JYJeffrey K. Yang

Jeffrey K. Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jeffrey K. Yang has a total of 103 co-authors. Here are the top co-authors by number of shared publications:

  • Aaron D. Losey

    Department of Radiology and Biomedical Imaging, UCSF, San Francisco, CA, USA

    4 shared publications
  • Mark W. Wilson

    Department of Radiology and Biomedical Imaging, UCSF, San Francisco, CA, USA

    4 shared publications
  • Maythem Saeed

    Department of Radiology and Biomedical Imaging, UCSF, San Francisco, CA, USA

    4 shared publications
  • Jay F. Yu

    Department of Radiology and Biomedical Imaging, UCSF, San Francisco, CA, USA

    3 shared publications
  • Prasheel V. Lillaney

    Department of Radiology and Biomedical Imaging, University of California, San Francisco, 185 Berry St, Suite 350, Room 320, San Francisco, CA, 94107-5705, USA

    3 shared publications
  • Steven W. Hetts

    Department of Radiology and Biomedical Imaging, University of California−San Francisco, San Francisco, California 94107, United States

    3 shared publications

Latest Publications

  • Extended Rhythm Monitoring to Assess for Ventricular Arrhythmias After Transcatheter Pulmonary Valve Replacement With the Harmony Valve

    by Jeffrey K. Yang, Laura Wattenbarger, Anne C. Taylor, Henry Chubb, Anitra W. Romfh, Lynn F. Peng, Scott R. Ceresnak, Anne M. Dubin, Doff B. McElhinney

    BACKGROUND: Varying rates of nonsustained ventricular tachycardia (NSVT) have been reported early after transcatheter pulmonary valve replacement (TPVR) with the Harmony valve, but data regarding rhythm outcomes beyond hospital discharge are limited. This study aims to characterize ventricular arrhythmias after Harmony TPVR from implant through mid-term follow-up. METHODS: Ventricular arrhythmia data from postimplant telemetry and follow-up extended rhythm monitoring (ERM) were analyzed after Harmony TPVR. RESULTS: Fifty-four patients with tetralogy of Fallot (n=39), valvar pulmonary stenosis (n=10), or pulmonary atresia with intact ventricular septum (n=5) were studied; 22% had prior NSVT and 24% were on prior rhythm medication. On postimplant telemetry, 27 patients (50%) had NSVT, including 1 who had torsade de pointes, but most had <5 episodes. Pre-TPVR NSVT or rhythm medications, diagnosis other than tetralogy, and substantial device contact with the myocardium were associated with more frequent NSVT on telemetry. Ten patients (19%) were started on a new antiarrhythmic medication. On discharge ERM, 37% of patients had NSVT, most with <5 episodes and only 13% with NSVT beyond 5 days post-discharge. On follow-up ERM, 14% of patients had a single episode of NSVT and 1 had 5 episodes. During follow-up, antiarrhythmic medications were discontinued in 8 of 10 patients and no patients died or had sustained ventricular tachycardia. CONCLUSIONS: NSVT and ventricular ectopy were common early after TPVR but were infrequent in most cases and diminished rapidly after discharge. The incidence of NSVT on follow-up ERM was similar to preimplant incidence. Few patients had antiarrhythmic medications initiated, and most were discontinued on follow-up. There were no major arrhythmic events after discharge.


  • Mitigating Alarm Fatigue and Improving the Bedside Experience by Reducing Nonactionable Alarms

    by Jeffrey K. Yang, Felice Su, Anna Graber-Naidich, Haley Hedlin, Nicolas Madsen, Carlos DeSousa, Shannon Feehan, Angela Graves, Andrew Palmquist, Rhonda Cable, et al.


  • Intraoperative and Postoperative Hemodynamic Predictors of Acute Kidney Injury in Pediatric Heart Transplant Recipients

    by Seth A. Hollander, Sukyung Chung, Sushma Reddy, Nina Zook, Jeffrey Yang, Tristan Vella, Manchula Navaratnam, Elizabeth Price, Scott M. Sutherland, Claudia A. Algaze

    Acute kidney injury (AKI) is common after pediatric heart transplantation (HT) and is associated with inferior patient outcomes. Hemodynamic risk factors for pediatric heart transplant recipients who experience AKI are not well described. We performed a retrospective review of 99 pediatric heart transplant patients at Lucile Packard Children's Hospital Stanford from January 1, 2015, to December 31, 2019, in which clinical and demographic characteristics, intraoperative perfusion data, and hemodynamic measurements in the first 48 postoperative hours were analyzed as risk factors for severe AKI (Kidney Disease: Improving Global Outcomes [KDIGO] stage ≥ 2). Univariate analysis was conducted using Fisher's exact test, Chi-square test, and the Wilcoxon rank-sum test, as appropriate. Multivariable analysis was conducted using logistic regression. Thirty-five patients (35%) experienced severe AKI which was associated with lower intraoperative cardiac index (p = 0.001), higher hematocrit (p < 0.001), lower body temperature (p < 0.001), lower renal near-infrared spectroscopy (p = 0.001), lower postoperative mean arterial blood pressure (MAP: p = 0.001), and higher central venous pressure (CVP; p < 0.001). In multivariable analysis, postoperative CVP >12 mm Hg (odds ratio [OR] = 4.27; 95% confidence interval [CI]: 1.48–12.3, p = 0.007) and MAP <65 mm Hg (OR = 4.9; 95% CI: 1.07–22.5, p = 0.04) were associated with early severe AKI. Children with severe AKI experienced longer ventilator, intensive care, and posttransplant hospital days and inferior survival (p = 0.01). Lower MAP and higher CVP are associated with severe AKI in pediatric HT recipients. Patients, who experienced AKI, experienced increased intensive care unit (ICU) morbidity and inferior survival. These data may guide the development of perioperative renal protective management strategies to reduce AKI incidence and improve patient outcomes.


  • Open Access

    Non-Contact Video-Based Neonatal Respiratory Monitoring

    by Scott L. Rossol, Jeffrey K. Yang, Caroline Toney-Noland, Janine Bergin, Chandan Basavaraju, Pavan Kumar, Henry C. Lee

    Respiratory rate (RR) has been shown to be a reliable predictor of cardio-pulmonary deterioration, but standard RR monitoring methods in the neonatal intensive care units (NICU) with contact leads have been related to iatrogenic complications. Video-based monitoring is a potential non-contact system that could improve patient care. This iterative design study developed a novel algorithm that produced RR from footage analyzed from stable NICU patients in open cribs with corrected gestational ages ranging from 33 to 40 weeks. The final algorithm used a proprietary technique of micromotion and stationarity detection (MSD) to model background noise to be able to amplify and record respiratory motions. We found significant correlation—r equals 0.948 (p value of 0.001)—between MSD and the current hospital standard, electrocardiogram impedance pneumography. Our video-based system showed a bias of negative 1.3 breaths and root mean square error of 6.36 breaths per minute compared to standard continuous monitoring. Further work is needed to evaluate the ability of video-based monitors to observe clinical changes in a larger population of patients over extended periods of time.


  • Pectoral nerve blocks decrease postoperative pain and opioid use after pacemaker or implantable cardioverter–defibrillator placement in children

    by Jeffrey K. Yang, Danton S. Char, Kara S. Motonaga, Manchula Navaratnam, Anne M. Dubin, Anthony Trela, Debra G. Hanisch, Grant McFadyen, Henry Chubb, William R. Goodyer, et al.


  • Interventional magnetic resonance imaging guided carotid embolectomy using a novel resonant marker catheter: demonstration of preclinical feasibility

    by Jeffrey K. Yang, Andre M. Cote, Caroline D. Jordan, Sravani Kondapavulur, Aaron D. Losey, David McCoy, Andrew Chu, Jay F. Yu, Teri Moore, Carol Stillson, et al.

    To assess the visualization and efficacy of a wireless resonant circuit (wRC) catheter system for carotid artery occlusion and embolectomy under real-time MRI guidance in vivo, and to compare MR imaging modality with x-ray for analysis of qualitative physiological measures of blood flow at baseline and after embolectomy. The wRC catheter system was constructed using a MR compatible PEEK fiber braided catheter (Penumbra, Inc, Alameda, CA) with a single insulated longitudinal copper loop soldered to a printed circuit board embedded within the catheter wall. In concordance with IACUC protocol (AN103047), in vivo carotid artery navigation and embolectomy were performed in four farm pigs (40–45 kg) under real-time MRI at 1.5T. Industry standard clots were introduced in incremental amounts until adequate arterial occlusion was noted in a total of n=13 arteries. Baseline vasculature and restoration of blood flow were confirmed via MR and x-ray imaging, and graded by the Thrombolysis in Cerebral Infarction (TICI) scale. Wilcoxon signed-rank tests were used to analyze differences in recanalization status between DSA and MRA imaging. Successful recanalizations (TICI 2b/3) were compared to clinical rates reported in literature via binomial tests. The wRC catheter system was visible both on 5° sagittal bSSFP and coronal GRE sequence. Successful recanalization was demonstrated in 11 of 13 occluded arteries by DSA analysis and 8 of 13 by MRA. Recanalization rates based on DSA (0.85) and MRA (0.62) were not significantly different from the clinical rate of mechanical aspiration thrombectomy reported in literature. Lastly, a Wilcoxon signed rank test indicated no significant difference between TICI scores analyzed by DSA and MRA. With demonstrated compatibility and visualization under MRI, the wRC catheter system is effective for in vivo endovascular embolectomy, suggesting progress towards clinical endovascular interventional MRI.


  • Global Spinal Alignment in Cervical Kyphotic Deformity: The Importance of Head Position and Thoracolumbar Alignment in the Compensatory Mechanism

    by Jun Mizutani, Kushagra Verma, Kenji Endo, Ken Ishii, Kuniyoshi Abumi, Mitsuru Yagi, Naobumi Hosogane, Jeffrey Yang, Bobby Tay, Vedat Deviren, et al.

    BACKGROUND: Previous studies have evaluated cervical kyphosis (C-kypho) using cervical curvature or chin-brow vertical angle, but the relationship between C-kypho and global spinal alignment is currently unknown. OBJECTIVE: To elucidate global spinal alignment and compensatory mechanisms in primary symptomatic C-kypho using full-spine radiography. METHODS: In this retrospective multicenter study, symptomatic primary C-kypho patients (Cerv group; n = 103) and adult thoracolumbar deformity patients (TL group; n = 119) were compared. We subanalyzed Cerv subgroups according to sagittal vertical axis (SVA) values of C7 (SVAC7 positive or negative [C7P or C7N]). Various Cobb angles (°) and SVAs (mm) were evaluated. RESULTS: SVAC7 values were –20.2 and 63.6 mm in the Cerv group and TL group, respectively (P < .0001). Various statistically significant compensatory curvatures were observed in the Cerv group, namely larger lumbar lordosis (LL) and thoracic kyphosis. The C7N group had significantly lower SVACOG (center of gravity of the head) and SVAC7 (32.9 and –49.5 mm) values than the C7P group (115.9 and 45.1 mm). Sagittal curvatures were also different in T4-12, T10-L2, LL4-S, and LL. The value of pelvic incidence (PI)-LL was different (C7N vs C7P; –2.2° vs 9.9°; P < .0003). Compensatory sagittal curvatures were associated with potential for shifting of SVAC7 posteriorly to adjust head position. PI-LL affected these compensatory mechanisms. CONCLUSION: Compensation in symptomatic primary C-kypho was via posterior shifting of SVAC7, small T1 slope, and large LL. However, even in C-kypho patients, lumbar degeneration might affect global spinal alignment. Thus, global spinal alignment with cervical kyphosis is characterized as head balanced or trunk balanced.


  • In vitro clearance of doxorubicin with a DNA-based filtration device designed for intravascular use with intra-arterial chemotherapy

    by Mariam S. Aboian, Jay F. Yu, Ayushi Gautam, Chia-Hung Sze, Jeffrey K. Yang, Jonathan Chan, Prasheel V. Lillaney, Caroline D. Jordan, Hee-Jeung Oh, David M. Wilson, et al.

    To report a novel method using immobilized DNA within mesh to sequester drugs that have intrinsic DNA binding characteristics directly from flowing blood. DNA binding experiments were carried out in vitro with doxorubicin in saline (PBS solution), porcine serum, and porcine blood. Genomic DNA was used to identify the concentration of DNA that shows optimum binding clearance of doxorubicin from solution. Doxorubicin binding kinetics by DNA enclosed within porous mesh bags was evaluated. Flow model simulating blood flow in the inferior vena cava was used to determine in vitro binding kinetics between doxorubicin and DNA. The kinetics of doxorubicin binding to free DNA is dose-dependent and rapid, with 82–96 % decrease in drug concentration from physiologic solutions within 1 min of reaction time. DNA demonstrates faster binding kinetics by doxorubicin as compared to polystyrene resins that use an ion exchange mechanism. DNA contained within mesh yields an approximately 70 % decrease in doxorubicin concentration from solution within 5 min. In the IVC flow model, there is a 70 % drop in doxorubicin concentration at 60 min. A DNA-containing ChemoFilter device can rapidly clear clinical doses of doxorubicin from a flow model in simple and complex physiological solutions, thereby suggesting a novel approach to reduce the toxicity of DNA-binding drugs.


  • Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System

    by Prasheel V. Lillaney, Jeffrey K. Yang, Aaron D. Losey, Alastair J. Martin, Daniel L. Cooke, Bradford R. H. Thorne, David C. Barry, Andrew Chu, Carol Stillson, Loi Do, et al.

    Our study demonstrates the feasibility of using the magnetically assisted remote-controlled catheter in MR-guided endovascular embolization and opens up a novel opportunity to perform endovascular ... PurposeTo assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (i...


  • Open Access

    Block Copolymer Membranes for Efficient Capture of a Chemotherapy Drug

    by X. Chelsea Chen, Hee Jeung Oh, Jay F. Yu, Jeffrey K. Yang, Nikos Petzetakis, Anand S. Patel, Steven W. Hetts, Nitash P. Balsara

    We introduce the use of block copolymer membranes for an emerging application, “drug capture”. The polymer is incorporated in a new class of biomedical devices, referred to as ChemoFilter, which is an image-guided temporarily deployable endovascular device designed to increase the efficacy of chemotherapy-based cancer treatment. We show that block copolymer membranes consisting of functional sulfonated polystyrene end blocks and a structural polyethylene middle block (S-SES) are capable of capturing doxorubicin, a chemotherapy drug. We focus on the relationship between morphology of the membrane in the ChemoFilter device and efficacy of doxorubicin capture measured in vitro. Using small-angle X-ray scattering and cryogenic scanning transmission electron microscopy, we discovered that rapid doxorubicin capture is associated with the presence of water-rich channels in the lamellar-forming S-SES membranes in aqueous environment.