Nuwandi M. Ariyasingha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Nuwandi M. Ariyasingha has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Eduard Y. Chekmenev
Wayne State University
10 shared publications - Baptiste Joalland
Department of Chemistry, Integrative Biosciences (Ibio), Karmanos Cancer Institute (KCI), Wayne State University, Detroit, Michigan 48202, United States
9 shared publications - Igor V. Koptyug
International Tomography Center SB RAS Novosibirsk Russia
7 shared publications - Kirill Viktorovich Kovtunov
International Tomography Center SB RAS, 3A Institutskaya St., 630090 Novosibirsk, Russia
6 shared publications - Oleg G. Salnikov
International Tomography Center SB RAS Novosibirsk Russia
6 shared publications - Thomas Theis
Department of Chemistry, North Carolina State University, Raleigh, North Carolina, 27965-8204, USA
5 shared publications
Latest Publications
- 12 March 2024
- Published by Wiley in Chemistry – A European Journal
- Vol. 30 (25) , e202304071
Toward Lung Ventilation Imaging Using Hyperpolarized Diethyl Ether Gas Contrast Agent
Hyperpolarized 129Xe gas was FDA‐approved as an inhalable contrast agent for magnetic resonance imaging of a wide range of pulmonary diseases in December 2022. Despite the remarkable success in clinical research settings, the widespread clinical translation of HP 129Xe gas faces two critical challenges: the high cost of the relatively low‐throughput hyperpolarization equipment and the lack of 129Xe imaging capability on clinical MRI scanners, which have narrow‐bandwidth electronics designed only for proton (1H) imaging. To solve this translational grand challenge of gaseous hyperpolarized MRI contrast agents, here we demonstrate the utility of batch‐mode production of proton‐hyperpolarized diethyl ether gas via heterogeneous pairwise addition of parahydrogen to ethyl vinyl ether. An approximately 0.1‐liter bolus of hyperpolarized diethyl ether gas was produced in 1 second and injected in excised rabbit lungs. Lung ventilation imaging was performed using sub‐second 2D MRI with up to 2×2 mm2 in‐plane resolution using a clinical 0.35 T MRI scanner without any modifications. This feasibility demonstration paves the way for the use of inhalable diethyl ether as a gaseous contrast agent for pulmonary MRI applications using any clinical MRI scanner.
- 12 March 2024
- Published by Wiley in Chemistry – A European Journal
- Vol. 30 (25) , e202304071
Toward Lung Ventilation Imaging Using Hyperpolarized Diethyl Ether Gas Contrast Agent
Hyperpolarized 129Xe gas was FDA‐approved as an inhalable contrast agent for magnetic resonance imaging of a wide range of pulmonary diseases in December 2022. Despite the remarkable success in clinical research settings, the widespread clinical translation of HP 129Xe gas faces two critical challenges: the high cost of the relatively low‐throughput hyperpolarization equipment and the lack of 129Xe imaging capability on clinical MRI scanners, which have narrow‐bandwidth electronics designed only for proton (1H) imaging. To solve this translational grand challenge of gaseous hyperpolarized MRI contrast agents, here we demonstrate the utility of batch‐mode production of proton‐hyperpolarized diethyl ether gas via heterogeneous pairwise addition of parahydrogen to ethyl vinyl ether. An approximately 0.1‐liter bolus of hyperpolarized diethyl ether gas was produced in 1 second and injected in excised rabbit lungs. Lung ventilation imaging was performed using sub‐second 2D MRI with up to 2×2 mm2 in‐plane resolution using a clinical 0.35 T MRI scanner without any modifications. This feasibility demonstration paves the way for the use of inhalable diethyl ether as a gaseous contrast agent for pulmonary MRI applications using any clinical MRI scanner.
- 1 January 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 322, 106815
SABRE and PHIP pumped RASER and the route to chaos
- 1 January 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 322, 106815
SABRE and PHIP pumped RASER and the route to chaos
- 28 October 2020
- Published by Wiley in Chemistry – A European Journal
- Vol. 27 (8) , 2774-2781
Low‐Flammable Parahydrogen‐Polarized MRI Contrast Agents
Many MRI contrast agents formed with the parahydrogen‐induced polarization (PHIP) technique exhibit biocompatible profiles. In the context of respiratory imaging with inhalable molecular contrast agents, the development of nonflammable contrast agents would nonetheless be highly beneficial for the biomedical translation of this sensitive, high‐throughput and affordable hyperpolarization technique. To this end, we assess the hydrogenation kinetics, the polarization levels and the lifetimes of PHIP hyperpolarized products (acids, ethers and esters) at various degrees of fluorine substitution. The results highlight important trends as a function of molecular structure that are instrumental for the design of new, safe contrast agents for in vivo imaging applications of the PHIP technique, with an emphasis on the highly volatile group of ethers used as inhalable anesthetics.
- 28 October 2020
- Published by Wiley in Chemistry – A European Journal
- Vol. 27 (8) , 2774-2781
Low‐Flammable Parahydrogen‐Polarized MRI Contrast Agents
Many MRI contrast agents formed with the parahydrogen‐induced polarization (PHIP) technique exhibit biocompatible profiles. In the context of respiratory imaging with inhalable molecular contrast agents, the development of nonflammable contrast agents would nonetheless be highly beneficial for the biomedical translation of this sensitive, high‐throughput and affordable hyperpolarization technique. To this end, we assess the hydrogenation kinetics, the polarization levels and the lifetimes of PHIP hyperpolarized products (acids, ethers and esters) at various degrees of fluorine substitution. The results highlight important trends as a function of molecular structure that are instrumental for the design of new, safe contrast agents for in vivo imaging applications of the PHIP technique, with an emphasis on the highly volatile group of ethers used as inhalable anesthetics.
- Open Access
- 27 October 2020
- Published by Wiley in Chemistry – A European Journal
- Vol. 26 (60)
Frontispiece: Parahydrogen‐Induced Polarization of Diethyl Ether Anesthetic
- 27 October 2020
- Published by Wiley in Chemistry – A European Journal
- Vol. 26 (60)
Open AccessFrontispiece: Parahydrogen‐Induced Polarization of Diethyl Ether Anesthetic
- 15 July 2020
- Published by Wiley in Chemistry – A European Journal
- Vol. 26 (60) , 13621-13626
Parahydrogen‐Induced Polarization of Diethyl Ether Anesthetic
The growing interest in magnetic resonance imaging (MRI) for assessing regional lung function relies on the use of nuclear spin hyperpolarized gas as a contrast agent. The long gas‐phase lifetimes of hyperpolarized 129Xe make this inhalable contrast agent acceptable for clinical research today despite limitations such as high cost, low throughput of production and challenges of 129Xe imaging on clinical MRI scanners, which are normally equipped with proton detection only. We report on low‐cost and high‐throughput preparation of proton‐hyperpolarized diethyl ether, which can be potentially employed for pulmonary imaging with a nontoxic, simple, and sensitive overall strategy using proton detection commonly available on all clinical MRI scanners. Diethyl ether is hyperpolarized by pairwise parahydrogen addition to vinyl ethyl ether and characterized by 1H NMR spectroscopy. Proton polarization levels exceeding 8 % are achieved at near complete chemical conversion within seconds, causing the activation of radio amplification by stimulated emission radiation (RASER) throughout detection. Although gas‐phase T1 relaxation of hyperpolarized diethyl ether (at partial pressure of 0.5 bar) is very efficient, with T1 of ca. 1.2 second, we demonstrate that, at low magnetic fields, the use of long‐lived singlet states created via pairwise parahydrogen addition extends the relaxation decay by approximately threefold, paving the way to bioimaging applications and beyond.
- 15 July 2020
- Published by Wiley in Chemistry – A European Journal
- Vol. 26 (60) , 13621-13626
Parahydrogen‐Induced Polarization of Diethyl Ether Anesthetic
The growing interest in magnetic resonance imaging (MRI) for assessing regional lung function relies on the use of nuclear spin hyperpolarized gas as a contrast agent. The long gas‐phase lifetimes of hyperpolarized 129Xe make this inhalable contrast agent acceptable for clinical research today despite limitations such as high cost, low throughput of production and challenges of 129Xe imaging on clinical MRI scanners, which are normally equipped with proton detection only. We report on low‐cost and high‐throughput preparation of proton‐hyperpolarized diethyl ether, which can be potentially employed for pulmonary imaging with a nontoxic, simple, and sensitive overall strategy using proton detection commonly available on all clinical MRI scanners. Diethyl ether is hyperpolarized by pairwise parahydrogen addition to vinyl ethyl ether and characterized by 1H NMR spectroscopy. Proton polarization levels exceeding 8 % are achieved at near complete chemical conversion within seconds, causing the activation of radio amplification by stimulated emission radiation (RASER) throughout detection. Although gas‐phase T1 relaxation of hyperpolarized diethyl ether (at partial pressure of 0.5 bar) is very efficient, with T1 of ca. 1.2 second, we demonstrate that, at low magnetic fields, the use of long‐lived singlet states created via pairwise parahydrogen addition extends the relaxation decay by approximately threefold, paving the way to bioimaging applications and beyond.
- 24 March 2020
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 59 (22) , 8654-8660
Parahydrogen‐Induced Radio Amplification by Stimulated Emission of Radiation
Radio amplification by stimulated emission of radiation (RASER) was recently discovered in a low‐field NMR spectrometer incorporating a highly specialized radio‐frequency resonator, where a high degree of proton‐spin polarization was achieved by reversible parahydrogen exchange. RASER activity, which results from the coherent coupling between the nuclear spins and the inductive detector, can overcome the limits of frequency resolution in NMR. Here we show that this phenomenon is not limited to low magnetic fields or the use of resonators with high‐quality factors. We use a commercial bench‐top 1.4 T NMR spectrometer in conjunction with pairwise parahydrogen addition producing proton‐hyperpolarized molecules in the Earth's magnetic field (ALTADENA condition) or in a high magnetic field (PASADENA condition) to induce RASER without any radio‐frequency excitation pulses. The results demonstrate that RASER activity can be observed on virtually any NMR spectrometer and measures most of the important NMR parameters with high precision.
- 24 March 2020
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 59 (22) , 8654-8660
Parahydrogen‐Induced Radio Amplification by Stimulated Emission of Radiation
Radio amplification by stimulated emission of radiation (RASER) was recently discovered in a low‐field NMR spectrometer incorporating a highly specialized radio‐frequency resonator, where a high degree of proton‐spin polarization was achieved by reversible parahydrogen exchange. RASER activity, which results from the coherent coupling between the nuclear spins and the inductive detector, can overcome the limits of frequency resolution in NMR. Here we show that this phenomenon is not limited to low magnetic fields or the use of resonators with high‐quality factors. We use a commercial bench‐top 1.4 T NMR spectrometer in conjunction with pairwise parahydrogen addition producing proton‐hyperpolarized molecules in the Earth's magnetic field (ALTADENA condition) or in a high magnetic field (PASADENA condition) to induce RASER without any radio‐frequency excitation pulses. The results demonstrate that RASER activity can be observed on virtually any NMR spectrometer and measures most of the important NMR parameters with high precision.
- 24 March 2020
- Published by Wiley in Angewandte Chemie
- Vol. 132 (22) , 8732-8738
Parahydrogen‐Induced Radio Amplification by Stimulated Emission of Radiation
Radio amplification by stimulated emission of radiation (RASER) was recently discovered in a low‐field NMR spectrometer incorporating a highly specialized radio‐frequency resonator, where a high degree of proton‐spin polarization was achieved by reversible parahydrogen exchange. RASER activity, which results from the coherent coupling between the nuclear spins and the inductive detector, can overcome the limits of frequency resolution in NMR. Here we show that this phenomenon is not limited to low magnetic fields or the use of resonators with high‐quality factors. We use a commercial bench‐top 1.4 T NMR spectrometer in conjunction with pairwise parahydrogen addition producing proton‐hyperpolarized molecules in the Earth's magnetic field (ALTADENA condition) or in a high magnetic field (PASADENA condition) to induce RASER without any radio‐frequency excitation pulses. The results demonstrate that RASER activity can be observed on virtually any NMR spectrometer and measures most of the important NMR parameters with high precision.
- 24 March 2020
- Published by Wiley in Angewandte Chemie
- Vol. 132 (22) , 8732-8738
Parahydrogen‐Induced Radio Amplification by Stimulated Emission of Radiation
Radio amplification by stimulated emission of radiation (RASER) was recently discovered in a low‐field NMR spectrometer incorporating a highly specialized radio‐frequency resonator, where a high degree of proton‐spin polarization was achieved by reversible parahydrogen exchange. RASER activity, which results from the coherent coupling between the nuclear spins and the inductive detector, can overcome the limits of frequency resolution in NMR. Here we show that this phenomenon is not limited to low magnetic fields or the use of resonators with high‐quality factors. We use a commercial bench‐top 1.4 T NMR spectrometer in conjunction with pairwise parahydrogen addition producing proton‐hyperpolarized molecules in the Earth's magnetic field (ALTADENA condition) or in a high magnetic field (PASADENA condition) to induce RASER without any radio‐frequency excitation pulses. The results demonstrate that RASER activity can be observed on virtually any NMR spectrometer and measures most of the important NMR parameters with high precision.
- 10 July 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 10 (15) , 4229-4236
Quasi-Resonance Fluorine-19 Signal Amplification by Reversible Exchange
We report on an extension of the quasi-resonance (QUASR) pulse sequence used for signal amplification by reversible exchange (SABRE), showing that we may target distantly J-coupled 19F-spins. Polarization transfer from the parahydrogen-derived hydrides to the 19F nucleus is accomplished via weak five-bond J-couplings using a shaped QUASR radio frequency pulse at a 0.05 T magnetic field. The net result is the direct generation of hyperpolarized 19F z-magnetization, derived from the parahydrogen singlet order. An accumulation of 19F polarization on the free ligand is achieved with subsequent repetition of this pulse sequence. The hyperpolarized 19F signal exhibits clear dependence on the pulse length, irradiation frequency, and delay time in a manner similar to that reported for 15N QUASR-SABRE. Moreover, the hyperpolarized 19F signals of 3-19F-14N-pyridine and 3-19F-15N-pyridine isotopologues are similar, suggesting that (i) polarization transfer via QUASR-SABRE is irrespective of the nitrogen isotopologue and (ii) the presence or absence of the spin-1/2 15N nucleus has no impact on the efficiency of QUASR-SABRE polarization transfer. Although optimization of polarization transfer efficiency to 19F (P19F ≈ 0.1%) was not the goal of this study, we show that high-field SABRE can be efficient and broadly applicable for direct hyperpolarization of 19F spins.
- 10 July 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 10 (15) , 4229-4236
Quasi-Resonance Fluorine-19 Signal Amplification by Reversible Exchange
We report on an extension of the quasi-resonance (QUASR) pulse sequence used for signal amplification by reversible exchange (SABRE), showing that we may target distantly J-coupled 19F-spins. Polarization transfer from the parahydrogen-derived hydrides to the 19F nucleus is accomplished via weak five-bond J-couplings using a shaped QUASR radio frequency pulse at a 0.05 T magnetic field. The net result is the direct generation of hyperpolarized 19F z-magnetization, derived from the parahydrogen singlet order. An accumulation of 19F polarization on the free ligand is achieved with subsequent repetition of this pulse sequence. The hyperpolarized 19F signal exhibits clear dependence on the pulse length, irradiation frequency, and delay time in a manner similar to that reported for 15N QUASR-SABRE. Moreover, the hyperpolarized 19F signals of 3-19F-14N-pyridine and 3-19F-15N-pyridine isotopologues are similar, suggesting that (i) polarization transfer via QUASR-SABRE is irrespective of the nitrogen isotopologue and (ii) the presence or absence of the spin-1/2 15N nucleus has no impact on the efficiency of QUASR-SABRE polarization transfer. Although optimization of polarization transfer efficiency to 19F (P19F ≈ 0.1%) was not the goal of this study, we show that high-field SABRE can be efficient and broadly applicable for direct hyperpolarization of 19F spins.
- 11 April 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 123 (18) , 11734-11744
Relaxation Dynamics of Nuclear Long-Lived Spin States in Propane and Propane-d6 Hyperpolarized by Parahydrogen
We report a systematic study of relaxation dynamics of hyperpolarized (HP) propane and HP propane-d6 prepared by heterogeneous pairwise parahydrogen addition to propylene and propylene-d6 respectively. Long-lived spin states (LLSSsLLS) created for these molecules at the low magnetic field of 0.0475 T were employed for this study. The parahydrogen-induced overpopulation of a HP propane LLSS decays exponentially with time constant (TLLSSLLS) approximately 3-fold greater than the corresponding T1 values. Both TLLSSLLS and T1 increase linearly with propane pressure in the range from 1 atm (the most biomedically relevant conditions for pulmonary MRI) to 5 atm. The TLLSSLLS value of HP propane gas at 1 atm is ~3 s. Deuteration of the substrate (propylene-d6) yields hyperpolarized propane-d6 gas with TLLSSLLS values approximately 20% shorter than those of hyperpolarized fully protonated propane gas, indicating that deuteration does not benefit the lifetime of the LLSSLLS HP state. The use of pH2 or Xe/N2 buffering gas during heterogeneous hydrogenation reaction (leading to production of 100% HP propane (no buffering gas) versus 43% HP propane gas (with 57% buffering gas) composition mixtures) results in (i) no significant changes in T1, (ii) decrease of TLLSSLLS values (by 357% and 87% respectively); and (iii) an increase of the polarization levels of HP propane gas with a propane concentration decrease (by 1.60.1-fold and 1.40.1-fold respectively despite the decrease in TLLSSLLS, which leads to disproportionately greater polarization losses during HP gas transport). Moreover, we demonstrate the feasibility of HP propane cryo-collection (which can be potentially useful for preparing larger amounts of concentrated HP propane, when buffering gas is employed), and TLLSSLLS of liquefied HP propane reaches 14.7 seconds, which is greater than the TLLSSLLS value of HP propane gas at any pressure studied. Finally, we have explored the utility of using a partial Spin-Lock Induced Crossing (SLIC) radio frequency (RF) pulse sequence for converting the overpopulated LLSSLLS into observable 1H nuclear magnetization at low magnetic field. We find that (i) the bulk of the overpopulated LLSSLLS is retained even when the optimal or near-optimal values of SLIC pulse duration are employed, and (ii) the overpopulated LLSSLLS of propane is also relatively immune to strong RF pulses—thereby, indicating that LLSSLLS is highly suitable as a spin-polarization reservoir in the context of NMR/MRI detection applications. The presented findings may be useful for improving the levels of polarization of HP propane produced by HET-PHIP via the use of an inert buffer gas; increasing the lifetime of the HP state during preparation and storage; and developing efficient approaches for ultrafast MR imaging of HP propane in the context of biomedical applications of HP propane gas, including its potential use as an inhalable contrast agent.
- 11 April 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 123 (18) , 11734-11744
Relaxation Dynamics of Nuclear Long-Lived Spin States in Propane and Propane-d6 Hyperpolarized by Parahydrogen
We report a systematic study of relaxation dynamics of hyperpolarized (HP) propane and HP propane-d6 prepared by heterogeneous pairwise parahydrogen addition to propylene and propylene-d6 respectively. Long-lived spin states (LLSSsLLS) created for these molecules at the low magnetic field of 0.0475 T were employed for this study. The parahydrogen-induced overpopulation of a HP propane LLSS decays exponentially with time constant (TLLSSLLS) approximately 3-fold greater than the corresponding T1 values. Both TLLSSLLS and T1 increase linearly with propane pressure in the range from 1 atm (the most biomedically relevant conditions for pulmonary MRI) to 5 atm. The TLLSSLLS value of HP propane gas at 1 atm is ~3 s. Deuteration of the substrate (propylene-d6) yields hyperpolarized propane-d6 gas with TLLSSLLS values approximately 20% shorter than those of hyperpolarized fully protonated propane gas, indicating that deuteration does not benefit the lifetime of the LLSSLLS HP state. The use of pH2 or Xe/N2 buffering gas during heterogeneous hydrogenation reaction (leading to production of 100% HP propane (no buffering gas) versus 43% HP propane gas (with 57% buffering gas) composition mixtures) results in (i) no significant changes in T1, (ii) decrease of TLLSSLLS values (by 357% and 87% respectively); and (iii) an increase of the polarization levels of HP propane gas with a propane concentration decrease (by 1.60.1-fold and 1.40.1-fold respectively despite the decrease in TLLSSLLS, which leads to disproportionately greater polarization losses during HP gas transport). Moreover, we demonstrate the feasibility of HP propane cryo-collection (which can be potentially useful for preparing larger amounts of concentrated HP propane, when buffering gas is employed), and TLLSSLLS of liquefied HP propane reaches 14.7 seconds, which is greater than the TLLSSLLS value of HP propane gas at any pressure studied. Finally, we have explored the utility of using a partial Spin-Lock Induced Crossing (SLIC) radio frequency (RF) pulse sequence for converting the overpopulated LLSSLLS into observable 1H nuclear magnetization at low magnetic field. We find that (i) the bulk of the overpopulated LLSSLLS is retained even when the optimal or near-optimal values of SLIC pulse duration are employed, and (ii) the overpopulated LLSSLLS of propane is also relatively immune to strong RF pulses—thereby, indicating that LLSSLLS is highly suitable as a spin-polarization reservoir in the context of NMR/MRI detection applications. The presented findings may be useful for improving the levels of polarization of HP propane produced by HET-PHIP via the use of an inert buffer gas; increasing the lifetime of the HP state during preparation and storage; and developing efficient approaches for ultrafast MR imaging of HP propane in the context of biomedical applications of HP propane gas, including its potential use as an inhalable contrast agent.
- 11 March 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (7) , 4741-4746
Clinical-Scale Batch-Mode Production of Hyperpolarized Propane Gas for MRI
NMR spectroscopy and imaging (MRI) are two of the most important methods to study structure, function, and dynamics from atom to organism scale. NMR approaches often suffer from an insufficient sensitivity, which, however, can be transiently boosted using hyperpolarization techniques. One of these techniques is parahydrogen-induced polarization, which has been used to produce catalyst-free hyperpolarized propane gas with proton polarization that is 3 orders of magnitude greater than equilibrium thermal polarization at a 1.5 T field of a clinical MRI scanner. Here we show that more than 0.3 L of hyperpolarized propane gas can be produced in 2 s. This production rate is more than an order of magnitude greater than that demonstrated previously, and the reported production rate is comparable to that employed for in-human MRI using HP noble gas (e.g., 129Xe) produced via a spin exchange optical pumping (SEOP) hyperpolarization technique. We show that high polarization values can be retained despite the significant increase in the production rate of hyperpolarized propane. The enhanced signals of produced hyperpolarized propane gas were revealed by stopped-flow MRI visualization at 4.7 T. Achieving this high production rate enables the future use of this compound (already approved for unlimited use in foods by the corresponding regulating agencies, e.g., FDA in the USA, and more broadly as an E944 food additive) as a new inhalable contrast agent for diagnostic detection via MRI.
- 11 March 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (7) , 4741-4746
Clinical-Scale Batch-Mode Production of Hyperpolarized Propane Gas for MRI
NMR spectroscopy and imaging (MRI) are two of the most important methods to study structure, function, and dynamics from atom to organism scale. NMR approaches often suffer from an insufficient sensitivity, which, however, can be transiently boosted using hyperpolarization techniques. One of these techniques is parahydrogen-induced polarization, which has been used to produce catalyst-free hyperpolarized propane gas with proton polarization that is 3 orders of magnitude greater than equilibrium thermal polarization at a 1.5 T field of a clinical MRI scanner. Here we show that more than 0.3 L of hyperpolarized propane gas can be produced in 2 s. This production rate is more than an order of magnitude greater than that demonstrated previously, and the reported production rate is comparable to that employed for in-human MRI using HP noble gas (e.g., 129Xe) produced via a spin exchange optical pumping (SEOP) hyperpolarization technique. We show that high polarization values can be retained despite the significant increase in the production rate of hyperpolarized propane. The enhanced signals of produced hyperpolarized propane gas were revealed by stopped-flow MRI visualization at 4.7 T. Achieving this high production rate enables the future use of this compound (already approved for unlimited use in foods by the corresponding regulating agencies, e.g., FDA in the USA, and more broadly as an E944 food additive) as a new inhalable contrast agent for diagnostic detection via MRI.