Kun Tu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kun Tu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jin Wu
College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
2 shared publications - Huachao Deng
Department of Civil and Airport Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao Street, Nanjing 210016, China
1 shared publication - Lifang Zhang
College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
1 shared publication - Rui Zhang
School of Kangda, Nanjing Medical University, 88 Chunhui Road, Lianyungang 222000, China
1 shared publication - Xing Zhao
College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China
1 shared publication - Yiyuan Wang
College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, No. 29, Yudao St., Nanjing 211106, China
1 shared publication
Latest Publications
- Open Access
Repair Strategy for Epoxy Anticorrosive Coatings on Steel Structures
This paper presents the results of a test of epoxy anticorrosion coating repair. Two strategies of coating repair were studied, respectively: partial repair and integral repair. The gloss loss rate, color difference and rust area rate of the repair coating were measured. The anticorrosion performance of repair coatings under different repair methods was compared. Based on the results of the coating repair test, the repair criteria for coatings were defined, and the repair strategy for epoxy anticorrosive coatings on steel structure was proposed. The results show that Marathon 500 super abrasion resistant epoxy paint (M500) and Jotamastic 90 GF low surface treatment epoxy abrasion resistant glass flake paint (J90GF) are suitable for partial repair of epoxy anticorrosive coatings on steel structures, and that Jotamastic 90 low surface treatment epoxy abrasion resistant coating (J90) and Marathon 500 super abrasion resistant epoxy paint (M500) are suitable for integral repair of epoxy anticorrosive coatings on steel structures.
Open AccessRepair Strategy for Epoxy Anticorrosive Coatings on Steel Structures
This paper presents the results of a test of epoxy anticorrosion coating repair. Two strategies of coating repair were studied, respectively: partial repair and integral repair. The gloss loss rate, color difference and rust area rate of the repair coating were measured. The anticorrosion performance of repair coatings under different repair methods was compared. Based on the results of the coating repair test, the repair criteria for coatings were defined, and the repair strategy for epoxy anticorrosive coatings on steel structure was proposed. The results show that Marathon 500 super abrasion resistant epoxy paint (M500) and Jotamastic 90 GF low surface treatment epoxy abrasion resistant glass flake paint (J90GF) are suitable for partial repair of epoxy anticorrosive coatings on steel structures, and that Jotamastic 90 low surface treatment epoxy abrasion resistant coating (J90) and Marathon 500 super abrasion resistant epoxy paint (M500) are suitable for integral repair of epoxy anticorrosive coatings on steel structures.
- Open Access
Uniaxial Compressive Stress–Strain Relation of Recycled Coarse Aggregate Concrete with Different Carbonation Depths
The stress–strain relation of recycled aggregate concrete (RAC) after carbonation is very important to the assessment of the durability of RAC. The objective of this study is to investigate the uniaxial compressive stress–strain curves of RAC after carbonation. In this study, the specimens were prepared with 70-mm diameter and 140-mm height cylinders, and the carbonation of the specimens was accelerated after curing 28 days. Then a uniaxial compressive loading test on the specimens was performed by using a mechanical testing machine. The results show that the peak stress () and elastic modulus () of all specimens increase with the increase of carbonation depth. The ratio of ultimate strain to peak strain () and relative toughness of the specimens decrease with the increase of carbonation depth. Furthermore, carbonation has a stronger effect on natural coarse aggregate concrete (NAC) than the 50% replacement rate of RAC with similar compressive strength. Stress–strain models of recycled aggregate concrete with different carbonation depths were established according to experimental results.Open AccessUniaxial Compressive Stress–Strain Relation of Recycled Coarse Aggregate Concrete with Different Carbonation Depths
The stress–strain relation of recycled aggregate concrete (RAC) after carbonation is very important to the assessment of the durability of RAC. The objective of this study is to investigate the uniaxial compressive stress–strain curves of RAC after carbonation. In this study, the specimens were prepared with 70-mm diameter and 140-mm height cylinders, and the carbonation of the specimens was accelerated after curing 28 days. Then a uniaxial compressive loading test on the specimens was performed by using a mechanical testing machine. The results show that the peak stress () and elastic modulus () of all specimens increase with the increase of carbonation depth. The ratio of ultimate strain to peak strain () and relative toughness of the specimens decrease with the increase of carbonation depth. Furthermore, carbonation has a stronger effect on natural coarse aggregate concrete (NAC) than the 50% replacement rate of RAC with similar compressive strength. Stress–strain models of recycled aggregate concrete with different carbonation depths were established according to experimental results. - 24 March 2020
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 1397-1408
Airfield Smart Operations Management and Application of Shared Services
- 24 March 2020
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 1397-1408
Airfield Smart Operations Management and Application of Shared Services