HLHongyuan Liu

Hongyuan Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hongyuan Liu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Jing Yang

    Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China

    2 shared publications
  • Ruihong Sun

    Department of Radiology, Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430014, China

    2 shared publications
  • Yu Chang

    Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China

    2 shared publications
  • Gang Liu

    Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China

    1 shared publication
  • Gang Wu

    Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication
  • Hao Peng

    Department of Medical Physics, Wuhan University, Wuhan, China

    1 shared publication

Latest Publications

  • Open Access

    Preoperative Prediction of Fat-Suppressed T2-Weighted Imaging-based Breast Edema Scores for Lymphovascular Invasion in Patients with Breast Cancer

    by Ruihong Sun, Xi Wang, Yun Hu, Zengfa Huang, Hongyuan Liu, Xiang Wang

    Introduction: Lymphovascular invasion (LVI) is a critical prognostic factor in breast cancer, typically diagnosed via postoperative pathology. This study aimed to evaluate whether fat-suppressed T2-weighted imaging (FS T2WI)-based breast edema score (BES) combined with clinicopathological features could preoperatively predict LVI status. Materials and Methods: This retrospective study enrolled 574 breast cancer patients who underwent MRI and surgery from January 2021 to December 2023. Patients were classified as LVI-positive (n=174) or LVI-negative (n=400) based on postoperative pathology. Breast edema on FS T2WI was scored from 1 to 4 (BES 1, no edema; BES 2, peritumoral edema; BES 3, prepectoral edema; and BES 4, subcutaneous edema). Univariate and multivariate binary logistic regression analyses were performed to identify risk factors associated with LVI. A clinicopathological model and a combined BES–clinicopathological model were constructed, and diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC) and the DeLong test. Results: Multivariate analysis revealed that BES and clinicopathological factors, including age, axillary lymph node metastasis, and tumor size, were independent predictors of LVI. Compared with BES 1, tumors with BES 2, BES 3, and BES 4 were associated with a 1.825-, 2.047-, and 4.341- fold increased LVI risk, respectively. The combined BES–clinicopathological model outperformed the clinicopathological model alone (AUC, 0.765 vs. 0.778; P< 0.05). Discussion: Higher BES was independently associated with increased LVI risk. The predictive model integrating BES with clinicopathological variables outperformed single-parameter models, suggesting that BES may provide complementary imaging biomarkers for assessing tumor aggressiveness. Validation in larger, multicenter cohorts is warranted. Conclusion: FS T2WI-based BES combined with clinicopathological features may improve preoperative prediction of LVI in breast cancer and support individualized treatment planning.

  • Top Cited Papers
    Open Access

    Mediastinal Emphysema, Giant Bulla, and Pneumothorax Developed during the Course of COVID-19 Pneumonia

    by Ruihong Sun, Hongyuan Liu, Xiang Wang

    Sun R, et al. Korean J Radiol. 2020 Feb;21:e43. https://doi.org/10.3348/kjr.2020.0180


  • Real-time tumor motion monitoring and PTV margin determination in lung SBRT treatment

    by Zhiwen Liang, Jing Yang, Hongyuan Liu, Zhongyuan Yin, Sheng Zhang, Hao Peng, Gang Wu

    Stereotactic body radiation therapy (SBRT) is an effective treatment procedure allowing the delivery of high radiation doses in a small number of fractions to produce a high biological effective do...


  • Open Access

    Dosimetric Effect of Intrafraction Tumor Motion in Lung Stereotactic Body Radiotherapy Using CyberKnife Static Tracking System

    by Yu Chang, Hong-Yuan Liu, Zhi-Wen Liang, Xin Nie, Jing Yang, Gang Liu, Qin Li, Zhi-Yong Yang

    Purpose: We investigated the dosimetric effect of intrafraction tumor motion in lung stereotactic body radiotherapy using the CyberKnife static tracking system. Methods: Four-dimensional computed tomography scans of a dynamic thorax phantom were acquired. Two motion ranges, 3 collimator sizes, and 4 treatment starting phases were investigated. Monte Carlo dose distributions were calculated on internal target volume with a treatment-specific setup margin for 6 Gy/1 fraction. Dosimetric effects of intrafractional tumor motion were assessed with Gafchromic films. γ (5%/3 mm), dose differences, and distance to agreement were analyzed. Results: With 30 mm collimator plans, the measured dose passed the criteria γ (5%/3 mm) in all tumor motion ranges. The γ passing rates of the plans using 20 mm or 20+35 mm collimators were much lower than that with 30 mm collimator, especially with the 30 mm tumor motion range. The measured dose of 10 mm tumor motion ranges all passed the 90% criteria of γ (5%/3 mm), the results being much better than those of 30 mm tumor motion ranges, which were below 80%. The results of same delivered plan but treated with different starting phases varies greatly. Conclusion: Xsight Lung Tracking technique should be used with caution in lung cancer stereotactic body radiation therapy because the temporal dose variations can be significant.


  • Open Access

    Target margin design for real-time lung tumor tracking stereotactic body radiation therapy using CyberKnife Xsight Lung Tracking System

    by Zhi-Yong Yang, Yu Chang, Hong-Yuan Liu, Gang Liu, Qin Li

    The objective of this study is to quantify the clinical accuracy of the Cyberknife Xsight Lung Tracking System (XLTS) in our center and calculate the PTV margin of XLTS treated lung tumors. Data from the treatment log files of 22 lung cancer patients treated with the CyberKnife XLTS were analyzed and the PTV margin was calculated. Segmentation, deformation, correlation, prediction and targeting errors were calculated from the log files of XLTS treatments. Two different methods were used to calculate anisotropic treatment margin. The relationships between tumor motion ranges and the correlation and prediction errors were also analyzed. Based on our estimation of a 4 mm global margin, 95% coverage in the S-I direction and 100% coverage in the L-R and A-P directions were obtained. Strong correlations between tumor motion range and the standard deviation (SD) of correlation and prediction errors were also found. Tumor position motion caused by respiration can be compensated using the Xsight Lung Tracking System. We found total tracking errors to be less than 4 mm in all three directions. This result could provide a reference for the selection of PTV margin for treatment with the CyberKnife XLTS.