Dongqing Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Dongqing Zhao has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Liyan Xu
Henan University People's Hospital, Henan Provincial People's Hospital, Henan Eye Hospital, Henan Eye Institute, Zhengzhou 450003, China
5 shared publicationsQi Fan
Henan Provincial People's Hospital, Henan Eye Hospital, Henan Eye Institute, People's Hospital of Zhengzhou University, Henan University People's Hospital, Zhengzhou 450003, China
5 shared publicationsKaili Yang
Henan Provincial People's Hospital, Henan Eye Hospital, Henan Eye Institute, People's Hospital of Zhengzhou University, Henan University People's Hospital, Zhengzhou 450003, China
4 shared publications- Shengwei Ren
Henan Provincial People’s Hospital, Henan Eye Hospital, Henan Eye Institute, People’s Hospital of Zhengzhou University, Henan University People’s Hospital, Zhengzhou, China
4 shared publications Kai Guo
Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Henan Eye Hospital & Henan Eye Institution, Zhengzhou, 450003, China
3 shared publicationsMeng Zhu
Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Henan Eye Hospital & Henan Eye Institution, Zhengzhou, 450003, China
3 shared publications
Latest Publications
- Open Access
- 8 July 2022
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 11 (7) , 13
Heritability of Corneal Parameters in Nuclear Families With Keratoconus
Purpose: This study aimed to investigate the heritability of corneal parameters obtained by Pentacam in nuclear families with keratoconus (KC). Methods: A total of 82 patients with KC and their biological parents (n = 164) were recruited in the current study. All subjects underwent corneal tomography with Pentacam. Family units were analyzed to calculate the heritability of corneal parameters by linear mixed effects model using the R statistical software. Results: The pachymetry at apex, pupil, and thinnest point were all significantly heritable at 43.26%, 42.63%, and 43.09%, respectively. The heritability of flat meridian keratometry, steep meridian keratometry, and mean keratometry in the anterior surface were 10.36%, 9.05%, and 10.21%, respectively, and that of flat meridian keratometry, steep meridian keratometry, and mean keratometry in the posterior surface were 8.44%, 9.67%, and 9.06%, respectively. The posterior radius of curvature had higher heritability in comparison with anterior radius of curvature (19.16% vs. 14.37%). Moreover, among combined topometric indices, the heritability of index of vertical asymmetry was the highest (19.49%), and that of central keratoconus index was the lowest (6.64%). Conclusions: The present study demonstrated a substantial heritability of corneal parameters in nuclear families with KC. The pachymetric indices are heritable and may be suitable as KC endophenotypes, suggesting a necessity to discover the genes associated with corneal thickness in KC. Translational Relevance: The pachymetric indices are heritable and may be suitable as KC endophenotypes, indicating that the pachymetric indices might be a corneal characteristic to predict the occurrence of KC.
- 8 July 2022
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 11 (7) , 13
Open AccessHeritability of Corneal Parameters in Nuclear Families With Keratoconus
Purpose: This study aimed to investigate the heritability of corneal parameters obtained by Pentacam in nuclear families with keratoconus (KC). Methods: A total of 82 patients with KC and their biological parents (n = 164) were recruited in the current study. All subjects underwent corneal tomography with Pentacam. Family units were analyzed to calculate the heritability of corneal parameters by linear mixed effects model using the R statistical software. Results: The pachymetry at apex, pupil, and thinnest point were all significantly heritable at 43.26%, 42.63%, and 43.09%, respectively. The heritability of flat meridian keratometry, steep meridian keratometry, and mean keratometry in the anterior surface were 10.36%, 9.05%, and 10.21%, respectively, and that of flat meridian keratometry, steep meridian keratometry, and mean keratometry in the posterior surface were 8.44%, 9.67%, and 9.06%, respectively. The posterior radius of curvature had higher heritability in comparison with anterior radius of curvature (19.16% vs. 14.37%). Moreover, among combined topometric indices, the heritability of index of vertical asymmetry was the highest (19.49%), and that of central keratoconus index was the lowest (6.64%). Conclusions: The present study demonstrated a substantial heritability of corneal parameters in nuclear families with KC. The pachymetric indices are heritable and may be suitable as KC endophenotypes, suggesting a necessity to discover the genes associated with corneal thickness in KC. Translational Relevance: The pachymetric indices are heritable and may be suitable as KC endophenotypes, indicating that the pachymetric indices might be a corneal characteristic to predict the occurrence of KC.
- Open Access
- 26 May 2022
- Published by Wiley in Journal of Ophthalmology
- Vol. 2022, 1-5
A Hospital-Based Study on the Prevalence of Keratoconus in First-Degree Relatives of Patients with Keratoconus in Central China
Purpose. The present study investigated the prevalence of keratoconus (KC) among first-degree relatives of KC patients in Central China. Methods. From July 2018 to March 2022, 661 first-degree relatives of 384 KC patients were included in the present study. Corneal tomography, uncorrected distance visual acuity, manifest refraction with corrected distance visual acuity, intraocular pressure, slit-lamp microscopy, and fundus examination were performed. The diagnosis of KC was based on the Belin/Ambrosio enhanced ectasia total deviation value (BAD-D value) on the Pentacam® system (Oculus GmbH). BAD-D value Results. The present study included 337 (50.98) female and 324 (49.02) male subjects. The prevalence of KC and suspected KC in first-degree relatives was 8.77 (n=58) and 29.05 (n=192), respectively. The prevalence of KC was 9.70 among parents and 7.23 among siblings. Conclusions. The higher prevalence of KC among first-degree relatives of patients with KC suggests that first-degree relatives of KC are at high risk of developing KC.
- 26 May 2022
- Published by Wiley in Journal of Ophthalmology
- Vol. 2022, 1-5
Open AccessA Hospital-Based Study on the Prevalence of Keratoconus in First-Degree Relatives of Patients with Keratoconus in Central China
Purpose. The present study investigated the prevalence of keratoconus (KC) among first-degree relatives of KC patients in Central China. Methods. From July 2018 to March 2022, 661 first-degree relatives of 384 KC patients were included in the present study. Corneal tomography, uncorrected distance visual acuity, manifest refraction with corrected distance visual acuity, intraocular pressure, slit-lamp microscopy, and fundus examination were performed. The diagnosis of KC was based on the Belin/Ambrosio enhanced ectasia total deviation value (BAD-D value) on the Pentacam® system (Oculus GmbH). BAD-D value Results. The present study included 337 (50.98) female and 324 (49.02) male subjects. The prevalence of KC and suspected KC in first-degree relatives was 8.77 (n=58) and 29.05 (n=192), respectively. The prevalence of KC was 9.70 among parents and 7.23 among siblings. Conclusions. The higher prevalence of KC among first-degree relatives of patients with KC suggests that first-degree relatives of KC are at high risk of developing KC.
- 20 February 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 106 (4) , 395-401
Trends in research on corneal cross linking from 2001 to 2020: a bibliometric analysis
The research status and hotspots in the field of corneal cross linking (CXL) can benefit clinicians, researchers and the general public.The purpose of this study was to map the publishing trend on ...
- 20 February 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 106 (4) , 395-401
Trends in research on corneal cross linking from 2001 to 2020: a bibliometric analysis
The research status and hotspots in the field of corneal cross linking (CXL) can benefit clinicians, researchers and the general public.The purpose of this study was to map the publishing trend on ...
- Open Access
- 23 March 2020
- Published by Wiley in Journal of Ophthalmology
- Vol. 2020, 1-9
Assessment of Visual Quality in Eyes with Forme Fruste Keratoconus and Mild and Moderate Keratoconus Based on Optical Quality Analysis System II Parameters
Purpose. The study aimed to evaluate the visual quality of forme fruste keratoconus (FFK) and mild and moderate keratoconus by using an optical quality analysis system II (OQAS-II) and to explore the correlation between optical quality parameters and the disease progression. Methods. Twenty-one normal eyes, twenty-one FFK eyes, twenty-one mild keratoconus eyes, and twenty-one moderate keratoconus eyes were included in this prospective study. The optical quality parameters, such as object scatter index (OSI), modulation transfer function cutoff (MTF cutoff), strehl ratio (SR), and OQAS-II values at contrasts of 100% (OV-100), 20% (OV-20), and 9% (OV-9), were measured by OQAS-II. The repeatability of these parameters was analyzed by intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CVw). Correlations between optical quality parameters and mean central keratometry readings (Kmean) were evaluated. The sensitivity and specificity of the parameters were analyzed using the receiver operating characteristic (ROC). Results. All the optical quality parameters among four groups showed good repeatability (all ICC≥0.75). The MTF cutoff, SR, OV-100, OV-20, OV-9 in FFK, mild and moderate keratoconus eyes were significantly lower than those in the normal group (all ). The ROC analyses of the MTF cutoff, SR, OV-100, OV-20, and OV-9 showed significant area under the curve (AUC) in discriminating FFK form normal, mild keratoconus from FFK, and moderate keratoconus from mild keratoconus (all ). The OSI in mild and moderate keratoconus eyes were significantly higher than that in FFK and normal group (all ), while the OSI showed no significant difference between the FFK group and normal group (). The ROC analyses of the OSI showed significant AUC in discriminating mild keratoconus from FFK and moderate keratoconus from mild keratoconus (all ). In addition, the MTF cutoff was closely correlated to Kmean in keratoconus eyes (r = −0.710, ). Conclusion. The repeatability of OQAS-II is good in measuring visual quality of normal as well as FFK, mild, and moderate keratoconus. The visual quality of the FFK, mild, and moderate keratoconus is worse than that in normal eyes. The OQAS-II has the potential value in screening FFK from normal eyes and might be a useful tool for evaluating the progression of keratoconus.- 23 March 2020
- Published by Wiley in Journal of Ophthalmology
- Vol. 2020, 1-9
Open AccessAssessment of Visual Quality in Eyes with Forme Fruste Keratoconus and Mild and Moderate Keratoconus Based on Optical Quality Analysis System II Parameters
Purpose. The study aimed to evaluate the visual quality of forme fruste keratoconus (FFK) and mild and moderate keratoconus by using an optical quality analysis system II (OQAS-II) and to explore the correlation between optical quality parameters and the disease progression. Methods. Twenty-one normal eyes, twenty-one FFK eyes, twenty-one mild keratoconus eyes, and twenty-one moderate keratoconus eyes were included in this prospective study. The optical quality parameters, such as object scatter index (OSI), modulation transfer function cutoff (MTF cutoff), strehl ratio (SR), and OQAS-II values at contrasts of 100% (OV-100), 20% (OV-20), and 9% (OV-9), were measured by OQAS-II. The repeatability of these parameters was analyzed by intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CVw). Correlations between optical quality parameters and mean central keratometry readings (Kmean) were evaluated. The sensitivity and specificity of the parameters were analyzed using the receiver operating characteristic (ROC). Results. All the optical quality parameters among four groups showed good repeatability (all ICC≥0.75). The MTF cutoff, SR, OV-100, OV-20, OV-9 in FFK, mild and moderate keratoconus eyes were significantly lower than those in the normal group (all ). The ROC analyses of the MTF cutoff, SR, OV-100, OV-20, and OV-9 showed significant area under the curve (AUC) in discriminating FFK form normal, mild keratoconus from FFK, and moderate keratoconus from mild keratoconus (all ). The OSI in mild and moderate keratoconus eyes were significantly higher than that in FFK and normal group (all ), while the OSI showed no significant difference between the FFK group and normal group (). The ROC analyses of the OSI showed significant AUC in discriminating mild keratoconus from FFK and moderate keratoconus from mild keratoconus (all ). In addition, the MTF cutoff was closely correlated to Kmean in keratoconus eyes (r = −0.710, ). Conclusion. The repeatability of OQAS-II is good in measuring visual quality of normal as well as FFK, mild, and moderate keratoconus. The visual quality of the FFK, mild, and moderate keratoconus is worse than that in normal eyes. The OQAS-II has the potential value in screening FFK from normal eyes and might be a useful tool for evaluating the progression of keratoconus. - Open Access
- 25 October 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Repeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
To evaluate the repeatability of corneal biomechanical parameters in normal and keratoconus eyes, and explore factors that affects the repeatability, and further assess the diagnostic ability of new parameters. Seventy-seven keratoconus eyes of 47 patients and 77 right eyes of 77 normal subjects were recruited in current study. All participants received three repeated measurements with 2 to 5 minutes interval. The interclass correlation coefficient (ICC), Cronbach’ α and repeatability coefficient (RC) were evaluated. The liner regression analysis was used to identify factors that affect the repeatability, and linear mixed effects model was performed to compare the parameters differences. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic ability of new parameters. Eighteen parameters in normal eyes and twenty-two parameters in keratoconus eyes showed excellent repeatability (ICC ≥ 0.90). Age, axial measurement (AL), spherical equivalent, astigmatism, gender, mean keratometry (Kmean), intraocular pressure (IOP) and central corneal thickness (CCT) could affect the repeatability of new Corvis ST parameters. Compared with normal eyes, the Ambrósio’s Relational Thickness horizontal (ARTh), biomechanical corrected IOP (bIOP), stiffness parameter at first applanation (SP A1) were low and the Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and Corvis Biomechanical Index (CBI) were high in keratoconus eyes (All P < 0.05). Both ARTh and CBI had high Youden index (0.870), and the corresponding cut-off values were 379.29 and 0.44. The repeatability of Corvis ST parameters was acceptable both in normal and keratoconus eyes, and new parameters could effectively diagnose keratoconus eyes from normal eyes.
- 25 October 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Open AccessRepeatability and comparison of new Corvis ST parameters in normal and keratoconus eyes
To evaluate the repeatability of corneal biomechanical parameters in normal and keratoconus eyes, and explore factors that affects the repeatability, and further assess the diagnostic ability of new parameters. Seventy-seven keratoconus eyes of 47 patients and 77 right eyes of 77 normal subjects were recruited in current study. All participants received three repeated measurements with 2 to 5 minutes interval. The interclass correlation coefficient (ICC), Cronbach’ α and repeatability coefficient (RC) were evaluated. The liner regression analysis was used to identify factors that affect the repeatability, and linear mixed effects model was performed to compare the parameters differences. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic ability of new parameters. Eighteen parameters in normal eyes and twenty-two parameters in keratoconus eyes showed excellent repeatability (ICC ≥ 0.90). Age, axial measurement (AL), spherical equivalent, astigmatism, gender, mean keratometry (Kmean), intraocular pressure (IOP) and central corneal thickness (CCT) could affect the repeatability of new Corvis ST parameters. Compared with normal eyes, the Ambrósio’s Relational Thickness horizontal (ARTh), biomechanical corrected IOP (bIOP), stiffness parameter at first applanation (SP A1) were low and the Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and Corvis Biomechanical Index (CBI) were high in keratoconus eyes (All P < 0.05). Both ARTh and CBI had high Youden index (0.870), and the corresponding cut-off values were 379.29 and 0.44. The repeatability of Corvis ST parameters was acceptable both in normal and keratoconus eyes, and new parameters could effectively diagnose keratoconus eyes from normal eyes.