Hamidreza Masjedi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hamidreza Masjedi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mohammad Hosein Zare
Shahid Sadoughi University of Medical Sciences, Medical Physics Department, Yazd, Iran
3 shared publications - Akuroma Tolvanen
University of Eastern Finland, Faculty of Science, Forestry and Technology, Department of Technical Physics, Kuopio, Finland
1 shared publication Arash Mirhashemi
Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
1 shared publication- Eloi Canals Pascual
Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
1 shared publication - Ervin Nippolainen
Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
1 shared publication Fatemeh Alavi
Department of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
1 shared publication
Latest Publications
- Open Access
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP (02780062) , 1
Prediction of Articular Cartilage Markers with Multispectral Imaging
Osteoarthritis (OA) is a debilitating joint disease in which early microstructural and compositional changes in articular cartilage (AC) are challenging to detect with current diagnostic tools. We hypothesized that multispectral imaging (MSI) could capture optical signatures that predict key AC properties. To test this, we developed and evaluated an MSI-based approach for estimating tissue thickness, proteoglycan (PG) content, collagen fiber orientation, and cell morphological properties (area and circularity). Reflectance images of bovine patellar AC were acquired using a custom-built MSI system operating at six wavelengths (550–970 nm), and machine learning models were trained to predict the targeted markers. The models yielded reliable estimates for AC thickness, whereas for PG content, collagen fiber orientation, and cell circularity, they achieved moderate accuracy. This work suggests that MSI holds promise as a label-free tool for characterizing AC and detecting early degenerative changes.
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP (02780062) , 1
Open AccessPrediction of Articular Cartilage Markers with Multispectral Imaging
Osteoarthritis (OA) is a debilitating joint disease in which early microstructural and compositional changes in articular cartilage (AC) are challenging to detect with current diagnostic tools. We hypothesized that multispectral imaging (MSI) could capture optical signatures that predict key AC properties. To test this, we developed and evaluated an MSI-based approach for estimating tissue thickness, proteoglycan (PG) content, collagen fiber orientation, and cell morphological properties (area and circularity). Reflectance images of bovine patellar AC were acquired using a custom-built MSI system operating at six wavelengths (550–970 nm), and machine learning models were trained to predict the targeted markers. The models yielded reliable estimates for AC thickness, whereas for PG content, collagen fiber orientation, and cell circularity, they achieved moderate accuracy. This work suggests that MSI holds promise as a label-free tool for characterizing AC and detecting early degenerative changes.
- 4 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (4) , 2350-2351
In response to “Measurement of neutron yield for a medical linear accelerator below 10 MV”
- 4 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (4) , 2350-2351
In response to “Measurement of neutron yield for a medical linear accelerator below 10 MV”
- 1 May 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 126, 108932
Radiation dose and risk of exposure-induced death associated with common computed tomography procedures in Yazd Province
- 1 May 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 126, 108932
Radiation dose and risk of exposure-induced death associated with common computed tomography procedures in Yazd Province
- Open Access
Nowcasting and Forecasting the Spread of COVID-19 in Iran
Introduction: As of early December 2019, COVID-19, a disease induced by SARS-COV-2, has started spreading, originated in Wuhan, China, and now on, have infected more than 2 million individuals throughout the world. Purpose: This study aimed to nowcast the COVID-19 outbreak throughout Iran and to forecast the trends of the disease spreading in the upcoming month. Methods: The cumulative incidence and fatality data were extracted from official reports of the National Ministry of Health and Medical Educations of Iran. To formulate the outbreak dynamics, six phenomenological models, as well as a modified mechanistic Susciptible-Exposed-Infectious-Recovered (SEIR) model, were implemented. The models were calibrated with the integrated data, and trends of the epidemic in Iran was then forecasted for the next month. Results: The final outbreak size calculated by the best fitted phenomenological models was estimated to be in the range of 68,486 to 118,923 cases; however, the calibrated SEIR model estimated that the outbreak would rage again, starting from April 26. Moreover, projected by the mechanistic model, approximately half of the infections have undergone undetected. Conclusion: Although the advanced phenomenological models perfectly fitted the data, they are incapable of applying behavioral aspects of the outbreak and hence, are not reliable enough for authorities’ decision adoptions. In contrast, the mechanistic SEIR model alarms that the COVID-19 outbreak in Iran may peak for the second time, consequent to lifting the control measures. This implies that the government may implement a more granular decision making to control the outbreak.
Open AccessNowcasting and Forecasting the Spread of COVID-19 in Iran
Introduction: As of early December 2019, COVID-19, a disease induced by SARS-COV-2, has started spreading, originated in Wuhan, China, and now on, have infected more than 2 million individuals throughout the world. Purpose: This study aimed to nowcast the COVID-19 outbreak throughout Iran and to forecast the trends of the disease spreading in the upcoming month. Methods: The cumulative incidence and fatality data were extracted from official reports of the National Ministry of Health and Medical Educations of Iran. To formulate the outbreak dynamics, six phenomenological models, as well as a modified mechanistic Susciptible-Exposed-Infectious-Recovered (SEIR) model, were implemented. The models were calibrated with the integrated data, and trends of the epidemic in Iran was then forecasted for the next month. Results: The final outbreak size calculated by the best fitted phenomenological models was estimated to be in the range of 68,486 to 118,923 cases; however, the calibrated SEIR model estimated that the outbreak would rage again, starting from April 26. Moreover, projected by the mechanistic model, approximately half of the infections have undergone undetected. Conclusion: Although the advanced phenomenological models perfectly fitted the data, they are incapable of applying behavioral aspects of the outbreak and hence, are not reliable enough for authorities’ decision adoptions. In contrast, the mechanistic SEIR model alarms that the COVID-19 outbreak in Iran may peak for the second time, consequent to lifting the control measures. This implies that the government may implement a more granular decision making to control the outbreak.
- 16 December 2019
- Published by Springer Nature in La radiologia medica
- Vol. 125 (3) , 296-305
European trends in radiology: investigating factors affecting the number of examinations and the effective dose
The advances in technology have led to a growing trend in population exposure to radiation emerging from the invention of high-dose procedures. It is, for example, estimated that annually 1.2% of cancers are induced by radiological scans in Norway. This study aims to investigate and discuss the frequency and dose trends of radiological examinations in Europe. European Commission (EC) launched projects to gain information for medical exposures in 2004 and 2011. In this study, the European Commission Radiation Protection (RP) reports No. 154 and 180 have been reviewed. The RP 154 countries’ data were extracted from both reports, and the average variation trend of the number of examinations and effective doses were studied. According to the results, plain radiography and fluoroscopy witnessed a reduction in the frequency and effective dose per examination. Nevertheless, European collective dose encountered an average increase of 23%, which resulted from a growing tendency for implementation of high-dose procedures such as CT scans and interventional examinations. It is worth noting that most of the CT procedures have undergone an increase in effective dose per examination. Although demand and dose per examination in some radiological procedures (such as intravenous urography (IVU) have been reduced, population collective dose is still rising due to the increasing demand for CT scan procedures. Even though the individual risks are not considerable, it can, in a large scale, threaten the health of the people at the present time. Due to this fact, better justification should be addressed so as to reduce population exposure.
- 16 December 2019
- Published by Springer Nature in La radiologia medica
- Vol. 125 (3) , 296-305
European trends in radiology: investigating factors affecting the number of examinations and the effective dose
The advances in technology have led to a growing trend in population exposure to radiation emerging from the invention of high-dose procedures. It is, for example, estimated that annually 1.2% of cancers are induced by radiological scans in Norway. This study aims to investigate and discuss the frequency and dose trends of radiological examinations in Europe. European Commission (EC) launched projects to gain information for medical exposures in 2004 and 2011. In this study, the European Commission Radiation Protection (RP) reports No. 154 and 180 have been reviewed. The RP 154 countries’ data were extracted from both reports, and the average variation trend of the number of examinations and effective doses were studied. According to the results, plain radiography and fluoroscopy witnessed a reduction in the frequency and effective dose per examination. Nevertheless, European collective dose encountered an average increase of 23%, which resulted from a growing tendency for implementation of high-dose procedures such as CT scans and interventional examinations. It is worth noting that most of the CT procedures have undergone an increase in effective dose per examination. Although demand and dose per examination in some radiological procedures (such as intravenous urography (IVU) have been reduced, population collective dose is still rising due to the increasing demand for CT scan procedures. Even though the individual risks are not considerable, it can, in a large scale, threaten the health of the people at the present time. Due to this fact, better justification should be addressed so as to reduce population exposure.
- 12 December 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 188 (2) , 222-231
ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE
Objective: The aim of this study was to propose first established diagnostic reference levels (DRLs) in computed tomography (CT) for adults, based on volume-averaged CTDI and dose length product (DLP) metrics in Yazd Province. Materials and Methods: Six multislice CT scanners located at diverse areas of Yazd Province and seven common procedures were selected for the present study. For each procedure, at least twenty patients 18 years and older were sampled at each institution. For each patient, dose report data and scan parameters as well as patient's information were abstracted from picture archiving and communication system. Results: Proposed DRLs in terms of computed tomography dose index (mGy) and DLP (mGy.cm) were as follows: brain (42, 527), sinus (25, 220), neck (14, 264), abdomen-pelvis (11, 295), routine chest (8, 247), CT pulmonary angiogram (32, 261) and chest HRCT (11, 455), respectively, slightly lower compared to other investigations. Conclusion: The proposed DRLs in this study should be considered as the local DRLs for the seven most common adult CT examinations in Yazd province so as to optimize the patient dose while maintaining acceptable image quality for the clinical task.
- 12 December 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 188 (2) , 222-231
ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE
Objective: The aim of this study was to propose first established diagnostic reference levels (DRLs) in computed tomography (CT) for adults, based on volume-averaged CTDI and dose length product (DLP) metrics in Yazd Province. Materials and Methods: Six multislice CT scanners located at diverse areas of Yazd Province and seven common procedures were selected for the present study. For each procedure, at least twenty patients 18 years and older were sampled at each institution. For each patient, dose report data and scan parameters as well as patient's information were abstracted from picture archiving and communication system. Results: Proposed DRLs in terms of computed tomography dose index (mGy) and DLP (mGy.cm) were as follows: brain (42, 527), sinus (25, 220), neck (14, 264), abdomen-pelvis (11, 295), routine chest (8, 247), CT pulmonary angiogram (32, 261) and chest HRCT (11, 455), respectively, slightly lower compared to other investigations. Conclusion: The proposed DRLs in this study should be considered as the local DRLs for the seven most common adult CT examinations in Yazd province so as to optimize the patient dose while maintaining acceptable image quality for the clinical task.