Zhe Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhe Ding has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Abebe Tilahun Tadie
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China
1 shared publication - Guizhong Wang
Industrial and Technological Research Institute of HIT (Zhangjiakou), Zhangjiakou, China 075421
1 shared publication - Hongbo Li
School of Electronic and Information Engineering, Harbin Institute of Technology, Harbin, China
1 shared publication - Ouyang Zhibin
State Grid Taizhou Power Supply Company, State Grid Jiangsu Electric Power Supply Company Ltd., Taizhou, China
1 shared publication - Yi Yang
State Key Laboratory of Air Traffic Management System and Technology
1 shared publication - Yue Chen
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001, China
1 shared publication
Latest Publications
- Open Access
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 52257-52267
Selection of a Critical Time Scale of Real-Time Dispatching for Power Systems With High Proportion Renewable Power Sources
The power prediction error of uncertain renewable energy sources (URESs) affects the power balance of a power grid. In the power systems with high proportion renewable power sources (PSHPRPSs), automatic generation control (AGC) cannot accommodate the day-ahead power prediction error. The dispatching control system (DCS) of PSHPRPSs adds real-time dispatching links to modify the day-ahead dispatching plan so that the grid power error is within the range of AGC accommodation. This paper proposes a critical time scale (CTS) selection algorithm based on time aggregation characteristics for real-time dispatching of PSHPRPSs and calculates the annual CTS of real-time dispatching of power grids. The uncertainty function is used to describe the relationship between the prediction error of the URESs and the prediction lead time. The total uncertainty function is calculated based on the time aggregation characteristics and is used to select the annual CTS of real-time dispatching. The proposed algorithm quantitatively describes the relationship between the CTS and the operation proportion of URESs and also AGC accommodation capacity. The calculated annual CTS not only ensures the power balance of the power grid, but also avoids the daily change of the CTS. Using the data of URESs in the Irish power grid, the feasibility of the proposed method was verified. The research results of this paper are helpful to accommodate the day-ahead power prediction error of URESs and maintain the safe operation of power grid.
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 52257-52267
Open AccessSelection of a Critical Time Scale of Real-Time Dispatching for Power Systems With High Proportion Renewable Power Sources
The power prediction error of uncertain renewable energy sources (URESs) affects the power balance of a power grid. In the power systems with high proportion renewable power sources (PSHPRPSs), automatic generation control (AGC) cannot accommodate the day-ahead power prediction error. The dispatching control system (DCS) of PSHPRPSs adds real-time dispatching links to modify the day-ahead dispatching plan so that the grid power error is within the range of AGC accommodation. This paper proposes a critical time scale (CTS) selection algorithm based on time aggregation characteristics for real-time dispatching of PSHPRPSs and calculates the annual CTS of real-time dispatching of power grids. The uncertainty function is used to describe the relationship between the prediction error of the URESs and the prediction lead time. The total uncertainty function is calculated based on the time aggregation characteristics and is used to select the annual CTS of real-time dispatching. The proposed algorithm quantitatively describes the relationship between the CTS and the operation proportion of URESs and also AGC accommodation capacity. The calculated annual CTS not only ensures the power balance of the power grid, but also avoids the daily change of the CTS. Using the data of URESs in the Irish power grid, the feasibility of the proposed method was verified. The research results of this paper are helpful to accommodate the day-ahead power prediction error of URESs and maintain the safe operation of power grid.