%, while increasing levelized cost of storage (LCOS) from 0.1365 to 0.2753 $/kWh. Power-energy optimization identifies a power scaling factor of 0.3 and a 12 h storage duration as the optimum wind-solar hybrid configuration, reducing LCOS to 0.1772 $/kWh. Different power–energy capacity matching and wind-solar output structure jointly determine the optimal configuration boundary, with the lowest LCOS obtained in the pure photovoltaic scenario. These results demonstrate that PTES capacity planning should shift from static design-point assessment to quasi-dynamic optimization considering temporal dispatch, SOC constraints, and PLR performance mapping.