Wansong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wansong Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Boyu Qin
School of Energy and Electrical Engineering, Qinghai University, Xining 810016, China
6 shared publications - Hengyi Li
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
4 shared publications Albert Y. Zomaya
Centre for Distributed and High Performance Computing The University of Sydney Sydney Australia
1 shared publicationJialing Liu
1 shared publication- Jialing Liu
State Key Laboratory of Electrical Insulation and Power Equipment, and the School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Jialing Liu
The School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, China
1 shared publication
Latest Publications
- 4 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (5) , 3913-3922
Impact of System Inherent Characteristics on Initial-Stage Short-Circuit Current of MMC-Based MTDC Transmission Systems
This paper studies the impact of the inherent characteristics on the initial-stage short-circuit current of modular multilevel converter based multi-terminal direct current (MMC-based MTDC) transmission system. A short-circuit current calculation method based on input-output characteristics is proposed. The MMC’s input-output characteristics are factorized into a series combination of a linear and a nonlinear part through the operator approach. The inherent characteristics of the system represent the inherent properties of the MMC-based MTDC system, which are unrelated to the short-circuit fault. Therefore, short-circuit currents are decoupled and quantitative indices are proposed to measure the impact of the system inherent characteristics on the initial-stage short-circuit current. The proposed decoupled short-circuit current calculation method and the quantitative indices are verified in a typical MMC-based MTDC transmission system under different system parameters and structures. The proposed quantitative indices can effectively evaluate the short-circuit current of the MMC-based MTDC system without calculating the short-circuit current, which indicates that they can provide guidance for the planning of DC system structure, determination of operational modes, and selection of system parameters from the perspective of short-circuit current.
- 4 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (5) , 3913-3922
Impact of System Inherent Characteristics on Initial-Stage Short-Circuit Current of MMC-Based MTDC Transmission Systems
This paper studies the impact of the inherent characteristics on the initial-stage short-circuit current of modular multilevel converter based multi-terminal direct current (MMC-based MTDC) transmission system. A short-circuit current calculation method based on input-output characteristics is proposed. The MMC’s input-output characteristics are factorized into a series combination of a linear and a nonlinear part through the operator approach. The inherent characteristics of the system represent the inherent properties of the MMC-based MTDC system, which are unrelated to the short-circuit fault. Therefore, short-circuit currents are decoupled and quantitative indices are proposed to measure the impact of the system inherent characteristics on the initial-stage short-circuit current. The proposed decoupled short-circuit current calculation method and the quantitative indices are verified in a typical MMC-based MTDC transmission system under different system parameters and structures. The proposed quantitative indices can effectively evaluate the short-circuit current of the MMC-based MTDC system without calculating the short-circuit current, which indicates that they can provide guidance for the planning of DC system structure, determination of operational modes, and selection of system parameters from the perspective of short-circuit current.
- 17 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 576-581
Control Parameters Optimization Method of Energy Router-Based AC/DC Hybrid Distribution Systems
This paper proposes a control parameters optimization method for the energy router-based AC/DC hybrid distribution systems. First, the small signal model of the energy router-based AC/DC hybrid distribution systems consisting of high voltage AC/DC parts, medium voltage part and low voltage AC/DC parts is derived. Second, the influence of system control parameters on the system stability is analyzed. Third, an eigenvalue-based optimization problem is formulated, and a control parameters optimization method based on sensitivity analysis is proposed to optimize the control parameters jointly. Finally, stability assessment and time-domain simulations are performed to verify the effectiveness of the proposed method.
- 17 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 576-581
Control Parameters Optimization Method of Energy Router-Based AC/DC Hybrid Distribution Systems
This paper proposes a control parameters optimization method for the energy router-based AC/DC hybrid distribution systems. First, the small signal model of the energy router-based AC/DC hybrid distribution systems consisting of high voltage AC/DC parts, medium voltage part and low voltage AC/DC parts is derived. Second, the influence of system control parameters on the system stability is analyzed. Third, an eigenvalue-based optimization problem is formulated, and a control parameters optimization method based on sensitivity analysis is proposed to optimize the control parameters jointly. Finally, stability assessment and time-domain simulations are performed to verify the effectiveness of the proposed method.
- Open Access
- 10 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (10) , 1871-1878
Interaction between damping characteristics and the initial‐stage short‐circuit current of MMC‐HVDC transmission systems
This paper studies the interaction between the damping characteristics and the initial‐stage short‐circuit current of modular multilevel converter based high voltage direct current (MMC‐HVDC) transmission system. First, the MMCs' input–output characteristics are obtained through the operator approach, and the influences of both linear part and nonlinear part are analysed. Second, an input–output characteristics based short‐circuit current calculation method is proposed. Third, an eigenvalue‐based comprehensive index is proposed to evaluate the damping characteristics of the MMC‐HVDC transmission system. Finally, the interaction between the damping characteristics and the initial‐stage DC short‐circuit current is analysed under different system parameters and DC system structures. The analysis results show that there is a negative correlation between the system damping characteristics and the average rising rate of the short‐circuit current. The proposed index G can effectively evaluate the short‐circuit current of MMC‐HVDC and can provide guidance for the planning of DC system structure, the selection of operation mode and system parameters.
- 10 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (10) , 1871-1878
Open AccessInteraction between damping characteristics and the initial‐stage short‐circuit current of MMC‐HVDC transmission systems
This paper studies the interaction between the damping characteristics and the initial‐stage short‐circuit current of modular multilevel converter based high voltage direct current (MMC‐HVDC) transmission system. First, the MMCs' input–output characteristics are obtained through the operator approach, and the influences of both linear part and nonlinear part are analysed. Second, an input–output characteristics based short‐circuit current calculation method is proposed. Third, an eigenvalue‐based comprehensive index is proposed to evaluate the damping characteristics of the MMC‐HVDC transmission system. Finally, the interaction between the damping characteristics and the initial‐stage DC short‐circuit current is analysed under different system parameters and DC system structures. The analysis results show that there is a negative correlation between the system damping characteristics and the average rising rate of the short‐circuit current. The proposed index G can effectively evaluate the short‐circuit current of MMC‐HVDC and can provide guidance for the planning of DC system structure, the selection of operation mode and system parameters.
- Open Access
- 1 December 2020
- Published by Elsevier in Energy Reports
- Vol. 6, 1130-1135
Impact of control system on small-signal stability of MMC-based MTDC transmission system
- 1 December 2020
- Published by Elsevier in Energy Reports
- Vol. 6, 1130-1135
Open AccessImpact of control system on small-signal stability of MMC-based MTDC transmission system
- Open Access
- 27 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (19) , 6769
Review on Short-circuit Current Analysis and Suppression Techniques for MMC-HVDC Transmission Systems
The modular multilevel converter (MMC) has been widely adopted in high voltage direct current (HVDC) transmission systems due to its significant advantages. MMC-HVDC is developing towards multi-terminal direct current (MTDC) power grid for reliability enhancement. However, there exist a huge amplitude and a steep rise in fault current due to the low impedances of DC lines and MMCs, which threaten the security and reliability of the DC power grids. It is necessary to restrain the DC short circuit current in order to ensure the safe and stable operation of DC power grids. This paper gives a comprehensive review and evaluation of the proposed DC short-circuit current analysis and suppression techniques used in MMC-based MTDC power girds, in terms of MMC modeling, short circuit calculation, and suppression method. In addition, future trends of countermeasures to short circuit current in MMC-based MTDC power grids are also discussed.
- 27 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (19) , 6769
Open AccessReview on Short-circuit Current Analysis and Suppression Techniques for MMC-HVDC Transmission Systems
The modular multilevel converter (MMC) has been widely adopted in high voltage direct current (HVDC) transmission systems due to its significant advantages. MMC-HVDC is developing towards multi-terminal direct current (MTDC) power grid for reliability enhancement. However, there exist a huge amplitude and a steep rise in fault current due to the low impedances of DC lines and MMCs, which threaten the security and reliability of the DC power grids. It is necessary to restrain the DC short circuit current in order to ensure the safe and stable operation of DC power grids. This paper gives a comprehensive review and evaluation of the proposed DC short-circuit current analysis and suppression techniques used in MMC-based MTDC power girds, in terms of MMC modeling, short circuit calculation, and suppression method. In addition, future trends of countermeasures to short circuit current in MMC-based MTDC power grids are also discussed.
- Open Access
- 22 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (6) , 2154
Low-Voltage Ride-Through Techniques in DFIG-Based Wind Turbines: A Review
In recent years, considerable advances were made in wind power generation. The growing penetration of wind power makes it necessary for wind turbines to maintain continuous operation during voltage dips, which is stated as the low-voltage ride-through (LVRT) capability. Doubly fed induction generator (DFIG)-based wind turbines (DFIG-WTs), which are widely used in wind power generation, are sensitive to disturbances from the power grid. Therefore, several kinds of protection circuits and control methods are applied to DFIG-WTs for LVRT capability enhancement. This paper gives a comprehensive review and evaluation of the proposed LVRT solutions used in DFIG-WTs, including external retrofit methods and internal control techniques. In addition, future trends of LVRT solutions are also discussed in this paper.
- 22 March 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (6) , 2154
Open AccessLow-Voltage Ride-Through Techniques in DFIG-Based Wind Turbines: A Review
In recent years, considerable advances were made in wind power generation. The growing penetration of wind power makes it necessary for wind turbines to maintain continuous operation during voltage dips, which is stated as the low-voltage ride-through (LVRT) capability. Doubly fed induction generator (DFIG)-based wind turbines (DFIG-WTs), which are widely used in wind power generation, are sensitive to disturbances from the power grid. Therefore, several kinds of protection circuits and control methods are applied to DFIG-WTs for LVRT capability enhancement. This paper gives a comprehensive review and evaluation of the proposed LVRT solutions used in DFIG-WTs, including external retrofit methods and internal control techniques. In addition, future trends of LVRT solutions are also discussed in this paper.